Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Similar documents
Installation Instructions for Aux 101 Kit A044Z055

Installation Instructions for Load Management Kit A051C329

Installation Manual. TRACKERmarine Genset Series 4000 KY. Printed in U. S. A. 8-95

JuiceBox Operator s Manual

Installation Manual. English. French

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

Prodigy HDLV Generation II Pump Panel

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Voltmaster Centrifugal Trash Pumps

Caution: This document contains mixed page sizes (8.5 x 11 or 11 x 17), which may affect printing. Please adjust your printer settings according to

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Installation Manual. RV Generator Set. HDZAA (Spec A D) English Original Instructions (Issue 8)

High Frequency SineWave Guardian TM

75918 Heavy Duty 3-Point Mount

Table of Contents. Safety symbols... 3 Assembly 6. Operation Maintenance Troubleshooting 11. Storage. 12. Notes. 13

Generator Set Ford V L Engine with PowerCommand 2100 Control

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

Operator Manual. Generator Set with PowerCommand Control GGMA (Spec A C) GGMB (Spec A C) GGMC (Spec A C)

Safety Training Topic ELECTRICAL SAFETY

Operator Manual. Generator Set with PowerCommand 3201 Controller. DQKAA (Spec A D) DQKAB (Spec A D)

Solar Charge Controller Owner s Manual SC 1210 SC 1210LD SC 1220LD

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

Detector Control Generator Sets

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Installation Instructions for the PowerCommand 3100 FT-10 Network Genset Communications Module (GCM) Kit

MASTERsine Inverter PXA Series Installation Guide

Generator Set with QSJ5.9G Engine and PowerCommand 1.1/2.3 Control

The information in this guide will allow response to emergencies involving Balance Hybrid E450 vehicles.

Utility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.

BusPro Series Instruction Manual

Generator Set Ford V L Engine with PowerCommand 2100 Control

Standby Power Generator Set with PC1.1 Control

Propane torch. Model Assembly And Operation Instructions

PROPANE TORCH WITH TURBO BURNER

MANUAL FLUID EXTRACTOR

Log Splitter. Owner/Operator Manual. Models HCWP1-26

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

STEP-BY-STEP INSTALLATION GUIDE

TT /17 INSTALLATION INSTRUCTIONS. Introduction. Required Tools and Equipment

Safety Working with LV Drives

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Caution: This document contains mixed page sizes (8.5 x 11 or 11 x 17), which may affect printing. Please adjust your printer settings according to

IMPORTANT INFORMATION

IMPORTANT INFORMATION

Policy Sponsor: Assistant Vice President. Responsible Unit: Facilities Management

North Dakota State University Grounds Maintenance Equipment

TABLE OF CONTENTS. INTRODUCTION to the PSI COOL... 2 SAFETY INFORMATION... 3 SYSTEM FEATURES & SPECIFICATIONS... 9 MACHINE OVERVIEW...

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Transfer Switch. RA Series 100A (Spec B) 200A (Spec B) 400A (Spec A) English Original Instructions A056K730 (Issue 3)

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

User s Manual. Automatic Switch-Mode Battery Charger

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

Important Safety Instructions

Battery Capacity Analyzer

EV-2051-M Electric Motor. Operation and Maintenance Manual

Model: SPTOGT01 TRACTOR PTO GENERATOR

Sentry Battery Charger. Installation and Operations Manual Section 75

Cruising Charger Series OWNER S MANUAL

South Magellan Drive, Torrance, California USA

TABLE OF CONTENTS. INTRODUCTION to the BrakeMate Jr... 2 SAFETY INFORMATION... 3 SYSTEM FEATURES & SPECIFICATIONS... 9 MACHINE OVERVIEW...

PI1500X Power Inverter User s Manual

QSB5 G5 and QSB5 G6 Engines with PowerCommand 2.3 Control

AVOIDING ELECTROCUTION HAZARDS

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

2009 ESCAPE HYBRID MARINER HYBRID

Freedom egen System End-of- Line Functional Checklist

Walk-Behind Sprayer SL-80 & SL-80SS. Owner's Manual and Installation Instructions Original Instructions CAUTION

SeekTech Inductive Clamp

Installation instruction

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

TRIBUTE HYBRID EMERGENCY RESPONSE GUIDE ERG-08HEV

Models 8100PP & 86110LP. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Low Profile Tailgate Spreaders SWING AWAY Mount

Operators Manual Models HDCAC, HDCAD

4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL

X100P Load Bank. Read all instructions before using the load bank. Contents

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Power Inverter. Owner s Manual

MOTORVAC TECHNOLOGIES INC. TRANSTECH-1000 Transmission Service System

Instruction Manual CORDLESS DRILL & DRIVER 18V. Model SROM 1170

Air-Operated Waste Oil Drainer

I. Safety precautions

1/2 HP SUMP PUMP OWNER'S MANUAL

PAGE 1 OF 6 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S450 Motor Vehicle Safety REV /01/09

RMT1201. ORIGINAL INSTRUCTIONS Cordless Multi-Tool

PA 5000 INSTRUCTION MANUAL

Special Post Crash Safety Considerations

MOUNT KIT PERSONAL PLOW

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Service Bulletin Trucks

Operations and Service Manual. XE400D-SB Load Bank

30 Amp Solar Charge Controller

Transcription:

Instruction Sheet 7-2013 Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 1 Introduction The information contained within is based on information available at the time of going to print. In line with Cummins Power Generation policy of continuous development and improvement, information may change at any time without notice. The users should therefore make sure that before commencing any work, they have the latest information available. The latest version of this manual is available on QuickServe Online (https://qsol.cummins.com/info/index.html). 2 Safety Precautions 2.1 General Safety Precautions Coolants under pressure can cause severe scalding. Do not open a radiator or heat exchanger pressure cap while the engine is running. Let the engine cool down before removing the coolant pressure cap. Turn the cap slowly and do not open it fully until the pressure has been relieved. Moving parts can cause severe personal injury or death and hot exhaust parts can cause severe burns. Make sure all protective guards are properly in place before starting the generator set. Used engine oils have been identified by some state and federal agencies to cause cancer or reproductive toxicity. Do not ingest, breathe the fumes, or contact used oil when checking or changing engine oil. Operation of equipment is unsafe when mentally or physically fatigued. Do not operate equipment in this condition, or after consuming any alcohol or drug. Substances in exhaust gases have been identified by some state and federal agencies to cause cancer or reproductive toxicity. Do not breath in or come into contact with exhaust gases. English - Original Instructions Page 1 of 12 2013 Cummins Power Generation, Inc. All rights reserved.

Flammable liquids can cause fire or explosion. Do not store fuel, cleaners, oil, etc. near the generator set. Wear hearing protection when going near an operating generator set. Hot metal parts can cause severe burns. Avoid contact with the radiator, turbo charger, and exhaust system. Maintaining or installing a generator set can cause severe personal injury. Wear personal protective equipment such as safety glasses, protective gloves, hard hats, steel-toed boots, and protective clothing when working on equipment. Ethylene glycol, used as engine coolant, is toxic to humans and animals. Clean up coolant spills and dispose of used antifreeze in accordance with local environmental regulations. Starting fluids, such as ether, can cause explosion and generator set engine damage. Do not use. Stepping on the generator set can cause parts to bend or break, leading to electrical shorts, or to fuel, coolant, or exhaust leaks. Do not step on the generator set when entering or leaving the generator room. To prevent accidental or remote starting while working on the generator set, disconnect the negative ( ) battery cable at the battery using an insulated wrench. Make sure that rags are not left on or near the engine. Make sure the generator set is mounted in a manner to prevent combustible materials from accumulating under the unit. Accumulated grease and oil can cause overheating and engine damage presenting a potential fire hazard. Keep the generator set clean and repair any oil leaks promptly. Page 2 of 12

Before performing maintenance and service procedures on enclosed generator sets, make sure the service access doors are secured open. Keep the generator set and the surrounding area clean and free from obstructions. Remove any debris from the set and keep the floor clean and dry. NOTICE Keep multi-class ABC fire extinguishers handy. Class A fires involve ordinary combustible materials such as wood and cloth. Class B fires involve combustible and flammable liquid fuels and gaseous fuels. Class C fires involve live electrical equipment. (Refer to NFPA No. 10 in applicable region.) 2.2 Generator Set Safety Code Before operating the generator set, read the manuals and become familiar with them and the equipment. Safe and efficient operation can be achieved only if the equipment is properly operated and maintained. Many accidents are caused by failure to follow fundamental rules and precautions. Improper operation and maintenance can lead to severe personal injury, or loss of life and property, by fire, electrocution, mechanical breakdown, or exhaust gas asphyxiation. Read and follow all Safety Precautions, Warnings, and Cautions throughout this manual and the documentation supplied with your generator set. Lifting and repositioning of the generator set must only be carried out using suitable lifting equipment, shackles, and spreader bars, in accordance with local guidelines and legislation, by suitably trained and experienced personnel. Incorrect lifting can result in severe personal injury, death, and/or equipment damage. For more information, contact your authorized distributor. 2.3 Electrical Shocks and Arc Flashes Can Cause Severe Personal Injury or Death Any work with exposed energized circuits with potentials of 50 Volts AC or 75 Volts DC or higher poses a significant risk of electrical shock and electrical arc flash. These silent hazards can cause severe injuries or death. Refer to standard NFPA 70E or equivalent safety standards in corresponding regions for details of the dangers involved and for the safety requirements. Guidelines to follow when working on de-energized electrical systems: Use proper PPE. Do not wear jewelry and make sure that any conductive items are removed from pockets as these items can fall into equipment and the resulting short circuit can cause shock or burning. Refer to standard NFPA 70E for PPE standards. Page 3 of 12

De-energize and lockout/tagout electrical systems prior to working on them. Lockout/Tagout is intended to prevent injury due to unexpected start-up of equipment or the release of stored energy. Please refer to the lockout/tagout section for more information. De-energize and lockout/tagout all circuits and devices before removing any protective shields or making any measurements on electrical equipment. Follow all applicable regional electrical and safety codes. Guidelines to follow when working on energized electrical systems: NOTICE It is the policy of Cummins Inc. to perform all electrical work in a de-energized state. However, employees or suppliers may be permitted to occasionally perform work on energized electrical equipment only when qualified and authorized to do so and when troubleshooting, or if deenergizing the equipment would create a greater risk or make the task impossible and all other alternatives have been exhausted. NOTICE Exposed energized electrical work is only allowed as per the relevant procedures and must be undertaken by a Cummins authorized person with any appropriate energized work permit for the work to be performed while using proper PPE, tools and equipment. In summary: Do not tamper with or bypass interlocks unless you are authorized to do so. Understand and assess the risks - use proper PPE. Do not wear jewelry and make sure that any conductive items are removed from pockets as these items can fall into equipment and the resulting short circuit can cause shock or burning. Refer to standard NFPA 70E for PPE standards. Make sure that an accompanying person who can undertake a rescue is nearby. 3 Instruction 3.1 Installation of the Remote Mount HMI 211 Display Panel This instruction sheet describes the installation of a remote mounted HMI 211 display panel for use with a PCC 1302 controller. Refer to Figure 1. Page 4 of 12

FIGURE 1. HMI 211 DISPLAY PANEL AC voltages and currents present an electrical shock and arc flash hazard. Only technically qualified and trained personnel are to perform service procedures. Voltages up to 600 VAC can be present inside the electrical enclosures. Incorrect installation, service, or replacement of parts can result in severe personal injury, death, or equipment damage. Improper handling of components (even with power removed) can cause electrostatic discharge that damage circuit components. Make certain the battery area has been well-ventilated before servicing the battery. Wear protective clothing and safety goggles. Stop the genset and disconnect the charger before disconnecting battery cables. Arcing can ignite explosive hydrogen gas given off by batteries, causing severe personal injury. Arcing can occur when a battery cable are removed or reattached, or when the negative [-] battery cable is connected and a tool used to connect or disconnect the positive [+] battery cable touches the frame or other grounded metal part of the generator set. Always remove the negative [-] cable first, and reconnect it last. Make certain hydrogen from the battery, engine fuel, and other explosive fumes are fully dissipated. This is especially important if the battery has been connected to a battery charger Ignition of explosive battery gases can cause severe personal injury or death. Arcing at battery terminals, operation of light switches, operation of other equipment, open flame, pilot lights, and sparks can ignite battery gas. Do not smoke, or switch trouble light ON or OFF near a battery. Discharge static electricity charge from your body before touching batteries by touching a grounded metal surface. NOTICE HMI 211 mounting distance from the 1302 controller is limited to a cable distance of 4000 feet (1219 meters). Page 5 of 12

1. Make sure the generator set is shut down and disabled. a. Place the generator set O/Manual/Auto switch in the O (OFF) position. b. Turn off and disconnect the battery charger (if equipped). c. Disconnect the negative [-] cable from the battery and secure it from contacting the battery terminals to prevent accidental starting. 2. Use the footprint template shown in Figure 2 as the mounting panel cutout. FIGURE 2. DISPLAY PANEL FOOTPRINT 3. Use the footprint template in Figure 2 for drilling four 4 mm (0.16 in) mounting holes. 4. Mount the HMI 211 with four number 6 screws, nuts and washers. 5. Insert the harness plug P1 into HMI 211 J1 connector. Refer to Figure 3 and Figure 4. Page 6 of 12

No. Description No. Description 1 J1 and J2 Wiring Connectors 2 P1 Harness Plug FIGURE 3. CONNECTING THE HMI 211 REMOTE No. Description No. Description 1 TB15 2 TB1 FIGURE 4. PCC 1302 TERMINAL BLOCKS TB1 AND TB15 6. The HMI 211 can be powered from PCC 1302 if within 500 feet (152 meters); see the wiring schematic in Figure 5. If greater than 500 feet, power must come from an isolated 12 or 24 VDC power supply with 3 amp overcurrent protection. Select the appropriate wire size from Table 1. Page 7 of 12

TABLE 1. WIRE SIZE B+ and GND Wiring Maximum Mounting Distance from the Generator Set in Feet (Meters) 14 AWG 500 (152.4) 16 AWG 200 (61) 18 AWG 100 (30.5) 7. Use Class 5, 22 AWG shielded stranded twisted pair wire for making the PCC NET connections between PCC 1302 and HMI 211 harness. Refer to the wiring schematic in Figure 5. FIGURE 5. WIRING SCHEMATIC 8. Use 18 AWG stranded wire to make the Wakeup and Remote Start connections between PCC 1302 and HMI 211 harness. Refer to the wiring schematic in Figure 5. 9. Reconnect the generator set as follows: a. Connect the negative [-] cable to the battery. b. Reconnect the battery charger (if used). 10. Configure the remote HMI 211 for REMOTE operation (see Figure 6 and Figure 7): a. To view the first Service menu, simultaneously press the up and down selection buttons for two seconds. b. Press the (1) button to view the Setup Password menu. c. Enter the password (574) and press the arrow ( ) selection button. The Setup menu is displayed. d. Press the (1) button to view the main Genset Service menu. e. Press the (1) button again to view the first Genset submenu. f. Press the down button repeatedly until the Display Setup menu is displayed. g. Press the ADJUST button. h. Use the + or - symbol buttons to change the Connection to "Remote." Page 8 of 12

i. Press the SAVE button to save your changes. 11. Start the unit and verify functionality from the remote, using the instructions in the PCC 1302, Owner Manual. Page 9 of 12

Page 10 of 12 FIGURE 6. CONFIGURING THE REMOTE DISPLAY PANEL (SHEET 1 OF 2)

FIGURE 7. CONFIGURING THE REMOTE DISPLAY PANEL (SHEET 2 OF 2) 3.2 Instructions for Updating HMI 211 Firmware It may be necessary to update the HMI 211 in the field using the Cummins InPower Service Tool. These instructions give the procedure for the update process. Page 11 of 12

The following hardware and firmware are required: Service Tool harness Latest version of the HMI 211 firmware, which can be retrieved from the InCal website at http://cumminspower.com/en/services/software/ 1. Disconnect generator set harness plug P1 (shown in Figure 3) from the back of the HMI 211. 2. Disconnect TB1-1 or TB1-2 (shown in Figure 4) from the PCC 1302. This will interrupt communication between the PCC 1302 and HMI 211 while allowing the PCC 1302 to continue to supply power to the HMI 211. 3. Reconnect generator set harness plug P1 to the back of the HMI 211. The HMI 211 will display an error screen. 4. Connect Service Tool harness plug P1 to the open connector on the back of the HMI 211 display. 5. Connect harness plug P2 (shown below) to the laptop's USB port via converter. No. Description No. Description 1 Harness Plug P2 3 Harness Plug P1 2 TB-2 4 Harness Plug P3 FIGURE 8. SERVICE TOOL HARNESS 6. Connect to the HMI 211 with the InPower Service Tool. 7. Download the latest version of HMI 211 firmware. 8. When the download has been completed, disconnect the InPower Service Tool. 9. Disconnect harness plug P1 from the back of the HMI 211. 10. Reconnect TB1-1 or TB1-2 to the PCC 1302. This will enable communication between the PCC 1302 and HMI 211. 11. Reconnect harness plug P1 to the back of the HMI 211. The HMI 211 will initialize and supply the proper information. Page 12 of 12