International Air Pollution Prevention

Similar documents
VISWA INSTRUCTION FUEL QUALITY TESTING PROCEDURES. Viswa Lab Fuel Oil Analysis

RESOLUTION MEPC.182(59) Adopted on 17 July GUIDELINES FOR THE SAMPLING OF FUEL OIL FOR DETERMINATION OF COMPLIANCE WITH THE REVISED MARPOL

ANNEX 2 RESOLUTION MEPC.96(47) Adopted on 8 March 2002

Bunkers Regulatory and Practical Considerations. Athens, Greece, 2 nd February 2018 Capt. Simon Rapley

ANNEX 7. RESOLUTION MEPC.182(59) Adopted on 17 July 2009

Enforcement of low sulpher requirements in the low lands

Sampling Solutions. Fuel and Lube Oil Sampling Equipment. Convenient, Representative, Approved.

TRADING IN ECA AREAS HFO TO LSFO CHANGE OVER

Guidelines for PSCOs on the Inspection Campaign on MARPOL ANNEX VI

Challenges in the implementation of MRV regulation. Yiannis Kokarakis Bureau Veritas

Transport Canada Marine Safety Emission Control Area North America

ANNEX 23. RESOLUTION MEPC.187(59) Adopted on 17 July 2009

High Accuracy Bunker Blending / Bunker Control

White paper. MARPOL Annex VI fuel strategies and their influence on combustion in boilers

RESOLUTION MEPC.181(59) Adopted on 17 July GUIDELINES FOR PORT STATE CONTROL UNDER THE REVISED MARPOL ANNEX VI

High Accuracy Bunker Blending / Bunker Control

SHIPPING and ENVIRONMENT

AMENDMENTS TO MARPOL ANNEX I AND CHANGES TO THE OIL RECORD BOOK PARTS I AND II

ST. VINCENT AND THE GRENADINES

Legal Opinion Review of Vortex Development Group Digital Bunker E-BDN /E-BDR/E-BDC /E-Ship Safety forms for MARPOL and Related Compliance

GUIDELINES FOR PORT STATE CONTROL UNDER MARPOL ANNEX VI

People - Ideas - Solutions

Notice of the Maritime Safety Administration of the People s. Republic of China on Strengthening the Supervision and

People - Ideas - Solutions Marine

AIR POLLUTION AND ENERGY EFFICIENCY. Guidelines for onboard sampling and the verification of the sulphur content of the fuel oil used on board ships

AMENDMENTS TO BUNKER DELIVERY NOTE TO PERMIT THE SUPPLY OF FUEL OIL NOT IN COMPLIANCE WITH REGULATION 14 OF MARPOL ANNEX VI

APPLICATION OF MARPOL 73/78 ANNEX VI TO EXISTING SHIPS

RULE BOILERS, STEAM GENERATORS, AND PROCESS HEATERS (Adopted 5/11/93, Revised 6/13/95, 6/13/00, 9/11/12)

Systems and Arrangement for Meeting Regulations in Emission Control Areas (ECA)

11,000 teu container vessel

CIRCULAR IMO FAQ on the sulphur limits in Emission Control Areas (ECAs)

Fuel handling. in Emission Controlled Areas

Best practice guidance for suppliers for assuring the quality of bunkers delivered to ships

NORTH AMERICAN ECA AND NEW FUEL SULFUR CONTENT REQUIREMENTS

GUIDANCE ON BEST PRACTICE FOR FUEL OIL PURCHASERS/USERS FOR ASSURING THE QUALITY OF FUEL OIL USED ON BOARD SHIPS

Commercial Marine Presentation

GUIDELINES FOR USE OF LOW SULPHUR FUEL OILS IN SHIPS

Sampling & Test Accuracy under the umbrella of emissions legislation

MEPC.1/Circ.736/Rev.1 25 August 2011 GUIDANCE FOR THE RECORDING OF OPERATIONS IN THE OIL RECORD BOOK PART I MACHINERY SPACE OPERATIONS (ALL SHIPS)

Marine Fuels & Environment

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

Technical Publication. Guidelines for the development of ship's Data Collection Plan (SEEMP Part II) /

Seamless Performance Upgrade to IMO OptiLine

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016)

GREENER SHIPPING SUMMIT 2017

Gearless / full scantling cellular container vsl with poop, forecastle and open top cargo hold

International maritime registration procedures and related regulations as they will apply to Refrigerated Vessels

The Nautical Institute

IEA Bioenergy ExCo78 workshop Biofuel supply to Interislander

Recommendation for petroleum fuel treatment systems for marine diesel engines

INFORMATION BULLETIN No. 84

ST. VINCENT AND THE GRENADINES

GUIDANCE ON THE DEVELOPMENT OF A SHIP IMPLEMENTATION PLAN FOR THE CONSISTENT IMPLEMENTATION OF THE 0.50% SULPHUR LIMIT UNDER MARPOL ANNEX VI

Bunker Claims. How an Engine Works. How an Engine Works. Alex Macinnes Sept 2018

Automatic Sampling/Quality Measurement Crude Oil. Crude Oil Quality Association San Antonio, TX March 7, 2013

RESOLUTION A.719(17) adopted on 6 November 1991 PREVENTION OF AIR POLLUTION FROM SHIPS

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

Title: Identification: Revision: GUIDANCE FOR THE RECORDING OF OPERATIONS IN THE OIL RECORD BOOK, PART I

USE OF MDO BY SHIPS THE RATIONAL BEHIND THE PROPOSAL

ff## MINISTRY OF TRANSPORT AND COMMUNICATIONS DEPARTMENT OF MARINE ADMINISTRATION Directive ( )

Technical Information

BALLAST WATER RECORD BOOK

Cargo Handling Sheet. Caradol SP Document date: 19 March 2013 Revision 4

Official Journal of the European Union

ROYAL KLIPPER 580,754 cbft / 6,613 sqm / 8,010 pallets

PROPOSED REGULATIONS AMENDING THE VESSEL POLLUTION AND DANGEROUS CHEMICALS REGULATIONS

PETROLEUM PRODUCTS INSPECTION OPERATIONS MANUAL

MARPOL Annex I and Changes to the Oil Record Book Parts I and II.

RESOLUTION MSC.286(86) (adopted on 5 June 2009) RECOMMENDATIONS FOR MATERIAL SAFETY DATA SHEETS (MSDS) FOR MARPOL ANNEX I OIL CARGO AND OIL FUEL

IFO 380 HEAVY FUEL OIL Vessel using Xbee Natural Fuel Additive

IMO fuel oil consumption data collection system

Form of IOPP Certificate and Supplements * INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)

"Exhaust Gas Scrubbers Abatement System as an Alternative under IMO MARPOL Annex VI''

ECA enforcement & lessons for future action

The North American ECA. Matt Haber US EPA Air Enforcement Division Office of Enforcement and Compliance Assurance

THE IMPACT OF REGULATIONS ON MARINE FUEL QUALITY

MAN Diesel SEA-Mate Onboard Blending and Fluid Analysis Systems

ROYAL CANADIAN AIR CADETS PROFICIENCY LEVEL FOUR INSTRUCTIONAL GUIDE SECTION 1 EO M DESCRIBE FUEL SYSTEMS PREPARATION

Global Sulfur Cap

Module 5 Propulsion and Power Generation of LNG driven Vessels (23 th November to 27 th November University of Piraeus, Greece)

Residual Fuel Market Issues

To: Owners, Technical Managers, Deputy Registrars, Fleet Managers, Surveyors, Recognised Organisations

Oil Metering Valve. Information and rebuild instructions. #905005

DEVELOPMENT OF DRAFT GUIDELINES FOR CONSISTENT IMPLEMENTATION OF REGULATION OF MARPOL ANNEX VI

Regulatory update on implementation of the 0.50% sulphur limit for international shipping

Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping

The North American Emissions Control Area. Matt Haber US EPA Air Enforcement Division Office of Enforcement and Compliance Assurance

HMP. International Association of Independent Tanker Owners. October 2018 INTERTANKO. Leading the way; making a difference

ECA Compliance & PM. Thomas Kirk Director of Environmental Programs. Ottawa, Canada 9 September 2014

RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1997 TO AMEND THE INTERNATIONAL CONVENTION FOR THE

Update on Environment Issues Asian Regional Panel Meeting

Service Bulletin RT Supersedes Bulletin RTA Running-in of Cylinder Liners and Piston Rings

REPORT OF THE MARINE ENVIRONMENT PROTECTION COMMITTEE ON ITS SEVENTIETH SESSION. Corrigendum

Technical Circular. No.: 025 Date: 6 th November 2014

Cargo Handling Sheet. Caradol SA Document date: 11 April 2013 Original document

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Chapter 6 Final Stripping Work

BIMCO & IBIA BUNKERING GUIDE

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Transcription:

IAPP International Air Pollution Prevention INDEX Page 1. General Introduction to MARPOL ANNEX VI 2 2. Bunker Delivery Requirements / MARPOL 3 Specification Form 3. Bunker Sampling Procedure 4 4. Packing Sealing and Dispatch of Bunker Sample 5 5. Procedure for Changing FO to Main Engines 7 6. Diagram of Fuel Oil Lines for Main Engines 8 7. Procedure for Changing FO to Auxiliary Engines 9 8. Diagram of Fuel Oil Lines for Auxiliary Engines 10 9. Procedure for Changing FO to Boiler 11 10. Diagram of Fuel Oil Lines for Boiler 12 11. Details of OZONE Depleting Substances on Board 13 12. Handling of OZONE Depleting Substances 13 Reefership Marine Services, Limited Vessel Management - San Jose, Costa Rica

1. GENERAL From May 19th 2005 the first piece of MARPOL Annex VI came into force. Essentially this first piece of legislation limits the Sulfur level of bunkers used on board ships to 4.5%. As from this same date, Suppliers have a duty to provide the ship with a Bunker Delivery receipt containing the following information: 1. Name & IMO number of Receiving Ship 2. Bunker Port 3. Date of commencement of delivery 4. Name, Address & Telephone number of Supplier 5. Product Name 6. Quantity Metric Tons 7. Density @ 15 C 8. Sulfur content (% m/m) 9. A Declaration signed and certified by the fuel Supplier s representative that the fuel oil supplied is in conformity with the MARPOL Regulations (see Sample on next page) Test methods for Density & Sulfur are to be ISO 3675 & ISO 8754. The Supplier must take a representative sample of the bunkers supplied; the MARPOL recommendation is that this sample be taken by continuous drip at the ship s receiving manifold. This sample needs to be signed and sealed by the Supplier and be marked MARPOL. The seal number on this sample should be written on the Bunker Receipt. The MARPOL sample must be retained on board the ship with the Bunker Delivery receipt for at least one year. This sample must not be used for testing. It should only be released to an officer representing a Port or State authority, if requested. If this sample or any Bunker receipt is handed over to such a person, the Captain must obtain a signature for custody transfer. The new requirements do not change the situation regarding the taking of commercial samples. Ship s staff should continue to take samples at their receiving manifold. One sample is sent for testing, one is issued to the Supplier and the other retained on board for future testing if required. It is also possible that the Supplier may issue another sample to the ship, in the usual manner. This (not the MARPOL sample) may be used for testing in case of any quality dispute. It is not recommend that the Ship s staff take charge of obtaining, labeling, and sealing the MARPOL sample; this is the duty of the Supplier. If the MARPOL sample is taken by Ship's staff and later found to be not representative, the Supplier could blame the Ship and a complicated legal dispute could arise. However, we have included the additional bottle for the MARPOL sample to assist the process if the Supplier does not have a proper bottle. According to MARPOL Annex VI, the Supplier has to provide an extra bottle of the fuel supplied for the C/E to keep onboard the vessel. This is the dedicated MARPOL sample and should be kept onboard under safe custody for a minimum of one year. The volume of the bottle should be at least 400 ml. The bottle label should contain the following information: 2 of 13

1) Location at which and the method by which, the sample was taken 2) Bunker Date 3) Bunker Port 4) Name of Bunker Barge / bunker installation 5) Name and IMO no. of the vessel 6) Supplier Name 7) Name and Signatures of Supplier's representative and Ship's representative 8) Details of Seal Identification 9) Bunker Grade Although it is the Supplier s responsibility to take this sample and provide this extra bottle, vessel is also able to provide an extra bottle, should the Supplier not have a proper bottle. The responsibility for the Supplier's MARPOL sample rests with the Supplier. If ship-staff draw the sample and give it to the Supplier, he could very well say that it is not his sample. Please recognize this important intent of the MARPOL VI regulation. To ensure Compliance with MARPOL specifications, the vessel strictly adheres to the following A defined sample collecting procedure A defined oil sample dispatch procedure. Proper Labeling and dispatch & storing of oil samples 2. Bunker Delivery Note MARPOL SPECIFICATION FORM SHIP NAME DOLE CALIFORNIA BUNKER PORT SUPPLIER NAME SHIP IMO NUMBER 8513467 BUNKER DATE SUPPLIER ADDRESS DATE OF COMMENCEMENT OF DELIVERY BARGE NAME BUNKER INFO FUEL GRADE: QUANTITY: MTons SULPHUR: % m/m DENSITY: kg/m³ @ 15 C This is to certify that the fuel oil supplied conforms to MARPOL regulations. Signature of Chief Engineer Signature of Supplier Representative 3 of 13

3. SAMPLING PROCEDURE Sampling is carried out by the continuous drip method throughout the period of fuel transfer. At the beginning of bunkering; 4 to 5 liters of fuel are flushed into a waste container by opening the needle valve completely. The needle valve on the probe is adjusted to the appropriate setting to ensure collection of a representative sample. The sample is collected in a thoroughly clean, dry disposable plastic cubitainer, which supported by a rigid outer box. A 4-liter container is recommended for this purpose. minimum of 1.5 liters and a maximum of 3 liters of sample are to be collected during bunkering. The neck of the cubitainer is recessed to minimize storage space. By pulling firmly on the cubitainer neck, the threaded portion may be extended to allow connection to the brass cap of the sampler. The valve and the top of the cubitainer are enclosed the security mechanism and locked. See illustration. In case of any substantial change in the rate of fuel flow, the valve may have to be adjusted to compensate for the change in flow rate. When bunkering is completed, the protective casing is unlocked and opened. If the line fuel is being sucked by the shore facility shut the needle valve to prevent cubitainer contents from getting sucked back. The needle valve is opened fully to allow the oil in the sampler to drain into the cubitainer. The cubitainer is removed and capped. It is then shaken vigorously for a minimum of 30 seconds to ensure homogeneity of the sample. The contents of the cubitainer may then be poured into sample bottles. When filling the bottles, the sample should be distributed evenly among the sample bottles in three or four passes, filling each bottle partially with each pass. Each sample bottle is then sealed and labeled for identification. One bottle is sent to the VLC laboratory for testing. One bottle is given to the supplier or his representative. One bottle is to be stored in a safe place in case of any contingency and for future reference. 4 of 13

5 of 13

Labeling of FO Samples VISWA LAB OIL SAMPLE FOR ANALYSIS Vessel Owner Vessel Name IMO No. Port / Location Sampling Date / Grade Supplier Barge / Terminal Sample Pt. / Method Seal # Qty Mtons Remarks Vessel Rep Supplier Rep Name: Name: Sign Sign 6 of 13

Procedure for Changing FO to Main Engines 1. Close the Steam inlet and return valves to the M/E Fuel oil heaters. 2. Let the temperature in the circuit fall down to about 100 degrees Celsius. This will take approximately 45 minutes. 3. Start reducing the ME RPM to 85. 4. When at 85 RPM, change over the Change over (3 Way) inlet valve (between IFO service tank and MDO service tank) to MDO position. 5. Return line to be kept to Mixing tank for proper mixing and subsequent filling with MDO. 6. Check the FO return line to confirm that line contains MDO. For faster change over, the return line to the Mixing tank can be diverted to the HFO Service tank. Though, once MDO is confirmed in the return line, this should then be re-routed to return to the Mixing tank. Other approximate parameters taken into account are: Volume of oil in Pipelines: 160 Liters. Volume of oil in pumps & other accessories: 40 Liters Fuel consumption: 1.3 MT/Hour Time taken for c/o: 90 Minutes) Note: The values quoted in this procedure are when changing over from IFO 500 Refer to Line diagram on next Page. 7 of 13

Sunil Saini Vent v/v I.F.O. Service Pressure Adjusting MAIN ENGINE Hot s Return 3 way Quick Closing pkohli-dffi DAMPER to Service Change Over F.O. Mixing Heater # 1 Viscometer M/E Feed Pumps Flow Meter Heater # 2 Quick Closing Bypas M.D.O. Service F.O. Booster Pumps Drawing by Capt. Pawanexh Kohli M.E. Fuel Oil Line Diagram 8 of 13

Procedure for Changing FO to Auxiliary Engines AA. When required to change over FO to a particular Auxiliary Engine: a. Confirm the particular AE s on which FO requires to be changed over. b. Ensure that the MDO feed pumps are running. c. On this (or each) particular AE, the change over can be affected by using the individual change over valves on its inlet and return lines. Note: In case of blackout/initial start up the Boiler MDO tank can be used to have gravity head pressure in the MDO lines. BB. When required to change over FO to all Auxiliary Engines: a. Close the steam inlet and return valves to the AE Fuel oil heaters. b. Let the temperature in the circuit fall down to about 100 degrees Celsius. (approximately 120 minutes) c. Change over the 3 way inlet valve (between IFO service tank and MDO service tank) to MDO position. d. Run the AE s on load for at least 90 minutes. e. Check the return lines to confirm that the line contains MDO. f. Return line should be set to return FO to the mixing tank. Approximate parameters taken into account are: Volume of oil in pipelines: 400 Liters. Volume of oil in pumps & other accessories: 50 Liters. Time taken for complete c/o: 2 hours. Refer to Line diagram on next Page. 9 of 13

M.D.O. Service I.F.O. Service Feed Pumps Mixing Individual C/O valves AE # 1 AE # 2 Quick Closing Quick Closing Booster Pumps AE # 3 AE # 4 AE # 5 3-Way C/O Boiler MDO Recirculation Pressure Adj. Flow Mete r Heaters 1 & 2 Hot AE # 6 D.O. Feed P/ps For Emergency Use Viscotherm Drawing by Capt. Pawanexh Kohli s A.E. Fuel Oil Line Diagram MDO Return Line 10 of 13

Procedure for Changing FO to Boiler The Boiler can be fired directly on MDO. Ensure the following have been adopted: a. On the change over Block A the position to be set for MDO intake. b. The MDO feed pump to be kept running. Refer to Enlarged Line diagram on next Page 11 of 13

I.F.O. Service M.D.O. Service Pressure Adj. Boiler D.O. Change Over Block A D.O. Pump F.O. Pumps Pump for Pilot Burner BOILER H E A T E R Change Over Block B to Mixing from Mixing Main Burner pkohli-dffi Pressure Adj. Boiler Fuel Oil Line Diagram 12 of 13

Details of OZONE Depleting Substances on Board UTILITY Refrigerants are the only substances specified as Ozone depleting on board the vessel. The following list details the services using ozone depleting substances (refrigerants). # Service Location Model Refrigerant Used Quantity of Refrigerant Used 1. Accommodation AC Plant 1 E/R 1 st Flat Stbd For d CVC 077 R22 (HCFC 22) 70.0 Kg 2. Accommodation AC Plant 2 E/R 1 st Flat Stbd For d CVC 077 R22 (HCFC 22) 70.0 Kg 3. ECR AC Plant 1 Main Deck Port aft of ECR 4 CC 68 R22 (HCFC 22) - 4. ECR AC Plant 2 Main Deck Port aft of ECR 4 CC 68 R22 (HCFC 22) - 5. Provision Room Plant 1 E/R 1 st Flat Stbd For d 41VS/M R22 (HCFC 22) 19.1 Kg 6. Provision Room Plant 2 E/R 1 st Flat Stbd For d 41VS/M R22 (HCFC 22) 19.1 Kg TOTAL Refrigerant in Use on Board: 178.2 Kg REFRIGERANT STORE (Recharging bottles) o Refrigerant Stored at: Freon Storage Room o Located At: Main Deck Port aft of Central Store o Quantity Stored: 5 bottles x 57 kg each REFRIGERANT RECOVERY EQUIPMENT Equipment to recover refrigerant has been installed on board. Details are as follows: o Manufacturer: Unitor o Capacity: 55.8 Ltrs. Handling Of Ozone Depleting Substances o o o o o No Ozone depleting substance is allowed to escape to atmosphere. Refrigerant Recovery Equipment is used to recover refrigerant from services as and when required. If refrigerant is not contaminated, it is reused to recharge. When refrigerant is contaminated, it is landed for authorized disposal. Operating Manual of the recovery equipment is attached. 13 of 13