Magnum Mobile Generator MMG175 Specifications

Similar documents
Magnum Mobile Generator MMG330 Specifications

Mobile Generator MMG130 Specifications

Mobile Generator MMG75D Specifications

Mobile Generator MMG130 Specifications

Magnum Mobile Generator MMG75 Specifications

Magnum Mobile Generator MMG235 Specifications

Magnum Mobile Generator MMG75 SS Specifications

Magnum Mobile Generator MMG125 Specifications

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4

Specifications. Standard MMG100D** MMG130D** MDG150DF4

Mobile Generator MMG25FHI Specifications

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

customer driven unsurpassed value

Mobile Diesel. Generators

MOBILE DIESEL GENERATORS

Magnum Mobile Flip-Hood Generators Model MMG 45 (pages 4-7) Magnum Mobile Generators Model MMG 100 (pages 4 7)

Magnum Combination Unit MTT25 Specifications

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

10,000 Watt Diesel Generator AGi9P E

13,000 Watt Diesel Generator AGi13P E

DCA400SSI4F. WhisperWatt 400. MQ POWER Whisperwatt Series. Prime Rating 320 kw (400 kva) Standby Rating 336 kw (420 kva)

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

APD-ULJ250. Standby Power

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

RENTAL DIESEL GENERATOR SET

60 Hz FEATURES. Exclusively from your Caterpillar dealer

GENERATORS. Mobile Full Line

DIESEL GENERATOR SET. 60 Hz FEATURES

Trailer Mounted Light Towers

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

45 KW / 55 KVA POWERED by

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

60 Hz FEATURES. Exclusively from your Caterpillar dealer

XQ175 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

DIESEL GENERATOR SETS

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

POWERBLOCK GENERATION SYSTEMS

XQ80 RENTAL. 60 Hz FEATURES

Multiple voltage 45kVA prime power Isuzu engine

Diesel generator set QSX15 series engine

Rental Power QSB7 series engine

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

KOHLER MOBILE GENERATORS

Rental Power QSL9 series engine

Spark-ignited generator set

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

APD-NG400. NG Standby Power

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

80kW Standby / 70kW Prime Power Towable Generator

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Rental Power 800 kw. Specification sheet. Description. Features. Options

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

XQ60 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

Diesel generator set 6BT5.9 series engine

Diesel generator set QSK23 series engine

LED Runway Closure Marker RCM-D

Diesel generator set QSB7 series engine

30kW Standby / 27kW Prime Power Towable Generator

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Standby kw Prime kw

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

Bid Specifications HP935WCU PORTABLE AIR COMPRESSOR

DIESEL GENERATOR MMG130D MMG175 MMG205

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

XQ 200 R E N T A L. STANDBY 200 kw PRIME 182 kw. POWER MODULE 60Hz 1800 rpm 480V FEATURES

D I E S E L G E N E R A T O R S E T S

28 KW / 28 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

BID SPECIFICATIONS FOR (1) 300kW STANDBY GENERATOR

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS60/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR MMG120 MMG150 MMG150D MMG170 MMG185D MMG235

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Expert Design...Trusted Power

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

55 KW / 70 KVA POWERED by

Diesel generator set QSX15 series engine

WPS350/S EP Series. Features:

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

1000 KW / 1250 KVA POWERED by

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

Spark-ignited generator set

Transcription:

Customer Driven Unsurpassed Value Magnum Mobile Generator MMG175 Specifications ENGINE John Deere PE6068HFG94 - turbocharged, diesel engine o Prime - 217 hp @ 1800 rpm o Standby - 241 hp @ 1800 rpm o 6 cylinder o 6.8 L displacement o Interim Tier IV emissions Steel, single wall fuel tank o 342 gal. capacity o 29 hr. run time full load o Fuel tank built into skid of generator set Fuel consumption at prime: o 100% - 10.9 gph (41.3 Lph) o 75% - 8.2 gph (31.0 Lph) o 50% - 5.5 gph (20.8 Lph) Cooling system capable of operating at 120 F ambient Low coolant shutdown Radiator and oil drains plumbed to exterior Rubber vibration dampers isolate engine/generator from frame Disposable air filter - paper element Air filter restriction indicator mounted on control panel 60 Hz engine/generator Electronic isochronous governing Utilizes DOC / DPF exhaust filter Variable Geometry Turbocharger (VGT) GENERATOR Marathon Electric o Brushless o 4 pole o Class H insulation Voltage regulation +/- 1% with Marathon SE350 Voltage Regulator SYSTEM OUTPUT 3 Position voltage selector swith: o Three phase 120 / 208V Low Wye o Three phase 277 / 480V High Wye o Single phase 120/240V Zig Zag 153 kw / 191 kva standby, three phase 138 kw / 172 kva prime, three phase 125 kw / 125 kva standby, single phase 120 kw / 120 kva prime, single phase magnumpower.com Page 1 of 5

SYSTEM CONTROLS Power Zone controller and display o Backlit, 800 x 480 pixel resolution color display o -40 F to 185 F operating temperature range o Automatic coarse voltage adjustment o Integrated fine voltage adjustment o PLC functionality Push buttons for easy operation o Manual or Auto Start o Engine Start o Engine Stop/Reset o Alarm Mute o Operator Screens Home Engine Generator Voltage Adjust o Scrolling Arrows for Diagnostic Information Engine diagnostic display Oil pressure Engine temperature Fuel level Battery Aftertreatment inlet/outlet temperature Ash/soot levels Generator diagnostic display System kw output display Line output & frequency display Alarms Warning Shutdown Electrical Trip Engine Alarm list warnings / shutdowns 250 event history log date/time stamp Fuel level: warning 15%; shutdown 5% Overspeed protection: shutdown 115% Oil pressure: warning 25 psi; shutdown 20 psi Coolant temperature: warning 220 F; shutdown 230 F Battery voltage: over 15VDC; under 11VDC Generator over voltage: warning 110%; electrical trip 111% Generator under voltage: warning 87%; electrical trip 86% Generator over frequency: warning 105%; electrical trip 110% Generator under frequency: warning 95%; electrical trip 90% Inputs/Outputs Auto Schedule Status Configuration of controller, firmware and connections magnumpower.com Page 2 of 5

ELECTRICAL CONTROLS Remote start / stop contacts located next to lug box Lockable control box door with diagnostics window Lockable lug box with safety switch o Trips main breaker when lug door is opened o Disables voltage regulator Cable entry guides to the lug box o Restricts access of foreign objects Output ground connection lug inside lug box 700A main breaker with shunt trip Convenience receptacles with individual breakers (restricted use in high wye mode) o (2) 120V 20 Amp GFCI duplex outlets (Nema 5-20R type) o (3) 125 / 250V 50 Amp, 3 pole, 4 wire twistlock (Non-Nema 6369) Panel mounted rheostat for voltage adjustment - +/- 10% 1000 CCA wet cell battery ENCLOSURE TRAILER Aluminum, sound attenuated enclosure o UV & fade resistant, high temperature cured, white polyester powder paint o Insulated and baffled o 68 db(a) at 23 feet prime power Fully lockable enclosure including doors and fuel fill Stainless steel hinges on doors Emergency stop switch located on outside of enclosure Central lifting point Multi-lingual operating/safety decals Document holder with operating manual including AC/DC wiring diagrams DOT approved tail, side, brake, and directional lights o Recessed rear lights Transportation tie downs Safety chains with spring loaded safety hooks 3 lunette ring hitch (2) 7000 lb. axles with surge brakes 5000 lb. tongue jack with footplate ST235/80R16 tubeless tires 10 ply WEIGHTS & DIMENSIONS Skid mounted Dry weight: 6604 lbs (2996 kg) Operating weight: 9032 lbs (4097 kg) 144 x 50 x 77 in (3.66 x 1.27 x 1.96 m) magnumpower.com Page 3 of 5

Trailer mounted Dry weight: 8000 lbs (3629 kg) Operating weight: 10426 lbs (4730 kg) 210 x 86 x 93 in (5.33 x 2.18 x 2.36 m) WARRANTY Engine and generator covered under OEM warranty consult factory for details. CERTIFICATIONS CSA certified MMG175 Options ENGINE OPTIONS In-line engine block heater (Kim Hotstart) Fuel transfer pump ELECTRICAL CONTROLS OPTIONS Battery disconnect Battery charger 2A trickle GENERATOR OPTIONS PMG Generator - critical grade power quality SUPERSTART Generator - motor starting applications 157 kw / 157 kva standby, single phase 143 kw / 143 kva prime, single phase 161 kw / 201 kva standby, three phase 145 kw / 181 kva prime, three phase VOLTAGE OUTPUT OPTIONS 4 position phase switch Single phase 120 / 240V Zig Zag Three phase 120 / 208V Low Wye Three phase 277 / 480V High Wye Three phase 120 / 240V Delta Dedicated voltage configurations Buck Transformer kit - Provides 120V at GFCI outlets when in 277/480V Cam locks SYSTEM CONTROLS OPTIONS Auxiliary strobe/audible indication for soft & hard alarm conditions COOLANT OPTIONS 60/40 Coolant - cold weather applications magnumpower.com Page 4 of 5

ENCLOSURE OPTIONS Fire extinguisher Interior cabinet light Control panel light FUEL TANK OPTIONS 120% Containment TRAILER OPTIONS Tandem axle trailer w/ electric brakes 6 pin or 7 spade electrical connectors Spare tire/wheel kit magnumpower.com Page 5 of 5