SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Similar documents
SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Commercial Sewage & Waste Water Systems

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Pump Specifications 250 Series Submersible Sump / Effluent Pump

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications FL150 Series Submersible Effluent Pump

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Pump Specifications FL100 Series Submersible Effluent Pump

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

Contents Project: Model: Chk d: Date:

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

50 Hz Products. Your Peace of Mind is Our Top Priority. Utility Pumps. Sump / Effluent Pumps. Sewage Pumps. Grinder Pumps. Specialty Products

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

Turbine STEP System SIMPLEX OR DUPLEX

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

LITERS PER MINUTE GALLONS PER MINUTE

Series MSC Sewage Chopper Pumps

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

REPLACEMENT PARTS LIST FOR MODELS:

Series 6SHM. Specifications: Series: 6SHM 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

Series 4XSHM 18 Frame Driver 3" Spherical Solids Handling

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

Series 4XSHD. Specifications: Series: 4XSHD 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

Series 4XSHV. Specifications: Series: 4XSHV , 3450RPM, 60Hz 2-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

GR NDER PUMPS. Technical Catalog

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Hydropak Booster Systems. Series motralec

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

Simplex. Specifications: EasyELECTRIC Factory Prewired Basin Package Stainless Rail with Junction Box. Basin Assemblies

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

OWNER S MANUAL Commercial Duty Pumps

Series 4SHM. Specifications: Series: 4SHM 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling. Solids Handling Submersible Pumps

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

REPLACEMENT PARTS LIST FOR GRINDER MODELS:

MODELS 7008, 7009, 7010 SUBMERSIBLE GRINDER UNITS

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

Section 200 Page 1 Effective: January 15, 2013 Supersedes: June 1, 2012

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Accessories, Controls and Package Systems

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

OWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

REPLACEMENT PARTS LIST FOR GRINDER MODELS:

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information

Thrifty Supply Company Wholesale Plumbing & Heating Supplies --

REPLACEMENT PARTS LIST FOR GRINDER MODELS:

ECC ECC Flow(USGPM) Sump & Effluent De-watering Drainage. Phase Voltage Approx Weight (lbs)

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

CARRY PUMPS CARRY MANUFACTURING, INC.

Flow Range Horsepower Best Eff. Discharge Minimum Rotation➀ GPM Range GPM Connection Well Size 5LS " CCW " CCW

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

OWNER S MANUAL 6680 SERIES SUBMERSIBLE NON-CLOG UNITS

OWNER S MANUAL MODELS 810 & 815 PROGRESSING CAVITY GRINDER PUMPS

S MANUAL 61 HD SERIES SUBMERSIBLE NON-CLOG UNITS

Your Premier Pump Choice!

CLOSED COUPLED CENTRIFUGAL PUMPS

5LS, 7LS, 10LS, 13LS, 18LS & 25LS 5-25 GPM, ½ 1½ HP, 60 HZ, SUBMERSIBLE PUMPS

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

experience when counts Pumps Systems

Submersible Turbine Pumps

Series: G5-1¼, G6-1¼ RPM - 60Hz. CAPACITIES TO 80 GPM (5 LPS) HEADS TO 135 FEET (41 M)

KW Submersible, Single-Vane Impeller

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Transcription:

Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road Louisville, KY 40211-1961 TEL: (502) 778-2731 1 (800) 928-PUMP FAX: (502) 774-3624 Visit our web site: zoellerpumps.com SECTION: 5.10.310 FM0615 1217 Supersedes 0517 SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS SINGLE SEAL 264 266 267 270 282 284 292 293 294 295 404 405 DOUBLE SEAL 4270 4282 4284 4292 4293 4294 4295 4404 4405 CAST IRON SERIES DUPLEX SYSTEM Furnish two Zoeller nonautomatic submersible pumps, Model Single Seal or Model Double Seal, with an Electrical or Mechanical Alternating System. Pumps shall have a capacity of GPM against a Total Dynamic Head of feet. Motor specification: voltage, cycle, phase, HP. Discharge to be 2 or 3 NPT or 4 flange (404/4404, 405/4405 only). Cord length to be feet. Pump shall be mounted on rail system with NPT or flange discharge. Pumps will pass 2 Solids (264, 266, 267, 270/4270, 282/4282, 284/4284, 292/4292, 293/4293, 294/4294, 295, 4295), or 3 Solids (404/4404, 405/4405). Pumps shall be UL listed, CSA approved, SSPMA certified, State of Wisc. approved, other (Specify ). SINGLE PHASE SYSTEM GENERAL Pump motor shall be hermetically sealed, submersible type, operating in a high quality dielectric oil for cooling the windings and for lubrication of the motor bearings and ceramic-carbon shaft seal. Single phase motor shall have internal automatically resetting, thermal overload protection. Construction shall be of cast iron with 100% baked-on powder coated epoxy finish for corrosion resistance and longer casting durability. All fasteners and external metal parts shall be of stainless steel. Impeller shall be of vortex non-clog design. (Addition noted below.) Check Applicable Series: 264 (.4 HP) model pump shall have a permanent split capacitor motor with capacitor attached to the motor. Cast iron switch case, pump housing, motor housing with plastic impeller and base. 266 (1/2 HP) model pump shall have split phase motor with current sensing, starting relay enclosed in switch housing cast iron switch case, motor housing and pump housing with plastic impeller and base. 267 (1/2 HP) model pump shall have split phase motor with current sensing, starting relay enclosed in switch housing. 270 (1 HP) model pump shall have a permanent split capacitor motor with capacitor in the switch housing attached to the pump. The impeller shall be cast bronze. Motor housing shall be cast iron. Discharge shall be a 2 female NPT hub. 4270 (1 HP) model pump with double carbon/ ceramic shaft seals shall have a permanent split capacitor motor with capacitor in the switch housing attached to the pump. The impeller shall be cast bronze. Motor housing shall be cast iron. Discharge shall be a 2 female NPT hub. The lower seal cavity shall be oil-filled. 282 (1/2 HP) 284 (1 HP) cast iron series pump shall have a permanent split capacitor motor with run capacitor and magnetic contactor (284 only) enclosed in a switch housing attached to the pump. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. 1

4282 (1/2 HP) 4284 (1 HP) cast iron shaft seals shall have a permanent split capacitor motor with run capacitor and magnetic contactor (4284 only) enclosed in a switch housing attached to the pump. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. The lower seal cavity shall be oil-filled. 292 (1/2 HP) 293 (1 HP) 294 (1-1/2 HP) 295 (2 HP) cast iron series pump shall have a permanent split capacitor motor with capacitor and magnetic contactor enclosed in a switch housing attached to the pump. The impeller shall be cast iron. Motor housing shall be cast iron and finned for extra cooling capability. 4292 (1/2 HP) 4293 (1 HP) 4294 (1-1/2 HP) 4295 (2 HP) cast iron shaft seals shall have a permanent split capacitor motor with capacitor and magnetic contactor enclosed in a switch housing attached to the pump. The impeller shall be cast iron. Motor housing shall be cast iron and finned for extra cooling capability. The lower seal cavity shall be oil-filled. 404 (2 HP) 405 (3 HP) cast iron series pump shall have a permanent split capacitor motor with capacitor enclosed in a switch housing attached to the pump. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. 4404 (2 HP) 4405 (3 HP) cast iron shaft seals shall have a permanent split capacitor motor with capacitor enclosed in a switch housing attached to the pump. The impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. The lower seal cavity shall be oil-filled. THREE PHASE PUMPS Pump motor shall be hermetically sealed, submersible type, operating in a high quality dielectric oil for cooling the windings and for lubrication of the motor bearings and carbon/ceramic shaft seal. Pump motor shall have external magnetic contactor and overload protection. All fasteners and external metal parts shall be of stainless steel. Impeller shall be of vortex non-clog design. 266 (1/2 HP) 267 (1/2 HP) Series shall have a 4-pole squirrel cage induction motor. 282 (1/2 HP) 284 (1 HP) Series shall have a 4-pole squirrel cage induction motor. The motor housing shall be finned for extra cooling capability. 4282 (1/2 HP) 4284 (1 HP) cast iron shaft seals shall have a 4-pole squirrel cage induction motor. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. The lower seal cavity shall be oil-filled. 292 (1/2 HP) 293 (1 HP) 294 (1-1/2 HP) 295 (2 HP) Series shall have a 2-pole squirrel cage induction motor. Impeller and pump housing shall be cast iron. The motor housing shall be finned for extra cooling capability. 4292 (1/2 HP) 4293 (1 HP) 4294 (1-1/2 HP) 4295 (2 HP) cast iron shaft seals shall have 2-pole squirrel cage induction motor. The impeller shall be cast iron. Motor housing shall be cast iron and finned for extra cooling capability. The lower seal cavity shall be oil-filled. 404 (2 HP) 405 (3 HP) series shall have a 4-pole squirrel cage induction motor. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. 4404 (2 HP) 4405 (3 HP) cast iron shaft seals shall have 4-pole squirrel cage induction motor. Impeller and motor housing shall be cast iron. The motor housing shall be finned for extra cooling capability. The lower seal cavity shall be oil-filled. 2

ALTERNATING SYSTEM ELECTRICAL ALTERNATING SYSTEM Alternator - Single Phase A Zoeller Electrical Alternator Panel with three Variable Level Float controls shall be furnished. Panel shall be UL Listed or CSA approved and shall include an alternating circuit, separate contact relays, run lights, circuit breakers and H-O-A switches for each pump. Also included shall be a numbered terminal strip and a high-water alarm and light. Overload protection shall be furnished in the pump motor. Panel shall have NEMA rating. Electrical components sized for a Zoeller model, volt, cycle, phase, HP pump. Alternator - Three Phase A Zoeller Electrical Alternator Panel with three Variable Level Float controls shall be furnished. Panel shall be UL Listed or CSA approved and shall include an alternating circuit, separate magnetic starter with overload protection, run lights, circuit breakers, and H-O-A switches for each pump. The control panel shall include a transformer to reduce control voltage to 115 volts. Also included shall be a numbered terminal strip and a high water alarm and light. Panel shall have a NEMA-4X rating. Electrical components shall be sized for a Zoeller model, volt, cycle, phase, HP pump. Variable Level Float Controls - Single Phase or Three Phase Variable Level Float Controls shall provide automatic operation of pumps and alarm. Two controls shall close circuit for on/off operation at selected levels as required to rotate operation of pumps. The third variable level float switch shall close an override circuit to operate both pumps and to activate the alarm. The variable level float control switch shall be omnidirectional, normally open, and shall include a 20 SJOWA neoprene cord. All controls shall be fastened to a float switch mounting pipe with plastic tie mounting straps. The pipe, attached to the underside of the removable inspection plate on the basin cover, shall be furnished and installed by the contractor. ACCESSORIES/MISCELLANEOUS UNICHECK 30-0021, (Clamp Union Valve) (2 inch) full flow check valve, rated at 4.3 psi pressure (10 feet TDH) at 130 F shall be furnished to fit 2 inch ABS, PVC, CPVC, steel or copper piping. Unicheck shall have valve body and seat of PVC plastic and shall be assembled with thru bolts. Gasket and flapper shall be neoprene with brass or stainless steel backing plates and stainless steel rivet. Unicheck shall include two (2) neoprene unions and four (4) stainless steel clamps and fasteners. 30-0151 (Clamp Union Valve) 2 inch full flow check valve, shall be cast iron, shall be furnished to fit 2 inch ABS, PVC, CPVC, steel, or copper piping. Unicheck valve body, gasket and flapper shall be neoprene with brass backing plates and stainless steel rivet. Unicheck shall include two (2) neoprene unions and four (4) stainless steel clamps and fasteners. 30-0020 (2 inch) or 30-0030 (3 inch) IPS full flow compression union check valve shall be furnished. Unicheck body and compression end fittings shall be constructed of PVC. Flapper and end seals be Buna-N. Valve shall include no metallic parts. Pressure rated at 25 PSI (57 feet TDH) at 130 F. 30-0152 (2 inch) or 30-0160 (3 inch) cast iron full flow check valve with female NPT Rated 50 PSI (115 feet TDH) at 130 F. Neoprene polyester reinforced flapper with cast iron and brass backing plates and stainless steel fastener. 30-0170 (4 inch) Flanged cast iron check valve. Rated at 125 PSI steam pressure. Cast iron body, cover and case, bronze disc, stainless steel fitted, shall be installed in horizontal position. Tri-Check/Combo, 30-0101 or 30-0103. 3

SUMP BASIN A Zoeller IAPMO approved polyethylene basin,.230 inch thick, or Zoeller fiberglass basin, 3/16 inch minimum thick, inches inside diameter by inches deep shall be furnished. The basin shall include four (4) inch cast iron caulk hub inlets with anticorrosion coating. The center line of the hub(s) shall be located nine (9) inches from the top of the basin. The basin shall also include a.125 inch thick steel sump cover. Cover shall have two (2) pump installation plates and an inspection plate. Optional antiflotation ring can also be provided. Also included shall be two (2) neoprene seals for pump cords, neoprene seal for vent and discharge flanges, foam cover seal and plated steel fasteners. Cover shall include a inch vent and two (2) inch discharge flanges with mounting hardware. PIPING & POWER WIRING All piping shall be rigid and permanent in nature and shall be furnished and installed by the contractor. A unicheck shall be installed in the discharge pipe. A 3/16 vent hole shall be drilled in the discharge pipe below the check valve and pit cover to purge the system of trapped air. Power wiring shall be supplied by the electrical contractor. Power wiring for pumping system and alarm system shall be connected to separate circuits. EXTRA DUTY Where conditions require, specify extra duty for adverse operating conditions. HI TEMPERATURE PUMPS For applications up to 200 F continuous operation, specify High Temperature Zoeller Co. models. See literature on High Temperature pumps, FM2811, FM1923, and FM0807, for additional information. PUMP DISCONNECTS AND RAIL SYSTEMS Where conditions, due to safety, health and the economy of maintenance require pump disconnects or rail systems specify: 39-0002, 2 NPT Disconnect (Non-pump Supporting) 39-0004, 2 NPT Rail System (Non-pump Supporting) 39-0128, 2 x 2 Z-Rail Disconnect System, all Ductile Iron Construction 39-0129, 2 x 2 Z-Rail Disconnect System, Ductile Iron Construction w/ SS Upper Rail Bracket 39-0122, 3 x 3 Z-Rail Disconnect System, all Ductile Iron Construction 39-0123, 3 x 3 Z-Rail Disconnect System, Ductile Iron Construction w/ SS Upper Rail Bracket The Z-Rail Disconnect System is a pump support assembly consisting of a disconnect fitting, rail plate & guide and utilizes two 3/4 rail pipes that guide the pump into and out of the basin. The assembly components are made of ductile iron with an optional 304 SS upper rail support bracket.used in concrete, steel or fiberglass basins, it allows for the installation or removal of the pump from the basin at ground level without entering the basin. The disconnect fitting has a machined fit with an O-ring seal that holds up to 160 psi, being able to support pumps weighing up to 300 lbs. The 3/4 rail pipes are provided by the installer, being either galvanized steel or SS pipe. 39-0016, 4 x 4 Flanged Rail System, connected horizontally, powder coated cast iron and fitted with SS rail brackets. 2 schedule 40 rail pipes are provided by others. 4

SEWAGE DUPLEX SYSTEM WITH MECHANICAL ALTERNATOR (SINGLE PHASE) SEWAGE DUPLEX SYSTEM WITH MECHANICAL ALTERNATOR (SINGLE PHASE) "A-PAK" ALARM TRANSFORMER NOTE: A minimum of 4 of pea gravel around the outside of tank throughout the depth and underneath the tank is required. "M-PAK" MECHANICAL ALTERNATOR WITH ALARM SWITCH GATE VALVE GAS TIGHT METAL COVER FLOOR LEVEL 2" OR 3" PIPING 4" INLET HUB ALARM LEVEL OVERRIDE LEVEL (BOTH PUMPS ACITVATED) ON LEVEL BASIN 4" OF GRAVEL SEWAGE PUMP ZOELLER NONAUTOMATIC OFF LEVEL 7" DIA. STAINLESS STEEL FLOAT SK482 SK483 5

SEWAGE DUPLEX SYSTEM WITH ELECTRICAL ALTERNATOR (SINGLE OR THREE PHASE) SEWAGE DUPLEX SYSTEM WITH ELECTRICAL ALTERNATOR (SINGLE OR THREE PHASE) TOP VIEW ALARM LIGHT "E-PAK" ELECTRICAL ALTERNATOR ELECTRICAL ALTERNATOR CONTROL PANEL NOTE: A minimum of 4 of pea gravel around the outside of tank throughout the depth and underneath the tank is required. INDICATOR LAMPS TOGGLE SWITCHES GATE VALVE CORDS FOR VARIABLE LEVEL FLOAT SWITCHES INSPECTION PLATE PUMP CORD FLOAT SUPPORT FABRICATED FROM PVC OR S.S. PIPE CORD SEAL PUMP PLATE INLET HUB BASIN 5 mm (3/16 ) ZOELLER NONAUTOMATIC SEWAGE PUMP 2" NPT OR 3" NPT DISCHARGE PIPE ALARM LEVEL (BOTH PUMPS ACTIVATED) ON LEVEL ZOELLER VARIABLE LEVEL CONTROL SWITCH OFF LEVEL INLET HUB 2" OR 3" VENT BASIN COVER CHECK VALVE GATE VALVE 100 mm (4") OF GRAVEL 2" OR 3" DISCHARGE PIPE SK484 SK485 6

VALVE PUMP DISCONNECT SYSTEM PULL ROD DISCONNECT CHECK VALVE CABLE SK1531 INTERMEDIATE GUIDE RAIL BRACKET REQUIRED FOR BASIN DEPTHS GREATER THAN 10'. PUMP DISCONNECT WITH RAIL SYSTEM PULL ROD CABLE VALVE DISCONNECT RAIL CHECK VALVE SK1735 7

FLOAT TREE ASSEMBLY SHUT-OFF VALVE PVC SCH. 80 PLBG. 3/4" GUIDE RAILS CHECK VALVE Z-RAIL BASE FITTING AFD Z-RAIL DISCONNECT SYSTEM 404/405, 4404/4405 AND SEWAGE/WASTE GUIDE RAIL SYSTEMS LIFTING CABLE *INTERMEDIATE GUIDE RAIL BRACKET SHUT-OFF VALVE 4" CHECK 2" IPS VALVE SHOWN GUIDE RAILS 3/16" 4" DISCHARGE ELBOW ALARM/LAG ON OFF SK3111 SK1100 8