Level switches Series LC40 Float level switch for liquids

Similar documents
Flow switches Series AD/VH

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Turbine flowmeters Series TM

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube variable area flowmeter for gases, liquids and steam

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Plastic tube variable area flowmeter for liquids and gases

Instructions Manual. Target Disk Flow meter DP-65 / DP-500. Series DP-65 DP-500. instrumentation for fluids

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Oscillating piston flowmeter series COVOL Instructions manual

OPTISWITCH 4000/5000. Vibration level switches for liquids

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Flap-Type Flow Meter Prall

CONSTRUCTION AND DESIGN OF INSTRUMENTS FOR FLOW, LEVEL AND TEMPERATURE

Type MR 783 Magnetic level switch

K - Flow Meter with Float

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

2 way ball valve M1 with pneumatic actuator

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Level Limit Switch liquiphant FTL 365 / FTL 366

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

PF6 Stainless Steel Piston Actuated On/Off Valves

2/2-way Globe Valve for media up to +180 C, DN

CONSTRUCTION AND DESIGN OF INSTRUMENTS FOR FLOW, LEVEL AND TEMPERATURE. EMCO Liquid Level Switch

GA 24 Heavy-duty variable area flowmeter

Angle Seated Valves. ecoflo-as. Angle Seated Valves

Design and application

PF6 Stainless Steel Piston Actuated On/ Off Valves

2/2-way-Globe Valve with stainless steel design for media up to +180ºC, DN 13-50

L21 Magnetic Level Indicator

Level switch brochure

Magnetic float switch For vertical installation Model FLS

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

BALL VALVE SERIES Electric actuator - El-O-matic

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page

BALL VALVE SERIES Electric actuator - El-O-matic

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

NIVOSWITCH R-400/R-500

Magnetic Level Gauges

Type Electrically Actuated Ball Valve

Knife gate valve HG - Standard

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2 way ball valve S4 with pneumatic actuator

Type Electrically Actuated Ball Valve

NIVOMAG MAGNETIC LEVEL SWITCHES GENERAL DESCRIPTION MODEL SELECTION SUPPLEMENTARY DATA. Temperature diagram: Temperature specification for Ex versions

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of

NIVOMAG O UR P ROFESSION IS Y OUR L EVEL

motor driven metering pumps

STEEMCO Flowmeter for Steam

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Magnetic Level Gauges

TORRIX Magnetostrictive level sensor

For industrial applications For marine applications With proximity switch. Piston type flow switches

motor driven metering pumps

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Level Limit Switch liquiphant FTL 360 / FTL 361

OPTIMASS 3000 Technical Datasheet

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

2/2 way Angle-Seat Valve for medium up to C, DN15-50

motor driven metering pumps

FF03. Rotary Blade Level Switch for bulk goods. Level Measurement and Monitoring

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Angle Seat Control Valve 7020

Absolute pressure gauge with diaphragm

High Temperature Valve 8024

Type 147. Electrically Actuated Lug Butterfly Valve

Pneumatic control unit for decentralized automation of ELEMENT process valves

STEEMCO-MAS Flowmeter for Steam

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

NON-RETURN VALVE RT25

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

LEVEL CONTROL 3

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

UNIWORLD series PNEUMATIC VALVES

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe

Electromagnetic Flow Monitor magphant

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

BM 26 BASIC/ADVANCED Technical Datasheet

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Magnetic Inductive Flowmeter EP / UMF2 (B)

BALL VALVE SERIES Electric actuator - El-O-matic

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

Transcription:

Level switches Series LC40 Float level switch for liquids Simple and robust construction Versatile and easily adaptable to the different control positions of the industrial processes Side or top of the tank mounting Watertight and safe installation Excellent chemical resistance Design for high pressure and temperature available Connections: EN 1092-1 DN65 flange. Other sizes and flange standards (ANSI, JIS,...) on request Materials: EN 1.4404 (AISI 316L), PVC, PP, PVDF, PTFE Level detection Options: - ATEX Ex d IIC T6 version - Extended temperature range version - Accessories for extended switching differential - Chamber for external mounting

Working principle Float level switches. When a liquid reaches the level where the level switch is positioned, its float follows the level variations in a such way that the articulated rod is moved. A magnet placed in the opposite side of this rod activates a switch. This switch can be either a micro-switch, a reed switch, an inductive detector or a pneumatic switch, depending on the application requirements. Applications Pumps start-stop Control of industrial processes Dosing and process tanks Tanks in machinery for chemical industry Level detection in tanks for food and textile industries,... Level control in tanks of steam condensates Working pressure: - AISI 316L: PN16 Up to PN400 on request - PP, PVC, PTFE: PN10 Connections: EN 1092-1 DN65 flange Other sizes and flange standards on request Special square flange 92 x 92 / 108 x 108 mm Mounting: side of the tank. On top with special models Housing: IP65 - anodized aluminium. EN 1.4404 (AISI 316L), PP, PVC, PTFE on request Accessory A21 for extended switching differential Chamber for external mounting Limit switches AMM: SPDT micro-switch AMD: inductive detector AMR: SPDT reed switch AMP: ON/OFF two-way pneumatic switch All switches can be supplied in ATEX Ex d IIC T6 version on request Materials Models LC40 LC40-BA LC40-V LC40-VR side mounting side mounting top mounting top mounting Technical data Switching differential: 52 mm Up to 1100 mm, depending on the accessories Liquid density: 0.45... 3 kg/l Liquid maximum viscosity: 3000 mpa s Liquid temperature: - LC40 / AISI 316L: -50ºC... +150ºC -50ºC... +300ºC on request - LC40 / PVC: 0ºC... 50ºC - LC40 / PP: -20ºC... 90ºC - LC40 / PTFE: -20ºC... 150ºC - LC40 / PVDF: -20ºC... 150ºC Ambient temperature: -30ºC... +80ºC Materials Nº Description AISI 316L PVC PP PTFE 1 Float EN 1.4404 (AISI 316L) PVC PP PTFE 2 Fork EN 1.4404 (AISI 316L) PVC PP PTFE 3 Flange EN 1.4404 (AISI 316L) PVC PP PTFE 4 Housing Aluminium * * Others on request 2

Level switches Series LC40 Dimensions Side mounting Model LC40 / AISI 316L Model LC40 / PP, PVC, PTFE, PVDF PN EN 1.4404 (AISI 316L) DN D g k l x nº b 16 65 185 122 145 18 x 8 18 Other sizes (minimum DN50) and flange standards (ANSI, JIS,...) on request PVC / PTFE / PP / PVDF PN DN D g k l x nº 10 65 185 122 145 18 x 4 Flanges in PVC, PTFE, PP and PVDF acc. to DIN 8063 PN10 Model LC40-BA / AISI 316L Standard dimensions H (mm) 150 200 300 400 L (mm) 250 350 450 600 Others on request (H+L maximum 1000 mm) 3

Top mounting Model LC40-V / AISI 316L Model LC40-VR / AISI 316L H max = 1000 mm Requires manhole in the tank for the installation Accessories Complement A21 Available for connection size bigger than DN65 (included) 4 H depending on L (mm) α 2β= 2α+ 27 L=400 L=500 L=600 L=700 L=800 L=900 L=1000 0 27 184 228 276 324 370 418 466 5 37 230 292 356 420 484 548 612 10 47 276 352 432 514 594 674 754 15 57 318 412 506 604 700 796 892 20 67 360 466 578 688 800 910 1022 25 77 398 520 644 770 894 1020 1144 30 87 434 568 706 844 984 1122 1260 35 97 468 614 764 914 1064 1214 1366

Level switches Series LC40 Thermal separator housing For temperature up to 200ºC. Special design for temperature up to 400ºC on request. ATEX version ATEX Ex d IIC T6 certified. Suitable for temperatures up to 300ºC. Ex d IIC T6 housing with ATEX packing gland, supplied only on request Square flange EN 1.4404 (AISI 316L) PP / PVC / PTFE / PVDF 5

Housings ALUMINIUM (standard) PVC Other materials on request: EN 1.4404 (AISI 316L), PP,... External mounting to tank or boiler In applications where it is required, an external chamber for side mounting is available as an option. 6 DN PN D k l x nº b R (BSP / NPT) Material A AD 16 115 85 14 x 4 16 160 185 25 25 115 85 14 x 4 17 160 185 AISI 316L / 40 115 85 14 x 4 18 1 160 185 Steel 64 140 100 18 x 4 18 160 205 100 140 100 18 x 4 28 165 220

Level switches Series LC40 Limit switches Switch Contact rating Protection Ambient temperature SPDT micro-switch 20 x 10 6 operations 3 A 220 VAC 0.5 A 24 VDC Inductive detector NAMUR (EN 60947-5-6) 8.2 VDC (amplifier relay on request) -25ºC... +85ºC IP65 SPDT reed switch 0.5 A 220 VAC 60 VA ON/OFF two-way pneumatic switch 2... 6 bar 0ºC... +50ºC Recommendation for the installation LC40 / AISI 316L LC40 / PVC, PP, PTFE, PVDF A = 90... 100 mm A = 70... 80 mm Note: for DN50 connection the maximum allowable PN for the flange is PN40 7

PRESENCE IN MORE THAN 50 COUNTRIES ALL OVER THE WORLD R-CT-LC40 Rev. 1 english version Tecfluid S.A. Narcís Monturiol 33 08960 Sant Just Desvern Barcelona Tel: +34 93 372 45 11 Fax: +34 93 473 44 49 tecfluid@tecfluid.com www.tecfluid.com Quality Management System ISO 9001 certified by Pressure Equipment Directive 97/23/CE certified by ATEX European Directive 94/9/CE certified by The technical data described in this specification sheet is subject to modification without notification if the technical innovations in the manufacturing processes so require.