The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

Similar documents
4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

CappController Pipette Controller. Operation Manual Version: 1.2.

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

BlueSwan Pipette Controller

Never charge the batteries with a charger other than that supplied by the manufacturer.

Pipette Controllers OPERATOR INSTRUCTIONS

User s Manual. Pipette Controller for liquid handling. Thank you very much for purchasing Pipette Mate NEO.

LIQUID HANDLING TECHNOLOGY. User Manual Bedienungsanleitung

Progress made simple!

362 Clamp Meter. Users Manual

MANUAL. Single charger

CLASSIC. User s Guide. Do not lubricate this pipette. The use of lubricant cancels the warranty of this pipette. NOTICE

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

HST-BL-2830MS & HST-BL-2830MS-USA

Oil-free piston compressors KK and piston vacuum pumps KV

SPSR-115/230. Self-Powered Sensor

TABLE OF CONTENTS INTRODUCTION. Chapter 1. Parts Check List INTRODUCTION TABLE OF CONTENTS NOTICE INTRODUCTION 3

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

PIPETMAN ultra. EN ENGLISH User's Guide

Switching DC Power Supply

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Mod: KLD6-12/35XLAS-N

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Swing Piston Compressors and Vacuum Pumps

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

9. WARRANTY INFORMATION

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

i3000s/i2000 Flex AC Current Probe

Register your instrument! Easypet 3. Operating manual

OPERATING INSTRUCTIONS

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

SPSR-115/230. Self-Powered Sensor

362 Clamp Meter. Users Manual

NCSA 20plus Service Manual

365 Detachable Jaw True-rms Clamp Meter

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

TACH-10 Contact / Non-Contact Tachometer

DC Master 24/ A

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

PowerPlex 40V MAX Standard Battery Pack/Charger

PY-11 Voltage & Continuity Tester

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Register your instrument! Easypet 3. Operating manual

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

Charging base guide. A Sonova brand

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

3-Year Limited Warranty. See the Users Manual for the full warranty.

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

EX Series User Manual

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

Micro Diaphragm Gas Sampling Pumps

DALI 650mA LED Driver

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Instruction Manual 03

Go to to register your product and find more information.

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

original operating manual Operating manual Translation of the Item-No.: ,

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Operator s manual Manuel d utilisation Manual de instrucciones. BLi520x BLi940x

DSP led gaming monitor USER MANUAL

900 PEAK AMP PORTABLE JUMP STARTER

Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

233 True-rms Remote Display Digital Multimeter Safety Information

Register your instrument! Easypet 3. Operating manual

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Eppendorf Repeater Pro Instruction Manual Manual de Instrucciones

Battery Charger JCB- SCH20LI.2

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

373 Clamp Meter. Users Manual

Easypet 3. Operating manual

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

302+/303 Clamp Meter. Users Manual

IMC. Battery Charger. Instruction Manual

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

Progress made simple!

3.25 Ton Heavy Duty Floor Jack

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

Bibbyjet Pipette Controller. Fingertip control... technology & ergonomics in harmony

DIAPHRAGM LIQUID PUMP NF 1.30

Operating instructions

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

PURE SINE WAVE DC TO AC POWER INVERTER

Clinispin CT20 User Manual

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Operating instructions Accu Jet

Gavita HortiStar 1000 DE EU/US

IN120L / IN120LB / TM120L/TM120LB IN2400L

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

STRX-9 100% TAKE CONTROL INSTRUCTION MANUAL READY-TO-RUN. w/ Adult Supervision

Language specific user manuals are available on

323/324/325 Clamp Meter

Compact Scales. Software Revision V1.25 & above

Register your instrument! Eppendorf Reference 2. Operating manual

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

IN & TM Series User Manual

Transcription:

The Efficient Solution for Pipetting up to 100 ml at once!

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the User s Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interface at his own expense. EC- Declaration of Conformity MACROMAN is in accordance with EC directives: 2006/95/EC Low voltage equipment 2004/108/EC Electromagnetic compatibility 2011/65/EC Restriction of hazardous substances 2002/96/EC Waste electrical and electronic equipment 2009/129/EC Eco design directive 2006/66/EC Battery directive. Warranty Gilson warrants this product against defects in material under normal use and service for a period of 12 months from the date of purchase. Gilson is not responsible for incidental damage resulting from physical shock, continuous exposure to corrosive reagents or technical handling not in accordance with the guidelines described in the User s Guide. Contents Page 1 - SAFETY SYMBOLS USED 3 2 - PROPER USE 3 3 - SAFETY PRES 3 Possible dangers if the safety precautions are not observed 3 Safety at work 3 Safety aspects for the user company 3 Restrictions of use 4 Changes in configuration / design by user 4 4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4 5 - CHARGING THE MACROMAN 5 6 - USING THE MACROMAN 5 Plug in the pipette 5 To fill the pipette 6 To discharge the pipette 6 Regulation of the suction and discharge speed 6 7 - CLEANING/DISINFECTION 6 Disinfecting the MACROMAN 6 Changing the filter 6 8 - REPLACING THE BATTERIES 7 9 - EQUIPMENT DISPOSAL 7 10 - TROUBLESHOOTING (FAQ) 8 11 - TECHNICAL DATA 8 12 - SPARE PARTS AND ACCESSORIES 9 13 - MANUFACTURER AND CUSTOMER SERVICE 9 NOTES 10 1 SAFETY SYMBOLS USED This manual contains the following symbols, compliant with which is essential. The symbols signify the following: DANGER Indicates possible danger of personal injury or death. Comply with the instructions. Indicates possible damage to the instrument. Comply with the instructions. 2 PROPER USE MACROMAN is designed for the reproductible pipetting and dispensing of liquids. The instrument must not be used for any application other than those specified. 3 SAFETY PRES Possible dangers if the safety precautions are not observed MACROMAN is a state-of-the-art instrument with respect to current technology and is safe to use. Some danger may arise if untrained personnel use the instrument. All persons working with the MACROMAN must read the operating and safety instructions before operating the instrument. Safety at work Independent of any safety precautions listed here, all other relevant safety aspects e.g. GLP, GMP, professional trade associations, Department of Health, trade supervisory authorities must be observed. Safety aspects for the user company The supervisors of operating personnel must have read and understood all the safety precautions involved and must ensure that these are adhered to. They must also ensure that operating personnel also understand and observe all safety rules. DANGER The instrument must not be used or recharged in an atomosphere with danger of explosion. Highly flammable liquids must not be pipetted (flash point below 0 C, e.g. Ether, Acetone). - 2 - - 3 -

Please dispose the NiMH-batteries according to the relevant provisions. Restriction of use The instrument must not be used with solvents whose vapors are incompatible with the materials ABS, POM, FPM, NBR, CR, Silicone. Changes in configuration / design by user No changes may be made to MACROMAN. Any parts that become defective must be replaced by original GILSON parts. MACROMAN may not be altered in design or in any of their safety aspects without the express written permission of GILSON. In particular, no alterations may be made to any of the protective functions. Any alteration made releases GILSON from any liability for damage caused. DANGER MACROMAN and the transformer may not be opened! Repairs must be carried out by GILSON or a service company authorised by GILSON. 5 CHARGING THE MACROMAN Plug the cable of the mains adapter into the MACROMAN or the charging station (status LED is green). The green light indicates that batteries are being charged and mains adapter is connected. Charge the battery for 10 hours before operating MACROMAN for the first time. It cannot be overcharged. If the red light is permanently on, the batteries have discharged to below 10% recharging is required. The MACROMAN may be used while recharging. Ensure that you are using an original Gilson mains adapter (100-240 VAC, 50/60 Hz) - F1077527. The mains adapter must not be used for any other electrical equipment but only the MACROMAN. Direct charging of the MACROMAN Charging the MACROMAN in the charging station 4 SETTING UP THE MACROMAN CHARGING POSITION Wall mounted The charging station may be fixed to a wall by the following means: double sided self-adhesive tape (1), or, magnetic tape attached to wall (1), or, screw through centre of the charging station (2). Workbench set-up Rubber feet on the bottom of the charging station prevent slipping (3). 6 USING THE MACROMAN Plug in the pipette Pipette 2 ml : place the pipette mount with the small hole on top (1). Pipette 2 ml : place the pipette mount with the large hole on top (2) - 4 - - 5 -

To fill the pipette: Press the filling control button (3) To discharge the pipette: Press the discharge control button (4). Regulation of the suction and discharge speed: By using the pump speed control (5). Fine control over the fluid meniscus in the pipette can be achieved by alternately pressing the filling and discharge buttons for longer or shorter periods, as required. 7 CLEANING/DISINFECTION OF THE MACROMAN 8 REPLACING THE BATTERIES Only use original GILSON rechargeable batteries (1.2 V AAA NiMH/1000 mah). Replacement procedure Take out the silicone plug (1). Open the screw (2). Pull out the flexor (3). Open the battery cover (4). Change the batteries (1.2 V AAA NiMH/1000 mah). Check the correct polarity of batteries (+/-) before closing the cover. DANGER - Always disconnect the MACROMAN from the power supply before cleaning. Never use acetone to clean the MACROMAN. Use only commercially available cleaning agents, such as alcohol (isopropyl alcohol) to clean your MACROMAN. Disinfecting the MACROMAN Pipette nose piece (1), pipette mount (2) and filter rubber (4) are autoclavable at 121ºC. Changing the filter The sterile filter (3) should be changed every three months, or if the suction rate of MACROMAN becomes too low. 9 EQUIPMENT DISPOSAL The MACROMAN is labelled with the crossed-out wheeled bin symbol to indicate that this equipment must not be disposed of with unsorted municipal waste. Instead, it is your responsibility to correctly dispose of your waste equipment by handing it over to an authorised facility for separate collection and recycling. It is also your responsibility to decontaminate the equipment in case of biological, chemical, and/or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of equipment. For more information about where you can drop off your waste equipment for recycling, please contact your local dealer from whom you originally purchased the product or your local council. By doing so, you will help conserve natural resources and you will ensure that your waste equipment is recycled in a manner that protects human health and the environment. Thank you! - 6 - - 7 -

10 TROUBLESHOOTING (FAQ) 12 SPARE PARTS AND ACCESSORIES Problem Possible Cause Remedy Lamp lights up permanently red. Batteries are discharged. Charge the batteries. Liquid is not aspirated. Missing or defective batteries. Check that batteries have been inserted. Charge the batteries. Replace the batteries. 11 TECHNICAL DATA Dimensions (LxWxH) MACROMAN: 130 x 145 x 35 mm Charging station: 175 x 75 x 80 mm Mains adapter: 75 x 45 x 45 mm Weight MACROMAN: Charging station: Mains adapter: Power supply Mains adapter: Instrument: 190 g 240 g 190-300 g Battery Rechargeable batteries: 2 x 1.2 VAAA NiMH/1000 mah Pipettor nose piece not tight. The filter in the pipettor nose piece is wet and/or clogged. 100 240 VAC 50/60Hz input 9 VDC, 500 ma output 9 VDC Tighten the nose piece Replace the filter. Operating condition Operation: 5 40 C, max. 80 % RH Storage: -10 to 50 C, max. 80 % RH UV-Resistance: If the MACROMAN will be exposed to ultraviolet light, the plastic housing might discolour and become yellowish. This will not affect the functioning efficiency of the device. Ordering information Filter rubber Filter sterile (0.45µm) Filter not sterile (0.45µm) Filter sterile (0.20µm) Filter not sterile (0.20µm) Pipette mount, silicone Pipette nose piece Batteries (2 pieces 1.2 V AAA, NiMH/1000mAh) Battery cover set Charging station, Gilson MACROMAN Mouting kit for charging stand (magnetic and self-adhesive tape, screw) Mains adapter (100 240 VAC, 50/60 Hz) with 4 plugs Side stand Wall mount Trigger cap Adapter for D5000 and 10 ml PIPETMAN Diamond Tips (not shown) Part Number F1077502 F1077525 F1077504 F1077526 F1077503 F1077505 F1077506 F1077507 F1077509 F1077528 F1077510 F1077527 F1077523 F1077530 F1077517 F16128 13 MANUFACTURER AND CUSTOMER SERVICE Manufacturer: Gilson SAS 19 avenue des Entrepreneurs, BP 145 95400 Villiers-le-Bel, France www.gilson.com Customer service: Please contact your local Gilson distributor. You will find their name and address on our web site www.gilson.com - 8 - - 9 -

NOTES - 10 - - 11 -

www.gilson.com sales@gilson.com service@gilson.com training@gilson.com LT801546/A - 2014 Gilson SAS All rights reserved August 2014 English Printed in France Specifications subject to change without notifications - errors omitted. Gilson, Inc. World Headquarters I 3000 Parmenter Street I P.O. Box 620027 Middleton, WI 53562-0027, USA I Tel: (1) 800-445-7661 or (1) 608-836-1551 I Fax: (1) 608-831-4451 Gilson S.A.S. I 19, avenue des Entrepreneurs I BP 145, F-95400 Villiers-le-Bel, France Tel: +33 (0) 1 34 29 50 00 I Fax: +33 (0) 1 34 29 50 20