Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Similar documents
TYPE EK-EU SMOKE CONTROL DAMPER

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type Pneumatic actuators

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Multileaf damper with actuator

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Parts and characteristics

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

For installation into ductwork

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

CONSTANTFLOW Volume Flow Controllers

Type VSD35. Nominal length up to 1500 mm: one spigot

Type Pneumatic actuators

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Fire damper. Type FKA-3.8. GB/en. Installation and operating manual. according to Declaration of Performance. DoP / FKA-3.

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Motorized Fire Dampers

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Pressure relief dampers

Volume Flow Limiters Type VFL

Ventilation grilles for installation into walls, sills or rectangular

Air terminal devices

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers Type RN

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Air Displacement Vent Units

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Ceiling swirl diffusers with perforated face plate

Slot diffusers for ceiling installation

7/S5 FIRE DAMPER FD40. v 2.9 (en)

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Ceiling swirl diffusers

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

VARYCONTROL VAV Dual Duct Terminal Boxes

Ducted HEPA filter units for highly sensitive areas

series FSD-FLD Fire and smoke dampers UL Approval

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

MULTICOMPARTMENT SMOKE CONTROL DAMPERS DKISMA

Circular Fire Dampers

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Systemair Fire Dampers

Grilles Linear Grilles

Combustion gas damper EKO-JB

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Fire Dampers Catalogue

Fire/combustion gas damper EKO-JBG

Fire/combustion gas damper EKO-JBL

Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Transcription:

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of commercial kitchens. For the isolation of duct penetrations between fire compartments, available in 16 nominal sizes Nominal sizes from 250 225 to 1200 500 mm 100% free area ensures maximum safety No differential pressure, low sound power level Easy to clean Integration into the central BMS with TROXNETCOM Optional equipment and accessories Electric blade opening actuator, 230 V Control module

APPLICATION Application Fire dampers of Type KA-EU for shutting off extract air and exhaust air ducts of commercial kitchens, with general building inspectorate licence To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments Special characteristics General building inspectorate licence Z-41.3-692 Tested for fire resistance properties to DIN 4104-6 and EN 1366-2 100% free area Low differential pressure and sound power level Integration into the central BMS with TROXNETCOM Classification Fire resistance class K90to DIN 4102-6 Nominal sizes 250 225 to 1200 500 mm L: 595 880 mm (depending on the selected casing height) DESCRIPTION Variants With thermal release mechanism With thermal release mechanism and control module With electric blade opening actuator and control module Parts and characteristics Installation in horizontal or vertical ducts

Installation in horizontal ducts with the damper blade at the top and airflow in any direction 100% free area, hence low differential pressure Secure closure by means of gas struts even when there are deposits Release temperature 72 C Attachments Capillary tube sensor Construction features Rigid rectangular casing with installation subframe Connecting flanges with fixing holes on both sides, suitable for duct connection Scrapers on the damper blade to scrape off greasy deposits etc. Damper blade outside of the airflow Remote control with electric blade opening actuator Materials and surfaces Casing: Galvanised sheet steel Stainless steel 1.4301 Damper blade: Special insulation material faced with stainless steel Other components: Damper blade shafts made of galvanised steel or stainless steel Standards and guidelines EN 1366-2:1999 Fire resistance tests for service installations Fire dampers DIN 4102-6, standard fire resistance test EN 1751 Ventilation for buildings Air terminal devices

VDI 2052 Ventilation equipment for kitchens Maintenance The functional reliability of the fire damper must be tested at least every six months; this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If two consecutive tests, one 6 months after the other, are successful, the next test can be conducted one year later. A functional test involves closing the damper blade and opening it again; with electric blade opening actuator this can be done via remote control Fire dampers must be included in the regular cleaning schedule of the ventilation system. For details on maintenance and inspection refer to the installation and operating manual TECHNICAL INFORMATION FUNCTION Construction for manual operation Functional description In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. When in the event of a fire the temperature rises to 72 C, a capillary tube sensor interrupts the power supply to the electromagnet, and the damper blade is released. While power is being supplied to the electromagnets, the fire damper can be opened with the blade opening lever. The release mechanism is accessible and can be tested from the outside. Construction with electric blade opening actuator Functional description In the event of a fire, fire dampers shut automatically to prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments. When in the event of a fire the temperature rises to 72 C, a capillary tube sensor interrupts the power supply to the electromagnet, and the damper blade is released. While power is being supplied to the electromagnets, the fire damper can be opened with the blade opening lever. The release mechanism is accessible and can be tested from the outside. Schematic illustration of KA-EU

1 Mounting plate 2 Spring tab 3 Limit switch for damper blade position CLOSED 4 Limit switch for damper blade position OPEN 5 Electromagnet 6 Damper blade with scraper 7 Casing 8 Gas strut 9 Fixing tab 10 Setting lever Schematic illustration of the KA-EU with electric blade opening actuator 1 Mounting plate 2 Spring tab 3 Limit switch for damper blade position CLOSED 4 Limit switch for damper blade position OPEN 5 Electromagnet 6 Damper blade with scraper

7 Casing 8 Gas strut 9 Fixing tab 10 Setting lever Electric blade opening actuator TECHNOLOGY Nominal sizes 250 225 1200 500 mm Volume flow rate range Up to 6000 l/s or 21600 m³/h Operating temperature 10 to 50 C Release temperature 72 C

QUICK SIZING Quick selection Duct dimensions B H in mm Volume flow rate V [l/s] Volume flow rate V [m³/h] Airflow velocity v A [m/s] Duct dimensions B H in mm 5 6 7 8 9 10 5 6 7 8 9 10 250 225 280 340 390 450 505 560 1008 1224 1404 1620 1818 2016 300 225 340 410 470 540 610 675 1224 1476 1692 1944 2196 2430 300 300 450 540 630 720 810 900 1620 1944 2268 2592 2916 3240 400 300 600 720 840 960 1080 1200 2160 2592 3024 3456 3888 4320 400 400 800 960 1120 1280 1440 1600 2880 3456 4032 4608 5184 5760 500 400 1000 1200 1400 1600 1800 2000 3600 4320 5040 5760 6480 7200 600 400 1200 1440 1680 1920 2160 2400 4320 5184 6048 6912 7776 8640 700 400 1400 1680 1960 2240 2520 2800 5040 6048 7056 8064 9072 10080 500 500 1250 1500 1750 2000 2250 2500 4500 5400 6300 7200 8100 9000 600 500 1500 1800 2100 2400 2700 3000 5400 6480 7560 8640 9720 10800 700 500 1750 2100 2450 2800 3150 3500 6300 7560 8820 10080 11340 12600 800 500 2000 2400 2800 3200 3600 4000 7200 8640 10080 11520 12960 14400 900 500 2250 2700 3150 3600 4050 4500 8100 9720 11340 12960 14580 16200 1000 500 2500 3000 3500 4000 4500 5000 9000 10800 12600 14400 16200 18000 1100 500 2750 3300 3850 4400 4950 5500 9900 11880 13860 15840 17820 19800 1200 500 3000 3600 4200 4800 5400 6000 10800 12960 15120 17280 19440 21600 SPECIFICATION TEXT Square or rectangular fire dampers for the isolation of extract air or exhaust air duct penetrations in commercial kitchens. With flanges for installation in horizontal or vertical ducts. Secure closure by means of gas struts even when there are deposits. Tested for fire resistance properties to DIN 4102-6 and EN 1366-2, fire resistance class K90; casing made of sheet steel, stainless steel as an option. Low-leakage damper blade made of special insulation material faced with stainless steel. Scrapers on the damper blade to scrape off greasy deposits etc. Thermal release mechanism 72 C. Two electric limit switches for capturing damper blade positions CLOSED and OPEN as well as for switching the fan off; electric blade opening actuator and control module as options. For mortar-based installation into solid walls and ceiling slabs, and into lightweight partition walls and fire walls with metal support structure and cladding on both sides. Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-12 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Special characteristics General building inspectorate licence Z-41.3-692 Tested for fire resistance properties to DIN 4104-6 and EN 1366-2 100% free area Low differential pressure and sound power level Integration into the central BMS with TROXNETCOM Materials and surfaces Casing: Galvanised sheet steel Stainless steel 1.4301 Damper blade: Special insulation material faced with stainless steel Other components: Damper blade shafts made of galvanised steel or stainless steel Technical data Nominal sizes: 250 225 1200 500 mm Volume flow rate range: up to 6000 l/s or 21600 m³/h Operating temperature: 10 to 50 C Release temperature: 72 C Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-12 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU ORDER CODE Type Country of destination KA-EU Fire damper for the extract air of commercial kitchens DE Germany Material No entry: galvanised casing 2 Stainless steel 1.4301 Other destination countries upon request Nominal size [mm] B H L Attachments Z00 Z01 Z02 Standard construction With control module With electric blade opening actuator and control module Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-12 TROX GmbH

Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-12 TROX GmbH