Accessory 44 Strip Heater. Automatic Transfer Switches. Wiring. Mounting H

Similar documents
50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Operator s Manual Series ATS Automatic Transfer Switches 600 through 1200 amps

Florham Park, NJ USA Call (ASCO) for sales or service

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Operator s Manual Series ATS Automatic Transfer Switches 30 through 4000 amp. Rating Label. Nameplate C TABLE OF CONTENTS

Florham Park, NJ USA Call (ASCO) for sales or service

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches, amps

Operator s Manual Series ACTS Automatic Closed Transition Transfer Switches 150 through 4000 amps A. Rating Label.

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches 150 through 4000 amp. Rating Label. Nameplate A

www. ElectricalPartManuals. com Operator s Manual

Catalog Number Identification with Elements Explained

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

918 Remote Control Switches

Installation Manual. E-design A Transfer Switches A

3ATS & 3NTS J-design 600 A 3ADTS & 3NDTS A Transfer Switches. Installation Manual. Installation A DANGER. Table of Contents WARNING

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

ASCO Low Voltage Automatic Transfer Switch Systems

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

TT /17c INSTALLATION INSTRUCTIONS. Introduction. Power Tools Required

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Manual Transfer Switch

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches G design 1000 through 3000 amp. Rating Label B

INSTALLATION INSTRUCTIONS

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

SAVE THESE INSTRUCTIONS

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Fan Coil Unit (FCU) Fan Motor Control

University of Houston Master Construction Specifications Insert Project Name

ASCO SERIES 185 Power Transfer Switches

Quick Connection Panel (QCP) Installation Guide

O & M Manual for the EATON Generator Ready Loadcenter

SAVE THESE INSTRUCTIONS

Instruction Bulletin. Jockey Pump Controller

Low Voltage Automatic Transfer Switch Systems

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

MODEL SCA Installation and Operation Manual Important:

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Installation and Operation Instructions

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

LC I LIPPERT COMPONENTS HYDRAULIC FULL WALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL

CTFRP Series Power Supplies

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

Quick Start Guide TS 910

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

A. Submit manufacturer's literature and technical data before starting work.

Technical Service Bulletin

Installation Instructions Electric Heaters 5 20 kw

Model 930 Power Control System Instruction Manual

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Installation Instructions Electric Heaters 5 20 kw

Self-Testing Industrial Series

Bulletin 1497A Machine Tool Transformers

ELECTRICAL. 60 Minutes

Quick Start Guide TS 910 & TS 920

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

System 350 P352AB Electronic Pressure Control Series

ACCESSORY KIT INSTALLATION INSTRUCTIONS

IDP INNOVATOR DOOR PROTECTOR. P/N _B July 2012 P/N_ _B HUSSMANN MODEL NO

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

ACCESSORY KIT INSTALLATION INSTRUCTIONS

R81EAA-2 Economizer Circuit Board

Installation Instructions

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

Unit 3 Lesson 3 Electric Circuits. Copyright Houghton Mifflin Harcourt Publishing Company

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Spectron Industrial Series

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

Wiring Diagrams (Including Accessories) (50/60 Hz)

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

OnCommand Troubleshooting Guide Hayward Industries

Y99AB-4 BASO Test Kit

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

MAGNETIC MOTOR STARTERS

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Transcription:

Accessory 44 Strip Heater for Automatic Transfer Switches Accessory 44 Strip Heater is designed to keep humidity and/or temperature within the ATS enclosure at acceptable levels. This accessory consists of a mounting bracket with strip heater, thermostat, and terminal block. A transformer with fuses is included when the power for the assembly is derived from the ATS. The 120 V ac customer powered assembly does not include a transformer. This accessory is available factory installed or in kit form. If already installed, turn the thermostat s dial to required setting. transformer with fuses heater De energize all power to the Transfer Switch before opening the enclosure. Hazardous voltage capable of causing shock, burns, or death is used in this switch. Mounting 1. After de energizing both Normal and Emergency power sources and the Load, open the enclosure door. Carefully use a voltmeter to verify that all power is de energized at the Transfer Switch power terminals 2. Hole Drilling Data Sheets are shown in this publication. They are not drilling templates. They specify locations and sizes of the strip heater assembly mounting holes for each ampere rating size ATS (not for J design). Drill two holes into the enclosure as indicated. Protect the transfer switch from metal chips when drilling the holes. Clean up all debris inside the enclosure after drilling. 3. Usethekithardwaresuppliedtomountthebracketto the inside of the enclosure. The thermostat should face the front of the enclosure after mounting the assembly. For J design ATSs refer to the installation drawing. De energize the conductors before making any connections. Open the Normal and Emergency source circuit breakers and be sure that the load is also de energized. thermostat Wiring mounting holes 1. A Mounting Data drawing is included on the back page. Select the appropriate wiring diagram and illustration according to Transfer Switch ampere rating size. If 120 V ac customer furnished power will be used, go to step 2. If power will be from the Transfer Switch go to step 3. 2. 120 V ac customer furnished power. Run the 120 V ac line into the enclosure and connect the wires to TB terminals TB 1 and TB 2 on the strip heater assembly. 3. Transfer Switch derived power. Use#14 strandedwire to make a two wire harness (not provided). Select the appropriate illustration on the Mounting Data diagram (back page) according to Transfer Switch ampere rating size. Follow it to connect the Transfer Switch to the strip heater assembly. Connect one wire from transfer switch Load terminal LA to the strip heater assembly s fuse block terminal HI; connect the other wire from Load terminal LC to terminal HF on the fuse block. Double check all wiring before continuing. Keep all wiring away from the heater surface. 4. Turn the thermostat s dial to desired setting. Then close the enclosure door. 5. After the door is closed, reenergize the ATS (close Normal and Emergency source circuit breakers and reenergize the load). If a separate 120 V ac line was used for the accessory, energize that line. To avoid burns, do not touch the heater surface which becomes hot during operation. ASCO POWER TECHNOLOGIES 50 Hanover Road, Florham Park, New Jersey 07932 USA www.ascopower.com 381339 211 H

De energize all power to the Transfer Switch before opening the enclosure. Hazardous voltage capable of causing shock, burns, or death is used in this switch. Operation 1. After de energizing both Normal and Emergency power sources and the Load, open the enclosure door. Carefully use a voltmeter to verify that all power is de energized at the Transfer Switch power terminals 2. Turn the thermostat s dial to desired setting. Then close the enclosure door. 3. After the door is closed, reenergize the ATS (close Normal and Emergency source circuit breakers and reenergize the load). If a separate 120 V ac line was used for the accessory, energize that line. thermostat dial turn counterclockwise to lower temperature turn clockwise to raise temperature To avoid burns, do not touch the heater surface which becomes hot during operation.