ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range of materials from polyamide, nickel-plated brass and stainless steel to withstand any environment. ppleton's TX cable glands are available with metric or NPT threads. Cable glands are certified for increased safety, flameproof, restricted breathing and dust applications.
escription Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I pplication Entry Thread Seal 2, E1X/E2X, E1W/E2W and T3 Series 402-406 Nickel Plated Brass Cable Glands for Unarmored and rmored Cables with Elastomer Seal Increased Safety and lameproof 2, E1X/E2X, E1W/E2W and T3 Series 2 Series E1X/E2X Series E1W/E2W Series T3 Series PX and PX2K Series 407-409 Nickel Plated Brass Cable Glands for Unarmored and rmored Cables with Compound Barrier Seal Increased Safety and lameproof PX and PX2K Series PX Series PX2K Series 757, BVE and 737 Series 410-414 Blanking Plugs, daptors and Reducers Increased Safety and lameproof 757, BVE and 737 Series ccessories for Cable Entries 415-417 Nickel Plated Brass Locknuts ccessories 757 Series BVE Series 737 Series Brass Earth Tag Entry Thread Seals Locknuts Brass Earth Tag Entry Thread Seal 316L Stainless Steel Serrated Washers PVC Shrouds Clamp for Lead Sheath rmored Cable Glands 316L Serrated Washers PVC Shrouds Lead Clamp B Series 418-425 rain and Breather Valves 419 B Series ire Retardant Seals and IIC Elbows 420-421 IIC lexible Couplings 422-423 IIB Unions lameproof 424-425 Bleed valve ire Retardant Seal IIC Elbow IIC lexible Coupling IIB Union TX Product Catalog 398
Introduction to Cable Glands Ex d, Ex e & Ex n Cable Gland Selection Chart Unarmored rmored Tape Wire Braid (ST) (SW) (SWB) Unarmored Cables Cable efinition bbreviation elastomer seal ring compound seal Unarmored 2 PX rmored Cables Cable efinition bbreviation elastomer seal ring compound seal Steel Tape rmor ST E1X T3 PX2K Steel Wire Braid SWB E1X T3 PX2K Single Wire rmor SW E1W T3 PX2K rmored Cables with Lead Sheath Cable efinition bbreviation elastomer seal ring compound seal Steel Tape rmor ST, LC E2X T3PB PX2KPB Steel Wire Braid SWB, LC E2X T3PB PX2KPB Single Wire rmor SW, LC E2W T3PB PX2KPB 399 TX Product Catalog
2, E1X/E2X, E1W/E2W and T3 Series: Nickel Plated Brass Cable Glands for Unarmored and rmored Cables with Elastomer Seal Increased Safety and lameproof 2 Series E1X & E2X Series E1W & E2W Series T3 Series Compliance ata: TEX IECEx: TEX IECEx CE Ex d IIC or Ex e II Ex t 21 IP 66 / 68 (10m) or Operating Temperature: -60 C to +130 C TX Product Catalog 402
2 Series: Nickel Plated Brass Cable Glands for Unarmored Cables with Elastomer Seal Increased Safety and lameproof TEX / IECEx IP66/68 2 Series pplications: Cable glands for unarmored cable certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - pages G43 - G46.) - Ex e increased safety - Ex nr restricted breathing - dust environment Hazardous areas (gas and dust) Onshore and offshore eatures: Elastomer displacement seal for unarmored cable provides a combined flameproof and weatherproof seal on the outer sheath of the cable. Seal: LS (Low Smoke ume) thermoplastic elastomer. 316L stainless steel version: replace last digit 5 with 4. Example: 25 2 075 5 25 2 075 4. Example: 25 2 075 5 25 2 075. Cable Cable Capacity im. Length Gland (mm) (mm) (mm) Size Min. Max. Corner lat Metric* NPT NPT (other versions) (kg) 2016 3.2 8.7 26.6 24.0 21.0 M20 2016 2 5 1/2" 2016 2 050 5 3/4" 2016 2 075 5 0.07 20S 6.1 11.7 26.6 24.0 21.0 M20 20S 2 5 1/2" 20S 2 050 5 3/4" 20S 2 075 5 0.06 20 6.5 14.0 31.0 27.0 24.0 M20 20 2 5 1/2" 20 2 050 5 3/4" 20 2 075 5 0.06 25 11.1 20.0 39.0 36.0 26.0 M25 25 2 5 3/4" 25 2 075 5 1" 25 2 100 5 0.12 32 17.0 26.3 45.0 41.0 27.0 M32 32 2 5 1" 32 2 100 5 1-1/4" 32 2 125 5 0.13 40 23.5 32.2 53.5 50.0 28.0 M40 40 2 5 1-1/4" 40 2 125 5 1-1/2" 40 2 150 5 0.18 50S 31.0 38.2 61.0 55.0 29.0 M50 50S 2 5 1-1/2" 50S 2 150 5 2" 50S 2 200 5 0.24 50 35.6 44.1 66.0 60.0 30.0 M50 50 2 5 2" 50 2 200 5 2-1/2" 50 2 250 5 0.24 63S 41.5 50.0 77.5 70.0 30.0 M63 63S 2 5 2" 63S 2 200 5 2-1/2" 63S 2 250 5 0.37 63 47.2 56.0 84.0 75.0 30.0 M63 63 2 5 2-1/2" 63 2 250 5 3" 63 2 300 5 0.36 75S 54.0 62.0 87.0 79.0 32.0 M75 75S 2 5 2-1/2" 75S 2 250 5 3" 75S 2 300 5 0.42 75 61.1 68.0 94.0 84.0 32.0 M75 75 2 5 3" 75 2 300 5 3-1/2" 75 2 350 5 0.39 90 66.6 80.0 120.0 108.0 44.0 M90 90 2 5 3" 90 2 300 5 3-1/2" 90 2X 350 5 1.48 100 76.0 91.0 138.0 122.0 48.0 M100 100 2 5 4" 100 2 400 5 - - 1.62 ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud see accessories section) Hazardous rea Gas ust 2 Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, mbient Temperature CE eclaration of Conformity TEX Certificate N.. -60 C to +130 C C07001 SIR 06 TEX 1097X IECEx Certificate IECEx SIR 06.0043X Ex t 21 CS, GOST, Lloyds, NV, BS IP66 / IP68 (10m) Product Standards BS 6121, N E 03 601 (conical thread); 403 TX Product Catalog
E1X / E2X Series: Nickel Plated Brass Cable Glands for rmored Cables with Elastomer Seal Increased Safety and lameproof TEX / IECEx IP66 E1X & E2X Series pplications: Cable gland for armored cables (braid, tape, tape with lead sheath) certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - Pages G43 - G46.) - Ex e increased safety - Ex nr restricted breathing - dust environment Hazardous areas (gas and dust) Onshore and offshore eatures: elastomer seal for use in hazardous areas with braided and tape armor cable. The cable gland allows mechanical cable retention and earth continuity via cable armor termination. detachable armor cone and nyway clamping ring arrangement facilitates remote make off and enables cable to be disconnected from the equipment. Inspection of the armor can be carried out while still maintaining the explosion -proof protection mode of the enclosure. Seal: LS (Low Smoke ume) thermoplastic elastomer. - Inner displacement seal and LRS (Load Retention seal) outer seal. Lead sheath version E2X series: Replace digit 1 with 2. Example: 32 E1X 5 32 E2X 5. Example: 25 E1X 075 5 25 E1X 075. Cable Gland Cable Capacity Inner Outer B im. (mm) Length Size Min. Max. Min. Max. Corner lat (mm) Metric* NPT NPT (other versions) (kg) 2016 3.1 8.7 6.1 11.5 26.6 24.0 58.5 M20 2016 E1X 5 1/2" 2016 E1X 050 5 3/4" 2016 E1X 075 5 0.16 20S 6.1 11.7 9.5 15.9 26.6 24.0 58.5 M20 20S E1X 5 1/2" 20S E1X 050 5 3/4" 20S E1X 075 5 0.16 20 6.5 14.0 12.5 20.9 33.3 30.5 60.5 M20 20 E1X 5 1/2" 20 E1X 050 5 3/4" 20 E1X 075 5 0.21 25S 11.1 20.0 14.0 22.0 40.5 37.5 67.5 M25 25S E1X 5 3/4" 25S E1X 075 5 1" 25S E1X 100 5 0.32 25 11.1 20.0 18.2 26.2 40.5 37.5 67.5 M25 25 E1X 5 3/4" 25 E1X 075 5 1" 25 E1X 100 5 0.32 32 17.0 26.3 23.7 33.9 51.0 46.0 69.5 M32 32 E1X 5 1" 32 E1X 100 5 1-1/4" 32 E1X 125 5 0.45 40 22.0 32.2 27.9 40.4 61.0 55.0 78.0 M40 40 E1X 5 1-1/4" 40 E1X 125 5 1-1/2" 40 E1X 150 5 0.68 50S 29.5 38.2 35.2 46.7 66.5 60.0 75.5 M50 50S E1X 5 1-1/2" 50S E1X 150 5 2" 50S E1X 200 5 0.73 50 35.6 44.1 40.4 53.1 78.6 70.0 80.5 M50 50 E1X 5 2" 50 E1X 200 5 2-1/2" 50 E1X 250 5 0.75 63S 40.1 50.0 45.6 59.4 83.2 75.0 91.5 M63 63S E1X 5 2" 63S E1X 200 5 2-1/2" 63S E1X 250 5 1.34 63 47.2 56.0 54.6 65.9 89.0 80.0 92.0 M63 63 E1X 5 2-1/2" 63 E1X 250 5 3" 63 E1X 300 5 1.44 75S 52.8 62.0 59.0 72.1 101.6 89.0 99.0 M75 75S E1X 5 2-1/2" 75S E1X 250 5 3" 75S E1X 300 5 2.07 75 59.1 68.0 66.7 78.5 111.1 99.0 102.0 M75 75 E1X 5 3" 75 E1X 300 5 3-1/2" 75 E1X 350 5 2.62 90 66.6 80.0 76.2 90.4 128.6 114.0 120.0 M90 90 E1X 5 3" 90 E1X 300 5 3-1/2" 90 E1X 350 5 4.17 100 76.0 91.0 86.1 101.5 138.0 123.0 148.0 M100 100 E1X 5 4" 100 E1X 400 5 - - 4.52 ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud see accessories section) Hazardous rea Gas ust E1X/Z - E2X/Z Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, Ex t 21 N.. mbient Temperature -60 C to +130 C CE eclaration of Conformity C07001 TEX Certificate SIR 06 TEX 1097X IECEx Certificate IECEx SIR 06.0043X GOST IP66 Product Standards BS 6121, N E 03 601 (conical thread); Other Standards GOST B E2X Series (see options) Ring for lead sheath Lead sheath TX Product Catalog 404
E1W / E2W: Nickel Plated Brass Cable Glands for rmored Cables with Elastomer Seal Increased Safety and lameproof TEX / IECEx IP66 E1W & E2W Series pplications: Cable gland for Single Wire rmored cables (SW with wire and lead sheath) certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - Pages G43 - G46). - Ex e increased safety. - Ex nr restricted breathing. - dust environment. Hazardous areas (gas and dust). Onshore and offshore. eatures: elastomer seal for use in hazardous areas with Single Wire rmor (SW) cable. The cable gland allows mechanical cable retention and earth continuity via cable armor termination. detachable armor cone and nyway clamping ring arrangement facilitates remote make off and enables cable to be disconnected from the equipment. Inspection of the armor can be carried out while still maintaining the protection mode of the enclosure. Seal: LS (Low Smoke ume) thermoplastic elastomer. - Inner displacement seal and LRS (Load Retention seal) outer seal. Lead sheath version E2W series: Replace digit 1 with 2. Example: 32 E1W 5 32 E2W 5. Example: 25 E1W 075 5 25 E1W 075. Cable Cable Capacity im. Length Gland Inner Outer B (mm) Size Min. Max. Min. Max. Corner lat (mm) Metric* NPT NPT (other versions) (kg) 2016 3.1 8.7 6.1 11.5 26.6 24.0 58.5 M20 2016 E1W 5 1/2" 2016 E1W 050 5 3/4" 2016 E1W 075 5 0.16 20S 6.1 11.7 9.5 15.9 26.6 24.0 58.5 M20 20S E1W 5 1/2" 20S E1W 050 5 3/4" 20S E1W 075 5 0.16 20 6.5 14.0 12.5 20.9 33.3 30.5 60.5 M20 20 E1W 5 1/2" 20 E1W 050 5 3/4" 20 E1W 075 5 0.20 25S 11.1 20.0 14.0 22.0 40.5 37.5 67.5 M25 25S E1W 5 3/4" 25S E1W 075 5 1" 25S E1W 100 5 0.32 25 11.1 20.0 18.2 26.2 40.5 37.5 67.5 M25 25 E1W 5 3/4" 25 E1W 075 5 1" 25 E1W 100 5 0.32 32 17.0 26.3 23.7 33.9 51.0 46.0 69.5 M32 32 E1W 5 1" 32 E1W 100 5 1-1/4" 32 E1W 125 5 0.45 40 22.0 32.2 27.9 40.4 61.0 55.0 78.0 M40 40 E1W 5 1-1/4" 40 E1W 125 5 1-1/2" 40 E1W 150 5 0.67 50S 29.5 38.2 35.2 46.7 66.5 60.0 75.5 M50 50S E1W 5 1-1/2" 50S E1W 150 5 2" 50S E1W 200 5 0.73 50 35.6 44.1 40.4 53.1 78.6 70.0 80.5 M50 50 E1W 5 2" 50 E1W 200 5 2-1/2" 50 E1W 250 5 0.75 63S 40.1 50.0 45.6 59.4 83.2 75.0 91.5 M63 63S E1W 5 2" 63S E1W 200 5 2-1/2" 63S E1W 250 5 1.34 63 47.2 56.0 54.6 65.9 89.0 80.0 92.0 M63 63 E1W 5 2-1/2" 63 E1W 250 5 3" 63 E1W 300 5 1.44 75S 52.8 62.0 59.0 72.1 101.6 89.0 99.0 M75 75S E1W 5 2-1/2" 75S E1W 250 5 3" 75S E1W 300 5 2.07 75 59.1 68.0 66.7 78.5 111.1 99.0 102.0 M75 75 E1W 5 3" 75 E1W 300 5 3-1/2" 75 E1W 350 5 2.62 90 66.6 80.0 76.2 90.4 128.6 114.0 120.0 M90 90 E1W 5 3" 90 E1W 300 5 3-1/2" 90 E1W 350 5 4.17 100 76.0 91.0 86.1 101.5 138.0 123.0 148.0 M100 100 E1W 5 4" 100 E1W 400 5 - - 4.52 ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud - see accessories section) Hazardous rea Gas ust E1W/Z - E2W/Z Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, mbient Temperature CE eclaration of Conformity TEX Certificate N.. -60 C to +130 C C07001 SIR 06 TEX 1097X IECEx Certificate IECEx SIR 06.0043X GOST IP66 Ex t 21 Product Standards BS 6121, N E 03 601 (conical thread); Other Standards B E2W Series (see options) GOST Ring for lead sheath Lead sheath 405 TX Product Catalog
T3 Series: Nickel Plated Brass Cable Glands for rmored Cables with Elastomer Seal Increased Safety and lameproof TEX / IECEx IP66 / 68 (10 m) T3 Series pplications: Cable gland for all types of armored cable certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - Pages G43 - G46.). - Ex e increased safety. - Ex nr restricted breathing. - dust environment. Hazardous areas (gas and dust). Onshore and offshore. eatures: elastomer seal for use in hazardous areas with all types of armored cable. This product utilizes a unique Compensating isplacement Seal (CS) system which provides full compatibility with restricted breathing equipment. The CS system is designed to alleviate any pressure on soft bedded cables. The cable gland allows mechanical cable retention and earth continuity via armor termination. reversible armor cone and nyway universal clamping ring arrangement allows the cable to be easily disconnected from equipment. The cable gland is IP66 / 68 and complies with deluge protection tests. Inspection of the armor can be carried out while still maintaining the protection mode of the enclosure. Seal: LS (Low Smoke ume) thermoplastic elastomer. - Inner CS system and LRS (Load Retention Seal) outer seal. 316L stainless steel version: replace last digit 5 with 4. Example: 25 T3 075 5 25 T3 075 4. Lead sheath version: replace T3 with T3PB. Example: 25 T3 075 5 25 T3PB 075 5. Example: 25 T3 075 5 25 T3 075. Cable Gland Cable Capacity Inner Outer B im. (mm) Length Size Min. Max. Min. Max. Corner lat (mm) Metric* NPT NPT (other versions) (kg) 2016 3.1 8.7 6.1 11.5 26.6 24.0 65.0 M20 2016 T3 5 1/2" 2016 T3 050 5 3/4" 2016 T3 075 5 0.17 20S 6.1 11.7 9.5 15.9 26.6 24.0 64.0 M20 20S T3 5 1/2" 20S T3 050 5 3/4" 20S T3 075 5 0.17 20 6.5 14.0 12.5 20.9 33.3 30.5 63.0 M20 20 T3 5 1/2" 20 T3 050 5 3/4" 20 T3 075 5 0.26 25S 11.1 20.0 14.0 22.0 40.5 37.5 74.0 M25 25S T3 5 3/4" 25S T3 075 5 1" 25S T3 100 5 0.38 25 11.1 20.0 18.2 26.2 40.5 37.5 76.0 M25 25 T3 5 3/4" 25 T3 075 5 1" 25 T3 100 5 0.38 32 17.0 26.3 23.7 33.9 51.0 46.0 80.0 M32 32 T3 5 1" 32 T3 100 5 1-1/4" 32 T3 125 5 0.56 40 22.0 32.2 27.9 40.4 61.0 55.0 75.0 M40 40 T3 5 1-1/4" 40 T3 125 5 1-1/2" 40 T3 150 5 0.85 50S 29.5 38.2 35.2 46.7 66.5 60.0 93.0 M50 50S T3 5 1-1/2" 50S T3 150 5 2" 50S T3 200 5 1.05 50 35.6 44.1 40.4 53.1 78.6 70.0 100.0 M50 50 T3 5 2" 50 T3 200 5 2-1/2" 50 T3 250 5 1.52 63S 40.1 50.0 45.6 59.4 83.2 75.0 95.0 M63 63S T3 5 2" 63S T3 200 5 2-1/2" 63S T3 250 5 1.75 63 47.2 56.0 54.6 65.9 89.0 80.0 98.0 M63 63 T3 5 2-1/2" 63 T3 250 5 3" 63 T3 300 5 1.68 75S 52.8 62.0 59.0 72.1 101.6 89.0 105.0 M75 75S T3 5 2-1/2" 75S T3 250 5 3" 75S T3 300 5 2.34 75 59.1 68.0 66.7 78.5 111.1 99.0 112.0 M75 75 T3 5 3" 75 T3 300 5 3-1/2" 75 T3 350 5 3.20 90 66.6 80.0 76.2 90.4 128.6 114.0 132.0 M90 90 T3 5 3" 90 T3 300 5 3-1/2" 90 T3 350 5 5.10 100 76.0 91.0 86.1 101.5 138.0 123.0 160.0 M100 100 T3 5 4" 100 T3 400 5 - - 6.30 ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud - see accessories section) Hazardous rea Gas ust T3CS Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, Ex t 21 N.. mbient Temperature -60 C to +130 C CE eclaration of Conformity C07001 TEX Certificate SIR 06 TEX 1283X IECEx Certificate IECEx SIR 07.005X CS, UL, GOST, Lloyds, NV, BS IP66/68 (10m) Product Standards BS 6121, N E 03 601 (conical thread); Other Standards GOST, UL, CS T3 Series B TX Product Catalog 406
PX and PX2K Series: Nickel Plated Brass Cable Glands for Unarmored and rmored Cables with Compound Barrier Seal Increased Safety and lameproof PX Series PX2K Series Compliance ata: TEX IECEx: TEX IECEx CE Ex d IIC or Ex e II Ex t 21 IP 66/68 (10m) or Operating Temperature: -60 C to +100 C 407 TX Product Catalog
PX Series: Nickel Plated Brass Cable Glands for Unarmored Cables with Compound Barrier Seal Increased Safety and lameproof TEX / IECEx IP66/68 (10 m) PX (PXSS2K) Series pplications: Cable gland for unarmored cables certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - Pages G43 - G46.). - Ex e increased safety. - Ex nr restricted breathing. - dust environment. Hazardous areas (gas and dust). Onshore and offshore. eatures: compound barrier seal for use in hazardous areas with all types of unarmored cables. The cable gland provides mechanical cable retention. combined detachable spacer and compound tube allows the cable to be easily disconnected from the equipment. The cable gland is IP66 / 68 and complies with deluge protection tests. Epoxy resin supplied with the cable gland. Epoxy resin barrier compound. Seal: LS (Low Smoke ume) thermoplastic elastomer displacement outer seal. 316L stainless steel version: replace last digit 5 with 4. Example: 25 PX 075 5 25 PX 075 4. Example: 25 PX 075 5 25 PX 075. Cable Gland Resin Cable (mm) Outer B im. (mm) Length Size Ø (mm) (1) Min. Max. Corner lat (mm) Metric* NPT NPT (other versions) (kg) 20S/16 12.6 15 3.0 8.7 26.6 24.0 58.5 M20 2016 PX 5 1/2" 2016 PX 050 5 3/4" 2016 PX 075 5 0.15 20S 12.6 15 6.1 11.7 26.6 24.0 58.5 M20 20S PX 5 1/2" 20S PX 050 5 3/4" 20S PX 075 5 0.15 20 12.6 15 6.5 14.0 33.3 30.5 60.5 M20 20 PX 5 1/2" 20 PX 050 5 3/4" 20 PX 075 5 0.15 25 17.5 29 11.1 20.0 40.5 37.5 67.5 M25 25 PX 5 3/4" 25 PX 075 5 1" 25 PX 100 5 0.27 32 23.6 51 17.0 26.3 51.0 46.0 69.5 M32 32 PX 5 1" 32 PX 100 5 1-1/4" 32 PX 125 5 0.29 40 30.0 80 22.0 32.1 61.0 55.0 78.0 M40 40 PX 5 1-1/4" 40 PX 125 5 1-1/2" 40 PX 150 5 0.40 50S 36.6 122 29.5 38.2 66.5 60.0 75.5 M50 50S PX 5 1-1/2" 50S PX 150 5 2" 50S PX 200 5 0.49 50 41.0 149 35.6 44.1 78.6 70.0 80.5 M50 50 PX 5 2" 50 PX 200 5 2-1/2" 50 PX 250 5 0.51 63S 47.9 205 40.1 50.1 83.2 75.0 91.5 M63 63S PX 5 2" 63S PX 200 5 2-1/2" 63S PX 250 5 0.60 63 53.7 259 47.2 56.0 89.0 80.0 92.0 M63 63 PX 5 2-1/2" 63 PX 250 5 3" 63 PX 300 5 0.62 75S 59.8 230 52.8 62.0 101.6 89.0 99.0 M75 75S PX 5 2-1/2" 75S PX 250 5 3" 75S PX 300 5 1.05 75 64.3 364 59.1 68.0 111.1 99.0 102.0 M75 75 PX 5 3" 75 PX 300 5 3-1/2" 75 PX 350 5 1.15 (1) Number of cores (Max.) ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud - see accessories section) Hazardous rea Gas ust PXSS2K Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, Ex t 21 N.. mbient Temperature -60 C to +100 C CE eclaration of Conformity C07001 TEX Certificate SIR 06 TEX 1097X IECEx Certificate IECEx SIR 06.0044X CS, UL, GOST, Lloyds, NV, BS IP66 / IP68 (10 m) Product Standards BS 6121, N E 03 601 (conical thread); Other Standards GOST, UL, CS B TX Product Catalog 408
PX2K Series: Nickel Plated Brass Cable Glands for ll Types of rmored Cables (Braids, Tape and Wire with Lead Sheath Version) with Compound Barrier Seal Increased Safety and lameproof TEX / IECEx IP66/68 (10 m) PX2K Series pplications: Cable gland for all types of armored cables (braid, tape, wire and lead sheath version) certified for enclosures with the following protection modes: - Ex d flameproof IIB or IIC (as per 10.4.2 of IEC 60079-14) (Refer to Guide for Use of Electrical Products in Hazardous Locations - Pages G43 - G46.). - Ex e increased safety. - Ex nr restricted breathing. - dust environment. Hazardous areas (gas and dust). Onshore and offshore. eatures: compound barrier seal for use in hazardous areas with all types of armored cables (braid, tape and wire). The cable gland provides mechanical cable retention and earth continuity via cable armor termination. combined detachable armor cone and compound tube, together with nyway universal clamping ring arrangement allows the cable to be easily disconnected from the equipment. The cable gland is IP66 / 68 and complies with deluge protection tests. The cable gland is supplied with epoxy resin and two detachable armor cones. Epoxy resin barrier compound. Seal: LS (Low Smoke ume) thermoplastic elastomer displacement outer seal. 316L stainless steel version: replace last digit 5 with 4. Example: 25 PX2K 075 5 25 PX2K 075 4. Lead sheath version: Replace PX2K with PX2KPB. Example: 25 PX2K 075 5 25 PX2KPB 075 5. Example: 25 PX2K 075 5 25 PX2K 075. Cable Resin Cable (mm) im. Length Gland Outer B (mm) Size Ø (mm) (1) Min. Max. Corner lat (mm) Metric* NPT NPT (other versions) (kg) 2016 12.6 15 6.1 11.5 26.6 24.0 58.5 M20 2016 PX2K 5 1/2" 2016 PX2K 050 5 3/4" 2016 PX2K 075 5 0.20 20S 12.6 15 9.5 15.9 26.6 24.0 58.5 M20 20S PX2K 5 1/2" 20S PX2K 050 5 3/4" 20S PX2K 075 5 0.20 20 12.6 15 12.5 20.9 33.3 30.5 60.5 M20 20 PX2K 5 1/2" 20 PX2K 050 5 3/4" 20 PX2K 075 5 0.23 25S 17.5 29 14.0 22.0 40.5 37.5 67.5 M25 25S PX2K 5 3/4" 25S PX2K 075 5 1" 25S PX2K 100 5 0.33 25 17.5 29 18.2 26.2 40.5 37.5 67.5 M25 25 PX2K 5 3/4" 25 PX2K 075 5 1" 25 PX2K 100 5 0.33 32 23.6 51 23.7 33.9 51.0 46.0 69.5 M32 32 PX2K 5 1" 32 PX2K 100 5 1-1/4" 32 PX2K 125 5 0.51 40 30.0 80 27.9 40.4 61.0 55.0 78.0 M40 40 PX2K 5 1-1/4" 40 PX2K 125 5 1-1/2" 40 PX2K 150 5 0.72 50S 36.6 122 35.2 46.7 66.5 60.0 75.5 M50 50S PX2K 5 1-1/2" 50S PX2K 150 5 2" 50S PX2K 200 5 0.82 50 41.0 149 40.4 53.1 78.6 70.0 80.5 M50 50 PX2K 5 2" 50 PX2K 200 5 2-1/2" 50 PX2K 250 5 0.86 63S 47.9 205 45.6 59.4 83.2 75.0 91.5 M63 63S PX2K 5 2" 63S PX2K 200 5 2-1/2" 63S PX2K 250 5 1.45 63 53.7 259 54.6 65.9 89.0 80.0 92.0 M63 63 PX2K 5 2-1/2" 63 PX2K 250 5 3" 63 PX2K 300 5 1.60 75S 59.8 320 59.0 72.1 101.6 89.0 99.0 M75 75S PX2K 5 2-1/2" 75S PX2K 250 5 3" 75S PX2K 300 5 2.30 75 64.3 364 66.7 78.5 111.1 99.0 102.0 M75 75 PX2K 5 3" 75 PX2K 300 5 3-1/2" 75 PX2K 350 5 3.05 90 75.3 500 76.2 90.4 128.6 114.0 120.0 M90 90 PX2K 5 3" 90 PX2K 300 5 3-1/2" 90 PX2K 350 5 5.00 (1) Number of cores (Max.) ccessories: (Locknut, entry thread seal, serrated washer, earth tag and shroud - see accessories section) Hazardous rea Gas ust PX2K Conforming to 94/9/CE TEX Symbol of Protection TEX Ex d IIC, Ex e II, mbient Temperature CE eclaration of Conformity TEX Certificate N.. -60 C to +100 C C07001 SIR 06 TEX 1097X IECEx Certificate IECEx SIR 06.0044X GOST, Lloyds, NV, BS IP66 / IP68 (10 m) Ex t 21 Product Standards BS 6121, N E 03 601 (conical thread); Other Standards 409 TX Product Catalog B GOST