D SERIES TECHNICAL DATA INFORMATION PACKET

Similar documents
D SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

Power Flame Incorporated

D/LND SERIES. Installation, Operation, and Service Manual

XL/LNXL SERIES. Installation, Operation, and Service Manual for Vertical Configuration

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

IMMERSION FIRED HOT WATER BOILER

M/SERIES. Installation, Operation, Service, and Parts Manual

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP

COMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners

Model CBEX Elite HP

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Model HDS and HDSX Burner

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

Eclipse Vortometric Burners Series HI

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Doing more for clean environment and energy saving

MULTIFIRE. High temperature dual fuel burner

Model CBLE Boilers HP

Hamilton 3VO Submittal

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

BOILER RATINGS. Net Ratings Oil Gas

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

ICEMINI & Vertical MTI Units

Model 4WI HP 4 Pass Wet-Back with Integral Burner

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

1466 SERIES COLD AIR GAS/OIL BURNER

CBLE HP. Boiler Book 05/2017

CLEAVER-BROOKS. ProFire Burner. Operation, Maintenance, and Parts Manual. Addendum to:

Manual C888 Rev.709 Copyright Power Flame Incorporated 2004 Printed U.S.A.

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

Date: Project #: Engineer: Prepared By: Bid Date:

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

KINEMAX. Medium velocity gas or oil burners

1470 SERIES HOT AIR GAS BURNER

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

UPFLOW/ HORIZONTAL GAS FURNACE

DATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

Economite RE Series. Power Gas Burners. MADE in the USA

1070 SERIES ULTRA LOW NO X

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

VALUPAK. Packaged gas burners

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

XP80 / XV80 Highboy Vertical THV1M087A936,V3,SA THV1M087A948,V5,SA

Design and Application Details

SUMG-100. Burner Package & Components

Table of Contents GF801U Series

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

Replacement parts. Table 6. Item Description Part no. A Regular front section

Rheem Classic Series Upflow/Horizontal Gas Furnace

XIII. Repair Parts 106

DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B


RAYPAK ILLUSTRATED PARTS LIST

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Troubleshooting Guide

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

7. SERVICING AND COMPONENT ADJUSTMENTS

Start-up Instructions

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

TECHNICAL SERVICE BULLETIN

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Converting to Natural Gas for MATs Compliance August 7, 2014

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

A.O. Smith Water Heater Parts Fulfillment 125 Southeast Parkway, Franklin, TN

A.O. SMITH WATER PRODUCTS CO., INC W. 115TH STREET ALSIP, ILLINOIS Phone: Fax: Website:

HELICAL COIL HEATERS REPLACEMENT PARTS HEATEC AN ASTEC COMPANY HC AND HCS SERIES

Eclipse Single-Ended Radiant Tube Burners

KG7T (E and N Series)

Power Flame Incorporated

FG7T (E and N Series)

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

779PAC TO 786PAC PROPORTIONING COMBINATION BURNERS

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

TriOx Triple Air Staged Ultra Low NOx Burner

HEAVY DUTY RANGES GRIDDLE TOP

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

1032 SERIES LARGE CAPACITY DUAL FUEL OIL/GAS, AMBIENT OR PREHEATED AIR BURNER

Transcription:

D SERIES TECHNICAL DATA INFORMATION PACKET

Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM, DMG Technical Data Sheet...6 Ratings Table...7 Dimension Table...8 D Series Uncontrolled Emissions DE, DEG Technical Data Sheet...9 Ratings Table...10 Dimension Table...11 D Series <30 PPM Low NOx LNDG, LNDLG Technical Data Sheet...12 Ratings Table...13 Dimension Table... 14-15

Technical Data Sheet Uncontrolled Emissions Configuration (DG, DL, DLG) 4.2-42.0 MM BTU/H NG; 30-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 3450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: butterfly rate control valve, high/low gas pressure switches, two gas shutoff cocks, main gas regulator, shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: Natural gas (DG), #2 oil - air atomized (DL) or Combination gas/ #2 oil - air atomized (DLG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (DLG). Series Features Optional Feature Flame Safeguard UV Scanner Mode of Operation Full Modulation Firing Auto-Manual Firing Rate Control 1 1 1 1 1 1 Ignition Gas/Electric Pilot and Ignition Transformer #2 Oil Pilot (DL, DLG) Oil Components 3-Way Solenoid Valve 2-Way Solenoid Valve 3-Way Motorized POC Valve 2-Way Motorized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Integral Oil/Air System Burner Mounted Oil Metering System Separately Mounted Air Compressor Module Gas Components Motorized Valve w/o POC & Solenoid Valve Motorized Valve w/ POC & Solenoid Valve Motorized Valve w/ POC (2) Motorized w/ POC & Motorized w/o POC Normally Open Vent Valve 1 Standard for full modulation; optional on select parallel positioning systems Note: A separate oil circulating pump set is required for all DL and DLG burners. The burner mounted unit is an oil input metering device only. D-42 D-54 to D-105 D-145 D-175 to D-210 D-252 to D-315 D-336 to D-420 3

Standard Ratings Sheet DG - DL - DLG: Gas, #2 Oil, Gas/Oil Configuration Gas Input MBH #2 Oil Input GPH BHP @ 80% Eff. Blower Motor HP "S" 1 Blower Motor HP "P" 2 Integral Oil/Air System Separate Compressor Module Oil Metering System Standard Gas Train Pipe Size (in.) Gas Pressure Required ("w.c.) Model No. & Frame Size D-42-1 4,200 30 100 3 3 1 - - 2 9.2 D-54-1 5,400 39 129 3 5 1 - - 2 15.3 D-63-1 6,550 47 156 5 5 1 - - 2 21.6 D-84-2 8,400 60 200 5 7 1/2 1 - - 2 1/2 18.0 D-105-2 10,500 75 250 7 1/2 10 2 - - 3 16.0 208 / 230 / 460 / 3 D-145-3 15,000 107 357 15 15 2 - - 3 2 PSI D-175-4 17,500 125 417 20 20-5 1/2 3 5 PSI D-210-5 21,000 150 500 20 25-5 3/4 3 5 PSI D-252-6 25,200 180 600 25 30-7 1/2 3/4 3 5 PSI 230 / 460 / 3 D-300-6 30,000 215 714 40 40-7 1/2 3/4 3 10 PSI D-315-6 31,500 225 750-60 - 7 1/2 3/4 3 10 PSI D-336-7 33,600 240 800-60 - 7 1/2 3/4 3 10 PSI 460 / 3 D-378-8 37,800 270 900-75 - 15 1 4 10 PSI D-420-8 42,000 300 1,000-75 - 15 1 4 10 PSI 1 Use model "S" up to 1.5" w.c. furnace pressure 2 Use model "P" up to 4.0" w.c. furnace pressure Consult the factory for higher furnace pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft., 0.60 gravity, 0" w.c. furnace pressure and the aforementioned conditions. For total pressure at manifold, add furnace pressure. Oil input based on 140,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 4

Standard Dimension Sheet DG - DL - DLG: Gas, #2 Oil, Gas/Oil Configuration Burner Frame Size & Model Number Boiler HP Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Size 7 Size 8 DIM 42-63 84 105 145 175 210 252-300 315 336 378-420 Length in inches Overall length E 45 3/4 44 5/8 45 5/8 56 7/8 60 64 3/4 66 3/8 69 3/8 68 1/2 73 7/8 Width in inches Center line to right side I 21 5/8 23 7/8 23 7/8 24 3/4 25 1/4 32 3/8 32 3/8 32 3/8 32 3/8 36 7/8 Center line to left side J 17 7/8 17 5/8 17 5/8 21 22 23 3/4 23 3/4 23 3/4 23 3/4 28 Height in inches Center line to top F 13 15 15 15 15 21 21 21 21 23 Center line to bottom G 23 3/4 25 3/8 25 3/8 30 1/8 31 7/8 35 7/8 37 3/8 37 3/8 38 7/8 39 7/8 Dry oven dimensions in inches Diameter of dry oven A 15 7/8 19 19 22 27 1/2 27 1/2 31 1/2 31 1/2 34 5/8 34 5/8 Depth of dry oven C 9 10 10 12 12 12 15 15 18 18 Mounting flange dimensions in inches Diameter B 22 24 24 27 32 1/2 32 1/2 37 37 40 42 Flange to hinge D 18 18 18 21 1/2 21 1/2 21 1/2 22 22 22 24 Diameter of bolt circle L 20 1/2 22 22 25 30 1/2 30 1/2 35 35 38 40 Number of mounting holes K 8 12 12 12 12 12 12 12 12 12 Hinge swing dimensions in inches Center line to outer hinge clearance M 32 3/4 35 3/8 36 3/8 45 50 5/8 54 3/8 56 7/8 59 7/8 60 5/8 69 1/8 Hinge swing radius N 27 3/8 29 30 37 3/8 41 1/4 46 47 1/2 50 1/4 50 1/4 55 5/8 Oil inlet dimensions in inches Diameter of oil inlet Q 3/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Mounting flange to oil inlet P 17 7/8 27 27 30 1/2 30 1/2 30 1/2 31 31 30 7/5 33 3/4 Gas inlet dimensions in inches Diameter of gas inlet R 2 2 1/2 2 1/2 3 3 3 4 4 4 4 Mounting flange to gas inlet H 3 5/8 3 5/8 3 5/8 4 1/8 4 1/8 4 1/8 4 5/8 4 5/8 4 5/8 3 7/8 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 5

Technical Data Sheet Uncontrolled Emissions Configuration (DM, DMG) 4.2-42.0 MM BTU/H NG; 29-290 GPH #2-5 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 3450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: butterfly rate control valve, high/low gas pressure switches, two gas shutoff cocks, main gas regulator, shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: #2-5 oil - Air atomized (DM) or Combination natural gas/ #2-5 oil - air atomized (DMG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (DMG). Series Features Optional Feature Flame Safeguard D-42 to D-105 D-145 D-175 D-210 D-252 to D-315 D-336 to D-420 IR Scanner Mode of Operation Full Modulation Firing 6 Auto-Manual Firing Rate Control 1 1 1 1 1 1 Ignition Gas/Electric Pilot and Ignition Transformer #2 Oil Pilot Oil Components 3-Way Oil Solenoid Valve 2-Way Oil Solenoid Valve 3-Way Motorized POC Valve 2-Way Motorized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Integral Oil/Air System Burner Mounted Oil Metering System Separately Mounted Air Compressor Module Nozzle Line Heater with Cold Oil Lockout Gas Components Motorized Valve w/o POC & Solenoid Valve Motorized Valve w/ POC & Solenoid Valve Motorized Valve w/ POC (2) Motorized w/ POC & Motorized w/o POC Normally Open Vent Valve 1 Standard for full modulation; optional on select parallel positioning systems Note: A separate oil circulating pump set is required for all DM and DMG burners. The burner mounted unit is an oil input metering device only.

Standard Ratings Sheet DM - DMG: #2-5 Oil, Gas/Oil Configuration Gas Input MBH #2-5 Oil Input GPH BHP @ 80% Eff. Blower Motor HP "S" 1 Blower Motor HP "P" 2 Integral Oil/Air System Separate Compressor Module Oil Metering System Standard Gas Train Pipe Size (in.) Gas Pressure Required ("w.c.) 3 Nozzle Line Heater (kw) Model No. & Frame Size D-42-1 4,200 29 100 3 3 1 - - 2 9.2 3 D-54-1 5,400 38 129 3 5 1 - - 2 15.3 3 D-63-1 6,550 45 156 5 5 2 - - 2 21.6 3 D-84-2 8,400 58 200 5 7 1/2 2 - - 2 1/2 18.0 5 D-105-2 10,500 73 250 7 1/2 10 2 - - 3 16.0 5 208 / 230 / 460 / 3 D-145-3 15,000 104 357 15 15 2 - - 3 2 PSI 5 D-175-4 17,500 121 417 20 20-5 1/2 3 5 PSI 5 D-210-5 21,000 145 500 20 25-5 3/4 3 5 PSI 7 D-252-6 25,200 174 600 25 30-7 1/2 3/4 3 5 PSI 10 230 / 460 / 3 D-300-6 30,000 207 714 40 40-7 1/2 3/4 3 10 PSI 10 D-315-6 31,500 217 750-60 - 7 1/2 3/4 3 10 PSI 10 D-336-7 33,600 232 800-60 - 7 1/2 3/4 3 10 PSI 10 460 / 3 D-378-8 37,800 261 900-75 - 15 1 4 10 PSI 10 D-420-8 42,000 290 1,000-75 - 15 1 4 10 PSI 10 1 Use model "S" up to 1.5" w.c. furnace pressure, consult the factory for higher pressures 2 Use model "P" up to 4.0" w.c. furnace pressure, consult the factory for higher pressures 3 Standard gas pressures only, consult the factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft., 0.60 gravity, 0" w.c. furnace pressure and the aforementioned conditions. For total pressure at manifold, add furnace pressure. Oil input based on 145,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 7

Standard Dimension Sheet DM - DMG: #2-5 Oil, Gas/Oil Configuration Combination Gas/Oil Combination Gas/Oil Models 42-145 Models 175-420 Burner Frame Size & Model Number Boiler HP Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Size 7 Size 8 DIM 42-63 84 105 145 175 210 252-300 315 336 378-420 Length in inches Overall length E 45 3/4 44 5/8 45 5/8 56 7/8 60 64 3/4 66 3/8 69 3/8 68 1/2 73 7/8 Width in inches Center line to right side I 21 5/8 23 7/8 23 7/8 24 3/4 25 1/4 32 3/8 32 3/8 32 3/8 32 3/8 36 7/8 Center line to left side J 17 7/8 17 5/8 17 5/8 21 22 23 3/4 23 3/4 23 3/4 23 3/4 28 Height in inches Center line to top F 13 15 15 15 15 21 21 21 21 23 Center line to bottom G 23 3/4 25 3/8 25 3/8 30 1/8 31 7/8 35 7/8 37 3/8 37 3/8 38 7/8 39 7/8 Dry oven dimensions in inches Diameter of dry oven A 15 7/8 19 19 22 27 1/2 27 1/2 31 1/2 31 1/2 34 5/8 34 5/8 Depth of dry oven C 9 10 10 12 12 12 15 15 18 18 Mounting flange dimensions in inches Diameter B 22 24 24 27 32 1/2 32 1/2 37 37 40 42 Flange to hinge D 18 18 18 21 1/2 21 1/2 21 1/2 22 22 22 24 Diameter of bolt circle L 20 1/2 22 22 25 30 1/2 30 1/2 35 35 38 40 Number of mounting holes K 8 12 12 12 12 12 12 12 12 12 Hinge swing dimensions in inches Center line to outer hinge clearance M 32 3/4 35 3/8 36 3/8 45 50 5/8 54 3/8 56 7/8 59 7/8 60 5/8 69 1/8 Hinge swing radius N 27 3/8 29 30 37 3/8 41 1/4 46 47 1/2 50 1/4 50 1/4 55 5/8 Oil inlet dimensions in inches Diameter of oil inlet Q 3/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Mounting flange to oil inlet P 17 7/8 27 27 30 1/2 30 1/2 30 1/2 31 31 30 7/8 33 3/4 Gas inlet dimensions in inches Diameter of gas inlet R 2 2 1/2 2 1/2 3 3 3 4 4 4 4 Mounting flange to gas inlet H 3 5/8 3 5/8 3 5/8 4 1/8 4 1/8 4 1/8 4 5/8 4 5/8 4 5/8 3 7/8 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 8

Technical Data Sheet Uncontrolled Emissions Configuration (DE, DEG) 4.2-42.0 MM BTU/H NG; 28-280 GPH #2-6 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 3450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: butterfly rate control valve, high/low gas pressure switches, two gas shutoff cocks, main gas regulator, shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: #6 oil - air atomized (DE) or Combination natural gas/ #6 oil - air atomized (DEG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (DEG). Series Features Optional Feature Flame Safeguard D-42 to D-105 D-145 D-175 D-210 D-252 to D-315 D-336 to D-420 IR Scanner Mode of Operation Full Modulation Firing Auto-Manual Firing Rate Control 1 1 1 1 1 1 Ignition Gas/Electric Pilot and Ignition Transformer #2 Oil Pilot Oil Components 3-Way Oil Solenoid Valve 2-Way Oil Solenoid Valve 3-Way Motorized POC Valve 2-Way Motorized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Oil Metering System Separately Mounted Air Compressor Module Nozzle Line Heater with Cold Oil Lockout Gas Components Motorized Valve w/o POC & Solenoid Valve Motorized Valve w/ POC & Solenoid Valve Motorized Valve w/ POC (2) Motorized w/ POC & Motorized w/o POC Normally Open Vent Valve 1 Standard for full modulation; optional on select parallel positioning systems Note: A separate oil circulating pump set is required for all DE and DEG burners. The burner mounted unit is an oil input metering device only. 9

Standard Ratings Sheet DE - DEG: #2-6 Oil, Gas/Oil Configuration Gas Input MBH #2-6 Oil Input GPH BHP @ 80% Eff. Blower Motor HP "S" 1 Blower Motor HP "P" 2 Separate Compressor Module 3 PH. Oil Metering System 3 PH. Standard Gas Train Pipe Size (in.) Gas Pressure Required ("w.c.) 3 Nozzle Line Heater (kw) Model No. & Frame Size D-42-1 4,200 28 100 3 3 3 1/2 2 9.2 3 D-54-1 5,400 36 129 3 5 3 1/2 2 15.3 3 D-63-1 6,550 44 156 5 5 3 1/2 2 21.6 3 D-84-2 8,400 56 200 5 7 1/2 3 1/2 2 1/2 18.0 5 D-105-2 10,500 70 250 7 1/2 10 3 1/2 3 16.0 5 208 / 230 / 460 / 3 D-145-3 15,000 100 357 15 15 3 1/2 3 2 PSI 5 D-175-4 17,500 114 417 20 20 5 1/2 3 5 PSI 5 D-210-5 21,000 140 500 20 25 5 3/4 3 5 PSI 7 D-252-6 25,200 168 600 25 30 7 1/2 3/4 3 5 PSI 10 230 / 460 / 3 D-300-6 30,000 200 714 40 40 7 1/2 3/4 3 10 PSI 10 D-315-6 31,500 210 750-60 7 1/2 3/4 3 10 PSI 10 D-336-7 33,600 224 800-60 7 1/2 3/4 3 10 PSI 10 460 / 3 D-378-8 37,800 252 900-75 15 1 4 10 PSI 10 D-420-8 42,000 280 1,000-75 15 1 4 10 PSI 10 1 Use model "S" up to 1.5" w.c. furnace pressure, consult the factory for higher pressures 2 Use model "P" up to 4.0" w.c. furnace pressure, consult the factory for higher pressures 3 Standard gas pressures only, consult the factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft., 0.60 gravity, 0" w.c. furnace pressure and the aforementioned conditions. For total pressure at manifold, add furnace pressure. Oil input based on 150,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 10

Standard Dimension Sheet DE - DEG: #2-6 Oil, Gas/Oil Configuration Burner Frame Size & Model Number Boiler HP Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 Size 7 Size 8 DIM 42-63 84 105 145 175 210 252-300 315 336 378-420 Length in inches Overall length E 45 3/4 44 5/8 45 5/8 56 7/8 60 64 3/4 66 3/8 69 3/8 68 1/2 73 7/8 Width in inches Center line to right side I 21 5/8 23 7/8 23 7/8 24 3/4 25 1/4 32 3/8 32 3/8 32 3/8 32 3/8 36 7/8 Center line to left side J 17 7/8 17 5/8 17 5/8 21 22 23 3/4 23 3/4 23 3/4 23 3/4 28 Height in inches Center line to top F 13 15 15 15 15 21 21 21 21 23 Center line to bottom G 23 3/4 25 3/8 25 3/8 30 1/8 31 7/8 35 7/8 37 3/8 37 3/8 38 7/8 39 7/8 Dry oven dimensions in inches Diameter of dry oven A 15 7/8 19 19 22 27 1/2 27 1/2 31 1/2 31 1/2 34 5/8 34 5/8 Depth of dry oven C 9 10 10 12 12 12 15 15 18 18 Mounting flange dimensions in inches Diameter B 22 24 24 27 32 1/2 32 1/2 37 37 40 42 Flange to hinge D 18 18 18 21 1/2 21 1/2 21 1/2 22 22 22 24 Diameter of bolt circle L 20 1/2 22 22 25 30 1/2 30 1/2 35 35 38 40 Number of mounting holes K 8 12 12 12 12 12 12 12 12 12 Hinge swing dimensions in inches Center line to outer hinge clearance M 32 3/4 35 3/8 36 3/8 45 50 5/8 54 3/8 56 7/8 59 7/8 60 5/8 69 1/8 Hinge swing radius N 27 3/8 29 30 37 3/8 41 1/4 46 47 1/2 50 1/4 50 1/4 55 5/8 Oil inlet dimensions in inches Diameter of oil inlet Q 3/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Mounting flange to oil inlet P 17 7/8 27 27 30 1/2 30 1/2 30 1/2 31 31 30 7/8 33 3/4 Gas inlet dimensions in inches Diameter of gas inlet R 2 2 1/2 2 1/2 3 3 3 4 4 4 4 Mounting flange to gas inlet H 3 5/8 3 5/8 3 5/5 4 1/8 4 1/8 4 1/8 4 5/8 4 5/8 4 5/8 3 7/8 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 11

Technical Data Sheet <30 PPM Low NOx Configuration (LNDG, LNDLG) 3.36-37.8 MM BTU/H NG; 24-270 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and FM for U.S. or Canadian units Standard equipment: 3450 RPM motor, panel signal lights (Power On, Main Fuel, Ignition, Flame Failure), FGR, dry oven and gasket, combustion air proving switch, high fire air proving switch, 120/1/60 control circuit, burner mounted panel, hinged blast tube with right-hand swing. Gas and gas/oil units only: butterfly rate control valve, high/low gas pressure switches, two gas shutoff cocks, main gas regulator, shipped loose gas train. Combustion Control System options: Parallel Positioning Combustion Control System with O 2 Trim and Variable Frequency Drive (VFD) Fuel options: Main Fuel: Natural gas (LNDG), or Combination gas/ #2 oil - air atomized (LNDLG). Igniter Fuel: Natural gas and/or propane. Fuel Changeover Switch: Combination gas/oil units only (LNDLG). Series Features Optional Feature Flame Safeguard LND-42 to LND-63 LND-84 to LND-105 LND-145 LND-175 LND-210 LND-252 to LND-420 UV Scanner Mode of Operation Full Modulation Firing 12 Auto-Manual Firing Rate Control 1 1 1 1 1 1 Ignition Gas/Electric Pilot and Ignition Transformer Oil Components Oil Solenoid Valve 3-Way Motorized POC Valve Atomizing Air Proving Switch Low Oil Pressure Switch Burner Mounted Integral Oil/Air System Burner Mounted Oil Metering System Separately Mounted Air Compressor Module Gas Components Motorized Valve w/o POC & Solenoid Valve Motorized Valve w/ POC & Solenoid Valve Motorized Valve w/ POC (2) Motorized w/ POC & Motorized w/o POC Normally Open Vent Valve 1 Standard for full modulation; optional on select parallel positioning systems Note: A separate oil circulating pump set is required for all LNDLG burners. The burner mounted unit is an oil input metering device only.

<30 PPM Low NOx Ratings Sheet LNDG - LNDLG: Gas, Gas/Oil Configuration Gas Input MBH #2 Oil Input GPH BHP @ 80% Eff. Blower Motor HP "S" Blower Motor HP "P" Integral Oil/Air System Separate Compressor Module Oil Metering System Standard Gas Train Pipe Size (in.) Gas Pressure Required ("w.c.) 3 FGR Line Piping (in.) Model No. & Frame Size LND-42-1 3,360 24 80-3 1 - - 1 1/2 19.86 6 LND-54-1 4,200 30 100-5 1 - - 2 15.82 6 LND-63-1 5,250 38 125-5 1 - - 2 2 PSI 6 LND-84S-2 6,300 45 150 5-1 - - 2 1/2 14.87 6 LND-84P-2 7,350 53 175-7 1/2 1 - - 2 1/2 20.71 6 LND-105-2 8,400 60 200-10 1 - - 3 2 PSI 6 208 / 230 / 460 / 3 LND-145S-3 10,500 75 250 15-2 - - 3 19.56 6 LND-145P-3 12,600 90 300-15 2 - - 3 2 PSI 8 LND-175-4 14,700 105 350-20 - 5 1/2 3 2 PSI 8 LND-210-5 16,800 120 400-25 - 5 1/2 3 3 PSI 8 LND-252-6 21,000 150 500-30 - 5 3/4 3 3 PSI 8 230 / 460 / 3 LND-300-6 25,200 180 600-40 - 7 1/2 3/4 3 10 PSI 10 LND-315-6 30,000 215 714-60 - 7 1/2 3/4 3 10 PSI 10 LND-336-7 31,500 225 750-60 - 7 1/2 3/4 3 10 PSI 10 460 / 3 LND-378-8 33,600 240 800-75 - 15 1 3 10 PSI 10 LND-420-8 37,800 270 900-75 - 15 1 4 10 PSI 10 1 Use model "S" up to 1.5" w.c. furnace pressure, consult the factory for higher pressures 2 Use model "P" up to 4.0" w.c. furnace pressure, consult the factory for higher pressures 3 Standard gas pressures only, consult the factory for lower gas pressures Input is based on fuel BTU content, listed furnace pressure and altitude of 2,000 feet or less. If altitude > 2,000 feet and < 8,000 feet, derate capacity 4% per 1,000 feet over 2,000. Consult factory for higher altitudes. If furnace pressure exceeds listed value, derate capacity 5% for every 0.5" w.c. of pressure in excess of stated. Consult factory if derate exceeds 20%. Gas input is based on natural gas with 1,000 BTU/cu.ft., 0.60 gravity, 0" w.c. furnace pressure and the aforementioned conditions. For total pressure at manifold, add furnace pressure. Oil input based on 140,000 BTU/gal and the aforementioned conditions. Consult factory for 50 Hz. applications. 13

<30 PPM Low NOx Dimension Sheet LNDG - LNDLG: Gas, Gas/Oil Size 1-4 Configuration 14 Burner Frame Size & Model Number Boiler HP Size 1 Size 2 Size 3 Size 4 DIM 42 54 63 84-105 145 175 Length in inches Overall length E 46 5/8 46 5/8 46 5/8 48 1/4 56 7/8 60 Width in inches Center line to right side I 21 5/8 21 5/8 21 5/8 23 7/8 24 3/4 25 1/4 Center line to left side J 17 7/8 17 7/8 17 7/8 17 7/8 20 5/8 21 5/8 Height in inches Center line to top F 13 5/8 13 5/8 13 5/8 15 15 15 Center line to bottom G 24 5/8 24 5/8 24 5/8 25 3/8 30 1/8 31 7/8 Dry oven dimensions in inches Diameter of dry oven A 15 7/8 15 7/8 15 7/8 19 22 27 1/2 Depth of dry oven C 9 9 9 10 12 12 Mounting flange dimensions in inches Diameter B 22 22 22 24 27 32 1/2 Flange to hinge D 18 18 18 18 21 1/2 21 1/2 Diameter of bolt circle L 20 1/2 20 1/2 20 1/2 22 25 30 1/2 Number of mounting holes K 8 8 8 12 12 12 Hinge swing dimensions in inches Center line to outer hinge clearance M 36 1/8 36 1/8 36 1/8 38 5/8 45 50 5/8 Hinge swing radius N 36 7/8 36 7/8 36 7/8 39 1/4 47 3/8 49 5/8 Oil inlet dimensions in inches Diameter of oil inlet Q 3/4 3/4 3/4 1 1/4 1 1/4 1 1/4 Mounting flange to oil inlet P 17 7/8 17 7/8 17 7/8 27 30 1/2 30 1/2 Gas inlet dimensions in inches Diameter of gas inlet R 2 2 2 2 1/2 3 3 Mounting flange to gas inlet H 3 7/8 3 7/8 3 7/8 3 5/8 4 1/8 4 1/8 Flue gas recirculation (FGR) in inches Center line of FGR to mounting flange S 41 1/2 41 1/2 41 1/2 42 3/4 47 7/8 50 Number of mounting holes T 16 16 16 16 16 16 Bolt hole diameter U 3/4 3/4 7/8 7/8 7/8 7/8 Bolt circle diameter V 7 1/2 7 1/2 9 1/2 9 1/2 9 1/2 11 3/4 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction.

<30 PPM Low NOx Dimension Sheet LNDG - LNDLG: Gas, Gas/Oil Size 5-8 Configuration Burner Frame Size & Model Number Boiler HP Size 5 Size 6 Size 7 Size 8 DIM 210 252 300 315 336 378-420 Length in inches Overall length E 64 3/4 66 3/8 66 3/8 69 3/8 68 1/2 73 7/8 Width in inches Center line to right side I 32 3/8 32 3/8 32 3/8 32 3/8 32 3/8 36 7/8 Center line to left side J 23 3/4 23 3/4 23 3/4 23 3/4 23 3/4 28 Height in inches Center line to top F 21 21 21 21 21 23 Center line to bottom G 35 7/8 37 3/8 37 3/8 37 3/8 38 7/8 39 7/8 Dry oven dimensions in inches Diameter of dry oven A 27 1/2 31 1/2 31 1/2 31 1/2 34 5/8 34 5/8 Depth of dry oven C 12 15 15 15 18 18 Mounting flange dimensions in inches Diameter B 32 1/2 37 37 37 40 42 Flange to hinge D 21 1/2 22 22 22 22 24 Diameter of bolt circle L 30 1/2 35 35 35 38 40 Number of mounting holes K 12 12 12 12 12 12 Hinge swing dimensions in inches Center line to outer hinge clearance M 54 3/8 56 7/8 56 7/8 59 7/8 60 5/8 69 1/8 Hinge swing radius N 54 58 58 59 59 5/8 68 5/8 Oil inlet dimensions in inches Diameter of oil inlet Q 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 Mounting flange to oil inlet P 30 1/2 31 31 31 30 7/8 33 3/4 Gas inlet dimensions in inches Diameter of gas inlet R 3 4 4 4 4 4 Mounting flange to gas inlet H 4 1/8 4 5/8 4 5/8 4 5/8 4 5/8 3 7/8 Flue gas recirculation (FGR) in inches Center line of FGR to mounting flange S 51 1/2 51 5/8 52 7/8 54 3/8 53 1/2 63 Number of mounting holes T 16 16 24 24 24 24 Bolt hole diameter U 7/8 7/8 1 1 1 1 Bolt circle diameter V 11 3/4 11 3/4 14 1/4 14 1/4 14 1/4 14 1/4 Accompanying dimensions, while sufficiently accurate for layout purposes, must be confirmed for construction. 15

351 21st Street, Monroe, WI 53566 USA 608.325.3141 info@ind-comb.com ind-comb.com Printed in the USA 2012 Industrial Combustion IC-SA-1573 03/12