PowerAir Compressor Installation

Similar documents
ClassicSeries Compressor Installation

Dental Compressed Air System

PRE-INSTALLATION GUIDE

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Installation & Operation

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Rock Compressors. Service and Parts Manual. Twin R22 Triple R42 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers: R42 Shown

Installation Manual 354 / 355 Combination Lighting System

ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual

PowerMax Surgical Suction Producers

Dental Dry Suction. Installation/User Guide

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

TECH WEST INC. Manufacturers of Dental Vacuum and Air Systems N. Argyle Ave. Fresno, CA (559) (800) FAX (559)

PowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:

Master Slave Converter [ VAC & VAC]

ULTRA CLEAN OILLESS COMPRESSOR

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

User s and Installation Manual

Side Delivery Unit Installation

Installation Manual. 355 Lighting System

Installation Instructions

PowerVac. Service and Parts Manual P3 P5 P7. Single Vac Units. Twin Vac Units P6 P10 P14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY.

Transformer Installation, Operation, and Maintenance Manual

High Frequency SineWave Guardian TM

STEP-BY-STEP INSTALLATION GUIDE

Asepsis 21 Delivery Unit

Flex Work Station Delivery Units Installation Guide

SHALLOW WELL JET PUMP

Veterinary Anesthesia Gas Scavenging System (Active)

AirStar Tandem Installation Kit Part Number 85694

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Microprocessor Controlled Dental Vacuum System Installation Manual

Enclosed Electric Rotary Screw Compressor Installation Guide

Electric Reciprocating Compressor. Installation Guide

CoolWave 2 Phase Control Board and Cable Replacement Kit

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Dental Vacuum System. Installation Overview

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

STAR STOP SHALLOW WELL JET PUMP

Active Evacuation System (AES)

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Owner's/Installation Manual

Installation Instructions

Owner s Manual GLASSLINED PUMP TANK

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

PBA Series Prelube Controls

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

HEINE NT4 MED V

ALWAYS SAVE THIS BOOK FOR FURE REFERENCE.

Canis Major Veterinary Tables

Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES

Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

Compressor Installation Guide

DENTAL AIR SYSTEM. Installation and Operation Manual

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

ALL PURPOSE CNC/HEAVY DUTY

Technical Manual. DLM Module. This manual should remain with the unit.

Installation Instructions

ILCS EDGE System Installation Manual

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

M-3025CB-AV Fuel Pump

Operating Instructions - Electric Pow'r-Riser Models

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

INSTALLATION and OPERATION INSTRUCTIONS

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

END SUCTION CENTRIFUGAL PUMPS

Reverse Osmosis System

AUTO CHARGE D PUMP PLUS

Installation Manual. 354 / 355 Combination Lighting System MA475900

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Installation Instructions

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Installation Instructions Electric Heaters 5 20 kw

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Veterinary Scavenger Interface

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Typical Applications. Horizontal Installation

Electrical Installation

Instruction Manual. Q Series 2 Motor Control Modules - OEM

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Transcription:

PowerAir Compressor Installation Applies to Models: P21-115 Volts P22, P32-230 Volts P52, P72-230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Model P21 (115 Volt) or P22 (230 Volt) - Twin.75 HP Heads AA188201 Model P72 - Triple 1.6 HP Heads AA188200 Midmark Corporation 2006 1 10541100 Rev. O (11/11)

Compressor Main Component Locations Hour Meter Fuse Electrical Box Purge Check Valve Gauge AA182700 Moisture Indicator Check Valve Manifold Office Air Line Supply Connection P22 Model Shown Components Shown are Typical on all PowerAir Compressor Models Midmark Corporation 2006 2

Compressor Site Requirements Electrical Models Supply CL21 CL22 CL32 CL52 P21 P22 P32 P52 P72 Voltage 115 208-230 208-230 208-230 115 208-230 208-230 208-230 208-230 Single Phase Disconnect Switch Box - Fused - User Supplied - Box(es) must be located within 3 ft. of compressor Plumbing Fresh Air Intake Line Type Line Sizing Compressor Connections Drain Type Delivery Line Main Trunk Line Operatory Branch Lines Environmental Equipment Room Ambient Temperature - Operational Installation Kit Provided with Compressors 60 Hz 20 Amps 20 Amps 20 Amps 30 Amps 20 Amps 20 Amps 20 Amps PVC 1" Minimum (Provided by Contractor) 1" MPT or 1" PVC Slip Connectors Poly Tube (Provided with Install Kit) 40-104 Fahrenheit / 4-40 Celsius 30 Amps 40 Amps 3/8" to 3/4" Copper, as site layout dictates. Terminate in mechanical room with 1/2" FPT. Flex hose provided for service connection. Trunk line to slope 1/4" / 10ft toward source compressor. 3/8" to 3/4" Copper - Same size as trunk line. Terminate 1/2" or 5/8" FPT at Operatory junction box location. Feet with Hardware Indicator for Coalescing Filter Elbow for Operatory Line Connection Exhaust Silencer Fresh Air Intake Hose Length - 10 Oil Operatory Air Line Length - 6 AA189300 Midmark Corporation 2006 3

Specification Compressor SheetSite Layout Elevation View Roof Fresh Air Intake To prevent moisture from entering the compressor: Fresh air intake should be routed to outside air source. Use one or more 90 elbows to cap an outside vertical fresh air line. Disconnect Box Refer to: Specification Table (Provided by Electrician) OR Fresh air intake can be set-up to pull air from a drop celing or another room. Drop Ceiling Fresh Air Intake to Another Room or Drop Ceiling Operatory Air Line Connection AA189100 6 Clearance must be maintained on all sides, front and back of Compressor AA223800 Sample Plumbing Layout AIR LINE SIZING CHART Compressor CFM @ 80 psig Main Header Line Size 5-10 3/8" ODT 10-20 1/2" ODT 20-30 5/8" ODT 30-40 3/4" ODT Equipment Room Main Trunk Line Branch Line Typical 3/8 to 3/4 6 12 12 AA189200 Midmark Corporation 2006 4

Important Information Intended Use To provide suction during general examinations and procedures conducted by qualified dental professionals. Electromagnetic Interference This Midmark Liquid Ring Vacuum is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and these units: Remove interfering device from room Plug interfering device into an isolated circuit Increase separation between unit and interfering device Contact Midmark if interference persists Disposal of Equipment At the end of product life, the unit(s), accessory, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods. Transportation / Storage Conditions Ambient Temperature Range:... 40 F to 104 F (4 C to 37 C) Relative Humidity...10% to 90% (non-condensing) Atmospheric Pressure...500hPa to 1060hPa (0.49atm to 1.05atm) 2 Keep dry Maximum stacking height (palletted units) Fuse rating specification Consult User Guide for important information. Proper shipping orientation Fragile DANGER Indicates an imminently hazardous situation which will result in serious or fatal injury if not avoided. This symbol is used only in the most extreme conditions. WARNING Indicates a potentially hazardous situation which could result in serious injury if not avoided. CAUTION Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices. Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided Note Amplifies a procedure, practice, or condition. Caution hot surface Protective earth ground IPXO Ordinary Equipment This product has been evaluated with respect to electrical shock, fire & mechanical hazards only, in accordance with UL60601-1 and CAN/CSA C22.2 NO. 601.1. AA2369 Midmark Corporation 2006 5

Before you Install... Step 1: Remove compressor and accessories from shipping skid. Equipment Alert Compressor system must be installed in an air conditioned and or ventilated room to ensure operational ambient temperature of 40 to 104 Fahrenheit (4-40 Celsius). A 6 clearance is required on the rear and one side to allow air flow around the unit. Failure to do so could cause premature loss of system performance and void warranty. Note: This step is optional but, might be required by local codes. Step 2: Verify o-rings are seated on bottom of indicator. Remove plate on top of coalescing filter. Install indicator on top of coalescing filter. Coalescing Filter Indicator Step 4: Screw exhaust silencer into bottom of solenoid. Exhaust Silencer Step 5: Connect poly tube to bottom of exhaust silencer. Position opposite end next to floor drain or over the edge of a floor sink. Note: Do not place in contamination or standing water. Out to Drain AA182800 Step 3: Install feet. Feet Step 6: Move compressor to a dry, well ventilated area on a solid, level surface. Note: Temperature of room 40 (4 C) min. - 100 (38 ) max. Midmark Corporation 2006 6

Installation Plumbing Connections Equipment Alert To prevent moisture from entering the compressor... Incoming fresh air temperature must not exceed room temperature by more than 20 Fahrenheit or -6 Celsius. Fresh air intake should be routed to an air source outside the equipment room. Refer to Site Layout in this manual for routing recommendations. Tight bends in the fresh air intake hoses may cause them to collapse, potentially leading to premature compressor failure. Step 8: Connect fresh air intake hose to barbed fitting behind compressor to fresh air intake pipe. Connect Hose Supplied With Installation Kit Fresh Air Intake Filter Model P21 & P22 Connect Hose Model P32 Hose Manifold To Operatory Step 7: Install elbow to valve. Connect hose assembly to valve. Connect office air supply line. Note: Hose assembly included in the installation kit. Model P52 & P72 Hose Manifold is Located Under Saddle In Back Connect Hose AA222100 Midmark Corporation 2006 7

Installation Electrical Connections *Refer to Specification Sheet for Electrical Ratings in this manual. P21-115 Model 115 Volt Source Single Phase, 60 Hz 20 Amp Fuse Circuit Breaker Box (Installer Supplied) P22, P32, P52, P72 Models 208-230 Volt Source Single Phase, 60 Hz 20 Amp Fuse Circuit Breaker Box (Installer Supplied) Step 9: WARNING Connect in accordance with NEC Class 2, wiring methods. Connect remote panel wires to Low Voltage Control wires if applicable. Low Voltage Control Wires Control Box High Voltage Remote Panel Transformer 24 V A B C Remote Switch Green/Yellow = Ground (White-115V) (Red -230V) and Black Connect to Electrical Supply* Relay (Contactor) Control Panel Cross Wiring Brand Wire A B (Light) C Midmark Blue White Red Air Techniques Yellow Brown Orange Step 10: Connect conduit cable to user supplied electrical box. DentalEz Black Brown Yellow Matrx Red Blue White Apollo Blue White Red AA183000 Midmark Corporation 2006 8

Installation Check & Test WARNING The On/Off switch controls only the secondary circuit power. The main power source must be turned off to remove all power in the control box. The circuit breaker panel is the main power disconnect. Step 12: Turn power on. Note: Compressor should run quietly and storage tank will begin to pressurize. Access On/Off Switches Loosen four screws in front of electrical box to remove cover. Replace cover after turning switches on. Note: Compressor will shut-off automatically when gauge registers 100 PSI. Step 11: Verify shut-off valve is closed. Gauge Shut -off Valve in Closed Position AA183100 Soapy Water Step 13: Use soapy water to check for pressure leaks. Midmark Corporation 2006 9

Installation Check & Test Note: Monitor line pressure gauge when testing for leaks. Step 14: Open the shut-off valve slowly and allow air to flow into the office air system. Step 15: Allow office line to pressurize for 20-30 seconds. Check storage pressure gauge reading. Step 16: Check gauge reading after 10 minutes. Gauge AA183200 Note: If the storage pressure gauge registers a lower reading, an air leak exists. Locate the leak(s) and repair. Shut-off Valve in Open Position WARNING Always disconnect the power before servicing. The head(s) surface(s) can be very hot depending on compressor usage. Do not touch these parts during or directly after operation. Equipment Alert Verify all leaks are sealed. Air leaks are the main cause of premature compressor failures! Midmark Corporation 2006 10

Specification Sheet PowerAir Compressors Classifications: Class 1, No Applied Part AA183300 Model # Users CFM @ 80 PSI Total HP Tank Capacity Voltage Total Amps Breaker Size Sound Level (dba) Sound Level (dba) With Quiet Cover Dimensions H x W x D (IN.) Dimensions With Sound Cover H x W x D (IN.) Product Weight (LBS.) P21 1-3 5.2 1.5 10 115 16.0 20 65 60 27 x 26 x 24 32 x 26 x 25 225 P22 1-3 5.2 1.5 10 208-230 7.0 20 65 60 27 x 26 x 24 32 x 26 x 25 225 P32 3-5 7.8 2.25 20 208-230 11.0 20 67 62 29 x 33 x 26 33 x 33 x 28 295 P52 5-7 10.6 3.2 20 208-230 20.0 30 70 65 31 x 33 x 26 33 x 33 x 28 345 P72 7-10 15.9 4.8 32 208-230 29.0 40 73 68 33 x 40 x 27 39 x 40 x 30 425 www.midmark.com 1-800-Midmark www.documark.com Midmark Corporation 2006 11

Midmark Corporation 60 Vista Drive Versailles, Ohio 45380 1-800-643-6275 1-937-526-3662 www.midmark.com Midmark Corporation 2006 12