Installation and Operation Instructions DLP Series

Similar documents
Figure 1: WPR2 Dimensions and Hardware

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Compact Low Pressure Sensor

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Pressure Transmitter

Beck. The differential pressure transmitter for air with IP65

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Carbon Monoxide Transmitter

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Differential pressure sensor

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

BAPI-Stat 3 Room Sensor

CTE8000 / CTU8000 Series

CTE7000 / CTU7000 Series Miniature pressure transmitters

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Series 10-ZSE40A(F)/10-ISE40A

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

PRESSURE BENCH OPERATING INSTRUCTIONS

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Technical Data Sheet FT & FIT-1003 SERIES AIR VOLUME/ VELOCITY TRANSDUCERS. Features DESCRIPTION

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Industrial Pressure Transmitters

LTX RF LEVEL SENSOR. Instruction Manual

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

2-Color Display High-Precision Digital Pressure Switch

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Differential Pressure Sensors

Electric Actuator Instructions

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SAX Electronic Valve Actuator

Signet Pressure Transmitter

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

V-SENSOR LOW AIR VELOCITY SENSOR

Model 124 Filter Minder & Model 124

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

SECTION INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Type A-10 General Purpose Pressure Transmitters

2-Color Display High-Precision Digital Pressure Switch

Differential Pressure Sensors

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Differential Pressure Sensors

GE Sensing & Inspection Technologies

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

SETRA Operating Instructions Series DPT 230 Pressure Transducers

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

GE Measurement & Control

Type A-10 General Purpose Pressure Transmitter

PISTON STYLE GAUGE. Mid-West Instrument

Micro-Machined Silicon Transducers

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Signet Pressure Transmitter

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

CONTROLLERS & SPECIAL VALVES

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

MF /MS Series

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

VT-SENSOR AIR VELOCITY AND TEMP

Differential Pressure Sensors

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

OEM Pressure Transmitters

QVT MULTIVARIABLE TRANSMITTER

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Combined Ventilation Controller RVWS-T-224HA

FEATURES AND BENEFITS

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Millivolt Output Pressure Sensors

Commercial Actuator Selection Chart Non-Spring Return

1100 Series Piston Type Differential Pressure Gauges

Transcription:

Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW LIVE WIRES TO TOUCH THE CIRCUIT BOARD. AN ISOLATION TRANSFORMER IS RECOMMENDED WHEN POWERING THE DEVICE WITH 24VAC. DO NOT RUN THE WIRING IN ANY CONDUIT WITH LINE VOLTAGE. FAILURE TO WIRE DEVICES WITH THE CORRECT POLARITY WHEN USING A SHARED TRANSFORMER MAY RESULT IN DAMAGE TO ANY DEVICE POWERED BY THE SHARED TRANSFORMER. MEDIA The DLP can be used to monitor the differential pressure in any application that uses dry air or inert gas. DIN RAIL MOUNTING (Optional Accessory Ordered) Attach the DIN Rail Mounting accessory to the back of the enclosure using the two screws provided. To mount the sensor on the DIN Rail, place the bottom of the DIN Rail Clip into the 35mm DIN Rail and push the unit upward to engage the spring clip. Now press the top of the unit back until it locks into place (see Figure 2). Figure 2: DIN Rail Mounting Middleton, Wisconsin 53562 Page 1 of 6

PITOT TUBE INSTALLATION (Optional Accessory Ordered) Slip the rubber washer over the threaded end of the pitot tube, keeping the washer as close to the threaded end as possible. Fasten the pitot into the threaded insert on the back of the enclosure. Press the rubber washer against the enclosure. Figure 3: Pitot Tube Installation TUBING SETUP WHEN PITOT TUBE IS INSTALLED Units will be shipped with silicone tubing attached to the high and low pressure barb fittings. The silicone tubing will need to be removed from the High Pressure (H) barb fitting and secured onto the pitot tube barb fitting. This will leave the high pressure barb fitting open to atmosphere, and the Low pressure barb fitting remaining at default setup. Figure 4: Pitot Tube Installation MOUNTING Two size #8 x 3/4 self drilling screws are supplied. Mount the unit vertically with the brass fittings pointing towards the ground. Attach the unit to the mounting surface using the two mounting holes located on the top and bottom flanges. For best results, all tubing lengths should be limited to a maximum length of 75 feet (23 meters). PRESSURE CONNECTIONS The recommended connection tubing is ¼ O.D push-on tubing (1/8 to 3/16 I.D.). Middleton, Wisconsin 53562 Page 2 of 6

Duct Mount Panel Mount Figure 5: DLP Mounting WIRING Shielded is recommended cable with 16 to 24AWG conductors. The hinged cover must be opened to connect wires to the unit s finger push-button terminal blocks. Each DLP unit can be configured to three output signals: 4-20mA, 0-5V or 0-10V. Use the Wiring Connections (Table 1) and diagrams (Figure 7) to determine the proper wiring for your application. See Table 1 for Output Mode and Output Signal switch positions. Output Signal Output Mode Output Signal Supply Voltage Wire Connections (SW1) (SW3 Position 4) Red Black White Yellow 0-5 VDC Vout 5V VAC/VDC V+ COM VOUT n/c 0-10 VDC Vout 10V VAC/VDC V+ COM VOUT n/c 4-20 ma ma n/a VDC V+ n/c n/c IOUT n/a=not Applicable n/c=no Connection Table 1: Wiring Connections Figure 6: SW1 and SW3 Output Switches Middleton, Wisconsin 53562 Page 3 of 6

Figure 7: Wiring Connections When using ½ conduit, the strain relief fitting must be removed from the enclosure. Make sure that any conduit or metal fittings do not come in contact with the circuit board. ZERO FUNCTION The DLP unit should be ZEROED before pressure is applied to the unit. The zero button is used to cancel out any offsets caused by installation and sensor drift. The Zero adjustment must be performed with NO pressure applied to either side of the sensor. Remove the tubing connected to the H(High) and/or L(Low) pressure fittings. Push ZERO button for more than three seconds before installation or whenever necessary. For units with LCD display: AUTOZERO icon will be on when the unit enters zero mode. If zeroing process is successful, the AUTOZERO icon will flash twice. PRESSURE RANGE SELECTION If a custom calibrated range is ordered, DO NOT change Range Selection DIP switch settings. The DLP can operate in either unidirectional mode (0 X inwc) or bidirectional mode (± X inwc). Each unit could have up to eight field selectable, uni or bidirectional ranges. DO NOT SWITCH PRESSURE RANGE OR OUTPUT MODE WHEN POWER IS ON. MAKE SURE POWER TO THE UNIT IS OFF. FAILURE TO DO SO WILL NOT ALLOW ANY NEW SWITCH SETTINGS TO TAKE PLACE. CHOOSE DIFFERENTIAL RANGE BASED ON THE EXPECTED DIFFERENTIAL PRESSURE IN YOUR APPLICATION. MOVE SWITCHES TO THE CORRECT POSITIONS AND THEN POWER ON THE TRANSMITTER. MAXIMUM PRESSURE ACI Part No. Maximum Pressure (inwc) DLP-001-W 1 DLP-010-W 10 DLP-040-W 40 Middleton, Wisconsin 53562 Page 4 of 6

Unidirectional Mode DIP switch SW3 position five set at UNI side. DIP switch SW3 positions one and two are for Range Selection ACI Part No. SW3 Position 1: 1 SW3 Position 1: 2 Position 2: A Position 2: B Position 2: A Position 2: B DLP-001-W 1 inwc 0.5 inwc 0.2 inwc 0.1 inwc DLP-010-W 10 inwc 5 inwc 2 inwc 1 inwc DLP-040-W 40 inwc 30 inwc 20 inwc 10 inwc See Figure 8 Bidirectional Mode DIP switch SW3 position five set at BI side. DIP switch SW3 positions one and two are for Pressure Range Selection. Note: In Bidirectional mode, a value of 0 inwc will have an output equal to 50% of the output signal range (12mA, 2.5V, 5V). ACI Part No. SW3 Position 1: 1 SW3 Position 1: 2 Position 2: A Position 2: B Position 2: A Position 2: B DLP-001-W ±1 inwc ±0.5 inwc ±0.2 inwc ±0.1 inwc DLP-010-W ±10 inwc ±5 inwc ±2 inwc ±1 inwc DLP-040-W ±40 inwc ±30 inwc ±20 inwc ±10 inwc See Figure 8 Figure 8: PCB Layout ENGINEERING UNITS ADJUSTMENT This option is ONLY for units with LCD display. Switch DIP switch SW3 position three to select Pa or inwc. If switched with power on, unit change will not take place until power is cycled. DIAGNOSTIC OUTPUT Each DLP unit has the feature to check the pressure on the sensor. When the sensor s input pressure is out of range, the DLP will output 5.25V for a 0-5V output; 10.5V for a 0-10V output and 22mA for a 4-20mA output. If a DLP unit is outputting an out-of-range diagnostic signal, please turn off the unit immediately, and check the pressure input with a gauge or other test instrument. Once the pressure has been verified, set the Range Selection DIP switch to the proper positions based upon your maximum expected differential pressure. For units with LCD display: OUT OF RANGE icon will be on when differential pressure is over or under the minimum or maximum pressure range selected. Middleton, Wisconsin 53562 Page 5 of 6

PRODUCT SPECIFICATIONS Supply Voltage Supply Current Output Signals Response Time (0-100% FSO) Output Update Rate Pressure Ranges Accuracy¹ Zero Function Thermal Effects² Proof Pressure / Burst Pressure³ Operating Temperature Range Compensated Temperature Range Storage Temperature Range Operating Humidity Range Media Types Enclosure Material / Flammability Rating Wiring Connections Conduit Knockouts Pressure Fitting Material Tubing Size Accepted Approvals 4-20 ma Output: 16-36 VDC (250 Ohm Load max.) / 22-36 VDC (500 Ohm Load max.) 0-5 VDC / 0-10 VDC Output: 16-36 VDC / 24 VAC (+/- 10%) 4-20 ma Output: 24 ma minimum 0-5 VDC / 0-10 VDC Output: 6 ma maximum Current Output: 4-20 ma, 2-Wire Loop Powered (Standard); (Current limited to 21.4 ma max) Voltage Signals: 0-5 VDC / 0-10 VDC Field Selectable, 3-Wire; Output limited @ 5.25 & 10.5 VDC) 8 seconds 1 second See Product Ordering Grid (Data Sheet); Field Selectable Uni and Bi-Directional Ranges +/- 0.5% FSO; +/- 0.25% (Only for Specified Range) Pushbutton Zero Function +/- 0.067% FSO / F (0.12% FSO / C) A/DLP-001: Proof: 270 inwc (67.2 kpa) Burst: 415 inwc (103.3 kpa) for 1 inwc (249.8 Pa) A/DLP-010: Proof: 350 inwc (87.12 kpa) Burst: 550 inwc (136.9 kpa) for 10 inwc (2490.8 Pa) A/DLP-040: Proof: 562 inwc (140 kpa) Burst: 1004.7 inwc (250 kpa) for 40 inwc (9963.6 Pa) -4 to 185 F (-20 to 85 C) 32 to 122 F (0 to 50 C) -22 to 185 F (-30 to 85 C) 10 to 95% RH, non-condensing Dry air or inert non-conductive gases Flame Retardant Polycarbonate; UL94-5VA Finger Pushbutton (Spring) Terminal Blocks; accepts 16-24 AWG wires Watertight Cordgrip Installed (1/2" NPT Conduit fittings accepted when Cordgrip removed) Nickel Plated Brass or Stainless Steel 1/4" O.D. x 0.170" I.D. Poly Tubing CE, Reach, RoHS2, WEEE Product Weight (No Pitot Non-LCD Display Version: 0.53 lbs (0.240 kg) LCD Display Version: 0.58 lbs (0.263 kg) Tube OR Din Rail) Product Weight (With Pitot Non-LCD Display Version: 0.80 lbs (0.363 kg) LCD Display Version: 0.85 lbs (0.385 kg) Tube & Din Rail) NIST Certification 3 Point: Test Points 10%, 50%, and 90% FSO 5 Point: Test Points 10%, 30%, 50%, 70% and 90% FSO Note¹: Accuracy includes linearity, hysteresis & repeatability. Note²: Shift is relative to 77 F (25 C). Note³: "x" designates both the LCD "-D-" & Non-LCD Display "-N-" versions. WARRANTY SPECIFICATION Table 2: Product Specifications The DLP Series pressure transmitters are covered by ACI s Five (5) Year Limited Warranty, which is located in the front of ACI S SENSORS & TRANSMITTERS CATALOG or can be found on ACI s web site: www.workaci.com. Middleton, Wisconsin 53562 Page 6 of 6