Schindler Passenger Elevators
2
Advanced technology for green performance. Drive A high-performance gearless drive with economical and environmental friendly operation. The central suspension and variable-frequency control deliver a smooth ride, free of vibrations and jerks. The advanced compact motor is optimized to save energy, produce minimal heat and runs quietly. True comfort for the passengers. The drive levels the car precisely to the landing allowing passengers to enter and leave safely. Traction media The innovative traction medium replaces conventional steel ropes. It s lighter, needs less space, and is quieter. Thanks to this innovation, less noise is transmitted to the car and building. The hoistway is efficiently utilized, ride comfort is significantly increased. Control The highly integrated microprocessor control system optimally manages the diverse operations of single-car installations as well as groups of up to eight elevators. For individual configurations more than 100 control options are possible. Many of which provide energysaving standby operations. When the car is empty, the car lighting and ventilation are automatically switched into energy-saving mode. During balanced travel, the frequency converter switches over to low energy consumption. Key switches or allowance for card readers are options. Car & hoistway The car is centrally guided and ideally balanced, which reduces friction and energy losses. The design allows flexible hoistway and car dimensions. This means much greater planning freedom. Car and landing operating panels have easily readable LED indicators with energysaving performance. 3
You design. We deliver. Times Square The design line Times Square carries the architecture of sophisticated residential and commercial buildings into the elevator. Create a pleasant atmosphere with colorful laminates or stainless steel. Selecting bicolor adds another dimension of creativity. Choose from three LED lighting and ceiling concepts to create plenty of light whilst saving energy. The stainless steel operating panel matches the car design. Options: Round stainless steel handrail Individual car design or bicolor finish Mirror panels on side or rear wall Car doors in different materials and colors Bellevue Finish off your architectural concept for upmarket residential or commercial buildings with an equally attractive elevator design. The car can be dressed in a warm wood appearance or decorated with elegant, glossy surfaces. Colorful laminates and stainless steel variations blend with a choice of ceiling designs with LED lighting create an exciting appearance. The operating panel is discreetly integrated into the car. This is what we mean by elegance right down to the very last detail. Options: Round handrail Individual car floor Mirror panels on side or rear wall Car doors in different materials and colors Times Square (unicolor) Side wall /rear wall: Lisbon blue Ceiling: grey Floor: Artificial granite grey Skirting: brushed Lighting: Island Times Square (bicolor) Side wall: Lisbon blue Rear wall / ceiling: grey Floor: Artificial granite grey Skirting: brushed Lighting: Island Bellevue Side wall /rear wall: brushed Ceiling: mirror polished Floor: Artificial granite black Skirting: brushed Lighting: Square Handrail: Round 4
Times Square Park Avenue The perfect elevator for exclusive residences or prestigious offices. The back wall flows into the ceiling and the combination of high quality materials creates a modern atmosphere. Combine stainless steel with warm wood designs or contrast it with glossy surfaces. The elegant stainless steel operating panel perfectly complements the interior design. Three LED lighting and ceiling concepts create a secure and inviting atmosphere. An elevator just as exclusive as your building. Options: Round stainless steel handrail Individual car floor Mirror panels on side or rear wall Car doors in different materials and colors Bellevue Park Avenue Park Avenue Side wall: Arosa wood Rear wall/ ceiling: brushed Floor: Artificial granite black Skirting: brushed Lighting: Strips 5
Times Square Wall Rear wall (unicolor) Side wall (bicolor) Ceiling Rear wall (bicolor) Lighting Floor Grey Palma vanilla Island Island Black rubber Speckled Grey Valencia orange Light field* Light field* Artificial granite Black Grey Lisbon blue Spot Spot Artificial granite Grey Grey *available spring 2011 London grey Artificial granite Brown Grey Glasgow brown Prepared for customersupplied floor Grey Cadiz blue Marseille grey Dama Linen 6
Bellevue Wall Ceiling Lighting Floor Arosa wood Bellevue Sun* Black rubber Speckled Cambridge wood Bellevue Square* Artificial granite Black Lille brown Bellevue Spot* Artificial granite Grey *available spring 2011 Calais blue Artificial granite Brown Nancy violet Prepared for customersupplied floor Udine green Linen 7
Park Avenue
Catches the eye. Touches the soul. For every finish a complementary lighting design. High quality materials professionally crafted. Energy-saving long-life LED technology. Times Square, bicolor: Island Light field* Spot Times Square, unicolor: Island Light field* Spot Bellevue: Sun* Square* Spot* Park Avenue: Square spot* Strips* Spot* *available spring 2011
Touch and go. Operating panel Full height version. Elegant, discreet design. Matt glass display with easily readable fi ne-resolution red LED dot matrix. Push buttons with white surround illumination and red call confi rmation. Options: Concealed attendant control compartment Key switch Three landing mounting options for door frame and wall Landing operating panels, with position indicator and direction arrows Landing operating panels Option: Colored deco frame Car position indicator and direction arrows Car operating panel 10
Plenty of room. Plenty of comfort. A rear wall mirror in full or half car height adds dimension to the car. The spacious design of the car can be enlarged with mirrors. Choose one or two mirrors on the side wall or rear wall. Durable push buttons with or without braille. The round stainless steel handrail with discrete mounting adds comfort for the passengers. 11
MRL Planning Data EN-81 Load capacity Passengers max. Speed Travel height Number of stops max. Number of entrances Car Door Hoistway GQ VKN HQ BK TK HK Type BT HT BS TS HSG HSK* kg m/s m ZE mm mm mm mm mm mm mm mm mm 630 8 1.0 45 15 1 1100 1400 2200-3000 T2 900 2000-2300 1650 1750 1100 HK+1300 1.6 80 30 1 1300 HK+1400 800 10 1.0 45 15 1 1350 1400 2200-3000 C2 900 2000-2300 2025 1700 1100 HT+1300 1.6 80 30 1 1300 HK+1400 1000 13 1.0 45 15 1 1100 2100 2200-3000 T2 900 2000-2300 1650 2450 1100 HK+1300 1.6 80 30 1 1300 HK+1400 2.5 100 36 1700 2475 1800 HK+1900 13 1.0 45 15 1 1600 1400 2200-3000 C2 900 2000-2300 2125 1700 1100 HK+1300 1.6 80 30 1 1300 HK+1400 2.5 100 36 2200 1725 1800 HK+1900 1275 17 1.0 45 15 1 1200 2300 2200-3000 T2 1100 2000-2300 1975 2700 1100 HK+1300 1.6 80 30 1 1200 HK+1400 2.5 100 36 2000 2700 1850 HK+2050 17 1.0 45 15 1 1650 1700 2200-3000 C2 1100 2000-2300 2400 2025 1100 HK+1300 1.6 80 30 1 1200 HK+1400 2.5 100 36 2450 2050 1850 HK+2050 1600 21 1.0 45 15 1 1400 2400 2200-3000 C4 1300 2000-2300 2175 2800 1100 HK+1300 1.6 80 30 1 1200 HK+1400 2.5 100 36 2225 2800 1850 HK+2050 21 1.0 45 15 1 2100 1600 2200-3000 C2 1100 2000-2300 2675 1925 1100 HK+1300 1.6 80 30 1 1200 HK+1400 2.5 100 36 2700 1950 1850 HK+2050 1800 21 1.0 45 15 1 2100 1800 2200-3000 C2 1200 2000-2300 2750 2125 1500 HK+1700 1.6 80 30 1550 HK+1750 2.5 100 36 2775 2150 1850 HK+2150 GQ Load capacity BK Car width T2 Telescope door BS Shaft width VKN Speed TK Car depth C2/C4 Center-opening TS Shaft depth HQ Travel height HK Car height telescope door HSG Shaft pit depth BT Door width HSK Clear overhead below lifting beam HT Door height * with balustrade of 700 mm on car top HEmin = HT + 450 mm HK = HT + min. 100 mm Remarks: Our equipment is designed to withstand a temperature range of 5 to 40 C To achieve a suitable temperature for service personnel, the shaft temperature should be kept within the range of 5 to 35 C The humidity in the shaft should not exceed 90% in monthly average and 95% in daily average without condensation Table of dimensions as per EN81, for other country codes and specific requirements (eg. EN81-72 fire fighter elevator), please contact our local sales office Shaft dimensions width & depth are based on clear dimension +/-25mm horizontal tolerances over the total shaft height (for shaft height > 80 m, a horizontal tolerance of +/-40mm applies) All given information is for general reference and planning. For specific construction detail, please contact our local sales office 12
Height and plan view F.F.L. HQ F.F.L. HT F.F.L. HSG HE min HSK HK HT One-sided entrance TK TS TK TS BT BK BS One-sided entrance Telescopic door BT BK BS One-sided entrance Center-opening telescope door For additional information, such as proposals, constructions plans, and pricing, please contact our Sales Department directly. F.F.L. = Finished Floor Level 13
Our new one. Your next one. For further details, and all the places where you can meet your nearest Schindler consultant: www.schindler.com PLM-CUST.5500.EN.12.10 EU