Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. DATE INSTALLED: DEALER:

Similar documents
Pre-Delivery Instructions

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners.

Spa Location and Preparation 4-5. Wood or Synthetic Deck Installation 6. Delivery Access Backyard Delivery 7. How To Measure For Backyard Delivery 8

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

Owner s Manual. Important!

PRE-DELIVERY GUIDE 2011

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

Pre-Delivery Guide.

LTR , Rev. P 1/14/15

saratoga spas ADVANCE DELIVERY GUIDE Key steps to making the delivery and installation of your new spa smooth and hassle-free

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

INSTALLATION INSTRUCTIONS

VPL-SH1 Vertical Platform Lift

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

Buyers Guide. You Deserve It. Helping You Find The Perfect Hot Tub!

INSTALLATION AND OPERATING INSTRUCTIONS

CHAPTER V RESIDENTIAL WIRING

COMMERCIAL QUICK REFERENCE

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

PRE-PLUMBED SEWAGE SYSTEM

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

A Homeowner s Guide to Natural Gas Service

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

LT Charging Cart for Laptops

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SECTION VII METERING INSTALLATIONS

Placement on the fireground simply refers to how and where an apparatus is placed at the scene.

IntelliTouch Pool and Spa Control System Load Center and Power Center

poollux Power plx-pw60 & plx-pw100

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

10 Commercial, Industrial, Agricultural Services

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

INSTALL SERVICE- ENTRANCE SYSTEMS

8300 Series Installation Guidelines

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Installation Manual. For. PWC 3000 Boat Lifts

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

Installation Manual. For. Trident Boat Lifts

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

WSB clean: Installation Manual

Service Requirements

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Electric Vehicle Charging Station

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Technical Manual. DLM Module. This manual should remain with the unit.

WARNING. Important Notice

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

CLEAN POWER TM CPS Series Operator s Manual

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Contents. Delivering your Canadian Spa. Pre-Delivery Guide.

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

PART B BRAND SPECIFIC MANUAL

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Kompensator External Low Voltage Heating Cable System

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

Cetra Assembly Instructions

ALL PURPOSE CNC/HEAVY DUTY

DELTA PLANNING GUIDE. Straight Inclined Platform Lift. Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 CAN/CSA B m Part No.

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections. Minnesota North Dakota South Dakota

Metering and Service Installation:

OMEGA PLANNING GUIDE. Curved Inclined Platform Lift. Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 CAN/CSA B m Part No.

INSTALLATION M ANUAL

Harding Steel Tri-Lift

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

1021 REFUSE AND RECYCLING STANDARDS FOR COMMERCIAL, INDUSTRIAL, AND MULTIFAMILY DEVELOPMENTS

PRE-INSTALLATION GUIDE

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

MASTERsine Inverter PXA Series Installation Guide

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Public Works & Utilities Department Memorandum

Automated Trash and Recycling Collection System

Installation Manual. Rev

BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Instruction & Owner s Manual

Inst all a ti o n and Oper a tin g Instru c ti o n s

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

MODEL H INSTALLATION INSTRUCTIONS

Home Elevator. Planning Guide

Code Complaint Type Section Violation description and Corrections required

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Transcription:

HIGHLIFE COLLECTION Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Pre-Delivery Instructions Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements. Remember to carefully review the Owner s Manual that accompanies your spa, and to register the spa's warranty within 10 days of delivery. These items, along with other valuable information, will be found in the Owner s Package which has been placed in the equipment compartment of your spa, where you will also find its serial number. Watkins Manufacturing Corporation reserves the right to change features, specifications and design without notification and without incurring any obligation. DATE PURCHASED: DATE INSTALLED: DEALER: ADDRESS: TELEPHONE: In most cities and counties, permits will be required for the installation of electrical circuits or the construction of eterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your Hot Spring spa is equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers and as a result, is usually eempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your Hot Spring dealer can provide information on which permits may be required. Hot Spring Spa Pre-Delivery Page Instructions

Site Selection and Preparation IMPORTANT: Site selection and preparation are your responsibility. Carefully read these instructions and consult your authorized Hot Spring dealer if you have any questions. You probably have a spot picked out for your new spa, whether it s indoors or outdoors, on a patio or on a deck. Just make sure you check the following: certain that the location you choose can support the weight of your filled spa. Manual.) where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house s circuit breaker. switch on the end of the power cord (115 volt models). or into the electrical outlet that your spa is plugged into. Your 115 volt Hot Spring spa will come with a is raintight when installed correctly with the door closed. OUTDOOR AND PATIO INSTALLATION No matter where you install your new spa, it s important that you have a solid foundation to support it. Structural damage to the spa resulting from incorrect installation or placement on an inadequate foundation is not covered under the spa s limited warranty. If you install the spa outdoors, a reinforced concrete pad at least four inches thick is required for the Vista and Grandee spas, and recommended for the Envoy, Vanguard, Sovereign, Aria, Prodigy and Jetsetter spas. The reinforcing rod or mesh in the pad should be attached to a bond wire (see your Owner s Manual). All Hot Spring spas may be installed onto a deck, provided that the load capacity of the deck is greater than the dead weight of the spa (see Deck Installation). If you place the spa on the ground, even temporarily, place stepping stones under the leveling areas (see Spa Leveling Instructions in your Owner s Manual). The stones should be at least two inches thick and twelve inches. Even with stones in place, the spa will inevitably settle and become unlevel. Plus, a spa surrounded by dirt or grass will soon be filled with dirt or grass from users feet; therefore, it is important to get it onto a solid foundation as soon as possible. DECK INSTALLATION To be certain your deck can support your spa, you must know the deck s maimum load capacity. Consult a qualified building contractor or structural engineer before you place the spa on an elevated deck or indoors. To find the weight of your spa, its contents and occupants, refer to the Spa Specification chart. This weight per foot must not eceed the structure s rated capacity, or serious structural damage could result. INDOOR INSTALLATION Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa, it is recommended that a floor drain be installed. The humidity will naturally increase with the spa installed. Water may get into woodwork and produce dryrot, mildew, or other problems. Check for airborne moisture s effects on eposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed. Your Hot Spring dealer can help you with local information such as zoning regulations and building codes. Pre-Delivery Instructions Page

DELIVERY ACCESS First, locate the dimensions of your spa on the following chart. The dimensions shown are the measurements of the spa in the vertical position, laid on its side. Net, contact your dealer to find the height and width added by the delivery cart which the dealer will use to deliver your new spa. Use the height of the cart plus the dimension shown as H to determine the vertical clearance required to pass the spa and cart. Use the width of the cart, or dimension W, whichever is greater, to determine the maimum width of clearance necessary. NOTE: It may be necessary to allow for additional over-head clearance if the spa will be rolled up or down an incline or moved up or down a short flight of stairs. Use the information below to determine the requirements for access to your desired location. Model Width W Length L Height H Vista (SS) 38 8 4 7 7 Grandee (GG) 38 8 4 7 7 Envoy (KK) 36 7 9 7 5 Aria (AR) 36 7 3 7 3 Vanguard (VV) 36 7 3 7 3 Sovereign (II) 33 7 9 6 8 Prodigy Jetsetter How is your width clearance? BACK YARD Check all gates Protruding electric meters Gas meters A/C units Do you have sufficient overhead clearance? Check low roof eaves, overhanging branches, rain gutters Is the path clear? HOUSE Move away branches, dog houses, firewood, etc. If there is a 90 turn, can we clear it? (The spa will not bend) No more than 6 consecutive stairs without a landing STREET Page 3 Pre-Delivery Instructions

It may be necessary to remove a gate, part of a fence, or other movable obstructions in order to roll the spa to its installation site. About ten percent of the time, a crane is the only way to install the spa by lifting it to its final destination. If the spa has to be taken off of the cart to go over a wall (either because the entry area is too narrow, the eaves are too low, the corner is too tight, or the stairway is too steep), a crane will be required. Don t be alarmed! The crane has a truck-mounted boom which can fit right in your driveway. It is run by a licensed and insured operator. For a charge, the crane operator will lift your spa over walls, buildings, or any other obstruction and place it as close to the installation site as possible. The Hot Spring spa delivery personnel will supervise the crane delivery and complete the spa installation. Crane delivery typically takes an average of 30 minutes to complete. NOTE: If your spa delivery requires the use of a crane, you may be required to pay for its services at the completion of the delivery. GROUND PREPARATION Your Hot Spring spa has been engineered to perform on all kinds of common yard surfaces. While a concrete slab is best for long-term use*, other foundations are acceptable so long as a level base is prepared prior to delivery. Three foundation base pictures, shown at right, represent eamples of alternatives to a concrete slab for spas installed without gazebos or other accessories. *NOTE: A reinforced concrete pad at least four inches thick or a deck that is able to withstand more than 115 per foot is required for the Vista and Grandee spas, and recommended for the Envoy, Vanguard, Sovereign, Aria, Prodigy and Jetsetter spas. INSTALLATION NOTES: If stepping stones or railroad ties are selected for the spa foundation, they should be placed at the designated leveling areas of your spa to maintain even distribution of the spa weight. It is important to note that soft surfaces, even when stepping stones are used to distribute the weight of the spa as evenly as possible, will still have a tendency to settle unevenly, resulting in an unlevel spa. Remember, placing the spa on grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user s feet. If you are purchasing a deck package or a gazebo with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are a few of the recommended surfaces. As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites. If you are interested in having a concrete slab, brick surface, or wood deck installed, your Hot Spring dealer should be able to suggest a qualified, licensed contractor. NOTE: In order for the spa to operate properly and the internal plumbing to drain completely, you must ensure that the spa is leveled after it has been installed. The diagrams on the following pages indicate the recommended shimming points on your spa s base support system. Your Hot Spring spa delivery crew can help you perform the procedure. FOUNDATIONS FOR SPAS ONLY (No accessories such as cover or gazebo) PEA GRAVEL OR CRUSHED ROCK RAILROAD TIES PRE-CAST STEPPING STONES FOUNDATIONS FOR SPAS WITH ACCESSORIES CONCRETE PADS BRICK SURFACES WOOD DECKING Pre-Delivery Instructions Page 4

Vista (Model SS) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 34 1/2" (87.6 cm) 38" (96.5 cm) MAIN DRAIN 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 22" (56. cm) 33" (83.8 cm) 49" (124.5 cm) 73 " (185.4 cm) 73 1/2 " (186.7 cm) 3 1/2" (8.9 cm) (Bottom view) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 24 1/4" (61.6 cm) 19" (48.3 cm) 19" (48.3 cm) 24 1/4" (61.6 cm) 91" (231 cm) 52 1/2" (133.3 cm) 42 1/2" (108 cm) 100" (254 cm) DOOR SIDE NOTE: Watkins Manufacturing Corporation requires that the Vista be installed on a minimum 4 thick reinforced concrete pad or a deck that is able to withstand more than 115 per foot. WARNING: The Vista must not be shimmed in any manner. Page 5 Pre-Delivery Instructions

Grandee (Model GG) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 34 1/2" (87.6 cm) 38" (96.5 cm) MAIN DRAIN 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 22" (56. cm) 33" (83.8 cm) 49" (124.5 cm) 73 " (185.4 cm) 73 1/2 " (186.7 cm) 3 1/2" (8.9 cm) (Bottom view) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 24 1/4" (61.6 cm) 19" (48.3 cm) 19" (48.3 cm) 24 1/4" (61.6 cm) 91" (231 cm) 52 1/2" (133.3 cm) 42 1/2" (108 cm) 100" (254 cm) DOOR SIDE NOTE: Watkins Manufacturing Corporation requires that the Grandee be installed on a minimum 4 thick reinforced concrete pad or a deck that is able to withstand more than 115 per foot. WARNING: The Grandee must not be shimmed in any manner. Pre-Delivery Instructions Page 6

Envoy (Model KK) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 32 1/2" (82.5 cm) 36" (91.4 cm) MAIN DRAIN 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 16" (40.6 cm) 22 1/2" (57.1 cm) 43 1/2" (110.5 cm) 67 1/2" (171.5 cm) 71" (180.3 cm) 3 1/2" (8.9 cm) 93" (236.2 cm) 44 1/2" (113 cm) 44 1/2" (113 cm) 18" (45.7 cm) 18" (45.7 cm) (Bottom view) UPSIDE DOWN VIEW OF SPA 21 1/4" (54 cm) 20" (50.8 cm) 20" (50.8 cm) 22 1/4" (56.5 cm) 89" (226.1 cm) DOOR SIDE 15 leveling points (place shims appro. 18 in from edge, then center middle shims). Page 7 Pre-Delivery Instructions

Aria (Model AR) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 32 1/2" (82.5 cm) 36" (91.4 cm) MAIN DRAIN ELECTRICAL KNOCKOUT SECONDARY DRAIN 21" (53.3 cm) 25" (63.5 cm) 30 3/4" (78.1 cm) 36.75" (93.3 cm) 62.0 " (157.5 cm) 65 3/4" (167.0 cm) 3 1/2" (8.9 cm) (Bottom view) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 22 1/4" (56.5 cm) 19" (48.3 cm) 16 1/2" (42 cm) 24 1/4" (61.6 cm) 87" (221 cm) 18" (45.7 cm) 18" (45.7 cm) 41 1/2" (105.4 cm) 41 1/2" (105.4 cm) 87" (221 cm) DOOR SIDE 15 leveling points (place shims at illustrated locations). Pre-Delivery Instructions Page 8

Vanguard (Model VV) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 32 1/2" (82.5 cm) 36" (91.4 cm) MAIN DRAIN ELECTRICAL KNOCKOUT SECONDARY DRAIN 62.0 " (157.5 cm) 21" (53.3 cm) 25" (63.5 cm) 30 3/4" (78.1 cm) 36.75" (93.3 cm) 3 1/2" (8.9 cm) 65 3/4" (167.0 cm) (Bottom view) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 22 1/4" (56.5 cm) 19" (48.3 cm) 16 1/2" (42 cm) 24 1/4" (61.6 cm) 87" (221 cm) 18" (45.7 cm) 18" (45.7 cm) 41 1/2" (105.4 cm) 41 1/2" (105.4 cm) 87" (221 cm) DOOR SIDE 15 leveling points (place shims at illustrated locations). Page 9 Pre-Delivery Instructions

Sovereign (Model II) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 29 1/2" (74.9 cm) 33" (83.8 cm) MAIN DRAIN 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 17 1/2" (45.1 cm) 31 1/2" (80 cm) 34.5" (67.6 cm) 58 1/2" (148.6 cm) 59 1/2" (151.1 cm) 3 1/2" (8.9 cm) 38" (96.5 cm) 38" (96.5 cm) 18" (46 cm) 18" (46 cm) (Bottom view) 23 1/4" (59 cm) 20" (50.8 cm) 20" (50.8 cm) 24 1/4" (61.6 cm) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 93" (236 cm) 80" (203 cm) DOOR SIDE DOOR SIDE 15 leveling points (place shims appro. 18 in from edge, then center middle shims). Pre-Delivery Instructions Page 10

Prodigy (Model H) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 29 1/4" (74.3 cm) 33" (83.8 cm) MAIN DRAIN 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 13" (33 cm) 14 1/2" (36.8 cm) 33 1/4" (84.5 cm) 43 1/2" (110.5 cm) 57" (144.8 cm) 3 1/2" (8.9 cm) 74" (188 cm) 15" (38.1 cm) 15" (38.1 cm) (Bottom view) 87" (221 cm) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 23 1/4" (59.1 cm) 19" (48.3 cm) 19" (48.3 cm) 23 1/4" (59.1 cm) 70 3/4 (179.7 cm) DOOR SIDE 10 leveling points (place shims appro. 15 in from edge). Page 11 Pre-Delivery Instructions

Jetsetter (Model JJ) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 25 1/2" (64.8 cm) 29" (73.7 cm) 1 3/4 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN MAIN DRAIN 58" (147.3 cm) 64" (162.6 cm) 47" (119.4 cm) 22" (55.9 cm) 28" (71.1 cm) 2 1/2" (6.4 cm) 84" (213.4 cm) 80" (203.2 cm) (Bottom view) 15" (38.1 cm) 15" (38.1 cm) 12" (30.5 cm) UPSIDE DOWN VIEW OF SPA 61" (155 cm) 65" (165.1 cm) 20 3/4" (52.7 cm) 19 1/4" (48.9 cm) 19 1/4" (48.9 cm) 20 3/4" (52.7 cm) DOOR SIDE Pre-Delivery Instructions 10 leveling points (place shims appro. 15 in from edge).

ELECTRICAL REQUIREMENTS To ensure you will have an opportunity to use your spa soon after delivery, it is very important that the required electrical service has been installed. Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY. IMPORTANT: All electrical circuits must be installed by a qualified, licensed electrician. Hot Spring spas are manufactured in two different electrical versions. The Vista, Grandee, Envoy, Vanguard, Sovereign and Aria converted to 115 volt operation. The remaining spa models, the Prodigy and Jetsetter systems. These models come standard from the factory with 115 volt heating systems; however, with the addition of 115 VOLT OPERATION REQUIREMENTS correct polarity throughout the circuit. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maimum voltage drop of 3% be used when calculating the larger wire size. NOTE: The term dedicated means that only the spa operates on the circuit. Each 115 volt model comes equipped with approimately 15 feet of usable power cord. (This is the maimum length allowed by Underwriters Laboratory.) When the spa is installed, the power cord will come out of the bottom of the equipment compartment. This receptacle, which contains an outdoor-rated, weather-resistant receptacle cover plate, will be provided to you. The single receptacle and cover plate should be installed by your electrician prior to the delivery of your spa. For your safety, when your electrician is installing the electrical outlet, it should be no closer than five (5) feet and no farther than ten (10) feet from the spa. (Reference National Electric Code 680-6a(1) and 680-41a.) WARNINGS: Do not connect your spa to an etension cord! The 115 volt GFCI switch and the receptacle must be protected from weather and landscape sprinklers they should never get wet. NOTE: If you require the services of a licensed electrician, your Hot Spring Dealer should be able to suggest one for you. Your Hot Spring spa has been carefully engineered to provide maimum safety against electric shock. Remember, connecting the spa to an improperly wired circuit will negate many of its safety features. Page 13 Pre-Delivery Instructions

230 VOLT OPERATION REQUIREMENTS spas must be wired in accordance with applicable local and national electrical codes, all electrical work must be done by a licensed electrician. NOTE: Watkins Manufacturing Corporation RE QUIRES THE USE OF A SUBPANEL TO SUPPLY POWER AND PROTECT THE SPA. On the Vista, Grandee, Envoy, Vanguard, Sovereign and Aria models, the subpanel and Jetsetter models, the subpanel containing GFCI breakers must be purchased separately and can be purchased from your Hot Spring dealer. A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the subpanel, and from the sub-panel to the spa per the appropriate wiring diagram as illustrated below. the spa but it should not be closer than five (5) feet from the spa water edge (NEC 680-38 to 41-A-3). INSTALLATION NOTE: After the spa has been installed by the dealer s delivery crew, your electrician can connect Control Bo and then complete the wiring connections in the control bo. IMPORTANT NOTE: Three different wiring diagrams are shown: one for Vista, Grandee, Envoy, and Aria models. One for Vanguard and Sovereign models, and one for Prodigy and Jetsetter models. Always follow the wiring diagram for your specific model. NOTE: the Owner s Manual and with each sub-panel, which can be obtained from your dealer. WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and will void the warranty. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maimum voltage drop of 3% be used when calculating the larger wire size. Vista (Model SS), Grandee (Model GG), Envoy (Model KK) & Aria (Model AR) WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. ** See owner s manual or control bo schematic for electrical connection details. GRD System Ground Terminal NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker. *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. Pre-Delivery Instructions Page 14

Vanguard (Model VV) and Sovereign (Model II) WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. HEATER GROUND 230V, 50 Amp, 2 POLE, CIRCUIT BREAKER (NON GFCI) #8 AWG WHITE, NEUTRAL #10 AWG GREEN, GROUND #8 AWG BLUE, L1 50A #8 AWG RED, L2 MAIN SERVICE ELECTRICAL PANEL N L1 L2 L2 #12 AWG RED L1 #12 AWG BLUE GRD 20A N #12 AWG WHITE L2 #10 AWG RED 30A L1 #10 AWG BLUE GROUND #10 AWG GREEN 1 2 3 4 5 TB1 See owner s manual or control bo schematic for electrical connection details. GRD LESS THAN 100 FT. CONTROL BOX NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. Prodigy (Model H) and Jetsetter (Model JJ) WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. HEATER GROUND 230V, 50 Amp, 2 POLE, CIRCUIT BREAKER (NON GFCI) #8 AWG WHITE, NEUTRAL #10 AWG GREEN, GROUND #8 AWG BLUE, L1 50A #8 AWG RED, L2 MAIN SERVICE ELECTRICAL PANEL LESS THAN 100 FT. N L1 L2 L1 #12 AWG BLUE GRD 20A N #12 AWG WHITE L2 #10 AWG RED 30A L1 #10 AWG BLUE GROUND #10 AWG GREEN 1 2 3 4 5 TB1 See owner s manual or control bo schematic for electrical conversion and connection GRD details. CONTROL BOX NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the *AVAILABLE FROM DEALER. NOTE: ALL WIRING SHOULD BE COPPER. Page 15 Pre-Delivery Instructions

WIRE INSTALLATION FOR CONTROL BOX TERMINAL BLOCK (Layout of Spa s Terminal Blocks may vary) Wire Installation Steps Insert screwdriver to engage cage clamp 3 Push top of screwdriver away from wire Terminal Block 1/2 4 Strip wire insulation back ½ Install Stripped end of wire into Terminal Block Refer to spa s wiring diagram on back of Control Bo Cover for proper wiring Entire stripped end of wire must be inside Terminal Block 5 3 After step 6, pull on wire to ensure proper installation Remove screwdriver 6 SERVICES AVAILABLE FROM YOUR HOT SPRING SPA DEALER Service Pre-Delivery site inspection Deliver spa to installation site Unwrap spa and haul away packaging material Set up & level spa Fill the spa with water Connect the spa to its power source (115 volt models) Eplain and test the spa s operation Jet system Moto-Massage jet Comfort Control system Set temperature control Eplain the safety features Control panel functions GFCI Heater high limit Heater thermal cut-off General spa operation & maintenance orientation Water quality and maintenance orientation Adjust the water s Total Alkalinity, Calcium Hardness and ph Sanitize the water Inspect the spa cover, place on spa Review winterizing instructions Review Owner s Manual & Warranty Card Follow-up call In-store spa water analysis TOTAL COST Cost Pre-Delivery Instructions Page 16

ADDITIONAL PRODUCTS AVAILABLE FROM YOUR HOT SPRING SPA DEALER Salt Water Sanitizing System water care system featuring the FreshWater III high output ozone, MPS, and FreshWaterAg+ Silver Ion Cartridge Pre-filter Calcium Remover, CoverCradle II, UpRite and Lift n Glide systems. Cover Cradle UpRite - 7 Clearance required Lift n Glide - 14 Clearance required CONTRACTOR SUGGESTIONS Electrician Name: Telephone: Name: Telephone: Masonry Name: Telephone: Name: Telephone: General Name: Telephone: Name: Telephone: Page 17 Pre-Delivery Instructions

Spa Specifications Footprint Dimensions Height Effective Filter area Heater (Watts) Water Dry Weight Filled Weight* Dead Weight* Electrical Requirements Vista (Model SS) Seats 6 7'7" 8'4" 2.31m 2.54m 38" 0.97 m 325** feet 4,000 500 gallons 1,893 litres 1008 457 6,228 2,825 120 per foot 230 volt, 50 amp Single phase GFCI protected circuit Grandee (Model GG) Seats 7 7'7" 8'4" 2.31m 2.54m 38" 0.97 m 325** feet 4,000 500 gallons 1,893 litres 1,008 457 6,403 2,904 125 per foot 230 volt, 50 amp Single phase GFCI protected circuit Envoy (Model KK) Seats 5 7'9" 7' 5" 2.36m 2.26m 36" 0.91 m 325** feet 4,000 450 gallons 1,703 litres 875 397 5,503 2,496 120 per foot 230 volt, 50 amp Single phase GFCI protected circuit Aria (Model AR) Seats 5 7'3" 7'3" 2.21m 2.21m 36" 0.91 m 325 feet 4,000 365 gallons 1,385 litres 789 358 4,708 2,136 120 per foot 230 volt, 50 amp Single phase GFCI protected circuit Vanguard (Model VV) Seats 6 7'3" 7'3" 2.21m 2.21m 36" 0.91 m 150 feet 6,000 400 gallons 1,514 litres 789 358 5,175 2,347 135 per foot 230 volt, 50 amp Single phase GFCI protected circuit Sovereign (Model II) Seats 6 6'8" 7'9" 2.03m 2.36m 33" 0.84 m 120 feet 6,000 355 gallons 1,344 litres 713 322 4,724 2,143 115 per foot 230 volt, 50 amp Single phase GFCI protected circuit Prodigy (Model H) Seats 5 6'2" 7'3" 1.88m 2.21m 33" 0.84 m 90 feet 1,500 or 6,000 325 gallons 1,230 litres 613 278 4,199 1,905 120 per foot 115 volt, 20 amp Dedicated GFCI protected circuit or 230 volt, 50 amp Single phase GFCI protected circuit Jetsetter (Model JJ) Seats 3 5'5" 7'0" 1.65m 2.13m 29" 0.74 m 90 feet 1,500 or 6,000 225 gallons 852 litres 450 204 2,852 1,294 100 per foot 115 volt, 20 amp Dedicated GFCI protected circuit or 230 volt, 50 amp Single phase GFCI protected circuit CAUTION: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck. * NOTE: The Filled weight and Dead weight of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs). **Effective filter area is based on 6.5 feet actual area per filter with 10 times effectivity rating. Pre-Delivery Instructions Page 18

Page 19 Pre-Delivery Instructions

WATKINS MANUFACTURING CORPORATION CoverShield, EverFresh, FreshWater, Reduce, Revitalize, Refresh and The Home Relaation Specialists are trademarks of Watkins Manufacturing Corporation. Page