Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Similar documents
Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

MEMS Gauge Pressure Sensor

Pressure Sensor/PS-A (ADP5)

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

PS-A PRESSURE SENSOR PS-A (ADP5) (built-in amplification and temperature compensating circuit)

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure sensor with built-in amplification and temperature compensation circuit

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch (Hinged Type)

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Small Type High-Speed Response POL DC-DC Converter BSV-nano Series

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

MPM160 Pressure Sensor

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Applications. Output Voltage (V) V21 = 2

Subminiature Basic Switch

Rotary Position Sensors

Ordering Information. Text Surface-Mounting Signal Relay G6K

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Ordering Information. Text PCB Power Relay G5LE

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

TOL-32EUG3W9-A. LED Lamp 2015/04/14 DL2EF3YG103-N J.F.FENG J.F.FENG Q.Y.HUANG

AM1 (NZ BASIC) SWITCHES


CONDUCTIVE POLYMER ALUMINUM SOLID CAPACITOR

Selection Guide Automotive Relays

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

FEATURES AND BENEFITS

Ratings 0402 inch size : Type ERBRD ERBRD R X 0R25 0R3 0R37 0R50 0R75 R00 R25 R50 2R00 2R50 3R00 Rated Current (A)

B3F. Miniature, Space-saving Switch

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Precautions on the use of Multilayer Ceramic Capacitors

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Mechanical Key Switch

Metal Film Fuse Resistors

DC-DC Converter DATA Sheet

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Differential Pressure Transmitter

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

COMPACT FLAT SIZE FOR AUTOMOTIVE


Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

The MiCS-2714 is a compact MOS sensor.

Applications. Car audio. Robo

COMPACT FLAT SIZE FOR AUTOMOTIVE

Model Pressure range ON/OFF output Linear output

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

Technical Information Solid State Relays. Glossary. Solid State Relays

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

High-power Solid State Relays G3PH

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

Model Number Structure

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

Cylinder Type Lithium Ion Capacitors LIC2540R3R8207

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Notice for TAIYO YUDEN Products

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

SA Series Breaker (Surface Mount Thermal Cutoff Device)

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

DC/DC Converter Application Information

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

SA Series Breaker (Surface Mount Thermal Cutoff Device)

TURQUOISE STROKE SWITCHES

Model Number Structure

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Inductive Proximity Sensor

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

E2K-L. Liquid Level Sensor. Applications. Ordering Information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

SL (AZ3) Micro Limit Switches

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

Transcription:

MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics that are superior to capacitive type pressure sensors. 0 to 37 kpa pressure range. Low Power consumption of 0.2 mw Low Temperature Influence RoHS Compliant Ordering Information Standard Models with Surface mount package Classification Structure Packaging Model Bottom Port Type SOP Plastic sleeve 2SMPP-02 Terminal Arrangement Vout (+) Non Conneted GND Icc Nsub Vout ( ) Application Examples Medical equipment Home appliance Air movement control Level indicators Leak detection Pressure controller MEMS Gauge Pressure Sensor 2SMPP 35

Specifications Ratings Item 2SMPP-02 Pressure type Gauge Pressure Sensing type Piezo Resistive Applicable gases Air (Non-corrosive, dust free) Ratings Pressure range 0 to 37 kpa Withstand pressure Max. 53 kpa Supply current 100 μadc Current consumption Max. 130 μadc Ambient operating temperature 0 to 50 C (with no icing or condensation) Ambient operating humidity 15 to 90%RH (with no icing or condensation) Ambient storage temperature 30 to 85 C (with no icing or condensation) Ambient storage humidity 10 to 95%RH (with no icing or condensation) Note: 1. The above values are initial values measured at ambient temperature condition of 23 C. 2. Please avoid caustic gases. 3. Standard product is not calibrated for negative pressures. Electrical Characteristics Item Bridge resistance Offset voltage (See note 2.) Span voltage (See note 2.) Non-Linearity (See note 2.) Hysteresis (See note 2.) Temperature influence of Span Temperature influence of Offset 2SMPP-02 20 ± 2 kω 2.5 ± 4.0 mv 31.0 ± 3.1 mv (at 37 kpa) 0 ± 0.8%FS (0 to 37 kpa) 0 ± 0.5%FS (0 to 37 kpa) 0.5 ± 1.0%FS (at 0 C) 0.3 ± 1.0%FS (at 50 C) 0 ± 3.0%FS (0 to 25 C) 0 ± 3.0%FS (25 to 50 C) Note: 1. The above values are initial values measured at ambient temperature condition of 23 C. 2. Not including temperature influence. Environment Characteristics Item 2SMPP-02 Vibration resistance Destruction 10 Hz to 500 Hz 10 G Malfunction 10 Hz to 500 Hz 10 G Shock resistance Destruction 15 G Malfunction 15 G Life Expectancy 300,000 Operations min. (0 to 39 kpa) ESD 1000 V (Human body model) Weight 0.17 g Package Material PPS (Polyphenylenesulfide) 36 MEMS Gauge Pressure Sensor 2SMPP

Engineering Data (for reference) Output Characteristics Rated Pressure vs. Output Voltage 40 35 30 Output Voltage [mv] 25 20 15 10 5 0 5 0 10 20 30 40 50 Rated Pressure [kpa] Note: 1. Ambient temperature condition: 25 C 2. Drive current: 100 μa 3. These output voltage characteristics are measured with tester without a mounting board. 4. The output voltage characteristics may be influenced by the mounting board. Be sure to check operation including durability in actual equipment before use. Temperature influence of Span voltage 2.0 Temperature influence of Offset voltage 2.0 Temp. Influence of Span Voltage [%FS] 1.5 1.0 0.5 0.0 0.5 Temp. Influence of Offset Voltage [%FS] 1.5 1.0 0.5 0.0 0.5 1.0 1.5 1.0 10 0 10 20 30 40 50 60 Temperature [ C] 2.0 10 0 10 20 30 40 50 60 Temperature [ C] Note: 1. Measured points are 0 C and 25 C, 50 C 2. Drive current: 100 μa 3. These output voltage characteristics are measured with tester without a mounting board. 4. The output voltage characteristics may be influenced by the mounting board. Be sure to check operation including durability in actual equipment before use. MEMS Gauge Pressure Sensor 2SMPP 37

Pressure cycle range (0 to 40 kpa) 1 1 Offset voltage range [%FS] 0.5 0 0.5 Span voltage range [%FS] 0.5 0 0.5 1 0 100000 200000 300000 Pressure cycle Note: 1. Tested temperature condition: 25 C 2. Number of pressure cycle time: 3 x 10 5 3. Rated cycle pressure: 0 to 40 kpa 4. These output voltage characteristics are measured with tester without a mounting board. 1 0 100000 200000 300000 Pressure cycle Example of application circuit for MEMS Pressure Sensor VDD Constant current circuit unit Amplifier circuit unit + Pressure Sensor + + Vout + 1. The pressure sensor is designed to convert a voltage by means of constant current drive. 2. Please amplify the output voltage of the pressure sensor by using the amplifying circuit if necessary. 38 MEMS Gauge Pressure Sensor 2SMPP

Dimensions Note: All units are in millimeters unless otherwise indicated. 2SMPP-02 4.75 4.00 3 #1 0.25±0.05 φ3.80 φ0.62 6.15 5.40 9.85 3.20 A 4-R0.50 4 6 1.27 0.40 1.27 x 2 = 2.54 1.00 2.00 The tolerance is ±0.3mm unless otherwise specified. 2.80 1.50 1.00 4.75 (1.10) φ1.80 φ2.60 Top view 1 Vout (+) 6 Icc 2 NC 5 N-sub 3 GND 4 Vout (-) Marking 0.75 5.45 0.10 0.90 1.125 1.125 0.45 P P 0 2 5 6 7 8 4.05 (0.90) 1.65 3.30 1.65 (1.075) LOT NUMBER MEMS Gauge Pressure Sensor 2SMPP 39

Precautions Precautions for Correct Use Handling Only air can be used as pressure media on the products directly. It is prohibited to use pressure media including corrosive gases (e.g. organic solvents gases, sulfur dioxide and hydrogen sulfide gases), fluid and any other foreign materials. The products are not water proof. Please keep dry in use. Don't use the products under dew-condensing conditions. Frozen fluid on sensor chips may also cause fluctuation of sensor output and other troubles. Don't put foreign materials (e.g. a wire or pin) into connecting tube. It may cause breakage of pressure sensor chips or fluctuation of sensor output caused by clogging the tube. Use the products within rated pressure. Usage at pressure out of the range may cause breakage. Don't use under high-frequency vibration including ultrasonic wave. The products may be broken by static electricity. Charged materials (e.g. a workbench and a floor) and workers must provide measures against static electricity, including ground connection. Overpowering terminals may deform them and detract their solderability. Don't drop or handle the products roughly. Don't use the products under humid or dusty condition. Terminals connection of pressure sensors must be handled as directed by a connection diagram. Environmental Conditions for Transport and Storage It is prohibited to keep the products with corrosive gases (e.g. organic solvents gases, sulfur dioxide and hydrogen sulfide gases). The products are not water proof. Please keep dry during storage. An anti-static treatment has been applied to the sleeves. Please note the following points. 1. Getting wet may remove an anti-static treatment and eliminate its effect. 2. The sleeves may feel sticky under hot and humid condition due to the nature of the anti-static treatment. 3. Anti-static has aging degradation. It is prohibited to keep the sleeves for more than six months. The sleeves are also nonreusable. Don't keep the products under humid or dusty condition. Mounting Use lands on the printed-circuit boards to which the sensor can be securely fixed. Fix pin No.2 on the printed-circuit boards, not fixed causes fluctuation of sensor output signals. Soldering Due to its small size, the thermal capacity of the pressure sensor is low. Therefore, take steps to minimize the effects of external heat. Dip soldering bath: Max.260 C, within 10 sec. Soldering iron: Max. 260 C, within 10 sec. Do not heat the case of sensor package, heat only terminal. Use a non-corrosive resin type of flux. Since the pressure sensor chip is exposed to the atmosphere, do not allow flux to enter inside. Cleaning Since the pressure sensor chip is exposed to atmosphere, do not allow cleaning fluid to enter inside. Avoid ultrasonic cleaning since this may cause breaks or disconnections in the wiring. Coating Do not coat the pressure sensor when it is mounted to the print circuit board. Do not wash the print circuit board after the pressure sensor is mounted using detergent containing silicone. Otherwise, the detergent may remain on the surface of the pressure sensor. 40 MEMS Gauge Pressure Sensor 2SMPP

MEMS Gauge Pressure Sensor 2SMPP MEMO

All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X305-E-1a 09/11 Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Printed in USA MEMS Gauge Pressure Sensor 2SMPP