Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

Similar documents
Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

UltraSIL polymer-housed VariSTAR station-class surge arresters

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

GENERAL. CONSTRUCTION External

GE TRANQUELLTM Surge Arresters

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

UltraSIL polymer-housed VariSTAR surge arresters 5 ka and 10 ka Class 1 IEC for MV systems to 36 kv

A 1.2 kv class externally removable secondary bushing

100 A externally operated one-, twoand three-phase tap-changer switch

ELF -LR current-limiting fuse

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

Edison modular fuse, vault application products

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Direct-connected capacitor fuse

Surge Arresters. UltraSIL Housed VariSTAR Surge Arresters 5 ka and 10 ka Class 1 IEC for MV Systems to 36 kv FEATURES.

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

GE TRANQUELL Surge Arresters

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

High-voltage primary bushings installation instructions

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

X-Limiter full-range current-limiting fuse

Energy Division. PCA Single Column Polymeric Surge Arrester

K-Limiter high ampere Companion II fuse

Zinc Oxide Surge Arrester EXLIM R

600 A 28 kv class Cleer loadbreak connector system

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

600 A 35 kv class BT-TAP deadbreak connector

OHIO BRASS AIKEN, SC, USA

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

Directly Molded Polymer Surge Arresters

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

25 kv class fused loadbreak elbow connector

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

Eaton s Cooper Power Systems

600 A 15 kv class Cleer loadbreak connector system

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

COOPER POWER CA280012EN

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

600 A 35 kv class separable splices

600 A 25 kv class BT-TAP deadbreak connector

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Surge arrester POLIM-H..SD

Zinc Oxide Surge Arrester PEXLIM Q

Effective November 2016 Supersedes September 1998 (S )

600 A 15 kv class T-OP II deadbreak connector

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Zinc-Oxide Surge Arrester TEXLIM Q-C

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

CMU medium voltage power fuses

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Effective March 2015 Supersedes S August 2012

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

3EK7 Medium Voltage Silicone Insulated Surge Arresters

600 A 15 and 25 kv class Cleer grounding elbow

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

3EK7 Distribution Class Surge Arresters. Answers for energy.

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

Station Class Polymeric Surge Arresters

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

Surge arrester POLIM-H.. ND

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

1500 kva Padmount Transformer delta Primary Voltage 208Y/120 Secondary Voltage

Overview about research project Energy handling capability

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Type NR oil switch installation and operation instructions

M-Force three-phase switch

Effective May 2017 Supersedes January 2003 (S )

M-Force three-phase switch

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

Single-Phase Step Voltage Regulators

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014

Transcription:

Surge Arresters Technical Data TD235027EN Supersedes November 2003 (TD-230) COOPER POWER SERIES Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks Ø40.74 ±0.41 0.051 ±0.013 Ø40.64 ±0.381 Glass insulating Ø41.35 +0.661-0.509 Ø40.64 ±0.381 0.051 ±0.013 0.356 +0.140-0.064 34.63 ±0.3 34.63 ±0.3 Glass insulating (Translucent) Mov disk AV5HG Metalized electrode (To edge of disk) Epoxy insulating (Solid grey) Surface area = 12.97 cm 2 volume = 44.75 cm 3 Mov disk AV5HE Metalized electrode (To edge of disk)

Technical Data TD235027EN Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Application The VariSTAR MOV (Metal Oxide Varistor) disks described in this Technical Data sheet are for use as active elements in IEC 10 ka Class 1 and ANSI Heavy-Duty Distribution Class Surge Arresters, when applied in an appropriately designed arrester. Polymer housed arrester designse: Use the glass ed AV5HG series VariSTAR disks, when applying disks to a polymer housed arrester, where the dielectric strength of the material in direct contact with the disks exceeds the dielectric strength of air. Porcelain housed arrester designse: Option 1. Use the glass ed AV5HG series VariSTAR disk together with an Epoxy Film Tape, as described in technical data sheet TD-241, when applying disks in a porcelain housed arrester, where the material in direct contact with the VariSTAR disks is equal to the dielectric strength of air. Option 2. Use the epoxy ed AV5HE series VariSTAR disks, when applying disks in a porcelain housed arrester, where the dielectric strength of the material in direct contact with the disks is equal to the dielectric strength of air. Electrical properties for AV5HG and AV5HE series VariSTAR disks are otherwise identical. Catalog number reference: AV5 = Disk Size H = Heavy-Duty, 10 ka G/E = Glass or Epoxy Collar PA/PB = Rating Designation Ø40.74 ±0.41 0.051 ±0.013 Ø40.64 ±0.381 Glass insulating Ø41.35 +0.661-0.509 Ø40.64 ±0.381 0.051 ±0.013 0.356 +0.140-0.064 34.63 ±0.3 34.63 ±0.3 Glass Mov disk insulating AV5HG (Translucent) Metalized electrode (To edge of disk) Epoxy insulating (Solid grey) Surface area = 12.97 cm 2 volume = 44.75 cm 3 Mov disk AV5HE Metalized electrode (To edge of disk) Figure 1. Dimensions AV5HG VariSTAR disk and AV5HE VariSTAR disk in mm Table 1. Suggested usage & class ratings Catalog number AV5HEPA AV5HEPB Suggested U r (Rating) Suggested U c (MCOV) IEC LD current withstand ANSI LCLD class IEC high current ANSI HCSD 4.5 kv 3.94 kv Class 1 250 A 2000 μs 100 ka 5 ma 5 kv 4.26 kv Class 1 250 A 2000 μs 100 ka 5 ma Table 2. Maximum residual voltages Catalog number AV5HEPA AV5HEPB NNote: Rating MCOV (kv rms) 0.5 μsec (ANSI) kv @ 10 ka 1.0 μsec (IEC) kv @ 10 ka kv @ 125 A switching surge kv @ 500 A switching surge 8/20 μs Wave forms 1.5 ka 3 ka 5 ka 10 ka I ref 20 ka 4.5 3.94 16.8 16.5 10.8 11.5 12.4 13.2 13.8 15.1 16.7 19.2 5 4.26 18.1 17.8 11.6 12.4 13.4 14.3 14.9 16.3 18.0 20.7 Values other than V 10 ka are typical values. 40 ka 2

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Technical Data TD235027EN Residual voltage vs. impulse current Residual voltage (kv crest) 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 1000 10,000 Impulse current (A) 100,000 Figure 2. Maximum residual voltage vs. impulse current 1.8 1.7 1.6 No prior duty Per unit of Uc 1.5 1.4 1.3 1.2 After iec high current duty 1.1 1 0.01 0.1 1 10 100 1000 10000 Time duration in seconds Figure 3. Temporary overvoltage capability, 60 C NNote: The TOV capability will depend on the design and thermal capability of the arrester. The above TOV curve represents a typical Eaton Cooper Power series design. 3

Technical Data TD235027EN Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Power loss (watts) 0.500 0.450 0.400 0.350 0.300 0.250 0.200 0.150 0.100 0.050 0.000 0 200 400 600 800 1000 1200 Time (hours) Figure 4. Aging curve for AV5HG and AV5HE VariSTAR disks Aging factors based on the IEC and ANSI 1000 hour power loss tests are guaranteed to be less than or equal to 1. The 1000 hour test is performed at 115 C, which is equivalent to 110 years with the operating temperature at 40 C and operating voltages less than or equal to COV. See Figure 4. Factory routine tests performed on each disk Physical Inspection Residual Voltage Measurement (referenced to 10 ka, 8/20 μs) V 1mA/cm 2 (DC voltage at 12.97 ma) Power Loss @ 0.551 of V 1mA/cm 2 Voltage Table 3. Guaranteed characteristics based on 100% testing Catalog number AV5HEPA AV5HEPB Min. V 1mA/cm 2 (kv DC) 7.50 15.1 8.12 16.3 Max. V 10kA Top line digit 1 264535S A498 Top Line: Digit 1........................... Factory No. (May be numeral or letter designation) Digit 2........................... Last Digit of Year of Manufacture Digits 3, 4, 5, 6.................... Factory Lot Number Digit 7........................... Factory Use Only Second Line: Digit 1........................... Rating Code (See Table 4 below) Digit 2........................... Factory Use Only Digits 3 (& 4)..................... Disk Sub-category per Table 5 Figure 5. Disk identification system 4

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Technical Data TD235027EN Table 4. Disk category Rating code A B Catalog number AV5HEPA AV5HEPB Min. V 1mA/cm 2 (kv DC) Max. V 10 ka Test voltage kv rms Power loss test Watts @ 20 C 7.50 15.1 4.14 0.318 5.21 8.12 16.3 4.47 0.337 5.64 Min. V ref @ I ref of 5 ma Table 5. Disk sub-category Second line digits 3 (& 4) Minimum V 5kA Maximum V 5kA 20 11.91 12.00 21 12.01 12.10 22 12.11 12.20 23 12.21 12.30 24 12.31 12.40 25 12.41 12.50 26 12.51 12.60 27 12.61 12.70 28 12.71 12.80 29 12.81 12.90 30 12.91 13.00 31 13.01 13.10 32 13.11 13.20 33 13.21 13.30 34 13.31 13.40 35 13.41 13.50 36 13.51 13.60 37 13.61 13.70 38 13.71 13.80 39 13.81 13.90 40 13.91 14.00 41 14.01 14.10 42 14.11 14.20 43 14.21 14.30 44 14.31 14.40 45 14.41 14.50 46 14.51 14.60 47 14.61 14.70 Second line digits 3 (& 4) Minimum V 5kA Maximum V 5kA 48 14.71 14.80 49 14.81 14.90 50 14.91 15.00 51 15.01 15.10 52 15.11 15.20 53 15.21 15.30 54 15.31 15.40 55 15.41 15.50 56 15.51 15.60 57 15.61 15.70 58 15.71 15.80 59 15.81 15.90 60 15.91 16.00 61 16.01 16.10 62 16.11 16.20 63 16.21 16.30 64 16.31 16.40 NNote: For individual disk reference only. Not for ordering. Storage and handling The VariSTAR MOV disks are packaged on wooden pallets and secured for ocean container shipment. The pallet/boxes shall be stored indoors until the purchaser s acceptance test. Once opened, the disks shall be stored in a dry and clean environment to avoid moisture or other contaminants to collect on the disk surface. The MOV disk should not be handled with bare hands. A latex or other non-fibrous glove should be used to prevent contaminants from compromising the of the disk. 5

Technical Data TD235027EN Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv This page intentionally left blank. 6

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Technical Data TD235027EN This page intentionally left blank. 7

Technical Data TD235027EN Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv Eaton reserves the right to make changes to its product specifications, performance data or characteristics, at any time, without prior notice, and without creating any obligations on its part. Accordingly, the use of the information contained herein creates no liability on the part of Eaton. ISO 9001-Certified quality management system Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. TD235027EN Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series surge arrester product information call 1-877-277-4636 or visit:.