Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Similar documents
System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Manual motor starters Overview and benefits

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Mini contactors B6, BC6 with 3 pole

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF65 and TF96

A real all-rounder Flexible control of both direct and alternating currents The innovative S 200 M UC

Manual motor starter magnetic only MO325

Manual motor starter MS116

Selective main circuit breakers S 750 series Technical Data

Manual motor starter MS132

Manual motor starter MS132

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Mini Contactors Applications and Segments

Manual motor starter MS132

Manual motor starter MS116

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Miniature Circuit Breakers

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

ABB i-bus KNX DG/S x DALI-Gateway Basic

Thermal Overload Relays

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Short form catalogue Motor protection and control Manual motor starters

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Miniature circuit-breaker (MCB) SH200M Series

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Panorama. Contactors Motor protection Accessories

Selection Guide Motor Control Device Solutions

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ABB central inverters PVS to 2091 kva

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

New System pro M compact All that you need. 2CSC004011B0201

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Low Voltage Systems MNS and MNS is PowerCenter

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

TwinLine The new system of wall-mounting and floor-standing cabinets

TriLine PowerModules Overview with Planing Examples

US CATALOG. ProLine Panelboard and breakers

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Voltage limiting device HVL

Surge arrester POLIM-H.. ND

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Voltage limiting device HVL

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

PRODUCT BROCHURE. Steel City solid brass and aluminum floor box covers

New Dimension in Motor Protection Manual Motor Starter MS116

Data Sheet Definite Purpose Contactors Ex9CK Series

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

TECHNICAL CATALOG. ReliaGear SafeT interiors OEM power distribution interiors for panelboards and switchboards

Surge arrester POLIM-C.. HD

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Surge arrester POLIM-H..SD

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Data Sheet Manual Motor Starter Ex9S32 Series

abb.ch ABB Switzerland Ltd. Low Voltage Products Fulachstrasse 150 CH-8201 Schaffhausen Telefon +41 (0) Telefax +41 (0)

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

Data Sheet Manual Motor Starter Ex9S32 Series

FICHA TÉCNICA DE PRODUTO

Data Sheet Manual Motor Starters Ex9SN Series

ZX-Family Gas-insulated medium voltage switchgear

and other modular devices for low voltage installation

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

Emergency stops Award winning design

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

PQstorI One stop solution for energy storage and power quality

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Miniature Circuit Breaker UL / CSA Range

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

EMPAC Metal enclosed capacitor bank for wind applications

US CATALOG. Miniature circuit breakers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Traction systems for Light Rail Vehicles Selected references

Series L9 UL489 Miniature Circuit Breakers

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

Short-circuit current limiter S800-SCL-SR

Transcription:

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

The next generation MCB for UL/CSA applications within the proven System pro M compact range The SU 200 M miniature circuit breaker is ABB s solution for UL489 protection in branch circuits for voltages up to 480Y/277VAC, and 96VDC. This circuit breaker is an all-around device for universal use in AC and DC applications in North American and global markets with approvals according to UL, CSA, and IEC. Furthermore, the SU 200 M MCB is fully compatible with existing UL489 System pro M compact accessories. A range designed to ensure efficiency and protection For more than 120 years, based on the mindset of Hugo Stotz, ABB MCBs have an innovative history. Today, we offer MCB solutions for numerous applications to meet the needs of the most demanding customer. Performance in action The SU 200 M offers outstanding electrical and mechanical performance: Rated breaking capacity 10 ka acc. UL489 / CSA 22.2 No. 5 and 15kA acc. IEC / EN 60947-2 Certified up to In = 40 A at 480 Y / 277 V AC acc. to UL 489 / CSA 22.2 No.5 40 C reference temperature acc. to UL and CSA Clear contact position indication in red / green ( real CPI ) AC and DC at your command Inventory planning and project engineering has now been simplified with the SU 200 M. Having both AC and DC ratings allows a reduction in both inventory and product types for your project. 1 2 Easy identification Identification of the product can be found directly in the product part numbering system on the face of the device. Points such as number of poles, trip curve, and amperage can all be found in the device designation. This allows quick and intuitive identification of the circuit breaker. 6 1 New, patented twin terminals with captive screws: highest comfort, safety and flexibility 2 New, patented housing design: environmentally friendly and designed for maximum performance 3 3 marking Laser printing: scratch and solvent resistant 5 4 Real contact position indication, directly connected to the moving contact for greater safety and contact state identification 4 2CDC021004S0014 5 Immediate system availability after fault by simply switching on the MCB, even by unskilled personnel 6 Easy product coding easy identification: basic technical information already integrated in the name. Further information as well as a barcode for easy identification laser-printed on the dome or on the side of the MCB 2 2CDC002182B0201

The details make the difference Contact position indication All System pro M compact MCBs are equipped with real contact position indication (CPI). This allows for quick identification of the MCBs state, ON or OFF, if maintenance is required. Working together, both the position of the toggle and the color of the CPI, clear indication of the MCBs contact position provides additional security and safety. If an event has occurred, the device always provides reliable information on its state. Approvals printed on the dome SU 200 M MCBs comply with UL489/ CSA 22.2 No. 5 and carry approvals for other relevant markets or segments that they may be used in. For ease of identification, certification markings are printed on the dome and side of the MCB. PATENTED Housing Design The SU 200 M range utilizes the latest halogen free thermoplastic, making it possible to recycle the whole MCB and reducing environmental pollution. Logout-Tagout device Since safety is always at the forefront, the new S 200-LOTO devices can be added for use in a Lockout-Tagout program. The S 200-LOTO device is available in single and multi-pole versions UL Vario busbar With the new SU 200 M circuit breaker comes the new UL Vario busbar. The Vario busbar can be cut to length based on the number of UL489 branch circuit breakers in your design. PATENTED IP 20 finger safe terminals IP 20 terminals are standard on the SU 200 M System pro M compact line. Equipped with cylinder lift twin terminals that accept 35 mm 2 and 10 mm 2 wires or busbars, multiple wiring solutions can be achieved. 2CDC002182B0201 5

Accessory Overview The System pro M compact SU 200 M is the first truly complete compact and modular circuit breaker for both North American and global markets. This proven system offers all of the essential accessories; shunt trips, and auxiliary, and signal contacts. In development of the SU 200 M range, the ability to use existing accessories was a key design requirement. Current accessories can be used with both current MCBs and the new SU 200 M MCB. Auxiliary contact S2C-H6RU 1 The switching position of the auxiliary contact is dependent upon the toggle position of the MCB (On/Off). Being coupled to the switching mechanism, the auxiliary contact is used to indicate the state of the MCB. Signal contact S2C-S6RU 2 In the event of an overload or short circuit, the signal contact will indicate that the MCB has tripped. When the MCB is operated manually, the signal contact will not provide an indication, as the signal contact is coupled to the trip mechanism of the MCB. The signal contact also allows for resetting of the signal contact independently of the MCB. Shunt Trip 3 When applying a voltage to the solenoid, this accessory allows remote opening of the device. Two different models are available for both AC and DC control voltages. Busbar Systems 4 Busbars are available for the SU 200 M MCB range. Utilizing the patented twin-terminal design, busbars can be connected even after the device has been installed. 1 2 3 4 2CDC021324F004 2CDC021322F004 2CDC021146F0005 2CDC0061007S0010 2CDC002182B0201 3

Accessory Overview SU 200 M H Auxiliary contact S2C-H6RU (change-over contact) S/H Signal contact S2C-S6RU ST Shunt trip S2C-A... For UL/CSA applications, only one side mount accessory per MCB is allowed. The number of electrical operations is limited to 4000 operations for the maximum combinations and the combinations including shunt trips. 2CDC092011F0014 2CDC002182B0201 4

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com ABB Inc. 8155 T & B BLVD Memphis, TN 38125 United States of America Phone: 901-252-5000 ABB Inc. Low Voltage Products 2117 32nd Avenue Lachine, QC, CANADA H8T 3J1 Phone: 514-420-3100 Fax: 514-420-3137 Toll Free: 1-800-567-0283 Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Copyright 2015 ABB All rights reserved Order number 2CDC002182B0201 (2/15-pdf) You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems