GV Standard Skyglide Operation and Maintenance Manual

Similar documents
GV Standard Sliding Over Roof Operation and Maintenance Manual

GV Standard Three Wall Box Operation and Maintenance Manual

GV Standard 3 Wall Box Operation and Maintenance Manual

GV Standard Pyramid Operation and Maintenance Manual

GV Chain Actuated VisionVent Patent GB

GV Standard Electric Pyramid

GV Standard Skydoor Installation Instruction Manual

SECEUROGLIDE ROLLER GARAGE DOORS, SECEUROSHIELD, SECEUROSCREEN & SECEUROVISION ROLLER SHUTTERS CONTENTS

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

PSU1 Power Supply Unit

Installation & Service Manual

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

GLM SERIES CONTROL Users Manual Rev:

Multi-colour LED Status Light - using it as a diagnostic tool:

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

FREEWAY RANGE OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

EAGLETRON II REMOTE CONTROL OPERATOR and MAINTENANCE. Remote Control Procedure

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Installation Instructions

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Owner's Manual. Remote Security and Convenience System INS0866 8/98

Zip FlushMaster Surface mounted sensor

PowerLevel s e r i e s

Vision Ped Plus. Operators Guide. Studio Pedestal. Vinten Camera Control Solutions

Model S888NR & Model S889NR USER MANUAL. Please ensure this manual is read and understood before using the scooter.

TIMER PROJECT KIT ESSENTIAL INFORMATION. Version 2.0 TIME SOMETHING WITH THIS

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

Battery System User Manual for Panasonic LJ-SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ-SK56A

Battery Charger JCB-FCH20LI2

O U T B A C K P R O O F G E A R 12V / 24V (MANUAL) O U T B A C K P R O O F G E A R

OPERATING INSTRUCTIONS

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Cordless Handheld. H90-LF Series. vax.co.uk

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

VEHICLE AND PEDESTRIAN CONTROL

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

RPS1215 ORIGINAL INSTRUCTIONS. Cordless Pruner

110W CARAVAN SOLAR PANEL KIT PLU

SECTION 1 2 INSTRUMENTS AND CONTROLS. Switches

User Manual GRX- 950 and GRX- 950 Li

2 Ton - 50 Ton Bottle Jack

Zonestar Installation Manual

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Windows and mirrors ELECTRIC WINDOWS. Raise and lower. One-touch operation. Automatic window drop for door opening

Roll Up Door Operator

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

Battery Charger JCB-FCH12Li

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

PORTAGAUGE 4 USER MANUAL

20V Lithium-Ion Battery Pack

TIX402 EOS Installation and Operating Guide

SECTION B1: MACHINE COMPONENTS

Installation Instructions

Pan and Tilt Head CDD2416-T

QuickBoost Instruction Manual

Non-Contact Phase Rotation Tester

Section of 14. Ice and Rain Protection

MP V 8A Electronic Smart Charger. Instruction and Information Manual

OPERATION MANUAL for MANUAL LEVELING SYSTEMS with square foot pads on jacks

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

Product Maintenance Guide

Acoustic Door Closer Instructions

Pistol Grip Battery-powered Pressing Tool

DEEP SEA ELECTRONICS PLC

Alliance Towel Dispensing System. Operation Manual

Compact Triple Electric Step OWNERS MANUAL

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

INSTALLATION: HOW IT WORKS: SensiStat Energy Saver Refrigeration Controller. both the holding plate temperature and refrigeration box temperature.

CeraControl. Temperature Programmer User Handbook.

Adaptive cruise control (ACC)

General Precautions. Personnel Precautions

Application Guide for MasterSeal Sealants MasterSeal NP 430 MasterSeal CR 195

NCSA 20plus Service Manual

Compact Security FloodLight

Features Technical Parameters

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

G2 Optima Plus Flushometer

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

K25000 & KD25000 Series

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

Adaptive cruise control (ACC)

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

SUBMERSIBLE WATER PUMP

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

FlightPower V-Balance Module

SHIFNOID WIRING DIAGRAM

Pivotell Mark 3/11 Automatic Pill Dispenser Instructions

Transcription:

GV Standard Skyglide Operation and Maintenance Manual Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

GV Standard Skyglide Operation & Maintenance Manual SG-OM v2.1 11.01.17 Page 2 of 10 Contents Section Description Page Contents & Introduction 2 Controls and operation 3-6 Rain sensor operation 4 Manual override 6 Standard Glass Specification and Breakage Instruction 7 General Maintenance and Safety 7 Cleaning the Skyglide 8 COSHH and Safe Disposal 8 Troubleshooting 9-10 Warranty information 10 Introduction Thank you for purchasing a Glazing Vision Standard Skyglide (Figure 1). We hope that it gives you many years of service. Figure 1 Flat Skyglide

Page 3 of 10 Controls and Operation Status light Control Switch: The standard operation is via the supplied wall switch (Figure 2) and can be operated using two different methods as explained below: Figure 2 Wall mounted control switch 1. One touch operation Press and release the control switch in either the up or down (open/closed) direction as required. The rooflight will open or close fully. Press the control again to stop the rooflight partially open or closed. 2. Press and hold operation Press and hold the control switch until the rooflight has reached the desired position, releasing the switch stops the rooflight in that position. Note: the rooflight will stop automatically when it becomes either fully open or closed. Status Light: The status light will illuminate green if the rooflight is working normally. If the status light displays another colour please refer to the troubleshooting section. Operation: The Skyglide controller is powered by a 240V mains power supply that charges two 12V lead acid batteries. Power for the drive motor and controls is taken from the batteries. This feature enables the rooflight to be operated in the event of mains power supply failure. It is recommended that in the event of mains power supply failure, the rooflight is closed as quickly as possible and given a full 24 hour charge once power resumes. Note: The control board has a built-in voltage check which will prevent it opening if voltage drops critically low. Remote Control (Optional): The remote control (Figure 3) offers the same control function as the switch allowing the rooflight to be opened and closed from a short distance away. The remote control is powered by one long life A23 12V battery. The battery cover plate is found on the rear of the remote. Figure 3 Remote control Building Management (Optional): The Skyglide can be connected to building management systems to open and close the rooflight. Thermostat (Optional) The thermostat offers control of the rooflight to suit the temperature within the building. The thermostat is linked to the rooflight via a switch so that it can be turned on/off independently for security reasons.

Page 4 of 10 Proximity Detection (Optional): This option comprises photoelectric sensors positioned along the inner face of the sealing edge (the sealing edge is where the sliding frame closes towards). One sensor emits a beam which is received by the other during normal operation. If this beam is obstructed, the rooflight will stop and then back off to release the obstruction. Until the path of the beam is cleared the rooflight will not operate. This offers protection against trapping fingers or limbs at the sealing edge. Note: proximity sensor does not offer protection against the other edges of the rooflight and only protects along the inside face. Care must always be taken around motorised equipment. Rain Sensor Operation (Optional): The rain sensor (Figure 4) automatically closes the rooflight when it rains. If moisture is detected on the rain sensor when rooflight is opened, a special built in heater activates for 60 seconds to evaporate standing water. If after 60 seconds water is still detected, the rooflight will close. This feature enables the rooflight to differentiate between rain and standing water / morning dew. Figure 4 - Rain sensor Glazing Vision highly recommends that for safety reasons a balustrade is installed (by others) around the Skyglide if it is to be used for access. Internal Rain Sensor Isolator Switch (Optional): The internal rain sensor isolator switch (Figure 5) is wired directly to the rain sensor cable and allows the sensor to be switched on/off during access to a roof. Turning off the switch deactivates the signal from the rain sensor and prevents the rooflight from closing in the event of rain. This avoids the scenario where you could be shut outside by the rain sensor when it rains. Ensure the switch is turned back on for normal use Figure 5 Internal rain sensor isolator switch External Rain Sensor Isolator Switch (Optional): The external rain sensor isolator switch (Figure 6) offers the same functionality as the internal isolator switch but for use externally and with the addition of security via a key operated switch. Figure 6 External rain sensor isolator switch

Page 5 of 10 Timed Secure Open Button (Optional): The timed secured open button (Figure 7) allows the rooflight to be opened following closure by the rain sensor. The button is active during a defined period after the rain sensor has been triggered and when pressed will open the rooflight. The duration of the active period is configurable up to a maximum of 30 minutes and is set during rooflight installation. The rooflight cannot be closed using this button. External Keypad (Optional): The keypad option (Figure 8) offers secure access into the rooflight via a numerical pass code. To open the rooflight - enter the four digit code (Glazing Vision supplies an initial code with the rooflight and instructions for changing it as required). To close the rooflight - press the bell symbol in the bottom left hand corner of the keypad. Unlike the standard internal wall switch, the keypad does not offer press and hold operation. Figure 7 Timed secure open button Figure 8 External keypad External Key Switch (Optional): The key switch option (Figure 9) offers the same function as the keypad but via a key operated switch. In addition the key switch does offer press and hold operation. To open the rooflight - turn the key in a clockwise direction. To close the rooflight - turn the key in an anti-clockwise direction. Figure 9 External key switch

Page 6 of 10 Manual Override Before manually opening or closing the rooflight, follow the checks within the troubleshooting section of this manual. The Skyglide is equipped with a one way clutch in the drive mechanism (patent applied for) and a manual override. The clutch mechanism allows the unit to be pulled closed in an emergency but for security reasons cannot be opened without operating the internal manual override. The manual override is located on the base frame (Figure 10) and is accessed through a hole in the framework covered by a blanking plug. Override plug/hole in base frame Figure 10 Manual override location To manually open the unit in an emergency, remove the cover cap from the internal framework to expose a spring plunger. Pull the spring plunger to disengage the clutch mechanism. While the clutch is disengaged, the unit can be pushed open. Do not push the sliding frame beyond the base framework. If the manual override has been used the rooflight may require re-initialising. To do this manually position the rooflight approximately halfway open and re-engage the override. Then simply press the close button on the control switch. The rooflight will slowly creep to its fully closed position. The rooflight is then ready to resume normal service.

Page 7 of 10 Standard Glass Specification and Breakage Instructions Glass Specification The Skyglide is available with double glazing or triple glazing as standard and various options at time of order. Standard double glazing comprises a 4mm HST toughened outer pane, a 20mm warm edge spacer argon filled black silicone sealed cavity and a 4mm HST soft coat Low E toughened inner pane. Standard triple glazing comprises a 4mm HST toughened outer pane, a 12mm warm edge spacer argon filled black silicone sealed cavity, a 4mm HST soft coat Low E toughened centre pane, 12mm warm edge spacer argon filled black silicone sealed cavity and, a 4mm HST soft coat Low E toughened inner pane. If specific data is required for the glazing installed within your rooflight, please contact Glazing Vision for a glass data sheet. Breakage Instructions In the unlikely event the glazed unit should break for any reason, due to the unique method of bonding the glass unit into the frame, a new lid would need to be supplied. Glass breakage is not covered in the product warranty unless the breakage is a direct result of Glazing Vision Limited or its product failing. In the event of the glass being damaged please contact Glazing Vision for assistance. General Maintenance & Safety To keep the Skyglide in good working order there are a few basic points that should be observed: Do not place anything on the lid or cause obstruction to the lid of the Skyglide when opening the unit as this may cause damage to the unit s mechanisms. Do not walk on the unit. Make sure fingers and other obstructions are clear of the unit before closing the unit (although there is an overcurrent feature built into the circuit board to detect an obstruction, damage/injury may be caused). It is recommended that a general inspection is carried out on the unit wherever possible at least once every 6 months. Glazing Vision, if required, can offer a service / maintenance contract. Please contact our project office for further details. Do not remove the plastic cover plate protecting the printed circuit board (PCB), as this may allow the PCB to become damaged. Keep the frame clear of general dirt and debris particularly around the opening mechanism. Do not allow unauthorised persons (e.g. Children) to operate the rooflight as this may lead to injury or damage to the product.

Page 8 of 10 Cleaning the Skyglide Due to the Skyglide s unique bonding method and slight pitch built into the kerb, there should be no water ponding on the glass when installed correctly. Any standard glass-cleaning product can be used to clean the glass unit. However do not use abrasive materials or cleaners as this may affect the unit and its finish. The framework of the unit can be cleaned using warm soapy water with a soft lint free cloth. COSHH and Safe Disposal Materials used in the construction of the Skyglide are recyclable. When disposing of the Skyglide, recycle as much as possible. Do not burn any plastic materials. The following materials are used throughout the Skyglide: Framework Aluminium corner brackets Polyamide thermal break strips Stainless steel fixings Polyethylene backing rod Stainless steel Toughened glass panes Low modulus silicone Composite spacer bar PVC foam tape Closed cell insulation Acrylic adhesive (corner joints) Silicone rubber seals Polyester powder coated finish Plastic cable trunking Aluminium extrusion Mechanisms and control Stainless steel fixings Printed circuit board (PCB) Stainless steel drive shaft SPST rocker switch Stainless steel solenoid bolt Copper wiring Stainless steel coupling Electric motor Aluminium limit switches and magnet HIPS electronics enclosure Steel telescopic sliding rails Standard insulated spade terminals Polymer bearings 626Z Bearing Delrin pinions Lead acid battery

Page 9 of 10 Troubleshooting The Skyglide control board monitors the operation of the rooflight. If a fault is detected, the board will stop the rooflight to prevent possible damage. Fault and standard conditions are indicated by the status light on the control switch (Figure 2). The table below shows the various status lights displayed and their meanings. Although the rooflight will still operate following detection of a fault please observe the status displayed and attempt to resolve the issue with the suggested action. Avoid operating the rooflight if the fault persists. In this case, contact Glazing Vision for further assistance. Status light shown: Continuous Green Meaning: Lit whilst rooflight is in motion under the control of the operating switch or remote control with no faults present. If rooflight is onetouch opened or closed LED will remain lit until motion stops. Intermittent Green Flashes whilst rooflight is in motion but not under control of the operating switch or remote control. Flashing will stop when motion stops (i.e. whilst controlled by rain sensor or B.M.S). Continuous Red Lit whilst rooflight is closing and battery is at low level (regardless of whether mains is present or not). Control system will ignore requests to open from sealed state. Intermittent Red Lit whilst rooflight is in motion and no mains is present. To tell you there is a power failure and the batteries are not being charged. Continuous Blue Indicates a seal timeout, opening timeout or closing timeout condition. LED remains lit if mains is present, until control switch is pressed. Intermittent Blue Indicates an over-current or undercurrent condition. Flashes if mains is present, until control switch is pressed. Continuous Yellow Indicates that a safety device is active preventing rooflight operation. If a fault occurs please refer to the table on the next page. Some faults with the unit may be easily corrected without the need for a site engineer, however if you are unsure, please contact Glazing Vision Ltd.

Page 10 of 10 Status Light Shown Possible Cause Action Continuous Green (No Fault) Intermittent Green (No Fault) - No action required - No action required Continuous Red (Low Battery) Batteries are at low level, possibly coming to the end of their service life. Check that the mains electrical supply is switched on and connected to the rooflight. Leave rooflight for 24 hours, then check status again. If fault persists, contact Glazing Vision. Intermittent Red (Mains supply absent) No mains electricity is getting to the rooflight. Reconnect mains electrical supply to rooflight. Is there a mechanical obstruction preventing the sliding frame from moving? If possible, look at the mechanisms and remove any obvious obstructions. Continuous Blue (Sealing Fault) Is the sliding frame frozen to the base? Attempt to open the rooflight once ice has melted. Has the rooflight been left inactive for a long period (a month or longer)? A sealing fault is likely after a long period of inactivity. If fault persists contact Glazing Vision. Intermittent Blue (Over-current) Is there a mechanical obstruction preventing the sliding frame from moving? Remove any obstruction preventing movement and try again. If fault persists contact Glazing Vision. Skyglide opens or closes for no apparent reason. This should only occur if a rain sensor or building management system is fitted. When either of these devices activates your rooflight the status LED will flash green. This is not a fault condition. Product Warranty A warranty document will be provided with the rooflight. If this is misplaced it can be found at www.glazingvision.co.uk/resources/warranties/.