ClassicSeries Compressor Installation

Similar documents
PowerAir Compressor Installation

Dental Compressed Air System

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

PRE-INSTALLATION GUIDE

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Installation & Operation

Installation Manual 354 / 355 Combination Lighting System

Rock Compressors. Service and Parts Manual. Twin R22 Triple R42 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers: R42 Shown

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Dental Dry Suction. Installation/User Guide

Dry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream

Installation Instructions

PowerMax Surgical Suction Producers

AirStar Tandem Installation Kit Part Number 85694

TECH WEST INC. Manufacturers of Dental Vacuum and Air Systems N. Argyle Ave. Fresno, CA (559) (800) FAX (559)

ULTRA CLEAN OILLESS COMPRESSOR

ClassicSeries Wet-Ring Vacuums Single Model Numbers: CV3 CV3R CV5 CV5R CV6 CV6R CV10 CV10R. Service and Parts Manual

Installation Manual. 355 Lighting System

High Frequency SineWave Guardian TM

STEP-BY-STEP INSTALLATION GUIDE

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

User s and Installation Manual

INSTALLATION INSTRUCTIONS

SHALLOW WELL JET PUMP

Transformer Installation, Operation, and Maintenance Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

AUTO CHARGE D PUMP PLUS

Master Slave Converter [ VAC & VAC]

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

DENTAL AIR SYSTEM. Installation and Operation Manual

Asepsis 21 Delivery Unit

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Installation Instructions

PowerMax PM-1 PM-3 PM-4. Service and Parts Manual FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY. Model Numbers:

Enclosed Electric Rotary Screw Compressor Installation Guide

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Electric Reciprocating Compressor. Installation Guide

Dental Vacuum System. Installation Overview

CoolWave 2 Phase Control Board and Cable Replacement Kit

Installation Instructions

STAR STOP SHALLOW WELL JET PUMP

Canis Major Veterinary Tables

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Owner's/Installation Manual

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

PowerVac. Service and Parts Manual P3 P5 P7. Single Vac Units. Twin Vac Units P6 P10 P14 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY.

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Side Delivery Unit Installation

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Installation Manual. 354 / 355 Combination Lighting System MA475900

PBA Series Prelube Controls

ALL PURPOSE CNC/HEAVY DUTY

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

Veterinary Scavenger Interface

Installation Instructions

ALWAYS SAVE THIS BOOK FOR FURE REFERENCE.

6L Oil-less Air Compressor 53103

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

Reverse Osmosis System

Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES

INSTALLATION and OPERATION INSTRUCTIONS

This document describes the commissioning checklist procedures for the Capstone MicroTurbine systems.

Installation Instructions Electric Heaters 5 20 kw

Owner s Manual GLASSLINED PUMP TANK

Active Evacuation System (AES)

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Compressor Installation Guide

Installation Instructions

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

Microprocessor Controlled Dental Vacuum System Installation Manual

BATTERY SAVER LOW RIPPLE HO

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Model 8144NC Fresh Air Ventilator

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

Technical Manual. DLM Module. This manual should remain with the unit.

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Centrifugal Constant Pressure Control

Dental Chair Midmark UltraComfort & UltraTrim Dental Chair

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

Generator Fire Safety: Generator assemblies should be located outside the building.

Veterinary Anesthesia Gas Scavenging System (Active)

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Operating Instructions - Electric Pow'r-Riser Models

M-3025CB-AV Fuel Pump

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

Transcription:

ClassicSeries Compressor Installation Applies to Models: CL21-115 Volts CL22, CL32, CL52-208- 230 Volts Equipment Alert Compressor system must be installed per local plumbing and electrical codes. Note: Fresh air intake termination pipe to be provided by installer. Fresh Air Intake Oil Fill Oil Drain Hour Meter Electrical Box Capacitor / Relay Box Purge Check Valve Gauge AA181101 Moisture Indicator Office Air Line Supply Connection Check Valve Manifold Model CL32 Shown Components Shown are Typical on all ClassicSeries Compressor Models Midmark Corporation 2006 1 10540700 Rev. O (11/11)

Compressor Site Requirements Electrical Models Supply CL21 CL22 CL32 CL52 P21 P22 P32 P52 P72 Voltage 115 208-230 208-230 208-230 115 208-230 208-230 208-230 208-230 Single Phase Disconnect Switch Box - Fused - User Supplied - Box(es) must be located within 3 ft. of compressor Plumbing Fresh Air Intake Line Type Line Sizing Compressor Connections Drain Type Delivery Line Main Trunk Line Operatory Branch Lines Environmental Equipment Room Ambient Temperature - Operational Installation Kit Provided with Compressors 60 Hz 20 Amps 20 Amps 20 Amps 30 Amps 20 Amps 20 Amps 20 Amps PVC 1" Minimum (Provided by Contractor) 1" MPT or 1" PVC Slip Connectors Poly Tube (Provided with Install Kit) 40-104 Fahrenheit / 4-40 Celsius 30 Amps 40 Amps 3/8" to 3/4" Copper, as site layout dictates. Terminate in mechanical room with 1/2" FPT. Flex hose provided for service connection. Trunk line to slope 1/4" / 10ft toward source compressor. 3/8" to 3/4" Copper - Same size as trunk line. Terminate 1/2" or 5/8" FPT at Operatory junction box location. Feet with Hardware Indicator for Coalescing Filter Elbow for Operatory Line Connection Exhaust Silencer Fresh Air Intake Hose Length - 10 Oil Operatory Air Line Length - 6 AA189300 Midmark Corporation 2006 2

Specification Compressor SheetSite Layout Elevation View Roof Fresh Air Intake To prevent moisture from entering the compressor: Fresh air intake should be routed to outside air source. Use one or more 90 elbows to cap an outside vertical fresh air line. Disconnect Box 208-230V 30 Amp Single Phase 60 Hz Circuit with approved ground required. (Provided by Electrician) OR Fresh air intake can be set-up to pull air from a drop celing or another room. Drop Ceiling Fresh Air Intake to Another Room or Drop Ceiling Operatory Air Line Connection AA189100 6 Clearance must be maintained on all sides, front and back of Compressor AA223800 Sample Plumbing Layout AIR LINE SIZING CHART Compressor CFM @ 80 psig Main Header Line Size 5-10 3/8" ODT 10-20 1/2" ODT 20-30 5/8" ODT 30-40 3/4" ODT Equipment Room Main Trunk Line Branch Line Typical 3/8 to 3/4 6 12 12 AA189200 Midmark Corporation 2006 3

Important Information Intended Use To provide compressed air during general examinations and procedures conducted by qualified dental professionals. Electromagnetic Interference This Midmark Lubricated Compressor is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and these units: Remove interfering device from room Plug interfering device into an isolated circuit Increase separation between unit and interfering device Contact Midmark if interference persists Disposal of Equipment At the end of product life, the unit(s), accessory, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods. Transportation / Storage Conditions Ambient Temperature Range:... 40 F to 104 F (4 C to 37 C) Relative Humidity...10% to 90% (non-condensing) Atmospheric Pressure...500hPa to 1060hPa (0.49atm to 1.05atm) Keep dry Consult User Guide for important information. DANGER Indicates an imminently hazardous situation which will result in serious or fatal injury if not avoided. This symbol is used only in the most extreme conditions. WARNING Indicates a potentially hazardous situation which could result in serious injury if not avoided. CAUTION Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices. Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided Maximum stacking height (palletted units) Fuse rating specification Proper shipping orientation Fragile Note Amplifies a procedure, practice, or condition. Caution hot surface Protective earth ground IPXO Ordinary Equipment This product has been evaluated with respect to electrical shock, fire & mechanical hazards only, in accordance with UL60601-1 and CAN/CSA C22.2 NO. 601.1. AA2369 Midmark Corporation 2006 4

Before you Install... Equipment Alert Compressor system must be installed in an air conditioned and or ventilated room to ensure operational ambient temperature of 40 to 104 Fahrenheit (4-40 Celsius). A 6 clearance is required on the rear and one side to allow air flow around the unit. Failure to do so could cause premature loss of system performance and void warranty. Step 8: Remove tape and plug from oil filler cap(s). Note: Check oil level on site glass, add if below 1/3 full. Use only Midmark Oil PN 77000953 Oil Fill Step 1: Remove compressor and accessories from shipping skid. CAUTION Due to elevated surface temperatures, Do not install within patient vicinity. Step 2: Move compressor to a dry, well ventilated area on a solid, level surface. Note: Temperature of room 40 (4 C) min. - 100 (38 ) max. Oil Site Gauge Note: This step is optional but might be required by local codes. Coalescing Filter Indicator Step 7: Verify o-rings are seated on bottom of indicator. Remove plate on top of coalescing filter. Install indicator on top of coalescing filter. Motor Mount Nuts Step 6: Attach exhaust silencer into bottom of solenoid. Step 3: Loosen all motor mount nuts three full turns. Step 5: Connect poly tube to bottom of exhaust silencer. Position opposite end next to floor drain or over the edge of a floor sink. Note: Do not place in contamination or standing water. Exhaust Silencer Out to Drain AA181600 Feet Step 4: Install feet. Midmark Corporation 2006 5

Installation Plumbing Connections Equipment Alert To prevent moisture from entering the compressor... Incoming fresh air temperature must not exceed room temperature by more than 20 Fahrenheit or -6 Celsius. Fresh air intake should be routed to outside air source. Refer to Site Layout in this manual for routing recommendations. Tight bends in the fresh air intake hoses may cause them to collapse, potentially leading to premature compressor failure. Step 9: Connect fresh air intake hose to barbed fitting behind compressor to fresh air intake pipe. Top View Shown Connect Hose and Fitting Supplied with Installation Kit. Fresh Air Intake Filter Model CL21 & CL22 Connect Hose Supplied with Installation Kit Model CL32 To Operatory AA181701 Connect Hose Supplied with Installation Kit. Step 10: Install elbow to valve. Connect hose assembly to valve. Connect office air supply line. Note: Hose assembly included in the installation kit. Model CL52 Midmark Corporation 2006 6

Installation Electrical Connections *Refer to Specification Sheet for Electrical Ratings in this manual. High Voltage Transformer WARNING Connect in accordance with NEC Class 2, wiring methods. Step 11: Connect remote panel wires to Low Voltage Control wires if applicable. Remote Panel 24 V A B Remote Switch Light CL21-115 Model 115 Volt Source Single Phase, 60 Hz 20 Amp Fuse Circuit Breaker Box (Installer Supplied) CL22 / CL32 / CL52 Models 208-230 Volt Source Single Phase, 50/60 Hz 20 or 30 Amp Fuse Circuit Breaker Box (Installer Supplied) Low Voltage Control Wires Green/Yellow =Ground (White-115V) (Red -230V) and Black Connect to Electrical Supply* C Relay (Contactor) Control Panel Reference Cross Wiring Brand Wire A B (Light) C Midmark Blue White Red AA181800 Air Techniques Yellow Brown Orange DentalEZ Black Brown Yellow Apollo Blue White Red Step 12: Connect conduit cable to user supplied electrical box. Matrx Red Blue White Midmark Corporation 2006 7

Installation Check & Test WARNING The On/Off switch controls only the secondary circuit power. The main power source must be turned off to remove all power in the control box. The circuit breaker panel is the main power disconnect. Step 14: Turn power on. Note: Compressor should run quietly and storage tank will begin to pressurize. Access On/Off Switches Loosen four screws in front of electrical box to remove cover. Replace cover after turning switches on. Note: Compressor will shut-off automatically when gauge registers 100 PSI. Step 13: Verify shut-off valve is closed. Gauge Shut-off Valve in Closed Position AA181900 Step 15: Use soapy water to check for pressure leaks. Soapy Water Midmark Corporation 2006 8

Installation Check & Test Note: Monitor line pressure (gauge) when testing for leaks. Step 16: Open the shut-off valve slowly and allow air to flow into the office air system. Step 17: Allow office air line to pressurize for 20-30 seconds. Check storage pressure gauge reading. Step 18: Check gauge reading after 10 minutes. Gauge AA182000 Note: If the storage pressure gauge registers a lower reading, an air leak exists. Locate the leak(s) and repair. Shut-off Valve in Opened Position WARNING Always disconnect the power before servicing. The head(s) surface(s) can be very hot depending on compressor usage. Do not touch these parts during or directly after operation. Equipment Alert Verify all leaks are sealed. Air leaks are the main cause of premature compressor failures! Midmark Corporation 2006 9

Specification Sheet ClassicSeries Compressors AA181500 Model CL32 Shown Classifications: Class 1, No Applied Part, Continuous Operation Model # of Users CFM @ 80 PSI Total HP Tank Capacity Voltage Total Amps Breaker Size (Amps) Sound Level (dba) Dimensions H x W x D (IN.) Product Weight (lbs.) CL21 1-3 5.3 1.0 10 115 12.4 20 68 29 x 26 x 24 202 CL22 1-3 5.3 1.0 10 208-230 6.0 20 68 29 x 26 x 24 202 CL32 3-5 10.6 2.0 20 208-230 12.0 20 71 31 x 33 x 26 329 CL52 5-7 15.9 3.0 32 208-230 18.0 30 75 32 x 41 x 27 460 www.midmark.com 1-800-Midmark www.documark.com Midmark Corporation 2006 10

Midmark Corporation 145 Mid County Drive Orchard Park, New York 14127 Customer Service Phone: 1-800-643-6275 Technical Service Phone: 1-888-279-1260 Fax: 1-877-725-6495 www.midmark.com Midmark Corporation 2006 11