OPERATING INSTRUCTIONS

Similar documents
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

ACROBAT SWING STAND MODEL

STAND MODEL FOR MACH M2

ZB0050 / ZB0051 ZB0070 / ZB0071

ACROBAT SWING STAND MODEL

USE AND INSTALLATION HANDBOOK

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Operating instructions Accu Jet

KSZ 10B Current Probe Calibrator. Instruction Manual

Linear Luminaire with LED

Installation manual portable distributors

Installation manual wall-mounted distributor

Original Operating Manual

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Operating Instructions for Paddle Flowswitch Model: PPS-...

Assembly instructions PRORUNNER mk1 2

Pan and Tilt Head CDD2416-T

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

KSZ 100B Current Probe Calibrator. Instruction Manual

Technical Manual Electrical Power Supply System T4002

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Type 6213 EV, 6281 EV

Linear Luminaire for Fluorescent Lamps

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

INSTALLATION RULES for SCS/SENSOR Pt100

Installation and Operating Instructions. Magnetic band conveyer

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Operating instructions

Katalysator Nr /

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Operating Instructions Flexdip CYA112

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Assembly and Maintenance Manual Type ASNU

Direct Coupled Damper Actuator Model MY6050A1001

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Operating Instruction for Downlights

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating Instructions K Always on the safe side.

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Technical Documentation

Operating Instructions

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Pressure switch, high adjustability of switch differential

Product Information Overspeed governor GB 260

CONTACTS EGR VALVE TESTER 66248

GF Spin Finish Pump. Translation of the Original Operating Instruction. Edition:

Installation and Operating Instructions. Scraper conveyor version K

Operating instructions K- Control 4960, 4965, Always on the safe side.

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

Level Measuring Sensor for Diesel Fuel Tanks

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

PURE SINE WAVE DC TO AC POWER INVERTER

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Dry installed pump type LANDY BTP.

3. Operating instructions: Minor 200

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Explosion protected terminal boxes type, GHG 72.

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Operating Instructions

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Operating Instructions (Translation)

CONTENT 1 PICTURE GENERAL... 3

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Assembly and Maintenance Manual Type AS

SUBMERSIBLE WATER PUMP

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

SPARK PLUG CLEANING KIT OPERATING MANUAL

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Actuators for air dampers and control valves of oil burners

SPRING DRIVEN CABLE REELING DRUMS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Transcription:

Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS

2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been proved and the corresponding declarations and documents are deposited at the manufacturer.

Table of Contents 3 Table of Contents 1 For your own Safety...5 1.1 Intended Application...5 1.2 Symbols...5 2 Transport, Packing, Storage, and Disposal...6 2.1 Transport and Packing...6 2.2 Storage...6 2.3 Disposal...6 3 Design and Function...7 4 Technical Data...9 4.1 General Technical Data...9 4.2 Dimensions...10 5 Mounting and Dismounting...11 5.1 Scope of Delivery...11 5.2 Mounting...11 5.2.1 Mounting to a Belt Conveyor...12 5.2.2 Electrical Connection...13 5.2.3 Tightening the Release Wire...15

4 Table of Contents 6 Maintenance and Repair... 17 7 Ordering Accessories and Devices... 18 7.1 Ordering Accessories... 18 7.2 Ordering Devices... 19

1 For your own Safety 5 1 For your own Safety 1.1 Intended Application Emergency cord switches are used for emergency cutoff of continuous flow conveyors and tooling and processing machines. The emergency cord switches comply with the high requirements of the trade associations, who obligatorily stipulate emergency cut-off devices in belt conveyors for personal protection (UVV VBG 10). Applications other than specified and unauthorised modifications of the device or its components may lead to injury to persons and damage to the device for which the manufacturer is not liable. "Intended Application" means that any work performed with the device or on the device must be carried out in accordance with these operating instructions. Only qualified personnel that are familiar with the regulations for the prevention of accidents as well as the standard safety rules, are allowed to work on the device. Observing the intended application protects yourself and prevents damage to the device! 1.2 Symbols Please pay particular attention to the text passages that are marked with the following symbols: Danger! Information that must be observed under all circumstances in order to prevent the operator from being injured. Attention! Information that must be observed in order to prevent damage to the device. Helpful additional information

6 2 Transport, Packing, Storage, and Disposal 2 Transport, Packing, Storage, and Disposal 2.1 Transport and Packing Choose a suitable packing in order to prevent damage to the device during transport, or when sending devices or components to KIEPE ELEKTRIK for repair. Take great care that the device is protected against shocks and humidity. Thus, damage due to transport is prevented, for which the manufacturer is not liable. 2.3 Disposal If possible, reuse the packing material or dispose of it in an environmentally friendly way. Send the device and components to KIEPE ELEKTRIK for correct recycling or disposal (company address see back cover). 2.2 Storage Avoid significant variations in temperature that may cause the formation of condensation water, as this might damage the device. The permissible storage temperature is between 25 C and +80 C. Attention! Keep the device clean and dry.

3 Design and Function 7 3 Design and Function Emergency cord switches are used for emergency cutoff of continuous flow conveyors and tooling and processing machines. The continuous flow conveyor or the machine can be stopped at any hazardous location by means of one emergency cord switch with a range of max. 20 m. Danger! The release wire (15) should be tightened along the conveying system in such a way, that it is visible along its entire length. The emergency cord switch, type LRS 004, is a unidirectional operated switch. If the release wire (15) sags or tears off, the operation of two normally closed contacts is forced (see fig. 3-1 and 3-2). In addition, the EMERGENCY OFF command can be triggered by means of the red mushroom button (5) mounted onto the lid of the cover. If the release wire (15) is pulled, a mechanical lock is activated, which can only be released via the reset button (4) on the device. release wire (15) Fig. 3-1: Function of the emergency cord switch type LRS 004

8 3 Design and Function The current switching condition (AUS/OFF EIN/RUN SCHLAFF/SLACK) of the switch is indicated on the cover lid (2). The length of the release wire (15) depends on the local conditions, however, it may not exceed a length of 20 m. The conveying system can only be restarted after unlocking the emergency cord switch by means of the reset button (4) on the device. Danger! After triggering and before resetting the emergency cord switch, the system must be examined over the entire length of the release wire (15), in order to find out the cause of the activation of the emergency cord switch. mushroom button (5) reset button (4) SLACK OFF RUN cover lid (2) Fig. 3-2: Function of the emergency cord switch type LRS 004

4 Technical Data 9 4 Technical Data 4.1 General Technical Data Complying with the following regulations EN 60947-5-1, EN 0418, VDE 0110 contamination class: 2 (internal), 4 (external), UVV VBG 10 Suitable for Controls and plants according to EN 60204 Design AlSi Colours Cover: yellow (RAL 1004), mushroom button: red (RAL 3000), reset button: blue Fastening 4 bores for screws M 5 Permissible ambient temperature 25 C + 80 C Switching system Cam switch: 1 normally open contact, 2 normally closed contacts, forced operation Permissible insulation voltage U i AC 250 V Conventional thermal current I th 10 A Switching capacity I e /U e 2 A / AC 250 V Utility category AC 15 Protection class IP 66 according to EN 60529 Built-in position any Supply line inlet 3 threads for PG 13.5 screw connection Conductor connection housing, screw M 4 Cross section for connection max. 2.5 mm 2 Operating force approx. 190 N (preloaded force approx. 110 N) Weight approx. 630 g

10 4 Technical Data 4.2 Dimensions 80 11 48 62 69 25.5 51 85 115 3.5 37 101 7 Fig. 4-1: Dimensions LRS 004 [mm]

5 Mounting and Dismounting 11 5 Mounting and Dismounting 5.1 Scope of Delivery The emergency cord switches are delivered ready for operation without any accessories (see section 7.1 "Ordering Accessories"). 5.2 Mounting The emergency cord switches are installed to the belt conveyor structure by means of KIEPE accessories. In order to mount the emergency cord switch, the following accessories are required (see fig. 5-1 and 5-2): z four screws M 5 for fastening the emergency cord switch through the fastening bores (6) z PG fitting nut (10) z release wire (15) made of flexible steel wire (red), plastic-covered z rope tension jack (17) z egg-shaped brackets (18) z eyebolts (19) M 12 x 60 z swivel hook (20) M 10 fastening bores (6) for screws M5 swivel hook (20) eyebolts (19) rope tension jack (17) egg-shaped bracket (18) release wire (15) egg-shaped bracket (18) Fig. 5-1: Accessories for fastening the emergency cord switch to the belt conveyor system

12 5 Mounting and Dismounting 5.2.1 Mounting to a Belt Conveyor Danger! Before mounting, disconnect the belt conveyor system from the voltage supply and prevent it from being switched on again. Danger! The release wire (15) should be tightened along the conveyor in such a way, that it is visible along its entire length. Danger! Spilled material may not affect the function of the emergency cord switch. 3. Fasten the emergency cord switch by means of four screws M 5 through the fastening bores (6) in the cover (1) to the belt conveyor structure or to the machine to be monitored. Make sure that the function of the emergency cord switch is not affected by spilled material. Attention! The emergency cord switches may only be integrated into control circuits. cover (1) 101 Mount the emergency cord switch and the accessories to the belt conveyor structure as follows (see fig. 5-2 and 5-3): 1. Disconnect the belt conveyor system from the voltage supply and prevent it from being switched on again. 2. Open the cover lid (2) by loosening the four screws (7). screws (7) thread for PG cover lid (2) fitting nut (10) Fig. 5-2: Fastening of the emergency cord switch to the belt conveyor system 48

5 Mounting and Dismounting 13 4. Fasten the swivel hook (20) to the belt conveyor system or machine to be monitored. 5. Mount the eyebolts (19) that guide the release wire (15) to the belt conveyor structure. Distance between the eyebolts (19): max. 4 m 6. Fasten the release wire (15) to the rope tension jack (17) by means of an egg-shaped bracket (18). Length of the release wire (15): max. 20 m 7. Pull the release wire (15) through the eyebolts (19). 8. Fasten the release wire (15) to the swivel hook (20) by means of an egg-shaped bracket (18). 5.2.2 Electrical Connection Danger! Before starting the mounting, disconnect the belt conveyor system from the voltage supply and prevent it from being switched on again. swivel hook (20) eyebolts (19) distance: max. 4 m rope tension jack (17) fastening bores (6) for screws M5 egg-shaped bracket (18) release wire (15) Length: max. 20 m egg-shaped bracket (18) Fig. 5-3: Fastening of the emergency cord switch to the conveyor belt system

14 5 Mounting and Dismounting Attention! The emergency cord switches may only be integrated into control circuits. Attention! In order to maintain the protection class IP 66, the PG fitting nuts must be sealed very effectively. Connect the emergency cord switch as follows (see fig. 5-4 and 5-5): 11 21 Normally Open Safety Contact Normally Open Safety Contact 12 22 1. Before mounting, disconnect the conveyor system from the voltage supply and prevent it from being switched on again.. 2. Screw in one PG fitting nut (10) into one of the three threads of the emergency cord switch. 3. Pull the connection cable through the PG fitting nut (10). 4. Connect the cable to the terminals according to the connection diagram: Open contacts: connections 11/12 and 21/22 closed contacts: connections 33/34 5. Tightly fasten the PG fitting nut (10). SLACK setting field (11) Fig. 5-4: 33 34 Normally Closed Auxiliary Contact Electrical connection Contact designations reset button (4) Fig. 5-5: cover lid (2) RUN OFF Connecting the emergency cord switch Thread for PG fitting nut (10)

5 Mounting and Dismounting 15 6. Set the reset button (4) into position AUS/OFF. 7. Close the cover lid (2) and fasten it by means of screws. 5.2.3 Tightening the Release Wire Danger! Before mounting, disconnect the conveyor system from the voltage supply and prevent it from being switched on again. Danger! The release wire (15) should be tightened in such a way, that it is visible along its entire length. Tighten the release wire (15) as follows (see fig. 5-6 and 5-7): 1. Preload the emergency cord switch by means of the rope tension jack (17) or the swivel hook (20), until the black markier in the setting field (11) is positioned between the two arrows. swivel hook (20) rope tension jack (17) release wire (15) Fig. 5-6: Tightening the emergency cord switch

16 5 Mounting and Dismounting 2. Set the reset button (4) into position EIN/RUN. 3. Forcefully pull the release wire (15). The reset button (4) must jump into position AUS/OFF. Trigger the emergency cord switch several times. 4. Check the tension of the release wire (15) in the setting field (11). If the marker is not set between the two arrows any more, repeat the tightening of the release wire (15) according to step 1. The emergency cord switch is properly loaded and ready for operation after switching on the voltage supply. setting field (11) TENSIONED SLACK RUN reset button (4) cover lid (2) OFF Fig. 5-7: Setting the emergency cord switch

6 Maintenance and Repair 17 6 Maintenance and Repair The emergency cord switches type LRS 004 are maintenance-free. Defective devices can be sent to KIEPE ELEKTRIK for disposal (company address see back cover).

18 7 Ordering Accessories and Devices 7 Ordering Accessories and Devices 7.1 Ordering Accessories With every purchase order, please quote (company address see back cover): 1. Order text for accessories e. g. eyebolts M 12 x 60 2. Order number e. g. 94.045 727.001 fastening bores (6) swivel hook (20) eyebolts (19) rope tension jack (17) egg-shaped bracket (18) release wire (15) egg-shaped bracket (18) Fig. 7-1: Accessories

7 Ordering Accessories and Devices 19 Item Order text Order number 15 Release wire, red, flexible steel wire, plastic-covered (available in rools of 50, 100, or 500 m) 3mm 5mm 17 Rope tension jack (metal, 1 hook, 1 eye) 18 Egg-shaped bracket for release wire 3mm for release wire 5mm 19 Eyebolt M 12 x 60 M 12 x 200 94.045 731.001 94.045 731.002 215.22.80.02.01 94.047 869.001 94.047 869.002 94.045 727.001 94.045 727.002 20 Swivel hook M 10 94.045 728.001 7.2 Ordering Devices With every purchase order please quote (company address see back cover): 1. Type designation of the emergency cord switch (s. rating plate on the cover lid): LRS 004 2. Device identification number (s. rating plate on the cover lid): 93.046 690.004

KIEPE ELEKTRIK GmbH & Co. KG z Bublitzer Straße 28 z D-40599 Düsseldorf Tel.: +49 (0) 211 74 97 0 z Fax: +49 (0) 211 74 97 300 Internet: http://www.kiepe-elektrik.com z E-Mail: Info@Kiepe-Elektrik.com Doc.-Ident-No.: 94.056 003.191 Edition: 31.01.2000 Modification-Index: Copyright reserved Subject to changes