Transport, Storage & Handling Instructions

Similar documents
Operation & Instructions Manual SA 3 - SA 100 SAR 3 - SAR 100

Lever gearboxes GF 50.3 GF 250.3

Part-turn gearboxes GSI 63.3 GSI qualified for use in nuclear power plants (Inside/Outside Containment)

Part-turn gearboxes GS 50.3 GS 250.3

Reduction ratio. Factor 1)

GEARBOXES for operation of industrial valves

Part-turn actuators SGExC 05.1 SGExC 12.1 AUMA NORM (without controls)

Factor 1) Modulating torque 4) [Nm]

Valve attachment Gearbox Reduction ratio :1 5) : ,

Factor 2) 160:1 6) /(30) FA10 (FA14) :1 6) /(30) FA10 (FA14) 27 86

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Multi-turn actuators SAExC 07.1 SAExC 16.1 SARExC 07.1 SARExC 16.1 AUMA NORM (without controls)

OPERATION INSTRUCTONS MODEL SG 05.1 SG Quarter-Turn Actuators

Multi-turn actuators SAEx 07.2 SAEx 16.2 SAREx 07.2 SAREx 16.2 with actuator controls AUMA MATIC BASIC AMBExC01.1

Factor 3) Max. input torques Flange 38 GS : F ,000 F10 F ,000 F12 82:

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Part-turn actuators SQEx 05.2 SQEx 14.2 SQREx 05.2 SQREx 14.2 with local controls AUMA SEMIPACT SEMExC 01.1

Multi-turn actuators SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 with local control unit AUMA SEMIPACT SEM 01.1/SEM 02.1

Part-turn actuators SQ 05.2 SQ 14.2/SQR 05.2 SQR 14.2 with actuator controls AUMA MATIC AM 01.1

Operating instructions for worm gear boxes

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Multi-turn actuators SAI 07.1 SAI 16.1/SARI 07.1 SARI 16.1 AUMA NORM (without controls) qualified for use in nuclear power plants according to TU

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

Part-turn actuators SQ 05.2 SQ 14.2/SQR 05.2 SQR 14.2 with local control unit AUMA SEMIPACT SEM 01.1/SEM 02.1

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Part-turn actuators SQEx 05.2 SQEx 14.2 SQREx 05.2 SQREx 14.2 with actuator controls AUMA MATIC AMExC 01.1

LED Twister II. User manual UK Version 1.0

Maintenance manual XT modules

Installation. Standard AC Motors A-305. Standard AC Motors Introduction. Installation. Induction Motors. Reversible Motors.

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

ZX6 INTRODUCTION ZX6 HOIST 2 : 1 4 : 1. Rope Reeving. Speeds 4/1.3 m/min 5/1.6 m/min 6/2 m/min 8/2.6 m/min. Lift 6.5m 10m 15m

Technical Data Part-turn gearbox 2SP78

Single Sluice Gate Drive Type 1211/ / / ,5 1211/

Operating Instructions

Powered. chain hoists. Electric and pneumatic. chain hoists

Electric part-turn actuators

Operating Instructions

Made to measure: the new FM-X.

Electric Actuators Valve Gearboxes

HF2 Gauge Installation Guide Scantech

Part-turn gearboxes. Worm gearboxes GS 50.3 GS for flange types FA. Operation instructions

Interlocks 200 Series

Interlocks 325 Series

Multi-turn actuators SAI 25.1 SAI 35.1/SARI 25.1 SARI 30.1 AUMA NORM actuator (without controls) for use in nuclear power plants

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

Operating instructions ATLAS Climber - 700

Electric actuators - Valve gearboxes

50 Gordon Drive, Rockland, Maine MOUNT KIT

UNIT III TRANSMISSION SYSTEMS CONTENTS: Clutch-types and construction Gear boxes- manual and automatic Gear shift mechanisms Over drive Transfer box

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

Pull Type Gas Springs

Operating and Maintenance Instructions. Abteilung TB, Schell Seite 1 8 SERIES 56

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Small Geared Motors Series G2

Greater Cairo Foundries. Concentric Rubber Lined Butterfly Valves

STAGEMAKER CONCERT HOISTS Raising the Standard of Performance

Danger: To avoid any vehicle damage, serious personal injury or death:

Large Enclosure Safe Handling Requirements. Do not reposition until permanently installed.

AC Induction Motors. Installation and operating instructions

Installation, Operation and Maintenance Manual

GIS Electric Chain Hoists

USER MANUAL PAR56 LED PAR CANS

Valtek Auxiliary Handwheels and Limit Stops

Ball Valves. Data sheet. Description

Butterfly Valve Type 58 (PDCPD)

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES

Support legs. Installation and operating instructions

Patented! Rotating hand. Chain guide. Hoisting Equipment Hand chain hoists. Hand chain hoist model Yalelift 360. Capacity kg.

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE GENERAL INDUSTRY SAFETY STANDARDS

Valves. Storage, Preservation and Handling Manual

Standard Lockers Series Double Tier Installation Instructions

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52.

Butterfly Valve APORIS 16. DN PS 16 bar. Type Series Booklet

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH :85366 MOOSBURG TEL. ( ) FAX ( )

ELECTRIC LIFTING HOIST

Standard JIP ball valves (PN 16, 25, 40)

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

4 Run-in regulations Individual parts have run-in regulations which must be adhered to after:

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

VALUE KING ELECTRIC WIRE ROPE HOIST. COLUMBUS McKINNON CORPORATION LIFTING MOTOR BRAKE REDUCER DRUM WIRE ROPE ROPE GUIDE

PRECAUTIONS To ensure personal safety and proper maintenance, please read this section. CAUTION

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

OPERATING & INSTRUCTION MANUAL

State-Of-The-Art Delayed Coking Unheading Technology To Improve Safety During Operation RefComm Budapest 2017

Graphical representation of a gear

Power consumption In operation At rest For wire sizing. Non-operating temperature

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

VAG RIKO Plunger Valve

VEM motors Thurm GmbH

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Sofa Slideout Assembly OWNER'S MANUAL. Rev: Page 1 Sofa Slideout Owners Manual

The world is movement

Demag DC-Pro Chain Hoist Demag DCM-Pro Manulift. The New High Performance Hoists

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

Transcription:

Transport, Storage & Handling Instructions AUMA India products are high-value electro-mechanical devices. This should be taken into account during transport, storage and handling. In order to avoid possible damages, inconvenience and costs for you and us, please observe following points.

1. Transport For transport to the place of installation, use sturdy packaging. Avoid packages from exposing to open atmospheres during transit. Protect packages against rain during transit. Do not hit with hand wheel against wall, floor or machine parts. Hovering Load! Risk of death or serious injury. Do NOT stand below hovering load. Attach ropes or hooks for the purpose of lifting by hoist only to housing and NOT to hand wheel Actuators mounted on valves: Attach ropes or hooks for the purpose of lifting by hoist to valve and NOT to the actuator / actuator hand wheel. Actuators mounted to gearboxes: Attach ropes or hooks for the purpose of lifting by hoist only to the gearbox using eyebolts and NOT to the actuator. Actuators mounted to controls: Attach ropes or hooks for the purpose of lifting by hoist only to the actuator and NOT to the controls. 2. Storage Long-term storage Even in watertight enclosed products condensed water collects due to temperature fluctuations. This may damage sensitive internal parts. Damages can be avoided by observing the following points. Store in a well-ventilated, dry room. Protect against floor dampness by storage on shelves, cage boxes or on wooden pallets. Cover with plastic foils to protect against dust and dirt etc. Protect suitably against mechanical damages. Apply suitable corrosion protection agent to uncoated surfaces. For actuators: Check or at least random checks after approx. every 3 months. In case of condensed water inside the switch compartment, it has to be dried out. If the device has to be stored for a long period (more than 6 months) the following points must be observed in addition: Prior to storage: Protect bright / uncoated surfaces, in particular the output drive parts and mounting surface, with long-term corrosion protection agent. At an interval of approx. 6 months: Check for corrosion. If first sign of corrosion show, apply new corrosion protection. Page 1 of 6

3. Handling For actuators: Refer figure 3.1 and 3.2 for handling of AUMA actuators. Put ropes on both side of the housing as shown in the figure 3.1 and lift gently with the help of a hook. Care should be taken so that rope does not slip-off. Do not lift the actuator by using hand wheel or the thread provided in the adapter. For flange mounted worm gearboxes (GS): Flange mounted worm gearboxes from GS 40.2 to GS 125.2 can be handled manually. Refer figure 3.3 for handling flange mounted worm gearboxes GS 160 and above. Refer Figure 3.4 for handling flange mounted worm gearboxes with secondary spur gearbox (GS with GZ). Put 2 nos. suitable eyebolts on both side of the assembly as shown in the figure 3.3 and lift gently by putting the rope in the hook to eyebolt. Handle carefully so that the gearbox does not tilt in the opposite direction or slip-off. For foot mounted worm gearboxes (GF): Foot mounted worm gearboxes from GF 63.2 to GF 100.2 can be handled manually. Refer figure 3.5 for handling foot mounted worm gearboxes GF 125.2 and above. Put ropes on two sides of worm shaft side housing ends and lift gently with the help of hook. Handle carefully so that the gearbox does not slip-off. For bevel gearboxes (GK): Bevel gearboxes from GK 10.1 to GK 16.1 can be handled manually. Refer figure 3.6 for handling bevel gearboxes GK 25.1 and above. One number suitable eyebolt is provided on one side as shown in the figure. Lift gently by putting the rope in the hook to eyebolt. For spur gearboxes (GST): Spur gearboxes from GST 12 to GST 100 can be handled manually. Refer figure 3.7 for handling spur gearboxes GST 200 and above. Put the suitable eyebolt in the space provided. Put the rope with the hook to the eyebolt. Put the other end of the rope around the housing at the input side and lift gently as shown in the figure 3.7. For flange mounted worm gearboxes with actuators (SA + GS): For GS 40.2 to GS 400 with the corresponding actuator the following handling procedures may be adapted: Refer figure 3.8 for general arrangement of the flange mounted worm gearbox with actuator. A suitable eyebolt is provided on the gearbox side as shown in the figure 3.8. Page 2 of 6

Put suitable rope around the actuator and to the eyebolt by using S hook as shown. o Lift gently so that the output drive of gearbox faces the valve flange which will be easier for mounting. For foot mounted worm gearboxes with actuators (SA + GF): For GF 63.2 to GF 250 with the corresponding actuator the following handling procedures may be adapted: Refer figure 3.9 for general arrangement of the foot mounted worm gearbox with actuator. Lift gently by putting rope around the actuator and other end of worm shaft housing with the help of hook as shown in figure 3.9 Handle carefully so that the gearbox with actuator does not slip-off. For bevel gearboxes with actuators (SA + GK): For GK 10.1 to GK 35.1 with the corresponding actuator the following handling procedures may be adapted: Refer figure 4.0 for general arrangement of the bevel gearbox with actuator. One no. suitable eyebolt is provided on one side of the gearbox. Put the rope around the actuator and the eyebolt by using S hook as shown in the figure 4.0. Lift gently so that the combination does not tilt in opposite direction. For spur gearboxes with actuators (SA + GST): For GST 12 to GST 1600 with the corresponding actuator the following handling procedures may be adapted: Refer figure 4.1 for general arrangement of the spur gearbox with actuator. One no. suitable eyebolt is provided on the gearbox. Lift gently by putting the rope around the actuator and to the eyebolt with the help of hook as shown in the figure 4.1. Care should be taken so that the gearbox with actuator does not slip-off. Page 3 of 6

Pictorial handling instructions For actuators For AUMA Norm Actuators For AUMA Epac / Compact Actuators Figure 3.1 For flange mounted worm gearboxes (GS) For Flange mounted worm gearboxes (GS series) Figure 3.2 For Flange mounted worm gearboxes with secondary spur gearbox (GS with GZ) Figure 3.3 For foot mounted worm gearboxes (GF) Figure 3.4 For bevel gearboxes (GK) Figure 3.5 Figure 3.6 Page 4 of 6

For spur gearboxes (GST) Figure 3.7 For flange mounted worm gearboxes with actuators (SA + GS) Figure 3.8 For foot mounted worm gearboxes with actuators (SA + GF) Figure 3.9 For bevel gearboxes with actuators (SA + GK) Figure 4.0 For spur gearboxes with actuators (SA + GST) Figure 4.1 Page 5 of 6