GRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions

Similar documents
S range kw GRUNDFOS WASTEWATER

Multilift M, MD, MDV, and MD1 ranges

GRUNDFOS WASTEWATER. Super-heavy-duty submersible sewage and raw water pumps

AMD, AMG, and AFG ranges GRUNDFOS WASTEWATER

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

SE M.C.N.51D

Position Qty. Description Single Price 1 SEV B

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

Position Qty. Description Single Price

Sewage transport Submersible pumps

Dewatering Submersible sewage pumps

GRUNDFOS PRICE LIST 2017 WASTEWATER. Effective date: January 1, 2017

ABS submersible sewage pump AFP

Series description: Wilo-Drain MTC

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

SUBMERSIBLE SEWAGE PUMPS WITH SEMI-VORTEX IMPELLER in cast iron

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

Jansen Pompentechniek T: +31(0) E:

SUBMERSIBLE PUMP RANGE

MYERS MODELS 4R AND 4RX

MYERS MODELS 4RC AND 4RCX

Design details Design. Installation types. Shaft seal. Impeller type. Drive. Bearings

Dewatering pumps for raw water pumping. / / grundfos DW RANGE

Submersible Grinder Pumps Type ABS Piranha

GRUNDFOS DATA BOOKLET. Multilift. Lifting stations 50 Hz

SUBMERSIBLE SEMI-VORTEX SEWAGE PUMPS

MYERS 4VCDP. 4" Solids Handling

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Rangess AK, KXAKX Discharge Size DN 200 DN

DRD - DRS - DRF. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron

waste water and sewage pumps

Ama Porter. 50 Hz. Submersible motor pumps

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (VORTEX) in cast iron

Series description: Wilo-Drain STS 40

Submersible Motor Pump. Amarex N. 60 Hz. Type Series Booklet

VOGEL - Sewage Pumps Design KS, Channel Type Pumps Design W, WTS, Vortex Type Pumps

blue series bluepro series

Flygt 2600 sludge pump series MAXIMIZE UPTIME WITH VERSATILE SUBMERSIBLE PUMPS

JUNG PUMPEN MULTICUT SEWAGE PUMPS

Submersible Sewage Pumps Type ABS XFP

MYERS MODELS 4VC & 4VCX

MYERS MODELS 4V AND 4VX

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

50 Hz PX CHANNEL 1. Performance curves. data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s. Tolerances acc.

MTB /183 A-F-A-BQQV 400D-2 11kW

Submersible Mixer. Amamix. 60 Hz. Type Series Booklet

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

DWK.E D.R

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

Unilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)

Contents Project: Model: Chk d: Date:

Submersible Sewage Pumps Type ABS XFP

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

GR NDER PUMPS. Technical Catalog

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

MYERS MODELS 6VC & 6VCX

SE1 50, 80, 100 SEV 65, 80, 100

50Hz. water solutions. E SerieS DGE DRE GRE APE

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

MD x230V. Grundfos Pump GRUNDFOS DATA BOOKLET

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

DRS. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

Ebara Submersible Sewage Pumps (Single Channel Impeller)

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Flygt 2600 sludge pump series. Maximize uptime with versatile submersible pumps

MODEL Kg H x W x L mm LM/HM kw CODE PRICE

DML - DMLV. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron 3,7 5,5 7, LM 80 OUTPUT DIAMETER 80

MD x400V. Grundfos pump GRUNDFOS DATA BOOKLET

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Data sheet. KRTF /24XEG-S IE3 Version no.: 3. Operating data. Design. Driver, accessories

JUNG PUMPEN compli 100 MC Sewage lifting stations

- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30.

TRITUS. Submersible pumps with grinder

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (SINGLE CHANNEL) in cast iron

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Series description: Wilo-DrainLift KH 32

SPECIFICATION PUMP. DW - G 2 UNI ISO 228 Flange

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

GY/UY GRINDER / VORTEX SERIES

50 Hz. GLS - GLV Series SUBMERSIBLE WASTEWATER PUMPS. Cod Rev

DGN. Set-back vortex impeller. submersible pumps PRODUCT CATALOGUE General characteristics

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Heavy duty submersible slurry pumps

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART DW 204 PERFORMANCE CHART DW VOX 205

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

GRUNDFOS DATA BOOKLET SP A, SP. Submersible pumps, motors and accessories 50 Hz

Series description: Wilo-Drain TM/TMW/TMR 32

MODEL 7ASX-8 SPECIFICATION

MTB /158 A-F-A-BQQV 400D-2 5,5kW

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

Submersible motor pumps DN Hz

Transcription:

GRUNDFOS WASTEWATER S range 1.65 5.0 kw 50 and 60 Hz versions

Grundfos Powerful pumps for handling unscreened raw sewage Grundfos offers a complete range of highly dependable, powerful sewage pumps, designed for handling unscreened raw sewage. With more than forty years experience in providing specialised pumps and pumping equipment for all kinds of wastewater and sewage, we know better than anyone what our customers demand from a wastewater pump. > High pump efficiency over time Advanced technology makes the Grundfos pumps extremely efficient and highly dependable. Innovative features such as SmartTrim adjustment of the impeller clearance ensure long-term high pump efficiency and low life-cycle costs. > Less down time The inherent non-clogging design of our SuperVortex impeller pumps and the excellent solids handling capability of our channel impeller pumps guarantee maximum up time and substantial reduction in service costs caused by pump jamming or clogging. > Life-long reliability The Grundfos wastewater pumps are of a wellproven design that ensures life-long reliability even under the most difficult operation conditions. At Grundfos we strive to maintain a close dialogue with our customers in order to constantly improve our pump designs and performance. Only this way are we able to build the long-lasting relationships on which our business is founded. 2 >

Installation options Submerged installation on auto-coupling, types S and C Submerged installation on auto-coupling system requires a base plate with a 90 bend, fixed to the bottom of the pit. When lowered into the pit along the guide rails, the pump automatically connects to the base plate. The flexible neoprene SmartSeal ensures a leak-proof connection between the pump and the auto-coupling. Type S: To prevent sedimentation of sludge at intermittent operation, we recommend a stop level corresponding to the top of the pump housing. For sufficient cooling at continuous operation, the liquid level must be kept above mid-motor level at all times. Type C: Motor cooling is independent of the pumped liquid level. Submerged installation, portable, types S and C Certain applications, such as construction sites, require portable submersibles. Where a portable submersible is required, hoses of varying lengths and materials can be supplied. Type S: To prevent sedimentation of sludge at intermittent operation, we recommend a stop level corresponding to the top of the pump housing. For sufficient cooling at continuous operation, the liquid level must be kept above mid-motor level at all times. Type C: Motor cooling is independent of the pumped liquid level. Vertical dry installation, type D The Grundfos sewage pumps can be installed vertically or horizontally to suit specific application arrangements. The pumps are 100% watertight, allowing for dry installation with the workspace around the pump remaining clean and dry. If an unexpected flooding should occur, the Grundfos pumps are fully flood-proof. Motor cooling is effected by internal cooling of the pump. Horizontal dry installation, type D Horizontal dry installation improves the overall efficiency of the pumping system as unnecessary components and bends are avoided. As the system takes up slightly more space than a vertically installed pump, the feasibility of horizontal dry installation depends on the floor space available. Motor cooling is effected by internal cooling of the pump. 3 >

Grundfos SuperVortex impellers A unique impeller design The unique design of the Grundfos SuperVortex impellers provides high pumping efficiency and less downtime. With a flow range from 4 l/s, the Grundfos SuperVortex-impeller pumps are the optimum solution for all small pumping stations. No clogging or jamming In a SuperVortex-impeller pump, the flow is entirely outside the impeller. The design of the impeller ensures that long fibres, rags, etc. pass freely through the pumps without getting caught and without causing clogging or jamming. This means less downtime and, consequently, reduced service costs and higher pumping efficiency. The design of the SuperVortex-impeller pumps also prevents the common problem of jamming between wear rings. A Grundfos SuperVortex- impeller pump needs no wear rings! Conventional vortex impeller In pumps fitted with a conventional vortex impeller, turbulent disturbance is liable to form around the impeller. This will disrupt the flow pattern and result in lower pumping efficiency and reduced head. Grundfos SuperVortex impeller The liquid passes freely outside the impeller without any turbulent disturbance. Full performance curve without operating limitations and vibrations Due to the special power characteristics of the Grundfos SuperVortex-impeller pumps, it is possible to run the pumps right up to the maximum flow on the curves without any risk of overloading the motor. The steep performance curve means minimal flow fluctuation with varying heads. 4 SuperVortex >

Grundfos channel impellers Large free passage for superior solids handling Compromising on the ability to handle solids in order to obtain higher pumping efficiency substantially increases the risk of clogging. More clogging means more downtime and increased operating costs. The Grundfos channel-impeller pumps provide high efficiency and excellent non-clogging capabilities. The channel impellers are designed with a large free passage Ø 80 mm. Self-cleaning impeller On Grundfos wastewater pumps smaller than 12 kw, the bottom part of the channel impellers feature specially designed auxiliary vanes. These vanes are designed to create a powerful flow that keeps the clearance between the impeller and the pump housing free from solids or fibres. Semi-axial impeller design with long vane The length of an impeller vane is a key factor in determining the length of fibres that can pass through a pump without getting caught. The Grundfos channel impellers are of a semi-axial design with extra long vanes. This provides maximum performance and eliminates problems with fibres or rags getting caught in the impeller. 5 Channel impellers >

Performance overview and general data H [m] 30 20 15 10 8 6 4 3 Performance overview 1 2 3 2 2 3 4 5 6 8 10 15 20 30 40 Q [l/s] 10 20 30 40 50 60708090 100 Q [m 3 /h] Type Key The S pumps are identified by the type code stated in the confirmation of order and other documentation supplied with the pump. The code consist of the items shown in the table below. 1 SuperVortex impeller ranges 34 42 2 SuperVortex impeller range 42 3 Channel impeller range 42 Operating conditions and maximum starting frequency application is restricted by the following limits: Maximum ambient temperature and pumped liquid temperature: +40 C Storage temperature range: 30 C to +60 C Maximum installation depth: 20 m Voltage tolerances: 60 Hz 380 V - +/ 10% 50 Hz 400-415 V - +/ 10% starting frequency should not exceed 15 starts per hour. For short periods of time, a starting frequency of up to double the recommended is permissible. Material specifications Part Material DIN W.-Nr/EN AISI/ASTM Stator housing Cast iron EN-JL1040 A48 30 housing Cast iron EN-JS1050 A48 30 Impeller S1 Cast iron EN-JL1040 A48 30 Impeller SV Cast iron EN-JL1040 80-55-06 Shaft Stainless steel 1. 4460 329 Bolts & Nuts Stainless steel 1. 4436 316 O-rings NBR - - O-rings Shaft seal FMK - - Bearings Primary shaft seal Secondary shaft seal Heavy-duty Pre lubricated - - SiC/SiC - - SiC/Carbon - - Lifting bracket Stainless steel 1. 4408 316 Cables EPDM, length 10 meter - - Cable Entry PA or Cast iron - - Surface Protection Two component Epoxy - - Oil SAE 10 W 30 - - 6 Technical data >

Performance curves SuperVortex impeller 34 SV024CH SV 50 Hz SuperVortex impeller 42 SV044DH SV 50 Hz SV024C SV034DH SV014C SV044D SV014CL SV034D H [m] 24 22 20 18 SuperVortex impeller 42 Single Channel impeller 42 SV042D SV032D SV 50 Hz ISO 9906 Annex A S1044DH S1 50 Hz 16 14 12 10 8 S1034DH S1024DH 6 4 9 10 2 0 0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s] 0 10 20 30 40 50 60 70 80 Q [m 3 /h] 7 Performance >

Performance curves SuperVortex impeller 34 SV034C SV024C SV014C SV014CL SV 60 Hz SuperVortex impeller 42 SV052D SV034DH SV054DH SV044DH SV 60 Hz Channel impeller 42 S1 60 Hz S1054DH S1034DH 8 Performance >

Technical data Frame size 34 and 42. Standard and Atex versions 50 Hz 400 415 V Installation Curve Product No. Standard Product No. ATEX (A) 1) P 1 (kw) P 2 (kw) Poles I N (A) I S (A) Starting method Cos Fi Cable length (m) Impeller type Max. solids (mm) Inlet DN Discharge DN Weight (kg) Type S (submerged) Type C (cooled) Type D (dry) SV(A)014CL 1 34 96249067 96249071 2.3 1.7 4 4.4 27.7 Direct on-line (DOL) 0.75 10 SuperVortex ø80 100 80 74 x x x SV(A)014C 2 34 96249068 96249072 2.3 1.7 4 4.4 27.7 0.75 ø80 100 80 74 x x x SV(A)024C 3 34 96249069 96249073 2.3 1.7 4 4.4 27.7 0.75 ø80 100 80 74 x x x SV(A)024CH* 4 34 96249070 96249074 3.4 2.5 4 5.8 26.7 0.84 ø80 100 80 74 x SV(A)034D 5 42 96249118 96249127 3.6 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x x x SV(A)044D* 6 42 96249119 96249128 3.6 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x SV(A)034DH 7 42 96249120 96249129 5.3 4.2 4 9.2 46.0 0.84 ø80 100 80 105 x x x SV(A)044DH* 8 42 96249121 96249130 5.3 4.2 4 9.2 46.0 0.84 ø80 100 80 105 x SV(A)032D 9 42 96249122 96249131 4.4 3.5 2 7.1 58.2 0.89 ø80 100 80 105 x x x SV(A)042D* 10 42 96249123 96249132 5.9 4.7 2 9.2 58.0 0.92 ø80 100 80 105 x S1(A)024DH 11 42 96249115 96249124 2.9 2.9 4 7.0 47.6 0.76 Channel ø80 100 100 105 x x x S1(A)034DH 12 42 96249116 96249125 2.9 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x x x S1(A)044DH* 13 42 96249117 96249126 5.3 4.2 4 9.2 46.0 0.84 ø80 100 100 105 x *) Only to be used for submerged installation. (Version S only). 1) ATEX Aproval IIG / Exd. Temperature Class T4. 60 Hz **) 380 V Installation Curve Product No. Standard Product No. ATEX (A) 1) P 1 (kw) P 2 (kw) Poles I N (A) I S (A) Starting method Cos Fi Cable length (m) Impeller type Max. solids (mm) Inlet DN Discharge DN Weight (kg) Type S (submerged) Type C (cooled) Type D (dry) SV(A)014CL 1 34 96249092 96249104 2.9 2.2 4 5.5 34.1 Direct on-line (DOL) 0.79 10 SuperVortex ø80 100 80 74 x x x SV(A)014C 2 34 96249095 96249107 2.9 2.2 4 5.5 34.1 0.79 ø80 100 80 74 x x x SV(A)024C 3 34 96249098 96249109 2.9 2.2 4 5.5 34.1 0.79 ø80 100 80 74 x x x SV(A)034C* 4 34 96249101 96249112 4.3 3.2 4 7.7 33.9 0.86 ø80 100 80 74 x SV(A)034DH 5 42 96249191 96249212 4.0 3.3 4 8.1 58.3 0.76 ø80 100 80 105 x x x SV(A)044DH 6 42 96249194 96249215 4.0 3.3 4 8.1 58.3 0.76 ø80 100 80 105 x x x SV(A))054DH* 7 42 96249197 96249218 6.0 4.8 2 10.8 58.3 0.84 ø80 100 80 105 x SV(A)052D* 8 42 96249200 96249221 6.3 5.2 2 10.5 70.4 0.92 ø80 100 80 105 x S1(A)034DH 9 42 96249182 96249203 4.0 3.3 4 8.1 58.3 0.76 Channel ø80 100 100 105 x x x S1(A)054DH* 10 42 96249188 96249209 6.0 4.8 4 10.8 58.3 0.84 ø80 100 100 105 x *) Only to be used for submerged installation. (Version S only). **) Also availible as 220 and 460 V in 60 Hz version on request. 1) ATEX Aproval IIG / Exd. Temperature Class T4. 9 Technical data >

Dimensions and installation Dimensions, auto-coupling installation X2 X X1 X4 DN3 Z1 Z2 Z3 U Z4 X3 Z V M16 Z5 50 Hz Dimensions [mm] U V X X1 X2 X3 X4 Z Z1 Z2 Z3 Z4 Z5 DN3 Weight SV(A)014CL 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)014C 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)024C 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)024C 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)034D 42 805 105 670 520 110 895 2" 413 220 260 110 270 0 100 105 SV(A)044D 42 805 105 670 520 110 895 2" 413 220 260 110 270 0 100 105 SV(A)034DH 42 745 80 645 465 81 840 11 2" 345 171 220 95 160 13 80 105 SV(A)044DH 42 745 80 645 465 81 840 11 2" 345 171 220 95 160 0 80 105 SV(A)032D 42 770 90 575 425 81 770 11 2" 345 171 220 95 160 13 80 105 SV(A)042D 42 770 90 575 425 81 770 11 2" 345 171 220 95 160 13 80 105 S1(A)024DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105 S1(A)034DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105 S1(A)044DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105 60 Hz Dimensions [mm] U V X X1 X2 X3 X4 Z Z1 Z2 Z3 Z4 Z5 DN3 Weight SV(A)014CL 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)014C 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)024C 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)034CH 34 775 100 510 358 81 700 11 2" 345 171 220 95 160 13 80 74 SV(A)034DH 42 745 80 645 465 81 840 11 2" 345 171 220 95 160 13 80 105 SV(A)044DH 42 745 80 645 465 81 840 11 2" 345 171 220 95 160 13 80 105 SV(A)054DH 42 745 80 645 465 81 840 11 2" 345 171 220 95 160 0 80 105 SV(A)052D 42 770 90 575 425 81 770 11 2" 345 171 220 95 160 13 80 105 S1(A)034DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105 S1(A)054DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105 10 Technical data >

Dimensions, free-standing without accessories Y J B1 G P T1 ø19 T 50 Hz Dimensions [mm] B1 G J P T T1 Y Weight SV(A)014CL 34 805 300 515 405 355 130 R3" 74 SV(A)014C 34 805 300 515 405 355 130 R3" 74 SV(A)024C 34 805 300 515 405 355 130 R3" 74 SV(A)024CH 34 805 300 515 405 355 130 R3" 74 SV(A)034D 42 830 300 620 445 355 130 R4" 105 SV(A)044D 42 830 300 620 445 355 130 R4" 105 SV(A)034DH 42 805 300 600 425 355 130 R3" 105 SV(A)044DH 42 805 300 600 425 355 130 R3" 105 SV(A)032D 42 805 300 560 415 355 130 R3" 105 SV(A)042D 42 805 300 560 415 355 130 R3" 105 S1(A)024DH 42 825 300 620 465 355 130 R4" 105 S1(A)034DH 42 825 300 620 465 355 130 R4" 105 S1(A)044DH 42 825 300 620 465 355 130 R4" 105 60 Hz Dimensions [mm] B1 G J P T T1 Y Weight SV(A)014CL 34 805 300 515 405 355 130 R3" 74 SV(A)014C 34 805 300 515 405 355 130 R3" 74 SV(A)024C 34 805 300 515 405 355 130 R3" 74 SV(A)034CH 34 805 300 515 405 355 130 R3" 74 SV(A)034DH 42 805 300 600 425 355 130 R3" 105 SV(A)044DH 42 805 300 600 425 355 130 R3" 105 SV(A)054DH 42 805 300 600 425 355 130 R3" 105 SV(A)052D 42 805 300 560 415 355 130 R3" 105 S1(A)034DH 42 825 300 620 465 355 130 R4" 105 S1(A)054DH 42 825 300 620 465 355 130 R4" 105 11 Technical data >

Dimensions and installation Dimensions, dry vertical on base stand E C B S1 S S2 K3 K2 K4 K DN4 ø19 K1 M16 50 Hz Dimensions [mm] B C E K K1 K2 K3 K4 S S1 S2 DN4 Weight SV(A)014CL 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)014C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)024C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)034D 42 1045 455 300 341 106 136 478 95 255 311 198 100 105 SV(A)034DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105 SV(A)032D 42 1025 415 260 341 106 136 463 55 255 311 198 100 105 S1(A)024DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105 S1(A)034DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105 60 Hz Dimensions [mm] B C E K K1 K2 K3 K4 S S1 S2 DN4 Weight SV(A)014CL 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)014C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)024C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74 SV(A)034DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105 SV(A)044DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105 S1(A)034DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105 12 Technical data >

Dimensions, dry horizontal installation A1 H DN2 R 3 /8 R R1 Q2 Q1 Q ø19 R2 M16 50 Hz Dimensions [mm] A1 H Q Q1 Q2 R R1 R2 DN2 Weight SV(A)014CL 34 675 100 130 220 439 190 95 15 80 74 SV(A)014C 34 675 100 130 220 439 190 95 15 80 74 SV(A)024C 34 675 100 130 220 439 190 95 15 80 74 SV(A)034D 42 700 135 190 220 520 190 95 15 100 105 SV(A)034DH 42 665 120 130 220 520 190 95 15 80 105 SV(A)032D 42 680 110 130 220 480 190 95 15 80 105 S1(A)024DH 42 695 155 130 220 520 190 95 15 100 105 S1(A)034DH 42 695 155 130 220 520 190 95 15 100 105 60 Hz Dimensions [mm] A1 H Q Q1 Q2 R R1 R2 DN2 Weight SV(A)014CL 34 675 100 130 220 439 190 95 15 80 74 SV(A)014C 34 675 100 130 220 439 190 95 15 80 74 SV(A)024C 34 675 100 130 220 439 190 95 15 80 74 SV(A)034DH 42 665 120 130 220 520 190 95 15 80 105 SV(A)044DH 42 665 120 130 220 520 190 95 15 80 105 S1(A)034DH 42 665 155 130 220 520 190 95 15 100 105 13 Technical data >

Accessories Pos. Picture Description Dimensions DN 80 DN 100 Product number 1 Auto-coupling system complete with guide claw, base plate and upper guide-rail holder. With gaskets and bolts.cast iron, epoxy-coated. DN 80 96090993 DN 80/DN 100 96102240 DN 100 96090994 2 Ring stand with flanged 90 elbow and hose connection. With bolts, nuts, gaskets and anchor bolts.cast iron, epoxy-coated. Ring stand with flanged 90 elbow and outside thread connection. With bolts, nuts, gaskets and anchor bolts.cast iron, epoxy-coated. DN 80/DN 80/3" 96102254 DN 100/DN 80/3" 96102313 DN 100/DN 100/4" 96102255 DN 80/DN 80/R 3 96102381 DN 100/DN 80/R 3 96102382 DN 100/DN 100/R4 96102383 3 Base stand for vertical dry installation, including 90 elbow. With bolts, gaskets and anchor bolts. Galvanized steel. DN 100 96102259 4 Bracket for horizontal dry installation. With bolts, gaskets and anchor bolts. Galvanized steel. DN 100 96255509 5 6 10 adaptor with lift function for Grundfos base plate UV 35579 incl. guide claw, bolt, nuts and gasket. Adaptor for Grundfos base plate UV 35586 B incl. guide claw, bolt, nuts and gasket. 96572290 96294872 96572291 96572292 7 Lifting chain with shackle. With certificates. Galvanized steel. 6 m 96497465 8 AMD.07.18.1410 mixer for flushing in pump sump. Contact Grundfos 14 Accessories >

The Grundfos wastewater range S range 5 29 kw submersible channel-impeller pumps from 5 kw up to 21 kw and Super-Vortex pumps up to 29 kw. All designed for handling unscreened raw sewage. Available in 50 Hz and 60 Hz versions. S range 15 155 kw sewage pumps from 15 kw up to 155 kw for handling of raw sewage in heavy-duty applications. Available in 50 Hz and 60 Hz versions. S/SA ranges up to 520 kw super-heavy-duty channel pumps, axial flow pumps, and propeller pumps from 7.5 kw up to 520 kw. SE range 90 220 kw updated heavy-duty submersible sewage pumps. Includes descriptions of the new built-in sensors. SRP range 3.0 24 kw SRP submersible recirculation pumps for wastewater treatment plants and flood control. Available in 50 Hz and 60 Hz versions. SEN range 1.0 21 kw heavy-duty stainless steel pumps (SEN) for aggressive and corrosive environments. Multilift M, MD, MDV, and MD1 ranges Brochure covers Grundfos lifting stations for individual as well as multi-user applications. LC/LCD s level controllers controls for the wastewater pumping systems. AMD, AMG, and AFG ranges Brochure covers the new range of mixers and flowmakers for optimal control of liquids and solids throughout the wastewater treatment process. SEG range 0.9 4.0 kw sewage grinder pumps (SEG) for pumping of wastewater with toilet discharge. DP, EF, SE1 and SEV ranges 0.6 2.6 kw submersible channel-impeller and Super- Vortex-impeller pumps from 0.6 to 2.6 kw. Designed for handling drainage, effluent and sewage from private dwellings. Prefabricated pumping stations prefabricated pumping stations for collecting and removing drainwater, surface water, domestic and industrial wastewater and sewage. SE1 and SEV ranges 1.1 11 kw This brochure describes the innovative SEV/SE1 pump lines. Fitted with Super- Vortex or single-channel impellers, these pumps can meet approximately 80% of all wastewater pumping needs. 15 The range >