Similar documents
Cable Length Meter INSTRUCTION MANUAL

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

INSTRUCTION MANUAL PET Fax: (503)

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

DT304. Digital Temperature Logger INSTRUCTION MANUAL

INSTRUCTION MANUAL DM5B Fax: (503)

3 PHASE TESTER & MOTOR ROTATION TESTER

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL M110A Fax: (503)

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

Non-Contact Phase Rotation Tester

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

Phase Sequence Tester

User's Manual. Earth Ground Resistance Tester. Model Introduction

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Digital/Analog Megohmmeter Model 1026

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Harvil 4 Foot Air Hockey Table

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Users Manual. Phase Rotation Indicator

Visit us at

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Harvil 5 Foot Air Hockey Table

User Guide. Model Insulation Tester / Megohmmeter. Introduction

OUTDOOR TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

ROTARY HEAD DIGITAL STEM THERMOMETER

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Air Compressor. Owner s Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Installation Instructions Receiver Rack (Part # 7700) Universal Application

OCTA FLUORESCENT 7 SOCKET FIXTURE

Harvil 4 Foot Air Hockey Table

CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

OPERATING INSTRUCTIONS

Megohmmeter Test Probe

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

VICTORY TABLE TENNIS TABLE ASSEMBLY INSTRUCTIONS

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Non-Contact Phase Rotation Tester

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

OPERATING INSTRUCTION

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

i400s Calibration Information Introduction

AC/DC Compact Charger. for Digital Camera and Camcorder Batteries. Owner's Manual. Please read before using this equipment.

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Instruction Manual. Model 310 Digital Milli-Ohm Meter

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

CYCLONE DR Bolt PP-400BP Battery Pack for PP-400DR Portable Power Pack

PY-11 Voltage & Continuity Tester

KMP Insulation-Continuity Tester. Users Manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

OPERATING INSTRUCTION

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

steady cool fluorescent IUF-55 INSTRUCTIONS

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Questions or Concerns? Please contact us Mon - Fri 9:00AM - 6:00PM PST at (888) or Natural Himalayan Salt Lamp

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free


Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

HIGH VOLTAGE PROVING UNIT

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Have a Bright Day! Nicholas Harmon President and CEO

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

Installation / Operation Instructions Sunnex ORION Series Exam Lights

UNIVERSAL CHARGER FOR FS-E45R AND FS-B73R USER MANUAL FA-CH1

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

Users Manual. MegOhmMeter

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

OPERATION AND MAINTENANCE

User's Manual Digital High Voltage Insulation Tester Model

IMPORTANT SAFETY INFORMATION

712 RTD Calibrator. Instruction Sheet. Introduction

Duo Charger. for Digital Camera and Camcorder Batteries. Owner's Manual. Please read before using this equipment.

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

Instruction Manual IVT-10 / IVT-20 Voltage Tester

OWNER S MANUAL. Please read these instructions and safety precautions carefully before using this equipment.

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TIF VA500A DIGITAL HVAC ANALYZER

12-in-1 CABLE TESTER. User Manual CBT-12

16 Inch Hanging Pendant Barn Light

Transcription:

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Introduction Descriptions All the information you need in one device. Verify correct wiring to avoid damage. Use the PSMR1 to check supply line phase orientation for devices such as scroll compressors or motors. Works on 45-70 Hz and on voltages between 100 and 600 VAC. Five indicators give you information about open phases, and indicate the sequence of the three lines. Use the motor rotation tester side of the meter to verify the rotation direction of the motor shaft. Note: Follow all warnings to ensure safe operations. 1 3 2 Safety Notes Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise the protection provided by the meter may be impaired. Rated environmental conditions: 1. Indoor use. 2. Installation Category III. 3. Pollution Degree 2. 4. Altitude up to 6560 feet (2000 meters). 5. Relative humidity 80% Max. 6. Ambient temperature 32-104 F (0-40 C). Observe the international electrical symbols listed below: Meter is protected throughout by double insulation or reinforced insulation. WARNING! Risk of electric shock. CAUTION! Refer to this manual before using the meter. Alternating current. 5 7 1. Phase rotation input terminal 2. Open phase indicator 3. Phase rotation indicator 4. Motor tester power switch 5. Motor tester power indicator 6. Motor rotation indicator 7. Motor rotation input terminal 4 6 Features Three functions in one unit including open phase, phase sequence and motor rotation indication. This model is ideal for installing conveyor lines, pump systems and interconnected drivers. Identifies 3-phase sequence and open phase check. Battery operated. Meets EN61010-1 safety requirements. Complete with three large alligator clips. Measuring Methods Operations 3 phase rotation tester: 1. Connect the test lead to 3-phase input terminals by R-S-T. 2. Connect color alligator clips to the terminals of a 3-phase power source. Connecting order may be optional. 3. Make sure that all of the three lamps for open phase check are on. If so, there is no open phase. When any of the three lamps, there is open phase. PSMR1-MAN P. 1

Open phase check lamp "R" terminal where RED alligator clip is connected Open phase check lamp "S" terminal where YELLOW alligator is connected Open phase check lamp "T" terminal where BLUE alligator clip is connected 4. Check the rotating direction of the rotation indicator if: Lamp of counter clockwise is lit Lamp of clockwise is lit Alternate the connection of two of the three alligator clips Phase sequence is R, S, and T in order of the power source terminals where the RED, YELLOW and BLUE alligator clips are connected 4. If you require the motor to rotate counter clockwise, you should change connection to L2 - L1 - L3, the motor should now rotate counter clockwise. Specifications (Fig 1) Operating motor rotation tester: 1. Make sure there is no voltage present. 2. Connect the test lead to motor input terminal by L1 - L2 - L3, and press the power button (Fig 1). The power indicator green lamp is lit. (If red lamp of clockwise or counter clockwise is lit before rotating the motor shaft, it means there is voltage present. Please stop measuring, take off the test leads and turn off the external power). If red lamp is lit while rotating the motor shaft clockwise, it means 3-phase motor connection to the power supply by L1 - L2 - L3, the 3-phase motor will rotate clockwise. 3. Connect the lead to 3-phase motor by L1 - L2 - L3, and press the power button on. The power indicator green lamp is lit. Rotating the motor shaft counter clockwise. If red lamp of counter clockwise is lit. it means 3-phase motor connection to the power supply by L1 - L2 - L3, the 3-phase motor will rotate clockwise. Input Voltage: Frequency Range: Circuit Structure: Power Requirement: Power Consumption: Installation Category: Dimension: Accessories: Test leads (red, yellow and blue), soft carrying case, instruction manual PSMR1-MAN P. 2 Weight: 100V AC up to 600V AC max 45 to 70 Hz All electronic (not mechanical) DC 9V alkaline battery Consumption current approx. 14mA of motor rotation field of tester. AC power consumption approx. 7mA per phase rotation field of indicator. EN61010-1 600V CAT III 6.02" (L) x 2.83" (W) x 1.37" (H) 153mm x 72mm x 35mm Approx. 182g including battery

Maintenance Battery Replacement: 1. It is necessary to replace battery, when green lamp is dull. 2. Use a screwdriver to unscrew the screws on the back. Open the case (Fig. 2), take out the battery and replace with new b a t t e ry type (DC 9V alkaline battery ). 3. Reinstall the case. Fuse Replacement: 1. It is necessary to replace the fuse when the lamp indicator R or T show no connection and change R-S-T is the same. 2. Use a screwdriver to unscrew the screws on the back. Open the case (Fig. 2), take out the damaged fuse and replace with a new fuse (200mA, 250V). 3. Reinstall the case. (Fig 2) Cleaning and Storage: WARNING! To avoid electrical shock or damage to the meter, do not get water inside the case. Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the battery and store them separately. PSMR1-MAN P. 3

PSMR1 Phase Sequence & Motor Rotation tester Limited Warranty The PSMR1 is warranted to be free from defects in materials and workmanship for a period of three years from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UE i s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warra n ty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when repairable) for a service charge. Return the unit postage paid and insured to: This warranty gives you specific legal rights. You may also have other rights which vary from state to state. 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PLEASE RECYCLE Copyright 2007 UEi PSMR1-MAN 1/07