AMENDMENTS Dated: August 25, 2010

Similar documents
HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Element D Services Heating Ventilating and Air Conditioning ODG010107

critical environment diffusers

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

GEA Clean Rooms. Modules with laminar air flow for ceiling installation GEA Fresh Heaven j^uu GEA Fresh Heaven j^uu=mltbo.

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Laminar ceilings, exhaust columns, exhaust grilles

OmniAire Portable Air Cleaner OA1200PAC

Ventilated Balance Enclosures

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Protector Glove Boxes.

Design Makes All The Difference...

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

nivia utilities Why Air Filters???

PLANNING THE INSTALLATION

VERSAFLOW SERIES UNIDIRECTIONAL LAMINAR AIRFLOW COMPOUNDING ASEPTIC ISOLATOR (CAI)

Filtration Solutions Edition. Fort Myers 6461 Topaz Court Fort Myers, FL Tel: (239) Fax: (239)

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

VERTICAL LAMINAR FLOW CABINETS

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

Midea Air Handling Unit

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

Element D Services Heating Ventilating and Air Conditioning ODG010107

Ceiling swirl diffusers

Class II, Biological Safety Cabinets Probably the Most Advanced Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

Price O.R. Systems AIR CURTAIN SYSTEM

MERV Filter Models for Aerobiological Applications. W.J. Kowalski, PE, PhD W.P. Bahnfleth, PE, PhD The Pennsylvania State University

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

INSTALLATION INSTRUCTIONS

High Performance Ductless Balance Enclosures

INLET FILTER ASSEMBLIES/ EXPOSED FILTERS

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

Excelair. Every filter is created to perfection!

Fume extractor is warranted for two years, parts and labor.

Affordable portable filtration unit

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

AMOUNT IN Rs After adding percentage above or at par or below In In words figures. ESTIMATED COST (IN Rupees) In figures. In words

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

Ceiling swirl diffusers

Controlled Environment Equipment Solutions for the Lab

AS , EN12469 (Microbiological Testing Method)

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

INDOOR ENVIRONMENTAL SOLUTIONS

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Mediclean Complanate Ultra Clean Ventilation

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

6-54 HEPA Filter Assembly

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

Element D Services Heating, Ventilating, and Air Conditioning

Lecture 3 : Cleanroom Technology (Contamination Control)

Specialists in HEPA Filtration and Negative Air Machines

Ceiling swirl diffusers with perforated face plate

(Class II Type A2 & B2)

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

PCR Laminar Flow Cabinets

Air Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation

TM Series MICROBIOLOGICAL SAFETY CABINETS. Technical Specifications

Photographer: BRUCE T. MARTIN, LFD Laminar Flow Diffuser

MICRO SEAL-SERIES HEPA Holding Frames and Housings

INTAKE FILTERS and FILTER SILENCERS

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Ductless Nanoparticle Containment Enclosures

Splash-proof Terminal HEPA Filter

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS)

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

MEDIUM PROFILE UNIT COOLERS Technical Guide

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Laminar Flow Clean Benches, Horizontal and Vertical

Handbook Of Microbiological Safety Cabinet Type BIO II 9 (4 ft) and 12 (3 ft)

Ductless Nanoparticle Containment Enclosures

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

CF50.0 CRITICAL FUEL SYSTEMS For Fuel Storage Up To 250,000 Gallons (946,000 liters)

BATH VENTS 2014 CATALOG. A QSSI Company

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

BC 08. Sand Trap Louvers STL-AB-11A LISTED

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Appendix A. Cooling Coil

FlowAir CATALOG.

General. Technical Bulletin: ACCESSORY INFORMATION

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

SECTION HVAC AIR CLEANING DEVICES

Smart Fume Extractor

Safety drying ovens. Advantages: Areas of application: FDL series 115

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

European Style IVC Systems

Ductless Nanoparticle Containment Enclosures

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

LAMINAR AIRFLOW EQUIPMENT

Transcription:

AMENDMENTS Dated: August 25, 2010 The Guidelines for Air Conditioning of OT as mentioned in Glossary at page no. 114-115 is replaced by following text. Air OT Conditioning The Revised Guidelines for Air-Conditioning System for Operation Theatres A. The air conditioning requirements for Operation Theater in an HCO have been deliberated at length with manufacturers, engineers, technical committee members and other stake holders and the following guidelines have been finalised. B. For this purpose operation theaters have been divided into two distinct groups: a. Superspeciality OT: Superspeciality OT means operations of Neurosciences, Orthopedics (Joint Replacement), Cardiothoracic and Transplant Surgery (Renal, Liver etc). b. General OT: This includes Ophthalmology and all other basic surgical disciplines. District hospital OTs and FRU OT would fall under this category. C. The following basic assumptions have been kept in view: OT Size: Standard OT size of 20 x 20 x 10 (Ht. below the false ceiling level is considered). Occupancy: Standard occupancy of 5-8 persons at any given point of time inside the OT is considered. Equipment Load: Standard equipment load of 5-7 kw considered per OT. Ambient temperature & humidity at each location to be considered while designing the system.

1. REQUIREMENTS Super-specialty OT I. Air Changes Per Hour: Minimum total air changes should be 30 based on international guidelines although the same will vary with biological load and the location. The fresh air component of the air change is required to be minimum 5 air changes out of total minimum 30 air changes. If HCO chooses to have 100% fresh air system than appropriate energy saving devices like Heat Recovery Wheel, Run around Pipes etc should be installed. II. III. IV. Air Velocity: The vertical down flow of air coming out of the diffusers should be able to carry bacteria carrying particle load away from the operating table. The airflow needs to be unidirectional and downwards on the OT table. The air velocity recommended as per the international and national guidelines is 90-120 FPM at the Grille/ Diffuser level. Positive Pressure: There is a requirement to maintain positive pressure differential between OT and adjoining areas to prevent outside air entry into OT. The minimum positive pressure recommended is 15 Pascal (0.05 inches of water) as per ISO 14644 Clean Room Standard. Air handling in the OT including air Quality: Air is supplied through Terminal HEPA filters in the ceiling. The minimum size of the filtration area should be 8 x 6 to cover the entire OT table and surgical team. The minimum supply air volume to the OT (in CFM) should be compliant with the desired minimum air change. The return air should be picked up/ taken out from the exhaust grille located near the floor level (appx 6 inches above the floor level). The air quality at the supply i.e. at grille level should be Class 100/ ISO Class 5 (at rest condition). Class 100 means a cubic foot of air

must have no more than 100 particles measuring 0.5 microns or larger. V. Temperature and Humidity: The temperature should be maintained at 21 +/- 3 Deg C inside the OT all the time with corresponding relative humidity between 40 to 60% though the ideal Rh is considered to be 55%. Appropriate devices to monitor and display these conditions inside the OT may be installed. VI. Air Filtration: The AHU must be an air purification unit and air filtration unit. There must be two sets of washable flange type pre filters of capacity 10 microns and 5 microns with aluminum/ SS 304 frame within the AHU. The necessary service panels to be provided for servicing the filters, motors & blowers. HEPA filters of efficiency 99.97% down to o.3 microns or higher efficiency are to be provided in the OT and not in the AHU. 2. REQUIREMENTS General OT I. Air Change Per Hour: Minimum total air changes should be 25 based on international guidelines although the same will vary with biological load and the location. The fresh air component of the air change is required to be minimum 4 air changes out of total minimum 25 air changes. II. III. Air Velocity: The vertical down flow of air coming out of the diffusers should be able to carry bacteria carrying particle load away from the operating table. The airflow needs to be unidirectional and downwards on the OT table. Positive Pressure: There is a requirement to maintain positive pressure differential between OT and adjoining areas to prevent outside air entry into OT. The minimum positive pressure recommended is 15 Pascal (0.05 inches of water)

as per ISO 14644 Clean Room Standard. IV. Air handling in the OT including Air Quantity: Air is supplied through HEPA filters in the AHU. The minimum size of the air supply area should be 6 x 4 to cover the entire OT table and surgical team The minimum supply air volume to the OT (in CFM) should be compliant with the desired minimum air change. The return air should be picked up/ taken out from the exhaust grille located near the floor level (approx 6 inches above the floor level). The air quality at the supply i.e. at grille level should be Class 1000/ ISO Class 6 (at rest condition). Class 1000 means a cubic foot of air must have no more than 1000 particles measuring 0.5 microns or larger. V. Temperature and Humidity: The temperature should be maintained at 21 +/- 3 Deg C inside the OT all the time with corresponding relative humidity between 40 to 60% though the ideal Rh is considered to be 55%. Appropriate devices to monitor and display these conditions inside the OT may be installed. VI. Air Filtration: The AHU must be an air purification unit and air filtration unit. There must be two sets of washable flange type pre filters of capacity 10 microns and 5 microns with aluminum/ SS 304 frame within the AHU. The necessary service panels to be provided for servicing the filters, motors & blowers. HEPA filters of efficiency 99.97% down to o.3 microns or higher efficiency may be provided in the AHU. 3. General Guiding Notes: a. The AHU of each OT should be dedicated one and should not be linked to air conditioning of any other area. b. During the non functional hours AHU blower will be operational round the clock (may be without temperature control). VFD devices may be used to conserve energy.

c. Window & split A/c should not be used in any type of OT because they are pure re circulating units and have convenient pockets for microbial growth which cannot be sealed. d. The flooring, walls and ceiling should be non porous, smooth, seamless without corners and should be easily cleanable repeatedly. The material should be chosen accordingly. e. Validation of system to be done as per ISO 14664 standards and to be necessarily include: Temperature and Humidity check Air particulate count Air Change Rate Calculation Air velocity at outlet of terminal filtration unit / filters Pressure Differential levels of the OT wrt ambient / adjoining areas Validation of HEPA Filters by appropriate tests like DOP etc. f. Maintenance of the system: It is recommended that periodic preventive maintenance be carried out in terms of cleaning of pre filters at the interval of 15 days. Preventive maintenance of all the parts is carried out as per manufacturer recommendations.