Similar documents
NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

SimpliPhi Power PHI Battery

Microgrids Outback Power Technologies

CALL FOR A QUOTE (877)

Saft telecom batteries

The wind/solar hybrid controller is the control device which can control wind turbine and solar panel at the same time and

PowerStor Standby Battery Systems

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Instruction of Solar Charge Controller. User s Manual

Prepared for 7 x 24 Exchange

list in Sealed Lead Acid ( SLA )batteries from Japan more than 150,000 units of batteries every month on

The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

SOLAR BATTERIES E X P E R I E N C E THE EXCELLENCE

off-grid Solutions Security of supply Basics: Off-grid energy supply

Plug Into the Current Future

ALL IN ONE SMART SOLAR STREET LIGHT-FLY HAWK SERIES (2016)

Narada high temp. battery

NorthStar Battery (NSB) Telecom Application Manual

Charging pure lead-tin batteries:

Solar-Wind. Solar-Wind Hybrid LED Street light. Advantages and Benefits

INTRODUCING THE LEAD CRYSTAL BATTERY

SimpliPhi Power PHI Battery

Reliability. Safety. Efficiency.

bosfa spiral lead acid battery

Plug Into the Current Future

Offshore Platform Installations

Plug Into the Current Future

RENEWABLE BROCHURE. World Class Battery Engineering Flooded & AGM Batteries

Distributed Storage Systems

AlphaCell RE Batteries. Copyright 2010 The Alpha Group. All Rights Reserved.

Polymer Gel Standby Battery (Front Access Design) OPERATION MANUAL

Lithium-ion battery systems for ABB UPS solutions Reliable, lightweight and compact UPS energy storage for critical applications

SimpliPhi Power PHI Battery

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Pure Lead-Tin Technology

01 PRONTOFORZ PRONTOFORZ 02

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Custom Power Solar Radian Battery Energy Storage System

Key advantages of our Telecom products

TYPE TEST REPORT. OPzS CELLS AND BLOCK BATTERIES. According to IEC

House/Building Wind Power Storage Facility Supply Factory Supply. Ferry Energy Adjustment Grid Peaking Shaving

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

The Ampetus Super Lithium Battery 10 year standard warranty extendable to 15 years!

80V 300Ah Lithium-ion Battery Pack Data Sheet

Z21 SERIES HYBRID GENERAL BATTERIES. Q: Can this be used as an Off-Grid inverter?

SimpliPhi Power PHI Battery INTEGRATION GUIDE: OUTBACK POWER. Power. On Your Terms.

The introduction of Lead Crystal Battery

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Company Introduction. Established: YEARS. Investment: More than 30 million US Dollar. Factory Area: 220,000 square meter.

How To Set Up SimpliPhi Batteries Using OutBack Chargers

Narada + Partners Solution

6 & 12 Volt Monobloc GEL Range

VRLA gel battery. power the future

NorthStar Battery Company DOC Code: SES DCR-721-S05 Date:

GEL Technology

Instruction of Solar Charge Controller. User s Manual

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

NorthStar Battery Company DCN: SES DCR: 1413-S08 Date:

AEG Belgium customer day Telecom products & systems

LEADING BATTERY ENERGY STORAGE SOLUTIONS AVAILABLE FROM FREEDOM WON (DATA SHEETS AVAILABLE UPON REQUEST) Freedom Lite Home & Business

1.5KW HF/PFC Lithium Battery Charger. 2KW HF/PFC Lithium Battery Charger

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

Solar-and-plus Lithium Battery Energy Storage System

SLB SMART LITHIUM BATTERIES JOIN THE EVOLUTION FROM LEAD TO LITHIUM

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Enphase AC Battery Parameters for NREL System Advisor Model (SAM)

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

S-PPC. Product Brief. Power Plant Controller Solutions for Energy Storage Systems

AARHUS UNIVERSITET FLOW BATTERIER PÅ VEJ IND I KOMMERCIEL DANSK SERIEPRODUKTION

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

BMS-3923 Battery Monitoring System

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Types batteries. AGM Gel OpZs OpZv Lead Carbon LiFePO4 NCA Saltwater Zinc Bromine Etc,etc, etc, etc, etc, etc,

Renewable Hybrid / Off-grid Solutions

Robert Strong P.E. Critical Facilities Technology

Tubular Gel Technology For Solar Applications

30A PWM Solar Charge Controller with LCD Model: PWM30CC-LCD

ESS Batteries by Samsung SDI

Industrial Standby batteries. A wide offer of reliable, long-life solutions

The Traveler Series: Wanderer

Move with the SUN All DC Solar Systems. Green Power Outsourcing. GSMA SEA working group. July 24-25, Mr. TK Shih.

Automatic DC Power Supply/Battery Charger

SENTINEL BATTERY MONITORING

Industrial Batteries / Network Power. Classic Solar.»Powerful energy storage for renewable energy systems«

Winter 2016 Conference

Instruction of Solar Charge Controller. User s Manual

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

Advanced Alternative Energy Solutions HSS. Hybrid Storage Solution HYBRID ALTERNATIVE ENERGY STORAGE COMBINED WITH INTELLIGENT CONTROLS

6 & 12 Volt Monobloc. Haze Battery Company Ltd

TES 5 K. On - & Off-Grid Storage Solutions. Data Sheet TES 5 K Data Sheets Battery IN COOPERATION WITH. Energietechnik Lisges

MPPT-30 Solar Charge Controller

Ideal substitute for lead-acid batteries. Safe and absolutely environmentally friendly technology offers alternative to common lithium-ion batteries.

Off-grid Power for Wireless Networks. Training materials for wireless trainers

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

UniverSOL Charge Station

Electric Transportation and Energy Storage

Transcription:

Coslight Telecom LFP Battery System I. Brief Introduction GYFP-T Series LFP Battery System is high-tech product, which is developed independently by COSLIGHT. It has outstanding advantages in certain occasions of telecom power supply field, such as clean energy, environment friendly, small in size, light in weight, long cycle life, good performance in high temperature, good power characteristic and etc. II. Outstanding Advantages in Certain Occasions The advantages of small in size and light in weight are suitable for small size base station in large city. Take 48V 100AH LFP Battery System as the example: Item LFP Battery VRLA Battery Comparison Dimensions 540 220 365 mm(l W H) 550 440 270 mm(l W H) LFP Battery is 65% of VRLA Battery in volume Weight 70kg 148kg LFP Battery is less than 50% of VRLA Battery in weight Floating Lifetime of LFP battery can reach more than 20 years for using in Class I (10 hours/month of grid power outage) and Class II (10 hours/week of grid power outage) area under the intelligent management of BMS. - 1 -

The advantage of long cycle life is suitable for Class III (2-8 hours/day of grid power outage) and Class IV (more than 8 hours of grid power outage) area. LFP battery cyclic curve in 25 VRLA Battery cyclic curve in 25 LFP battery cyclic curve in 45 VRLA Battery cyclic curve in 45 Seeing from the curve: In 25, LFP battery is 17 times of VRLA Battery in cycle life. In 45, LFP battery is 13 times of VRLA Battery in cycle life. While LFP battery is 5 times of VRLA Battery in cost. So LFP battery has high cost performance, and the annual average price is just 30% of VRLA battery. - 2 -

The features can reach the advantage especially in scenarios as below: Class III area No grid power area, but rely on DG and battery system No grid power are, but rely on solar and battery system III. Advanced BMS Advanced BMS with overdischarge, overcharge, overcurrent and overheat protection to ensure communication. Optimize the management of float charging. Remote monitor and control of system by GPRS. The BMS can work compatibly with existing high frequency switching power supply system. Combine the LFP battery and existing VRLA Battery through BMS. IV. Technical Parameters of 48V LFP Battery Rated Voltage 48V Charge Voltage 54V Cut-off Discharge Voltage 42V Charge Current 0.6C 5 Discharge Current 0.6C 5 Charge Temperature 3 50 Discharge Temperature -20 55 Storage Temperature -30 60-3 -

V. Recommended Application: Scenario I: Replace the VRLA battery by lower capacity of LFP battery LFP battery can be charged rapidly, so it can adopt 0.6C5 to charge the battery. And there is no irreversible capacity attenuation. In Class III area,supposed that we change the existing VRLA battery to LFP battery in same capacity, although the annual average price is just 30% of Lead acid battery, while the one-time purchase cost is 5 times of Lead acid battery, which may be challenge for customers to accept. So we suggest that the customers can choose the LFP battery with 20% 30% capacity of VRLA battery. For example: If the load current is 20A, 4 times power failure every day, and no more than 2 hours every time, you can choose 48V 100AH LFP battery and charge current can be limited between 40A 60A. If the load current is 30A, 4 times power failure every day, and no more than 2 hours every time, you can choose 48V 150AH LFP battery and charge current can be limited between 40A 60A. According to the scheme above, purchasing price of every time for LFP battery is similar with the one for VRLA battery, but the using life of LFP battery is 2 times longer than that of VRLA battery. - 4 -

Comparison between Using Lead-acid Battery and Using LFP Battery Existing lead-acid battery Change for LFP Battery Type 48V 600AH 48V 150AH Cost About 21600 About 26800 Power supply mode Expected life time Three class power supply 4 times power failure every day and no more than 2 hours every time 2 years Three class power supply 4 times power failure every day and no more than 2 hours every time 4 years Scenario II: Combine the LFP battery with existing lead-acid battery together If the load is less than 1.5KW in Class III area, and there is already lead-acid battery in base station, if so, just add one set of 48V 100AH LFP battery. And Using the LFP battery with existing lead-acid battery together through the management of BMS can lengthen the service life of original VRLA battery. The LFP battery will charge and discharge preferentially when four grid outages in one day, and every time is less than 2 hours. While the VRLA battery will begin to work when every outage is more than 3 hours and the capacity of LFP battery is not enough to supply. So just add one set of 48V 100AH LFP battery with the cost of 20000. The service life of LFP battery is two times as long as that of VRLA battery, and can increase the service life of existing lead-acid battery more than one time. That is an excellent scheme. If the load is less than 1.5KW in Class III area with frequent power failure, and there is already lead-acid battery and DG for power - 5 -

supply in base station, if so, just add one set of 48V 100AH LFP battery. And Using the LFP battery with existing lead-acid battery and DG through the management of BMS can not only lengthen the service life of original VRLA battery, but also reduce the starting times of DG and save the fuel, which will lengthened the service life of DG immensely. If the load is 3.0KW,48V 200AH LFP battery will be suitable. VI. GYFP-T Series Telecom LFP Battery System Five series are available as below: GYFP-TC series: Cabinet battery system GYFP-TS series: Rack battery system GYFP-T series:(etsi 19 inches rack)battery system GYFP-TX series:(etsi 19 inches/narrow Module)battery system GYDY-FP-T series: LFP battery integration power system As the newest generation of battery products, LFP battery will replace the lead-acid battery for telecom using with the outstanding advantages of clean energy, environment friendly, small in size, light in weight, long life and etc. We hope to carry forward these superiorities of LFP battery to better. - 6 -