ABB Transformers Egypt

Similar documents
Distribution transformers Efficiency over life-cycle

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

MEDIUM POWER TRANSFORMER

INESING GROUP. Power System Solution

ABB Ltd. FACTORY IN HANOI

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

The African Medical Market Fact Book 2012

TGK Prefabricated Substation Technical Data

TRANSFORMERS UP TO 750 kv

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

History of the company. TUMETIC and TUNORMA: Tailor-Made Technology

Key features. DESIGNS: - Conservator type - Hermetically sealed

A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY

AFRICAN REFINERS ASSOCIATION. Specifications Workgroup Report: ARA AGM Cape Town March 2008

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

T6-PLAN HYGIENE CENTRALLY CONNECTED RADIATOR.

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

GENERAL SECRETARIAT DECEMBER 2009

COMPACT SUBSTATION GUIDE

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

PRESENTATION ON STANDARDSDISTRIBUTION TRANSFORMERS BUREAU OF INDIAN STANDARDS BHOPAL

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Investigation Nos: 332-TA-542 and 332-TA-544

The Spot Market in the Southern African Power Pool and Impact of Demand Side Management Options. Alison Chikova Chief Engineer (SAPP) 28 May 2015

CAST RESIN TRANSFORMERS

3rd Meter Gauge Group CEO s Conference. Brisbane. 10 May, rd Meter Gauge CEO's Conference in Brisbane - 10th May,

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

SECTION PADMOUNT TRANSFORMER - OIL FILLED

GLOBAL ECONOMIC PROSPECTS January Statistical Annex

Quality Reliability Flexibility. Trasformatori di potenza in olio Oil Transformers

The Little Data Book. Africa. From Africa Development Indicators. Human development. Basic indicators. Agriculture, rural development, and environment

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

Transformers Global product offering

Transformers for Power Applications

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Howard Industries. Single-Phase Step

Standard Features and Accessories

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

DISTRIBUTION TRANSFORMERS CATALOGUE

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Transformer bushings, type GOH. Technical guide

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

/ I S S : / S T S I

International Sugar Organization WORLD SUGAR BALANCES 2002/ /16

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

Enhancing data tracking for evidence based programming

Powering industry since 1947.

Business Edge. Global Leadership

Technical Specification of GECOL. Packaged Transformers

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Transformer Components & Accessories

SPECIFICATION SS-52/15 8 MVAR 25 MVAR, 157.5kV SHUNT REACTORS

DRY TYPE TRANSFORMERS

GAS INSULATED VOLTAGE TRANSFORMERS.

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

LPI ranking and scores, 2014

On-Load Tap changer Type V

Large Power Transformers

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

Design specifications

ÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a

TRANSPORT. Take all the necessary precautions to prevent the load from knocking against the vehicle during transport. - 1/5 -

The construction features of EdM transformers

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Green: 348. Yellow/Orange: Yellow/Orange: Green: 348. Yellow/Orange: Green: 348. Yellow/Orange:137 Bronze: 145

Dry type transformers for safety, reliability and environmental impact for F&B

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

Bushings for High Voltage AC Applications

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

Country Risk Scores Table Results

Table 19 Production, trade and supply of other kerosene Thousand metric tons and kilograms per capita

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

BHATINDA CERAMICS PRIVATE LIMITED (Mfrs/Exporters of High Tension Porcelain Insulators)

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

NEW Solutions for Underground System Growth

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

Transcription:

Kamel Elhamy, 2013 ABB Transformers Egypt Our transformers support the systems that keep our world running ABB January 31, 2012 Slide 1

Factory Information Key data 2012 Annual volume 40 MUSD Employees 135 Total Close Area Total Area 7,500 m2 20,000 m2 Line Capacity Units MVA Average kva SDT ( 315 kva ) 900 150 160 MDT ( 316 2499 kva ) 3000 1900 630 LMDT ( 2500 5000 kva ) 150 450 3000 TOTAL per year 4050 2500 January 31, 2012 Slide 2

Product scope definition SDT and MDT Rated Power Product type 50-2499 kva, Oil Immersed Distribution Transformer Cooling System voltages ONAN HV 36 kv (LI 170 AC 70) LV 1,1 kv (LI - AC 3) Three legs Cold Rolled Grain Oriented (CRGO) Silicon Steel core HV multi layer,enamelled or paper insulated,cu or Al wire LV foil winding with Al or Cu foil or flat wire Strip layer insulation in MDT HV winding Winding on the core leg Corrugated type tank Hermetically Sealed or Conservator Type Pole mount for SDT, Ground mount for SDT and MDT January 31, 2012 Slide 4

Product scope definition SDT and MDT Standard equipment included Optional equipment Conservator type Off-circuit tap changer in 5 pos equipment High and low voltage porcelain bushings acc to DIN standards Top cover mounted Thermometer pocket Lifting lugs Earthing terminals Rating plate Drain /Sampling device Pressure relief device (for hermetically sealed ) Bi-directional rollers (for ground mount) Silica gel breather Oil level indicator without contacts Buchholz relay: 630-2499 kva Optional Oil level indicator with 1or 2contact Buchholz relay <630 kva Plug in bushings on HV Flat Bars bushings on LV Side mounted bushings on LV 7 pos Off-circuit tap changer Oil Level Indicator Dial type thermometer (with contacts) Pressure relief device (with contacts) Multi protection device (DGPT 2 or similar) Air filled cable boxes Terminal box Painted in alternative RAL colors Alternative loss combinations On special request and dependent of design department loading HV dual voltage HV / HV transformer January 31, 2012 Slide 5

Product scope definition LMDT Rated Power 2500-5000 kva Oil Immersed Hermetically Sealed or 2500-3150 kva Conservator Type >3150 kva Conservator type with radiator cooling Cooling ONAN System voltages HV 36 kv LV 12 kv Winding on the mandrel For ratings above 3150 kva Three legs Cold Rolled Grain Oriented (CRGO) Silicon Steel core HV multi layer winding, round or flat, enamelled or paper insulated Cu wire LV foil winding with Cu foil, layer winding with Cu flat wire Strip layer insulation Up to 3400 kva oval core shape, Above round core shape January 31, 2012 Slide 6

Product scope definition LMDT Standard equipment included Optional equipment Off-circuit tap changer in 5 pos High and low voltage porcelain bushings acc to DIN Top cover mounted Dial type thermometer with contacts Lifting lugs Earthing terminals Rating plate Conservator type equipment Silicagel breather Oil level indicator with one contact Buchholz relay Optional Oil level indicator with 2 contacts Plug in bushings on HV Off-circuit tap changer with max 7 pos Oil level indicator Winding temperature indicator Air filled cable boxes Skid base Terminal box Filter valves (>3400 kva) Painted in alternative RAL colors Alternative loss combinations Drain valve Pressure relief device (Hermetically sealed type) Multi protection device (DGPT 2 or similar) (Hermetically sealed type) Bi-directional rollers 2 Thermometer pockets (>3400kVA) January 31, 2012 Slide 7

Production Process- Active parts Core Manufacture L V Winding HV Winding Active Part Special Test Routine Test Oil Filling Drying process January 31, 2012 Slide 8

Production Process- Tank Rib Manufacture Spot Welding Rib Welding Final Assembly Tank Painting Cover Painting Shot blasting Leakage Test January 31, 2012 Slide 9

Testing of transformers 50-5000 kva Routine Tests TRANSFORMER TESTS ACCORDING TO IEC 60076 Measurement of winding resistance Measurement of voltage ratio and check of phase displacement Measurement of short-circuit impedance and load loss Measurement of no-load loss and current Applied voltage test Induced voltage test Special Tests Measurement of insulation resistance Measurement of zero sequence impedence Type tests Lightning impulse test Temperature rise test MECHANICAL TESTS Pressure test Paint thickness and adhesion test January 31, 2012 Slide 10

Green Transformer Program- BIOTEMP ABB Transformers Egypt participated in Cairo exhibition Electricx 2011 with its produced BIOTEMP 500 kva 22/0.4 KV. Indicating the following advantages : 1- BIOTEMP is human and nature friendly 2- BIOTEMP can withstand cont. over load 10 % starting from full load without more cooling. 3- BIOTEMP fire point temperature is more than 300C. January 31, 2012 Slide 11

New Painting System Shot blasting Oxsilian pretreatment Powder Primer Powder Top coat New electrostatic painting line by Q2 to improve external view Existing painting System Flow coat painting Standard Colour RAL7035 Overall thickness 80-120 microns January 31, 2012 Slide 12

Quality Management ISO 9001:2008 Quality ISO BS OHSAS 18001:2007 Operational Health & Safety ISO 14001:2004 Environment January 31, 2012 Slide 13

Export Reference List Algeria (O&G Utility) Libya Sudan Djibouti (Utility) Ivory Coast Senegal Togo Benin Ghana Burkina Faso Nigeria Cameroun Gabon (Utility) Uganda (Utility) Kenya Rwanda Tanzania DR Congo (Utility) Angola Zambia (Utility) Botswana Mozambique January 31, 2012 Slide 14

January 31, 2012 Slide 15