RELN Septic & Holding Tanks

Similar documents
Domestic Septic Systems

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Industries. Septic Tanks

Specifier s Document. Features and Benefits. Construction

tee Health Certificate of Accreditation Septic Tanks & Collection Wells

Leap into Spring! PolyPromos PREMIUM CORRUGATED WATER TANKS. Page 2 SAVE SAVE SAVE 2000L FIRE- FIGHTING SKIDS 1200L MASTER TUB TROUGHS FREE

Septic Tank. Installation Guidelines

Certificate of Accreditation

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

RX Tanks No Tank is built like an RX Tank

RX Tanks No Tank is built like an RX Tank

Grease Inspection Program

Sewerage Services.

INSTRUCTION MANUAL. Wireless Level Indicator

Bhagawati International Limited

Installation Instructions

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

1BGrease Traps and. Frequently Asked Questions About Grease:

The McCandless Township Sanitary Authority. Fats, Oils and Grease (FOG) Control Device. Design Guidance

SASKATCHEWAN AMENDMENTS TO APPENDICES OF THE NATIONAL PLUMBING CODE, 2005

ATLAS PLASTICS PRODUCT GUIDE

Commercial Sized Drainage

AUSTRALIA S BEST 4WD DRAWER SYSTEM

Aqua Green Utility Inc.

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

BioSTEP Screened Pumping System Installation & Service Manual

WSB clean: Installation Manual

HYDROCARBON SEPARATORS

PRODUCT GUIDE. March 2016 AUSTRALIA S #1 LADDER BRAND BAILEYLADDERS.COM.AU

COURSE # 343 UNIT 4: ADVANTEX WASTEWATER TREATMENT SYSTEM. What you will learn in this lesson

GREASE INTERCEPTOR REQUIREMENTS

Steel Products. 8M Series

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

PRODUCT DESCRIPTION 1500 RECT 2/C Gallon 2 Compartment Septic Tank TOP VIEW. Rectangular lid has optional

BECKLEY. General: Page 1

GAMMA Septic Tanks Installation & Operation Guidelines

GB-250. Submittal Specifications Installation Application Specific Details

WATER & WASTE management 2015 edition

ST. TAMMANY PARISH COUNCIL ORDINANCE

City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report

MAYO COUNTY COUNCIL KILLALA WASTE WATER DISCHARGE LICENCE APPLICATION ATTACHMENT C

OSCAR- LOWeFLOW Treatment System Homeowner s Manual. January 2016

Taps, Valves & Components. Section 1

Hampton Roads Planning District Commission

Mobile Food Unit / Pushcart Application

OEM GROUP (2006) Pty. Ltd. 1 McDonald Crescent. Bassendean, W.A Perth Western Australia. Phone: Website: -

Tank at Ground Level. Tank on Stand

Fats, Oils & Grease Ordinance and Program. Presented by Lance McAvoy Deputy Director of Operations

LIFTSON M-LIX L. LIFT-PUMP MODULES Domestic waste water 50 Hz Complies with standard EN RANGE OF APPLICATION APPLICATIONS ADVANTAGES

Turbine STEP System SIMPLEX OR DUPLEX

This pamphlet is a prevention information tool and is provided free of charge by the. Henderson Water Utility. and in conjunction with the

pump Hydrostorm ECO-V Energy Saving Variable 3 Speed Pump

Florida Community Services Corporation of Walton County d/b/a Regional Utilities (Regional) FOG Control Policy

Drain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS

LADDERS & ACCESS EQUIPMENT

CHATSWORTH WATER WORKS COMMISSION GREASE AND OIL CONTROL ORDINANCE

REGULATIONS CONCERNING TRAILER PARKS COBB PUBLIC HEALTH

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

PUMPS HIGH PERFORMANCE.

PUMPS AND EQUIPMENT

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

Tank Installation Instructions

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:

Below are details for liquid waste haulers on the process for discharging domestic wastewater at SA Water septic waste disposal stations (SWDS).

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

MIZU QUICK CHANGE DUAL FILTER SYSTEM

WASH UP TREATMENT SYSTEM

Inst all a ti o n and Oper a tin g Instru c ti o n s

Table of Contents. Item Page #

Breezair TBA 550 Installation Manual

Micron Commercial Fibreglass Filters

Ordinance No. FATS, OILS, AND GREASE CONTROL. Subdivision 1. General

Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities Information, Pollution Prevention, and Compliance Information

Rainsaver MK6 LEADERS IN QUALITY RAIN SAVING SYSTEMS

ORDINANCE NO. WHEREAS, the City of Lakeland wishes to institute rules and regulations on grease management for food service establishments:

Pretreatment Programs Fats, Oils and Grease FRWA Daytona 2015

pumps high performance

BATHROOM. COLLECTION Basins Showers Toilets Tapware

CATALOGUE SEWAGE MANHOLES

mixers tapware baths accessories toilets basins vanity troughs shower/shower systems sinks troughs and cabinets

Extended Warranty for total peace of mind

GB2 35/50 GPM Grease Interceptor for Indoor Use

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

mixers tapware baths accessories vanities vanity basin toilets troughs shower/shower systems sinks troughs and cabinets

PROTECTING THE TOOLS OF YOUR LIVELIHOOD

PLUS. 5 x 9. Magnetic Tray SKU x 11. Magnetic Tray SKU Four Powerful Magnets with Protective Rubber

Fats, Rags, Oils, and Grease Program. Bedford Regional Water Authority

MUDGUARDS MUDFLAPS & ACCESSORIES

A systematic approach to scale up FSM services Case of Government of Maharashtra

OWNER S MANUAL GREAT BASIN GREASE INTERCEPTORS

Section K. Cabtray - Cable Management System

Fats, Oils & Grease (FOG) Management Program Regulation # (Effective 04/01/2016) Introduction

At last, a Green Alternative to rubber, concrete and steel wheel stops!

AT Series Owners Instruction Manual Installation Manual, Operating Manual, Design Drawings and Specifications, Service Policy, Limited Warranty

INSTALLATION INSTRUCTIONS

Tel:

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Transcription:

RELN Septic & Holding Tanks New, Improved Tanks RELN s complete range of purpose designed black water tanks take quality and flexibility to the next level, with: Unique stepped ribs for greater strength A reinforced structural brace ring to prevent crushing A riser that provides greater flexibility for installation A 4,000L Septic and Holding Tank for increased capacity 15 Year Warranty Riser Australia s leading manufacturer of tanks RELN is an Australian owned company that pioneered modern developments in effluent disposal in the 1950s. Inlet and Baffle In 1990, we introduced the country s first injection moulded plastic septic tank that complied with Australian Quality Assurance Standards. Today RELN is a multi-award winning brand that continues to develop innovative products in conjunction with Council, Local Government and State Authorities. What is a Septic Tank? Septic Tanks provide an onsite sewage disposal system for homes on the urban fringe and in rural or remote locations. Effluent flows from the toilet, bathroom, laundry and kitchen into a tank, where liquids, fats, oils and solids are separated. Bacteria in the septic tank consumes the effluent, and leaves behind a liquid which flows on to an evapotranspiration field. The liquid is safely evaporated by wind and sun or transpired through plants. What is a Holding Tank? Holding tanks (also referred to as collection wells or pump out tanks) are used to hold effluent when it cannot be disposed of in an evapotranspiration field. These tanks collect effluent that overflows from a septic tank and store it for pump out by an effluent tanker and safe disposal at a town sewerage works. Holding tanks must be maintained at 1/2 capacity to prevent flotation. Structural Brace Ring RELN s black water product range also includes grease traps, drain trenching and drain matting. All RELN products are available throughout Australia and New Zealand in plumbing and hardware outlets. Visit our website for stockists.

Inspecton Cover Risers for Greater Flexibility RELN s 385mm riser seals to the top of the tank and allows the sewerage pipe to be buried deeper than usual, while enabling the tank s inspection covers and manhole covers to be maintained at ground level. 2 Man Hole Tank Lid UV Stabilised Polypropylene Baffle Unique Stepped Ribbing for Additional Strength Inlet T-Junction Inlet Outlet Anti Crush Tank 2 Riser rings can only be installed to tank bases that have a factory fitted reinforced structural base ring 3 Tank is pre drilled to suit Septic Tank or Holding Tank application Outlet T-Junction Reinforced Structural Brace Ring RELN s reinforced structural brace ring adds greater rigidity and prevents tanks from crushing when installed in deep ground. The brace ring is made from toughened polypropylene and welded inside our 3200L tanks with risers and 4,000L tanks. Component 3200L Holding Tank w/ Riser 3200L Holding Tank w/ Riser 4000L Holding Tank Tank Lid (Inc Man Hole and Inspection Covers) 3 3 3 3 3 3 Tank Base (Pre-Drilled) 3 3 3 3 3 3 3 Inlet 3 3 3 3 3 3 Outlet 3 3 3 Baffle (as per state requirement) 3 3 3 Baffle Riser 3 Installed Reinforced Structural Brace Ring 3 3 3 3 4 x Riser Panel Segments 3 3 3 3 Standard Septic/Holding Tank 3 3 3 3 3 3 Installation Instructions 3 3 3 3 3 3 Warranty Card 3 3 3 3 3 3

Australian Standards Approved AS/NZS1546.1:2008 On-site domestic wastewater treatment units Septic tanks Lic SMK1651. Strength by Design RELN tanks feature a unique stepped ribbing for added strength. Anti-Crush 3,200L Septic and Holding Tanks with Riser and 4,000L Septic and Holding Tanks come fitted with an innovative reinforced polypropylene structural ring that adds even greater rigidity to prevent crushing when installed deep in the ground. Greater Flexibility The 3,200L Septic and Holding Tank with Riser are an innovative system designed for sites that lack the necessary fall from the sewer exit point at the house to the septic tank. They offer more flexibility than any other septic system on the market. Easy to Transport Lightweight and easy to manage without a crane. 3200L Septic and Holding Tanks with Riser are packed with the riser kit stored inside the tank for delivery. Complete Kit RELN Septic Tanks are supplied as a complete kit including inlet and outlet T-Junctions. Holding Tanks are supplied with an Inlet T-Junction. Septic & Holding Tank Specifications Product Tank Height Tank Diameter Capacity 3200L 2038mm 1427mm 1998mm 1887mm 3200L 3200L w/ Riser 2410mm 1427mm 1998mm 2272mm 3200L 4000L 2410mm 1732mm 1998mm 2272mm 4000L Tank Diameter Tank Diameter Tank Height Tank Height

3200L Septic and Holding Tanks Meets the needs of three to four bedroom homes 1 RELN has manufactured Septic and Holding Tanks to meet Australian Quality Standards since 1990. These tanks, are ideal for properties with a suitable fall from the sewer exit point at the house to the septic tank. A baffle 4 is included in the kit if required by state health department regulations. Weighing in at just 122kg, 139kg with the baffle RELN s 3,200L tanks are lightweight and easy to install. 3200L Septic and Holding Tanks with Riser Meets the needs of three to four bedroom homes 1 RELN s 3200L Septic and Holding Tanks with Risers are ideal for projects that require a greater fall from the sewer exit point at the house to the septic tank. The tanks are fitted with RELN s innovative reinforced structural brace ring. A baffle 4 is included in the kit if required by state health department regulations. The tanks are robust yet easy to handle and light, weighing in at just 159kg or 177kg with the baffle. 4000L Septic and Holding Tanks Meets the needs of four to five bedroom homes 1 RELN s 4000L Septic and Holding Tanks are ideal for large households. The tanks are fitted with RELN s innovative reinforced structural brace ring and come complete with a strong, structural two piece baffle 4 that clips and screws into place to create two separate chambers, in accordance with authority requirements. The tanks are robust yet easy to handle and light, weighing in at just 159kg or 181kg with the baffle. 1 RELN recommends customers contact the local council for specific tank capacity requirements before purchasing a septic tank. 4 If required by state health department regulations, a baffle is included at an additional cost to the customer.

RELN s Blackwater range includes the following items Baffle 4 supplied if required by state health department regulations Standard Septic Tank 3200L Holding Tank 3200L Holding Tank Standard Holding Tank with Riser with reinforced structural brace ring factory fitted Riser sealing strip Baffle 4 supplied if required by state health department regulations Standard Septic Tank 4 x riser panel segments 28 x M8 316SS nuts, bolts and washers for riser fastening Riser sealing strip 3200L Holding Tank with Riser 3200L Holding Tank with structural brace ring factory fitted Standard Holding Tank 4 x riser panel segments 28 x M8 316SS nuts, bolts and washers for riser fastening Riser sealing strip base assembly 4000L Baffle 4 and assembly screws - supplied if required by state health department regulations Standard Septic Tank 4000L Holding Tank includes 4000L Holding Tank base assembly Standard Holding Tank Standard Septic/Holding Tank Inlet and outlet T-junctions (Holding Tanks only have inlet T-junction) 8 x 1.5m lengths of anchoring rope 8 x 10g 316SS self-tapping screws to fix T-junctions 8 x M6 316SS nuts, bolts and washers for fastening lid to the base 2 x inspection covers 6 x 10g 316SS self tapping screws to fix manhole cover to lid 2 x M6 316SS nuts, bolts and washers for fastening baffle Detailed installation instructions Warranty Card 4 Where required by state health department regulations, a baffle can be supplied at an additional cost to the customer. 3200L Holding Tank 3200L Septic w/ Riser 3200L Holing w/ Riser 4000L Holding Tank 11397 artone.com.au 08/10 For more information on installation and technical specifications, please visit www.reln.com.au