Full Starters Style SO, -Pole Starter lass 86 / Refer to atalog 80T70 eneral Information S magnetic starters are used for full-voltage starting and stopping of squirrel cage motors. overload protection is provided via melting alloy type thermal overload relays. S starters are available in s 00 through 7, and are designed for operation at Vac, 0 to z. Solid State Overload Relay Protection ( Logic ) These ambient insensitive overload relays are available on s 00 through 6 and standard on size 7. They provide phase loss, phase unbalance protection. To order, add Form 0 (for selectable trip class or 0 protection). For more information about Logic, see pages 6-8 and 6-. dapted Bimetal ( s 00 ) The dapted Bimetal motor starter consists of a specially designed adapter that attaches with bus bars to the S contactor and holds the LRD or LRD (IE Style) bimetal overload relay. This starter configuration can be ordered by adding Form E (adapater only) to the standard catalog number. Once the FL of the motor has been determined, the LRD or LRD bimetal overload can be purchased separately and installed in the field at a later date. For more information see Table 6.6. TeSys T Management System ( s 6) TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T can predict what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. For additional information about TeSys T Management System, see pages 6-84 to 6-88 and page 6-. -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units (s 00 6). Standard trip thermal units are $.0 each. See page 6-6 Table 6.: 00 -/ -/ Open 4 & 4X Brushed Stainless Steel ( 0-)a 4X, orrosion-resistant lass-polyester SOb 86.00 Sb 4.00 Use 0 Use 0 0 8 SBOb 48.00 SBb 8.00 SBWb 7.00 SBWb 7.00 Schneider Electric offers express shipping for factory modified and /R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. sk for Laser Delivery, then select the product and the modifications you need when you place your order. It s as easy as that! 7 4 4 70 7-/ 7-/ 0 0 0 0 0 0 7 0 SOb 7.00 Sb.00 SWb.00 SWb.00 SDOb.00 SDb.00 SDWb 86.00 SDWb 86.00 SEOb 68.00 SEb.00 SEWb 80.00 SEWb 46.00 SFOb 7.00 SFb.00 SFWb 687.00 SFWb 8.00 SOb.00 Sb 4.00 SWb 7.00 6 0 0 0 SOb 76.00 Sb 888.00 SWb.00 6 /DEFINITE PURPOSE TYPE 7 8 00 SJOb 6.00 SJb 88.00 SJWb.00 a 6 and 7 are rated 4 only, painted sheet steel. b oil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. 6-8 Discount 0 Schneider Electric P
Full Starters Style lass 86 / Refer to atalog 80T70 Table 6.4: -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units (s 00 6). Standard trip thermal units are $.0 each. See page 6-6 Ironb Bolted luminumd 7 & For azardous Locations Div. & lass I roups, D lass II roups E, F, & SPIN TOP /Ra Dusttight & Driptight Industrial Use 00 -/ -/ Use 0 Use 0 Use 0 0 8 SBTc SBT4c 0.00 SBRc 6.00 SBc 68.00 7 7-/ 7-/ STc ST4c 4.00 SRc 804.00 Sc 76.00 4 SDTc SDT4c 6.00 SDRc.00 SDc.00 0 0 0 SET4c 4.00 SERc 6800.00 SEc 8.00 4 0 0 0 SFT4c 8778.00 SFRc 7.00 SFc 74.00 70 7 0 ST4c 070.00 SRc 6.00 Sc 86.00 6 0 0 0 Sc 77.00 7 8 00 SJc.00 a enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. b Limited to Pilot Light and Selector Switch or Start-Stop Push-Button. c oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection Table 6.4 shown on page 6-8. d 7 and bolted cast aluminum are not UL listed. Table 6.4: oil odes z 0 z 4e 0f 08 77 0 4 0 ode V0 V0 V08 V0 V04 V06 V07 V dder. Schneider Electric offers express shipping for factory modified and /R Enclosed Starters. When you need them fast, our Laser Delivery program is the answer to getting your product when you need it most. sk for Laser Delivery, then select the product and the modifications you need when you place your order. It s as easy as that! e 4 V coils are not available on s 4 7. On s 00-, where 4 V coils are available, Form S (separate control) must be specified (i.e., order as 86SBOV0S). f 0 Volt Polyphase contactors are wired for separate control. Form S (separate control) must be specified (i.e., order as 86SOV0S). Note: For voltage codes used with control transformers, see page 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions...........................................page 6-4 Factory Modifications (Forms)...........................page 6-0 Separate s (lass ).........................page 6- Replacement Parts (lass 8).........................page 6- S ccessories (lass ).........................page 6-8 For ow to Order Information, see page 6-. /DEFINITE PURPOSE TYPE 6 0 Schneider Electric P Discount 6-
Full Starters -Pole Vac Maximum0 z lass 86 / Refer to atalog 80T70 Table 6.4: Note that prices shown do not include thermal units. Devices require thermal unit. Standard trip thermal units are $.0 each. See page 6-6 00 / Open 4 & 4X Brushed Stainless Steel 4X, orrosion-resistant lass-polyester SOa 86.00 Sa 4.00 Use 0 Use 0 0 8 SBOa 4.00 SBa 468.00 SBWa 66.00 SBWa 66.00 7 SOa 07.00 Sa.00 SWa.00 SWa.00 P 6 SOa 66.00 Sa 66.00 SWa 0.00 SWa 0.00 4 7-/ SDO6a 8.00 SD6a 67.00 SDW6a 0.00 SDW6a 0.00 4-Pole, - Vac Maximum0 z Table 6.44: Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page 6-6 Open 4 & 4X Brushed Stainless Steel 4X, orrosion-resistant lass-polyester 0 8 SBOa 6.00 SBa 67.00 SBWa.00 SBWa.00 7 7-/ 7-/ SO4a 74.00 S4a 76.00 SW4a.00 SW4a.00 4 SDOa 8.00 SDa.00 SDWa.00 SDWa.00 4 0 0 0 0 0 0 SEOa 06.00 SEa 7.00 SEWa 6.00 SFOa 4.00 SFa 7.00 SFWa.00 onsult Schneider Electric at (-888-778-7) a oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed below. Table 6.4: oil odes z 0 z ode dder 6 /DEFINITE PURPOSE TYPE 4b 0c 08 77 0 4 0 V0 V0 V08 V0 V04 V06 V07 V b 4 V coils are not available on s 4 7. On sizes 00, where 4 V coils are available, Form S (separate control) must be specified (i.e., order as 86SBOV0S). c 0 Volt Polyphase starters are wired for separate control. Form S (separate control) must be specified (i.e., order as 86SOV0S). Note: For voltage codes used with control transformers, see 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions........................................... page 6-4 Factory Modifications (Forms)........................... page 6-0 Separate s (lass )........................ page 6- Replacement Parts (lass 8)......................... page 6- S ccessories (lass )........................ page 6-8 For ow to Order Information, see page 6-.. 6-0 Discount 0 Schneider Electric P
Full Starters -Pole Vac Maximum0 z lass 86 / Refer to atalog 80T70 Table 6.46: Note that prices shown do not include thermal units. Devices require thermal unit. Standard trip thermal units are $.0 each. See page 6-6 00 / Ironc Bolted luminuma 7 & azardous Locations, Div. & lass I, roups & D lass II, roups E, F, & SPIN TOP /Rb Dusttight & Driptight Industrial Use Use 0 Use 0 Use 0 0 8 SBTd SBT4 0.00 SBRd 6.00 SBd 6.00 7 STd ST4 86.00 SRd 7.00 Sd 7.00 P 6 STd ST4 6.00 SRd.00 Sd 867.00 4 7-/ SDT6d SDT46.00 SDR6d 40.00 SD6d 80.00 a 7 and bolted cast aluminum are not UL listed. 4-Pole - Vac Maximum0 z Table 6.: Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page 6-6 oil Ironc Bolted luminum 7 & azardous Locations lass I, roups & D lass II, roups E, F, & SPIN TOP /R b Dusttight & Driptight Industrial Use 0 8 08 SBTd 48.00 SBRd.00 SBd 846.00 7 7-/ 7-/ 08 ST4d 4.00 SR4d 0.00 S4d.00 4 08 SDTd onsult Schneider Electric at (-888-778-7) 7.00 SDRd.00 SDd 74.00 4 0 0 0 0 0 0 08 08 onsult Schneider Electric at (-888-778-7) SERd 867.00 SEd 76.00 SFd 770.00 b enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. c Limited to Pilot Light and Selector Switch or Start-Stop Push-Button. d oil voltage code must be specified to order this product. Refer to standard coil voltage codes listed on page 6-0. Dimensions...........................................page 6-4 Factory Modifications (Forms)...........................page 6-0 Separate s (lass ).........................page 6- Replacement Parts (lass 8).........................page 6- S ccessories (lass ).........................page 6-8 For ow to Order Information, see page 6-. 6 /DEFINITE PURPOSE TYPE 0 Schneider Electric P Discount 6-
Full Starters Style lass 86 / Refer to atalog 80T70 s SB SD With uxiliary Load Terminals It is sometimes desirable to use capacitors in motor branch circuits to improve power factor. The 0 SB SD starters listed below include three auxiliary terminals to allow easy connection of power factor correction capacitors. When capacitors are connected using these terminals, no adjustment to the selection of thermal units is necessary. The auxiliary terminals accept # 6 solid or stranded wire. & 4 starters have provisions for auxiliary connections. User must supply lugs as necessary. The S starters with auxiliary load terminals may also be used to control two motors simultaneously from a single starter. owever, this application is tightly restricted by Section - of the National Electrical ode. Refer to the NE for restrictions regarding overload protection, size of controller and motor branch circuit protection. Table 6.48: -Pole Polyphase Vac Maximum0 z Note that prices shown do not include thermal units. Devices require thermal units. Standard trip thermal units are $.0 each. See page 6-6 0 Open SBTOa 48.00 7-/ 7-/ STOa 7.00 SDTOa.00 Extra apacity Starters (Not Style) -Pole 0 Vac Maximum0 z Table 6.4: Note that prices shown do not include thermal unit. Devices require thermal unit. Standard trip thermal unit is $.0 each. See page 6-6 Open R Rainproof, Sleet Resistant, Outdoor Use 4 & 4X Brushed Stainless Steel 4X Watertight orrosion Resistant lass-polyester /R c Dusttight and Driptight Industrial Use SDO8ab 4.00 SD8ab 787.00 6 /DEFINITE PURPOSE TYPE 7-/ SEO6a 4.00 SE6a 7.00 SE6a 0.00 SEW6a 76.00 SEW6a 6.00 SE6a 0.00 a oil voltage code must be specified to order this product. Refer to standard coil voltage codes shown below. b Uses a overload relay. c enclosures may be field modified for outdoor non-corrosive and non-service-entrance-rated applications; see page 6- for more information. Table 6.0: oil odes z 0 z 4d 0e 08 77 0 4 0 ode V0 V0 V08 V0 V04 V06 V07 V. d 4 V coils are not available on s 4 7. On s 00, where 4 V coils are available, Form S (separate control) must be specified. e 0 Volt Polyphase starters are wired for separate control and must be ordered with Form S (i.e., 86SOV0S). Note: For voltage codes used with control transformers, see page 6-. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is supplied at no charge. Dimensions........................................... page 6-4 Factory Modifications (Forms)........................... page 6-0 Separate s (lass )........................ page 6- Replacement Parts (lass 8)......................... page 6- S ccessories (lass )........................ page 6-8 For ow to Order Information, see page 6-. dder 6- Discount 0 Schneider Electric P
pplication Data for Selection Table 6.: Load Maximum Rating Nonplugging and Nonjogging Duty Full ontactors and Starters Style Maximum Rating Plugging and Jogging Duty a Rating, () Volt Service Limit Rating, () b Tungsten and Infrared Lamp Load, () 0 Volts c Resistance eating Loads, KW other than Infrared Lamp Loads d lass 80, 86 / Refer to atalog 80T70 KV Rating for Switching Transformer Primaries at 0 or ycles Ø Inrush s (Worst ase Peak)? 0 Times Peak of Rating Inrush s (Worst ase Peak) > 0 Times Peak of Rating Rating for Switching apacitors e KVR 00 80 / -/ -/ -/ 0 P 4 6f 80 80 80 80 80 80 80 7-/ 7-/ 7-/ 0 0 0 0 0 7 0 0 7 0 0 0 00 0 0 / -/ 00 7f Tables and footnotes are taken from Standards. -/ -/ -/ a shown are for applications requiring repeated interruptions of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal, involving more than five openings or closings per minute and more than ten in a tenminute period, such as plug-stop, plug-reverse or jogging duty. apply to single speed and multi-speed controllers. b Per Standards paragraph IS -.0, the service-limit current represents the maximum rms current, in mperes, which the controller may be expected to carry for protracted periods in normal service. t service-limit current ratings, temperature rises may exceed those obtained by testing the controller at its continuous current rating. The ultimate trip current of over-current (overload) relays or other motor protective devices shall not exceed the service-limit current ratings of the controller. c FLUORESENT LMP LODS00 VOLTS ND LESSThe characteristics of fluorescent lamps are such that it is not necessary to derate lass 80 contactors below their normal continuous current rating. lass 8 contactors may also be used with fluorescent lamp loads. For controlling tungsten and infrared lamp loads, and resistance heating loads, lass 8 lighting contactors are recommended. These contactors are specifically designed for such loads and are applied at their full rating as listed in the lass 8 Section. d apply to contactors which are employed to switch the load at the utilization voltage of the heat producing element with a duty which requires continuous operation of not more than five openings per minute. lass 8 s L and S lighting contactors are rated for resistance heating loads. e When discharged, a capacitor has essentially zero impedance. For repetitive switching by a contactor, sufficient impedance should be connected in series to limit inrush current to not more than 6 times the contactor rated continuous current. In many installations, the impedance of connecting conductors may be sufficient for this purpose. When switching to connect additional banks, the banks already on the line may be charged and can supply additional available short-circuit current which should be considered when selecting the impedance to limit the current. 7-/ 0 0 0 0 0 0 7 0 0 0 0 00 00 8 8 8 8 8 8 7 7 7 7 7 7 6 6 4 4 4 4 4 4 70 70 70 70 70 8 8 8 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 4 4 0 0 0 0 0 6. 6. 0 8..4 7 8 4 4 7 4 6 68 86 4 86.7 7 8 4 4 0.6..4.0..4 4. 6.. 4. 8..0 4. 8. 6 0 4 7 4 7 4 68 4 8.8. 4...6 4. 8..0 77 The ratings for capacitor switching above assume the following maximum available fault currents: 00 :,000 RMS Sym. 4 :,000 RMS Sym. 6: 8,000 RMS Sym. 7: 0,000 RMS Sym. Note: If available fault current is greater than these values, connect sufficient impedance in series as noted in the previous paragraph. f For 6 & 7, the operation rate is as follows: operation rate is operations per minute maximum; Jogging or Plugging Duty operation rate is operations per minute for a maximum of three minutes. The motor ratings in Table 6. are standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in the Table 6.. s having code letters occurring later in the alphabet may require a larger controller. onsult Schneider Electric at (-888-778-7). Table 6.: 0 0 0 0 7 0 0 0 00 80 6 Rating -/ 7-/ and above 6. 7. 4 8 4 8 0 4 4 7 8 4 88 4 0. 0.6.. 0.6....0. 4...0 4. 8. 6.8 4 7 4 7 4 7 4 68 0..0..6.8. 4....6 7. 8. 6. 7.0 4 8 0 4 4 4 7 8 6 0 7 67 80 0 80 0 0 Maximum llowable ode Letter L K 6 /DEFINITE PURPOSE TYPE 0 Schneider Electric 6-
Full ontactors and Starters Style pproximate Dimensions Table 6.: Dimensions for lass 80 Open of Poles Fig. DimensionsInches (Refer to ppropriate Figure) B D E F I lass 80, 86 / Refer to atalog 80T70 IN IN IN IN IN IN IN IN IN (lb) 00 SO -7/ 4-/ 4-7/ -/8 -/8 7/ -/6 4 0 SBO -7/ 4-/ 4-7/ -/8 -/8 7/ -/6 4 SO 4 4-/4 4-/ 4-7/ -/8 -/8 7/ -/6 4-/ SDO SEO 4 SFO 4-/6 -/8 4-/6 -/ -/ 7/ 4-/ 7/ -/6 6-/4 4 -/8 -/8 4-/6 -/ -/ 7/ 4-/ 7/ -/6 8-/4 -/ 7-/ 6-/ -7/8-7/ /6 6-/ -/4 4-/4 4 4 -/4 7-7/8 6-/ -/6 -/6 /6 7 4-7/ -/6 6 8-/6 6-/ -/6 -/6 /6 7 -/ -/6 8 4 -/4 8-/6 6-/ -/6 -/6 /6 7 4-7/ -/6 SO 8-/ -/6 8-/4 -/4 -/6 /8 -/8 4-/4 7-/4 4 6 SO -/64 8-/6-7/ 7-/ -/6 8-/6 4-/4 7-/4 80 7 SJO -/64 7-/4-7/8-7/ 7-/ 7-7/ -/8 4-/4 7-/4 Table 6.4: Dimensions for 86 Open 00, 0,, P 0, SO SO SBO SO SDO SEO 4 SFO of Poles Fig. DimensionsInches (Refer to ppropriate Figure) B D E F I IN IN IN IN IN IN IN IN IN (lb) -/ 6-4/64 4-7/ / -/64 /64 6-/4 -/ 4 4-7/ 6-4/64 4-7/ / -/ /64 6-/4 -/ -/ 4-/6 7-/6 4-/6 / -/ /64 7-/ 4-/6 7-/4 4 -/8 7-/6 4-/6 / -/ /64 7-/ 4-/6 -/4 -/ -/ 6-/ 7/8 -/4 -/ /6 -/6 -/4 7 4 -/4 -/8 6-/ -/6 -/4 -/6 /6 -/6 -/4 6-7/8 6-/ -/6 -/4 -/6 /6 -/6 -/4 4 -/4-7/8 6-/ -/6 -/4 -/ /6 -/6 -/4 SO 8-/6 7-/6 8-/4 4-/4 7-/4 -/ /8 6-/8 6 6 6 SO -/ 8-/6 4-/4 7-/4 -/ -/6 8-/6 8-/6 8 7 SJO -/ 7-/4-7/8 4-/4 7-/4 -/ 7-7/ -/8 Table 6.: Dimensions for 00 0 S SB S of Poles ll ll ll Fig. B 80 86 DimensionsInches D E F I J K L 6 -/ -/6 7/8 8-/8 /6 4-/8 SD ll 7-/6 -/6 6-/ 6-/6 -/ -/ -/ -/ -/8 -/4 -/ -/8 SE ll -7/6 -/6 8 8-/8-7/ 8-/4-7/ -7/ 8-/8 7-/4-7/ 8-/8 4 SF ll -/4 -/ 8-/ -/4 -/4 -/6-7/6 7/6 S ll 7-7/ 44-7/ -/6 -/6 -/8 -/8 -/8 /6 6 S ll 4 6-/4 0-7/ -/8 -/8 64-/ -/6 -/ 7 SJ ll 4 4-/ -/ -/ Floor Mounting Wt Wt D E I RESET D E F F B B Figure lass 80 D K L K E RESET I B E Figure lass 86 F B Figure Pilot Light I J () losing Plates F 6 Figure 4 /DEFINITE PURPOSE TYPE E RESET (4) I Dia. Mtg. oles B D F Figure 6-4 0 Schneider Electric