Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Similar documents
Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Installation and Start Up Instructions

Installation and Start-Up Instructions

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

INFINITY ZONING QUICK START GUIDE

Design Guide INTRODUCTION

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Digital Room Thermostats with Touch Screen LCD

Product Data. Infinity 18 38TDB (60 Hz) Two-Speed Air Conditioner with Puron Refrigerant. Sizes 024, 036, 037, 048, and 060 FEATURES/BENEFITS

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Installation Instructions

Product Data. S Up to 19 SEER / 13 EER S Microtube Technologyt refrigeration system Sound

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Installation Instructions

SetPoint 501 and 501s Controllers Installation and Operation Manual

SE8300 Series Installation Guide 24 Vac Low Voltage

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

BAPI-Stat 3 Room Sensor

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Lester Electrical ChargerConnect App User s Guide

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Silver Series Thermal Dispersion Airflow Measurement Technology

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

Installation Instructions

Cooling Capacity CFM in. w.c. (125 Pa)

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

OTEC Transfer switch open transition

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Installation Instructions

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

2011 International Comfort Products, LLC

Orchestrate your entire home from a single interface. The beauty of interoperability.

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Metasys Zoning Package Installation

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

COIL WINDING TECNHOLOGY LINE. Advanced High-Tech Solutions for Coil Winding Process Control

GMS9/GCS9 SERIES 93% AFUE

Smart Wi-Fi Sprinkler Timer and Flow Meters

Metasys Zoning Package

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

Description. functions including single duct pressure dependent or pressure independent systems.

Orion BMS Purchasing Guide Rev. 1.2

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Installation Instructions

CONNECTED SERVICEs TACHOGRAPH SOLUTIONS

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

BAC Custom Engineered Controls

Product Data. 24ANB7 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

ZoneTouch V2 Zone Control System Installation Manual

SMT-150 Installer Manual

Cooling Capacity CFM in. w.c. (125 Pa)

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

SLIMZONE CLASSIC /

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

CONSTANT PRESSURE CONTROLLERS

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

GE Measurement & Control

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Installation Instructions

VisionPRO 8000 Thermostats

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Product Data. Infinity YDB (60 Hz) Two-Speed Heat Pump with Puron Refrigerant. Sizes 024, 036, 037, 048, and 060

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

EVlink Parking charging stations. Simpler for drivers. Smarter for your city.

MS Application. Features. Proportional Valve Actuator General Instructions

Direct Gas-Fired Heating

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

Installation Instructions. Y-Series Brushless Servo Motor

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Transfer switch OTEC and OTECSE open transition

Transcription:

SYSTXCCITC01---B Infinityr System Control Product Data A11577 NOTE: Infinityr System Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452, pointsett U.S. Pat No. 7,415,102 INFINITYR SYSTEM CONTROL Carrier specializes in creating a customized home comfort system tailored to your needs with our broad selection of residential heating and cooling products. The Infinityr System Control is the ultimate control center for all of your system components. When you add an Infinityr System Control to a compatible variable speed furnace, fan coil, Infinityr System split or package unit, or small packaged product, you will enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home. By adding a variable speed, multi-stage, or 2 -stage outdoor unit, you will enjoy extra benefits which include better humidity and temperature control as well as a more energy efficient comfort system. When paired with Infinity r Zoning controls, the Infinityr System Control allows you to create up to 8 zones of customized comfort. The Infinityr Zoning system does not require a bypass damper, leaving air temperature (LAT) sensor, or field -installed power transformer. Always install the latest version of software to enable all features of the system. Over-the-Air software updates for Wi-Fi models connected to the Infinity server are automatically downloaded. Software updates via MicroSD are available on HVACpartners, or at www.myinfinitytouch.com. Wi --- Fir is a registered trademark of Wi---Fi Alliance Corporation. INDUSTRY LEADING FEATURES/BENEFITS Carrier s revolutionary Infinityr System Control is the smart control of the future. Its unique system self-configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call -backs. The Infinityr System Control features a high resolution display, making it easier to read. Intuitive prompts let you program everything from humidity levels to fan speeds, giving you the ultimate control over your home comfort. Other features include: 2 -wire connection to Infinityr System two or more -stage outdoor equipment (including geothermal split units) 4 -wire installation from each major component in the system Infinityr Zoning System compatibility Occupancy sensing to provide comfort when spaces are occupied; schedules can maximize energy savings Intuitive on screen prompts for ease of installation and service Ideal Humidity Systemt settings are the default; no longer requiring increased system setup Complete integration of the temperature, humidity and ventilation in every season Auto mode selection to satisfy simultaneous heating and cooling demands via more aggressive Auto Changeover algorithm - -installer must enable 7 -day programmability with Lifestyle Comfort Profiles and Touch -N -Gor features; complies with California Title 24 programmability requirements Easy timed -override schedule Simplified vacation schedules Day -at -a -glance programming for simplified ease of use Programmable fan by period TrueSenset Dirty Filter Detection Indoor Air Quality pop up reminders General maintenance reminder messaging Wi-Fir remote access capability (SYSTXCCITW01 -A & SYSTXCCITC01 -A models) Upload photo, dealer info, and software updates locally via MicroSD card. Software updates available automatically when connected to the Infinity web server Compatible with home automation through the SYSTXCCRCT01 or SYSTXCCRWF01 system access modules, or via Amazon Alexa control Compatible with communicating Infinityr System Small Packaged Products Compatible with Infinityr System geothermal products (GC and GZ models). Energy Tracking feature for geothermal systems is available with Entering Water Temperature sensor installed in heat pump)

MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 S Y S T X C C I T C 0 1 -- B Product Type Infinityr System Version B Brand Carrier 01 Packaged Quantity Model Type ITC --- Infinityr System Control with Wi --- Fi Fig. 1 - Unit Dimensions A170101 2

PRODUCT DATA INFORMATION Compatible Communicating Products Compatible with most Infinityr System indoor and outdoor equipment built since 2004; see equipment specifications for details. Home Automation System Interface A cloud -to -cloud Open API (Application Program Interface) is available for the ITC and ITW model Infinity Touch and Infinity System Controls. See the Infinity Systems Open API Getting Started Guide available on www.hvacpartners.com or contact InfinityOpenAPI@carrier.utc.com for more information. The Infinityr System control may also connect to a variety of Home Automation systems using SAM modules. Note that not all Home Automation systems may be compatible. Reference the latest version of the Application Specification titled SAM Remote Access Application Specification, available on HVACpartners.com to learn more about the latest Home Automation interfaces to the Infinityr systems. Work with the home automation supplier to see if the systems are compatible. If not, you may provide the Infinity System Open API Getting Started Guide or the SAM Remote Access Application Specification to the home automation supplier to develop an interface with the Infinityr System. Always be sure to obtain the latest version of the application specification from HVACpartners, as we continually update and add home automation interfaces. NOTE: The ability to remotely access and adjust the settings of the Infinityr System Control with the MyInfinity web and mobile applications is dependent on the compatibility of the user s computer, home network and/or mobile device, the Infinityr System Control, and/or the MyInfinity web server or other system interfaces with, and the availability of, the user s internet service provider or mobile device carrier service. Carrier Corporation makes no representations or warranties, express or implied, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose or use, about the compatibility of the user s computer, home network, and/or mobile device, with the Infinityr System Control, and/or the MyInfinity web server or other system interfaces, with, and the availability of, the user s internet service provider or mobile device carrier service, or that the ability to remotely access and adjust the settings of the Infinityr System Control will not be negatively affected by the network -related modifications, upgrades, or similar activity of the user s internet service provider or mobile device carrier service. Physical Characteristics Dimensions: See drawing Appearance: Black glass front, silver plastic body Electrical Characteristics/Communication Input Volts/Amps 24VAC Each device in the Infinityr System has a four-pin connector labeled ABCD. It is recommended that the following color code be used when wiring each device: A Green = Data A+ B Yellow = Data B - C White = 24VAC (Com) D Red = 24VAC (Hot) Always verify that the IDU and ODU are well-grounded, and that there are less than 10 volts AC/DC as measured between the cabinets of the IDU and ODU, while the equipment is operating at full capacity. If there is a larger voltage difference between the cabinets of the IDU and ODU, recheck the equipment grounding. Environmental Requirements: Operating Temperature/Relative Humidity: User interface and all sensors: 32_F to 104_F / 0_C to 40_C, 95% RH non -condensing Feature Specifications: Temperature set point range: 50_F to90_f / 10.0_C to 32.0_C Separate heat and cool setpoints Programming days: 7 day Programming periods: Up to 5 periods per day Advanced Smart Setback (with programming) Touch -N -Gor feature Occupancy Sensing Non -Programmable (installer selectable) Auto Changeover* (may be disabled) Simultaneous Heat Cool Demand Algorithm for zoned systems Programmable fan (installer selectable) Humidity Sensor Offsets Auto Changeover Timer (installer adjustable) Smart Recovery (in heating and cooling) Hold function Copy functions: copy day of week; copy zones Permanent memory Humidity display and control Temperature sensor offsets (indoor and outdoor) TrueSenset Dirty Filter Detection with compatible indoor equipment * See Installation Instructions for details on Auto Changeover and Simultaneous Heat/Cool Demand Algorithm operation. Wiring Requirements: Power supply: 24VAC, 40 VA (minimum), 60 Hz, via indoor equipment ABCD Connector. Zoning systems with a large number of dampers, especially multiple dampers per zone, may require a separate, dedicated, field -installed 24vac power supply. The SAM module requires an independent, isolated, field -supplied 24vac power supply. Wiring material: Standard thermostat wire 18 to 22 gauge. Use 18 AWG wiring for wire lengths over 25 feet. Shielded, twisted pair cable for te ABCD communication bus is optional, and may be helpful in electrically noisy environments, or for zoning systems with Smart Sensors. NIM Requirements: IDU NON---COMMUNICATING ODU NIM REQUIRED? Furnace 1 --- stage A/C No Furnace 2 --- stage A/C Yes Furnace 1 --- stage HP Yes Furnace 2 --- stage HP Yes Fan Coil 1 --- stage A/C No Fan Coil 2 --- stage A/C Yes Fan Coil 1 --- stage HP No Fan Coil 2 --- stage HP Yes 3

Infinityr System Control with Wi --- Fir Remote Access Capability Infinityr Network Interface Module (NIM) EQUIPMENT SYSTXCCITC01--- B SYSTXCCNIM01* * Required for ventilator control * Required for Hybrid Heat applications with non---communicating heat pumps * Required for use with 2---stage (non---communicating) AC or HP Infinityr Remote Room Sensor (RRS) ABCD Equipment Communication Connector (Green Plug; 10 pack) Decorative Trim Plate --- Gray (six pack) Decorative Trim Plate --- Black (six pack) Decorative Trim Plate --- White (six pack) Decorative Trim Plate --- Silver (six pack) Outdoor Air Temperature Sensor Infinityr Remote Access Module, Broadband Cat---5 Wired Infinityr Remote Access Module, Broadband Wi---Fir Wireless Accessory Power Transformer for SAM Modules** OPTIONAL ACCESSORIES SYSTXCCRRS01* SYSTXGRPLG10 SYSTXNNGB06 SYSTXNNBB06 SYSTXNNWB06 SYSTXNNSB06 TSTATXXSEN01---B SYSTXCCRCT01 SYSTXCCRWF01 SYSTXNNXFM01** * Not required, but may be used to remote sense indoor room temperature. { Backplate dimensions 6.83 in. (173.5 mm) wide X 5.97 in. (151.7 mm) high ** Available from RC/Totaline. Infinityr Damper Control Module (4 Zone) Infinityr Smart Sensor ZONING EQUIPMENT SYSTXCC4ZC01 SYSTXCCSMS01-B * NOTE: Each piece of the zoning equipment is purchased separately allowing for customization of the zoning application. **Smart Sensor dimensions are 3.375 in. (85mm) side x 4 in. (101 mm) high { One Damper Control Module for up to 4 zones. A second Damper Control Module is required for zones 5 8. DAMPER REPLACEMENT ACCESSORIES 45º Actuator for round dampers DAMPACT45DEG-R 90º Actuator for rectangular dampers DAMPACT90DEG-R Damper Control Module 1-amp Fuse ATO1* *Available from RC. Round Dampers Rectangular Dampers ROUND & RECTANGULAR DAMPERS 6in. DAMPRND06INC-B 8in. DAMPRND08INC-B 10 in. DAMPRND10INC-B 12 in. DAMPRND12INC-B 14 in. DAMPRND14INC-B 16 in. DAMPRND16INC-B 8in.X10in. DAMPREC08X10-B 8in.X14in. DAMPREC08X14-B 8in.X18in. DAMPREC08X18-B 8in.X24in. DAMPREC08X24-B 10 in. X 10 in. DAMPREC10X10-B 10 in. X 14 in. DAMPREC10X14-B 10 in. X 18 in. DAMPREC10X18-B 10 in. X 24 in. DAMPREC10X24-B 4

Slip-In Dampers SLIP -IN DAMPERS Side mount, 8 X 8 Bottom mount, 8 X 8 Side mount, 8 X 10 Bottom mount, 8 X 10 Side mount, 8 X 12 Bottom mount, 8 X 12 Side mount, 8 X 14 Bottom mount, 8 X 14 Side mount, 8 X 16 Bottom mount, 8 X 16 Side mount, 8 X 18 Bottom mount, 8 X 18 Side mount, 8 X 20 Bottom mount, 8 X 20 Side mount, 8 X 22 Bottom mount, 8 X 22 Side mount, 8 X 24 Bottom mount, 8 X 24 Side mount, 10 X 10 Bottom mount, 10 X 10 Side mount, 10 X 12 Bottom mount, 10 X 12 Side mount, 10 X 14 Bottom mount, 10 X 14 Side mount, 10 X 16 Bottom mount, 10 X 16 Side mount, 10 X 18 Bottom mount, 10 X18 Side mount, 10 X 20 Bottom mount, 10 X 20 Side mount, 10 X 22 Bottom mount, 10 X 22 Side mount, 10 X 24 Bottom mount, 10 X 24 Side mount, 12 X 12 Bottom mount, 12 X 12 Side mount, 12 X 14 Bottom mount, 12 X 14 Side mount, 12 X 16 Bottom mount, 12 X 16 Side mount, 12 X 18 Bottom mount, 12 X 18 Side mount, 12 X 20 Bottom mount, 12 X 20 Side mount, 14 X 14 Bottom mount, 14 X 14 Side mount, 14 X 16 Bottom mount, 14 X 16 Side mount, 14 X 20 Bottom mount, 14 X 20 Side mount, 16 X 16 Bottom mount, 16 X 16 Bottom mount, 16 X 20 DAMPSLS08X08-B DAMPSLB08X08-B DAMPSLS08X10-B DAMPSLB08X10-B DAMPSLS08X12-B DAMPSLB08X12-B DAMPSLS08X14-B DAMPSLB08X14-B DAMPSLS08X16-B DAMPSLB08X16-B DAMPSLS08x18-B DAMPSLB08X18-B DAMPSLS08X20-B DAMPSLB08X20-B DAMPSLS08X22-B DAMPSLB08X22-B DAMPSLS08X24-B DAMPSLB08X24-B DAMPSLS10X10-B DAMPSLB10X10-B DAMPSLS10X12-B DAMPSLB10X12-B DAMPSLS10X14-B DAMPSLB10X14-B DAMPSLS10X16-B DAMPSLB10X16-B DAMPSLS10X18-B DAMPSLB10X18-B DAMPSLS10X20-B DAMPSLB10X20-B DAMPSLS10X22-B DAMPSLB10X22-B DAMPSLS10X24-B DAMPSLB10X24-B DAMPSLS12X12-B DAMPSLB12X12-B DAMPSLS12X14-B DAMPSLB12X14-B DAMPSLS12X16-B DAMPSLB12X16-B DAMPSLS12X18-B DAMPSLB12X18-B DAMPSLS12X20-B DAMPSLB12X20-B DAMPSLS14X14-B DAMPSLB14X14-B DAMPSLS14X16-B DAMPSLB14X16-B DAMPSLS14X20-B DAMPSLB14X20-B DAMPSLS16X16-B DAMPSLB16X16-B DAMPSLB16X20-B 5

Copyright 2017 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231. Edition Date: 05/17 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: SYSTXCCITC-01PD Replaces: New 6