DESCRIPTION The Encounter redefines ambient lighting by being the first fixture to blend modern contemporary styling with the innovative WaveStream technology to deliver exceptional performance and superior energy savings. Encounter s highly efficient LED system with advance optical design delivers an unparalleled combination of optimal light uniformity for enhanced visual comfort and superior efficiency for greater energy savings. Encounter is compatible with all of today's popular ceiling systems and available in a variety of configurations for application versatility. Its perfect balance of form and function make it an ideal choice for commercial office spaces, schools, hospitals, retail and other indoor ambient applications. Catalog # Project Comments Prepared by Metalux Date SPECIFICATION FEATURES Construction Shallow 3-1/16 deep housing is extruded aluminum frame and injected molded composite end plates. End plates are securely attached with screws for strength and rigidity and the elimination of gaps. End plates have accessory grid-lock feature for safety and convenience. Four auxiliary fixture end suspension points are provided. Large access plate for supply connection. Controls Metalux LED luminaires come standard with -V dimming drivers (1% standard). Options compatible with s Connected Lighting Systems: WaveLinx sensor LumaWatt Pro sensor SVPD sensor DLVP sensor and driver Fifth Light DALI driver Other options include stepdimming and 3rd party drivers. Refer to the Connected Lighting options page and ordering information for more details. Electrical Long-life LED system coupled with electrical driver to deliver optimal performance. LED s available in 3K, 3K, 4K or K with a minium CRI of 8. Projected life is, hours at 92% lumen output. Electronic drivers are available for 12-277V applications. Emergency Battery Pack Option Optional 12V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 9-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/ indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. Emergency/generator transfer options available see ordering information for details. Driver Access Drivers can be accessed via plenum. Finish Durable frame has high reflectance baked matte white enamel finish for luminous uniformity. Optics Precision formed optical assembly with positively retained high optical grade acrylic lenses provide a directed optical distribution using WaveStream technology. Compliance Components are UL recognized. Indoor luminaires are culus listed for 2 C ambient environments, RoHS compliant, and comply with IESNA LM-79. LEDs comply with LM-8 standards. DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www. designlights.org for details. Warranty Five-year warranty. 14EN LED 1' X 4' TROFFER LED MODULE Specification Grade Troffer 3-1/16" [78mm] MOUNTING DATA 11-3/4" [298mm] CERTIFICATION DATA culus - 198 and 243** Damp Location Listed IC Rated LM79/LM8 Compliant ROHS Compliant DesignLights Consortium Qualified NOM Compliant 11-3/4" [299mm] 47-3/4" [1213mm] CEILING COMPATIBILITY *See Drywall Frame Kit Accessory in Ordering Information section. **Fixture construction is suitable for use in Air-handling and plenum rated spaces in accordance with Section 3.22 (C) of the National Electrical Code, Section 4.3.11.2.6. of NFPA 9A and Section 62.2.1.4 of ICC. G Grid/Lay-in Standard F Drywall Frame Kit Ceiling Trim Exposed Grid G Concealed T G or T Slot Grid G or T Flange * Safe and convenient means of disconnecting power PS196EN May 4, 218 1:1 PM
PHOTOMETRICS 3 6 9 1 3 14EN-LD2-2-UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.3 x mounting height, ( ) 1.3 x mounting height Lumens: 27 Input Watts: 2.9W Efficacy: 12. lm/w Test Report: 14EN-LD2-2-UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 2 2 3 3 4 4 6 6 7 7 8 8 9 843 843 843 84 836 842 828 827 833 811 811 819 788 79 8 77 762 77 721 729 742 682 688 72 637 641 64 87 88 97 34 29 33 474 464 463 47 392 39 337 314 312 262 243 218 183 162 136 8 92 4 42 49 49 rc 8% 7% % 3% % % rw 7 3 7 3 3 3 3 RCR 1 2 3 4 6 7 8 9 9 7 6 4 119 119 119 119 116 116 116 116 111 111 111 6 6 6 2 2 2 9 4 99 9 6 1 97 94 97 94 91 93 91 88 9 87 8 83 99 9 83 77 96 88 82 76 8 79 7 81 77 73 78 7 71 69 9 79 71 64 87 77 7 64 74 68 62 72 66 61 69 64 6 8 82 7 61 4 8 69 6 4 66 9 3 64 7 2 61 6 2 49 7 62 3 46 73 61 3 46 9 1 46 7 4 49 4 42 7 6 47 4 68 46 4 3 46 4 2 4 4 44 39 37 64 1 42 36 63 41 3 48 41 3 47 4 3 4 39 3 33 6 46 38 32 8 46 37 32 44 37 31 43 36 31 42 36 31 29 6 42 34 28 4 42 34 28 41 33 28 4 33 28 38 32 28 26 2 39 31 26 1 39 31 26 38 3 26 37 3 2 36 3 2 24 Zonal Lumen Summary Zone Lumens % Fixture -3 662 26.4-4 94 43.6-6 196 78.4-9 27. -18 27. 4 8 12 1 3 14EN-LD2-33-UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.3 x mounting height, ( ) 1.3 x mounting height Lumens: 3329 Input Watts: 28.1W Efficacy: 118. lm/w Test Report: 14EN-LD2-33-UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 2 2 3 3 4 4 6 6 7 7 8 8 9 1123 1123 1123 1119 1114 1122 14 11 11 79 8 91 47 1 66 8 14 33 961 97 988 96 916 934 847 83 869 781 782 794 78 73 78 629 616 614 41 18 16 449 417 413 346 32 288 243 213 179 14 122 138 3 64 62 rc 8% 7% % 3% % % rw 7 3 7 3 3 3 3 RCR 1 2 3 4 6 7 8 9 9 7 6 4 119 119 119 119 116 116 116 116 111 111 111 6 6 6 2 2 2 9 4 99 9 6 1 97 94 97 94 91 93 91 88 9 88 86 83 99 9 83 77 96 88 82 77 8 79 7 81 77 73 78 7 71 69 9 79 71 64 87 77 7 64 74 68 62 72 66 61 69 64 6 8 82 7 61 4 8 69 6 4 66 9 3 64 7 2 62 6 2 49 7 62 3 47 73 61 3 46 9 2 46 7 4 49 4 43 7 6 47 41 68 47 4 3 46 4 2 4 4 44 39 37 64 1 42 36 63 42 36 48 41 3 47 4 3 46 39 3 33 6 46 38 32 8 46 37 32 44 37 31 43 36 31 42 36 31 29 6 42 34 29 42 34 28 41 33 28 4 33 28 39 32 28 26 2 39 31 26 1 39 31 26 38 31 26 37 3 2 36 3 2 24 Zonal Lumen Summary Zone Lumens % Fixture -3 882 26. -4 146 43.7-6 2613 78. -9 3329. -18 3329. Peachtree City, GA 3269 P: 77-486-48 PS196EN May 4, 218 1:1 PM
LUMEN MAINTENANCE Ambient Temperature TM-21 Lumen Maintenance (, hours) Theoretical L7 (Hours) 2 C > 92% > 448, Non-IC data 9 CRI Lumen Adjustment Factors 8->9 CRI 3K.861 3K.864 4K.883 K.86 Example of Lumen Adjustment Calculation 14EN-LD2-2-UNV-L83-CD1-U at 9CRI at 3K Lumen Adjustment Factor =.864 Total Light Output = 2,7 lm x.864 = 2,166 lm Efficacy = 2,166 lm = 3.6 lm/w 2.9 W ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER Stock or MTO* Catalog Logic (Curved) Delivered Lumens Watts Efficacy (LPW) MTO 14EN-LD2-18-UNV-L83-CD1-U 18 16. 113 MTO 14EN-LD2-18-UNV-L83-CD1-U 186 16. 116 MTO 14EN-LD2-18-UNV-L84-CD1-U 1893 16. 118 MTO 14EN-LD2-18-UNV-L8-CD1-U 26 16. 129 MTO 14EN-LD2-2-UNV-L83-CD1-U 2432 2.9 116 MTO 14EN-LD2-2-UNV-L83-CD1-U 27 2.9 12 MTO 14EN-LD2-2-UNV-L84-CD1-U 27 2.9 122 MTO 14EN-LD2-2-UNV-L8-CD1-U 2783 2.9 133 MTO 14EN-LD2-28-UNV-L83-CD1-U 2729 23.6 116 MTO 14EN-LD2-28-UNV-L83-CD1-U 2813 23.6 119 MTO 14EN-LD2-28-UNV-L84-CD1-U 2869 23.6 122 MTO 14EN-LD2-28-UNV-L8-CD1-U 3122 23.6 132 MTO 14EN-LD2-33-UNV-L83-CD1-U 3229 28.1 11 MTO 14EN-LD2-33-UNV-L83-CD1-U 3329 28.1 118 MTO 14EN-LD2-33-UNV-L84-CD1-U 3396 28.1 121 MTO 14EN-LD2-33-UNV-L8-CD1-U 369 28.1 131 MTO 14EN-LD2-38-UNV-L83-CD1-U 3723 32.8 114 MTO 14EN-LD2-38-UNV-L83-CD1-U 3838 32.8 117 MTO 14EN-LD2-38-UNV-L84-CD1-U 391 32.8 119 MTO 14EN-LD2-38-UNV-L8-CD1-U 426 32.8 13 MTO 14EN-LD2-43-UNV-L83-CD1-U 42 37.6 112 MTO 14EN-LD2-43-UNV-L83-CD1-U 433 37.6 11 MTO 14EN-LD2-43-UNV-L84-CD1-U 4422 37.6 118 MTO 14EN-LD2-43-UNV-L8-CD1-U 4812 37.6 128 MTO 14EN-LD2-47-UNV-L83-CD1-U 486 41. 111 MTO 14EN-LD2-47-UNV-L83-CD1-U 4728 41. 114 MTO 14EN-LD2-47-UNV-L84-CD1-U 4823 41. 116 MTO 14EN-LD2-47-UNV-L8-CD1-U 248 41. 126 MTO 14EN-LD2-1-UNV-L83-CD1-U 4963 44.7 111 MTO 14EN-LD2-1-UNV-L83-CD1-U 117 44.7 114 MTO 14EN-LD2-1-UNV-L84-CD1-U 219 44.7 117 MTO 14EN-LD2-1-UNV-L8-CD1-U 68 44.7 127 *Made to order (MTO) requires a typical two week lead time. Peachtree City, GA 3269 P: 77-486-48 PS196EN May 4, 218 1:1 PM
ORDERING INFORMATION SAMPLE NUMBER: 1 4EN-LD2-33-UNV-L83-CD1-SVPD1-U Rating Blank=Standard ATW-SW4=Chicago Rated () (6) Series 14EN=1' x 4' Encounter Series Air [Blank]=Standard (7) A=Air (Vented) Lamp LD2=LED 2. MTO Lumen Outputs 18=18 Lumens 2=2 Lumens 28=28 Lumens 33=33 Lumens 38=38 Lumens 43=43 Lumens 47=47 Lumens 1= Lumens Optics Blank=Standard Voltage (1) UNV=Universal Voltage 12-277 347V=347 Volt (4) 48V=48 Volt Low-voltage (Class 2) (C) Options Emergency EL7W=7-watt, 12V-277V emergency battery pack installed (2) EL14W=14-watt 12V-277V emergency battery pack installed (2) ELV7W=7-watt, DLVP-compatible low voltage emergency battery pack installed (C) ELV14W=14-watt DLVP-compatible low voltage emergency battery pack installed (C) GTR2=Bodine Generator Transfer Relay (8) ETR2=Iota Emergency Transfer Relay (8) ETRD=Iota Emergency Transfer Relay with dimming control (8) CCT L83=3K L83=3K L84=4K L8=K L93=3K L93=3K L94=4K L9=K Flex A3/8-4/18GDIM=3/8" Flex with -V Dimming Leads Multiple other configurations available. See below for details. Driver Number of Drivers CD=-V Dimming Driver 1=1 Driver (1%-% Dimming) SR=Sensor-ready Dimming Driver for LWIPD1 option (1%-% Dimming) (B) LTD=Fifth Light DALI Driver (3), (E) (%-% Dimming) LTHD=Fifth Light Dimming Driver (1%-% Dimming) (E) LV1=DLVP Dimming Driver (%-% Dimming) (C) SD=Step Dimming Driver (% or % Dimming) (3) LH=Lutron HiLume (LDE1 series) 1%-% EcoSystem Driver with Soft-on Fade to Black dimming (F) L=Lutron Series (LDE-Series) %-% EcoSystem Driver (F) LU=Lutron HiLume (L3D series) 1%-% EcoSystem/3-wire Driver (F) Integrated Sensing Systems SWPD1=WaveLinx Wireless Integrated Sensor (A) LWIPD1=LumaWatt Pro Wireless Integrated Sensor (B) LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (B) SLVPD1=DLVP Low-voltage Integrated Sensor (C) SVPD1=-V Stand-alone Integrated Sensor (D) Packaging U=Unit Pack PALC=Job Pack, in carton ACCESSORIES T3A END E.Q. BRACKET PARTS BAG (Standard with fixture) DF-14-W=1' x 4' Drywall Frame Kit SK-14-WT=1' x 4' Tall Surface Mount Kit DFP-C =Decorator Dimmer, -V SFP- =Decorator Slide Dimmer, -V ISHH-1=Programming Remote for Integrated Sensor (D) ISHH-2=Personal Control Remote for Integrated Sensor (D) NOTES: (1) Products also available in non-us voltages and frequencies for international markets. (2) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack ( lm/w x 7=7 lumens). IES-format photometry for luminaire under emergency operation available. (3) 18, 2, 28 and 33 lumen packages not available with Step-dim or LTD option. (4) 347V emergency option not available. () Chicago rated version does not allow for row mounting. (6) DesignLights Consortium Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. (7) Air version is vented but does not meet air handling requirements. (8) Used to bypass local control during outage. Must be used in conjunction with UL 8 device (provided by others). GTR2 and ETR2 options include 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 12V or 277V when ordering these devices. Integrated Sensing and Control System Options NOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) Consult LumaWatt Pro system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. Flexible Metal Conduit Options Flex options available for -V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 9 enclosed FMC connector. Not all options may be combined and installation ratings vary by type. A3/8-4/18GDIM series notes: Factory installed dimming option 3/8 flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed -V +/- control wires. Meets UL 66, 83, 1479, 169, 181, 26. NEC 2.118, 3.22(C), 392, 396, 33, 1, 2, 3, 3, 4,, 18, 2, 3, 64, 72; Federal Specification A-A-944 (formerly J-C-3B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC ; Environmental Air-Handling Space Installation per NEC 3.22(C ). Specifications & Consult your Representative for availability and ordering information. SHIPPING DATA Catalog No. 14EN-LD2-33 Wt. 1 lbs. Peachtree City, GA 3269 P: 77-486-48 PS196EN May 4, 218 1:1 PM
LO SET MIN stored light levels.. 14EN LED 1' X 4' INTEGRATED SENSOR The Encounter and Encounter HP with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Encounter delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Encounter delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. upied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-1). The integrated sensor personal remote (Catalog Number: ISHH-2) provides code compliant manual raise, lower, ON, OFF control. The Encounter with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 2 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. Energy Savings Opportunities Light Level (DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level (DU) Unoccupied Level Unoccupied upied Unoccupied upied Target light level default: lux at 8 ft. Coverage Coverage Top View C L 3.3m [ ft.] Side View m [ ft.] Major Motion m [ ft.] m [ ft.] Reccomended Mounting Height 8 12 ft. Optional Remote Controls Raise/ Lower Raise/ Lower Time Out SCENE MAX HI 7 ES 1 7 2 MIN MAX To Set Output Un 1. Raise, Lower or Press Min., 7, Max. 2. To save press SET 3. Select or Un ES To Select Scenes Un Press the SCENE button. The lighting will adjust to Programming Remote ISHH-1 ISHH-1 Programming Remote Personal Remote ISHH-2 ISHH-2 Personal Control Remote Peachtree City, GA 3269 P: 77-486-48 PS196EN May 4, 218 1:1 PM