OPTIONS AUTOMATIC LUBRICATION SYSTEM

Similar documents
AUTOMATIC LUBRICATORS & LUBRICATION

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

HIGH PERFORMANCE LUBRICATION SYSTEM

Hydraulic pump HP-1. Type 1. Type 2

Perfect lubrication for a perfect system

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

HIGH PERFORMANCE LUBRICATION SYSTEM

modern lubrication technology LUBRiCUS modern lubrication technology

AUTOMATIC LUBRICATION

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

The powerful and flexible lubrication system

Section 5. Maintenance. Risk of Burns. Relieving Pressure. Important when Using Cleaning Agents. Maintenance 5-1

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems

LUBRICATION PUMP PMP CENTRAL LUBRICATION

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

Steering Gear: Service and Repair POWER STEERING GEAR BOX

PULSARLUBE The World leader of Automatic lubricators

Lubecore International Automated Lubrication System Inspection, Service & Repair - MLP/Spyder Pump MKI & MKI Rev-A

NV Direct Coupled Globe Valve Actuator

HP High-Performance Gear Units with <2' Adjustable Backlash

Operating Instructions

LUBRICATION PUMP PMP CENTRAL LUBRICATION

High Pressure Lubricators. Self-contained high pressure single or multipoint economical grease lubricator

16000SIII Automatic Grease System

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

STREAMLINER M 500 cc Instructions. User Operating Manual

Electric Pump EP-1. Electric pump EP-1 with steel reservoir and pump element PE-120 V with manometer:

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

Operating Instructions

MAINTENANCE MANUAL DI 16

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve)

Hydraulic Pump. General description. Hydraulic circuit diagram

perma Automatic Lubrication Systems

The powerful and flexible lubrication system

MAINTENANCE INSTRUCTIONS

Motor-driven pump unit GSJB

simalube Lubricators For Cost Effective Maintenance

Automatisch vetsmeersysteem Central grease lubrication system Automatisch Fettschmieranlage

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

Operation and service manual

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return

Mounting UNV Kits to NV Type Actuators

Angle seat valve with piston actuator VZXA-...-K

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

Automatic Pill Dispenser. (Model 3/07) Instructions

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

DelTorq Series 21 ACTUATOR

SKF Grease Filler Pumps LAGF series

NF-Series Operation Instructions

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

Progressive Central Lubrication Systems

Techcon Systems TS6500 CIM Automatic Techkit Mixer

1. Introduction. 2. Technical data. 2.1 Clamps

DelTech Controls L.L.C.

Operating Instructions. Angle Seat Control Valve. Type 7020

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

Long Chassis Hydraulic Service Jacks

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

Optional remote control available to connect to customer equipment or machinery. (eg. PLC, contactors, relays) Suitable for indoor/outdoor use.

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

1. General Description

Progressive distributor MX-F

AMIAD Automatic Filters

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

Product Description Sheet Posi-Link Volumetric Dispensing System See Item Numbers listed below North American Engineering Center

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

Quicklub. Pump Model 203 with Power Supply for VAC and Printed Circuit Board M08-M23. Owner Manual Technical Description

Axial Piston Fixed Pump A17FNO Series 10

MATEX LUBRICATOR INSTALLATION

5 Gear units, types of installation, lubricant quantities. 5.1 Standard fitting positions/ types of installation for Bauer geared motors

Frequently Asked Questions

MITYFLEX PERISTALTIC PUMPS

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

Injection Oilers, Micro Pumps

STH/Q SET UP INSTRUCTIONS

Centrifuge Operator / Service Manual

lubrication systems CME Electric pump for oil and soft grease volumetric

SECTION B1: MACHINE COMPONENTS

CLP - Cartridge Lube Pump

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

Pneumatic grease pump 50:1 and grease supply system

ELECTRIC GREASE AND OIL PUMPS ILC-MAX

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Starting up hydraulic systems

PLC Controlled High Performance Automatic Grease Lubricator

ETgage Model E Instructions

Agxcel GX12i Chemical Injection System

Active Controlled Cooling System

Injection oilers, micro pumps

PRODUCT OBSOLETED 1Q16

Micro-Injection System

Transcription:

OPTIONS AUTOMATIC LUBRICATION SYSTEM The central lubrication of the axes modules consists of a small lubricant dispenser with progressive distributor with several exits. It is responsible for the automatic lubrication of the toothed rack with the driving pinion and the prismatic and flat rail guidances of the Y-axis, the vertical Z-axis, and any further axes if applicable. Programming: The operating time is programmed for 12 months by means of the black plastic ring of the lubricant dispenser (volumetric displacement 120 cm 3 ). Setting up for operation / repairs: Pipes must be pre-filled (manually with a pump) with the appropriate type of oil before the system is set up for operation, but also after any exchange of pipes. Maintenance work: The exchange of the lubricant dispenser (expansion ring). For more detailed information, please see the chapter on Products from third-party companies MEMOLUB. Other suitable qualities of oil are: Degol GS 460 (Aral) BP Enersyn SG-XP 460 (BP) Pinnacle 460 (Texaco) Tivela Oil S 460 (Shell) Quality of oil Mobil Glygoyl 460 CAUTION Always use the prescribed original quality of oil for the central lubrication. In this case, do not use any other quality of oil with the same properties. In case you wish to use any other quality of oil with the same properties, the felts of the lubrication units must be replaced, in order to prevent any forbidden mixing of different qualities of oil.

Function Description of the Memolub Function Description of the Memolub This document describes the functional flow of the Memolubs and of the progressive distributor. It is meant as a help in software development. The Memolub system is connected as follows: Electrical connection Start motor (24VDC+) Feedback Cables Customers side Cables Customers side Plug pin Charging rate: 0.1-0.2A Cable length: 0.2-1.5m Feedback Sensor Mechanical connection Progressive distributor Vogel Sensor Vogel 177-300-097 Memolub Engineering CS, Engineering R+D 1

Function Description of the Memolub Description of the Functional Flow Description of the functional flow of the progressive distributor The lubricant flows from the main hose through the right snap ring groove of the piston and the reversing hose (on the right) to the left side of piston I and pushes it into its right-side end position. The lubricant displaced by piston I exits through the left reversing hose at outlet 6. After piston I was moved, the lubricant flows to the left side of piston II and pushes it to its right-side end position. The displaced lubricant exits through outlet 1. After piston II was moved, the lubricant flows to the left side of piston III and pushes it to its right-side end position. The displaced lubricant exits through outlet 2 After piston III was moved, the lubricant flows to the right side of piston I and pushes it to its left-side end position. The displaced lubricant exits through outlet 3. The continuing process is described in the diagram. Engineering CS, Engineering R+D 2

Function Description of the Memolub Systems functions Software flow chart: Start lubrication Lubrication cycle completed* No * 1 Lubrication cycle: Lubricate (10sek) + Break (5min) Yes No Feedback Sensor Nein Cycle loop completed 5x Yes Yes Lubrication ok Error report: Lubrication tank empty Hose to progressive distributor defective Feed to Memolub failed Signal transmitter, distributor defective Notice: The Sensor reports a completed cycle of the progressive distributor by changing the pulse twice. The software has to react on the second change of pulse at the PLC-input. Engineering CS, Engineering R+D 3

Function Description of the Memolub Signal diagram The signal diagram for the motor (output) and the transducer (feedback) shows up as follows: 10sek Normal case Motor: Sensor: Start 5min 10min 15min 20min 25min 30min Fault Motor: Sensor: Start 5min 10min 15min 20min 25min 30min Engineering CS, Engineering R+D 4

AUTOMATIC LUBRICATORS & LUBRICATION

MEMOLUB HPS Lubricator Introduction Refillable autonomous and programmable lubricator for one or more points of lubrication Lubrication is an important part of the maintenance. The lubricator, the point of lubrication, the quality and the frequency are the main elements for an effective lubrication and are therefore also important for an optimal production. In modern factories the points of lubrication are lubricated through a centralized lubrication system. These systems are effective if they are well maintained, regulated and checked. The rest is mainly lubricated manually or with small independent low pressure lubrication systems. MEMOLUB HPS is a high-pressure (25 Bar) and precise electromechanical lubricator for central and autonomous lubrication. It operates autonomously, contains an oil or lubricant bellows and is battery driven. Using a progressive distributor makes it possible to lubricate several points at the same time. It can be (if possible) mounted directly to the point of lubrication or pressed through lines on to the point of lubrication. Specifications Dimensions and Capacity Standard Mega Giga 115 x 101 mm 147 x 101 mm 228 x 101 mm 120 cm 3 (ml) 240 cm 3 (ml) 480 cm 3 (ml) Electronic Controls Quartz Timer, Microprocessor Stop, Start Immediate Lubricants Oils and Greases (to NLGI #2) Feed HPS= 3 Batteries 4,5 V Alkaline EPS= 5 VDC 12 VDC cable 0.4m 24 VDC SPS= 12 VDC 24 VDC cable 0.4m Temperature Range From 15 C to + 50 C Feed pressure 25 bar (piston pump) Point of lubrication 1 to max. 8 out lines (with progressive distributors) Remote installation Monopoint Up to 10 m line length Remote installation Multipoint 4m line length per point of lubrication Installation Thread ¼ inch R Protection class IP66 Max. feed volume 0.635 cm 3 (ml) Min. feed volume 0.100 cm 3 (ml) with metering discs P.S. In case of extended usage at temperatures below 5 C, it is important to check the battery status regularly by activating the control function.

MEMOLUB HPS Lubricator Program settings MEMO Standard program settings using coloured plastic rings The electronic lubricant regulation is done with 3 coloured (red, white, black) plastic rings, which inserted in a black plastic support, activate the electronic contacts of the frequency selector through the pressed pins. With a single ring inserted, the time related feed volume increases from the outside inwards. With all 3 rings inserted, the maximum feed volume is reached. Depending on the combination of the rings, the desired time related feed volume can be set or the rate of dispension of the reservoir of lubricant in the bellows can be determined. Rate of dispension as a function of the combination of the rings (red, white, black) Inserted rings Frequency (hours) Duration 120 cm³ (ml) Duration 240 cm³ (ml) Duration 480 cm³ (ml) Black 48 h 12 months 2 Jahre* 3 *days White 24 h 6 months 12 months 18 months Red 12 h 3 months 6 months 9 months Black + white 16 h 4 months 8 months 12 months Black + rot 6 h - 3 months 6 months White + red 2 h - 1 month 2 months Black + white + red 1 h - 15 days 1 month * External power supply required (5 volts)

MEMOLUB HPS Lubricator Finer programming settings using the black metering disc For an even finer setting of the time related feed volume, insert up to 5 small black metering discs and a open steel ring in the cylinder of the MEMO. Rate of dispension with additional metering discs Inserted ring Measuring out disc Frequency (hours) Duration/Standard 120 cm³ (ml) Duration/Mega 240 cm³ (ml) Black 5** 48 h 18 months 3 years * Black 0 48 h 12 months 2 years * White 5** 24 h 9 months 18 months White 0 24 h 6 months 12 months Red 5** 12 h - 9 months Black + white 0 16 h 4 months 8 months Red 0 12 h 3 months 6 months Black + rot 0 6 h - 3 months White + red 0 2 h - 1 month Black + white + red 0 1 h - 15 days * external feed required ** metering disc incl. open metering disc Warranty For mechanical and electronic components a warranty period of 12 months is extended provided that the housing of the control unit (red) was not opened and the transparent bell is not damaged. The warranty is limited to the replacement of the lubricator. The operator is responsible to check the device for function. For more information on the MEMOLUB please visit the website.

MEMOLUB HPS Installation Instruction Installation Instruction Lubricator Battery 1. Program the volume of lubricant output by inserting the stroke-limiting washers. 2. Install the Power-Through Memo fitting, either direct or remote mounted. 3. Screw the MEMOLUB HPS on the Power-Through MEMO fitting. Installation Instruction Lubricator 24VDC-PLC 1. Program the volume of lubricant output by inserting the stroke-limiting washers. 2. Install the Power-Through Memo fitting, either direct or remote mounted. 3. Screw the MEMOLUB HPS on the Power-Through MEMO fitting. 4. The MEMOLUB 24VDC-PLC must be connected to a PLC for its power supply. The PLC determines the frequency of output cycles. (PLC Not Included) General Information Maintenance Avoid operations with an empty cartridge. To restore the pump's suction function, use a grease gun without a grease nipple. 1 or 2 strokes are sufficient. Function checks during operations If the MEMOLUB is rotated by a half turn outwards and then inwards again, a completely automatic lubrication cycle is started 5 seconds after the inward rotation. Regularly perform checks. Stop / Start 5 seconds after screwing it into the lubrication point, the first lubrication cycle is started. The MEMOLUB can be stopped and started again at any time (machine standstill, weekends, holidays, etc.). Just rotate the MEMOLUB by 3 rotations outwards and inwards again. After the inward rotation, the MEMOLUB carries out a self-test and is operational immediately afterwards. Caution! In progressive distributors and /or long lines that are filled with lubricants, a so-called relaxation may occur within these systems. The Memo is then filled with lubricant. While screwing the MEMOLUBS onto the Memo, pressures of over 100 bar may be generated which may damage the MOLUB. Use a so-called "SAFETY-MEMO. On progressive distributors and / or on long lines Line lengths for central lubrication The length of the line depends on the type of lubricant to be transported and on the ambient temperature. With a multi-purpose lubricant and temperatures exceeding 100 C the following line lengths are used. At 4mm inner diameter max. 6m for single points of lubrication, max. 8x2,5 m for progressive distributors.

MEMOLUB HPS Battery-Controlled Change of Battery and Lubricant Cartridge 1 2 1. Unscrew the MEMO- LUB HPS (1) from the Power-Through MEMO (2) fitting. The MEMO stays at position. 2. To open, place the lubricator upright on flat surface. Press firmly and turn locking ring counterclockwise while holding the ribbed surface. 3. Remove the cartridge and batteries and dispose of them in an environmentally friendly way. Insert a new set of batteries according to the instructions on the red housing. 4. Remove the paper, diskshaped label from the replacement cartridge and fill in the "Start Date" and "Change Date". 5. Carefully squeeze air out of the cartridge until grease begins to emerge from the outlet. Grease Cartridges Only 6. Place the cartridge on the inlet of the red housing. 5. Hold the cartridge with the outlet facing up. Carefully remove the cartridge plug. Turn the red housing over and gently place it on the outlet of the cartridge. Oil Cartridges Only 6. While holding the cartridge and red housing together, flip the assembly over and hold the cartridge in place. 7. Place the clear housing assembly over the lubricant cartridge and red housing. 8. Holding the locking ring by its ribbed surface, turn it clockwise until it clicks into the locked position. 9. Simulate a function test manually. Press the sensor pen against the bottom of the housing for approx. 5 sec. 10. Screw the MEMOLUB HPS lubricator onto the Power-Through MEMO. Danger and safety instructions Note: If necessary, prime the MEMOLUB HPS with a hand grease gun (grease cartridges only). Warning: Lower red housing contains a loaded spring. Do not open. Attention! During the manual function test, lubricant may leak out. Point the MEMOLUB downwards and away from people. L éq. < 70Db. Use MEMOLUBS only for the lubrication of machines Use only factory pre-filled cartridges and battery packs with MEMOLUB lubricator. Third party battery cells could destroy the electronics.

MEMOLUB HPS 24VDC-PLC-Controlled Change of Lubricant Cartridge Danger and safety instructions 1 Warning: Lower red housing contains a loaded spring. Do not open. L éq. < 70Db. Use MEMOLUBS only for the lubrication of machines Use only factory pre-filled cartridges with MEMOLUB lubricator. 1. Unscrew the MEMO- LUB HPS (1) from the Power-Through MEMO (2) fitting. The MEMO stays at position. 2 2. To open, place the lubricator upright on flat surface. Press firmly and turn locking ring counter-clockwise while holding the ribbed surface. 3. Remove the paper, diskshaped label from the replacement cartridge and fill in the "Start Date" and "Change Date". 4. Carefully squeeze air out of the cartridge until grease begins to emerge from the outlet. 5. Place the cartridge on the inlet of the red housing. 4. Hold the cartridge with the outlet facing up. Carefully remove the cartridge plug. Turn the red housing over and gently place it on the outlet of the cartridge. 5. While holding the cartridge and red housing together, flip the assembly over and hold the cartridge in place. Grease Cartridges Only Oil Cartridges Only 6. Place the clear housing assembly over the lubricant cartridge and red housing. 7. Holding the locking ring by its ribbed surface, turn it clockwise until it clicks into the locked position. 8. Screw the MEMOLUB HPS lubricator onto the Power-Through MEMO. Note: If necessary, prime the MEMOLUB HPS with a hand grease gun (grease cartridges only).