CRE32-3 AN-F-A-E-HQQE 3x HZ

Similar documents
CRE A-F-A-E-HQQE 3x HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

Grundfos pump

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CR A-F-A-V-HQQV 3x400/ HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRE A-F-A-E-HQQE 3x HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CR A-F-A-V-HBQV 3x400/ HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CRE20-08 A-F-A-E-HQQE 3x HZ

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

NB80-160/161 A-F2-A-BQQE

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

TP /4-A-F-A-BQQE 400Y 50HZ

NB /193 A-F2-A-BAQE

TP /2-A-F-A-BQQE 400D 50HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

Hydro MPC-E 2CRIE L GNL

NBE50-250/205 A-F2-A-BAQE

TP /2-A-F-A-BAQE 400D 50HZ

NK /310A2F1AE-SBAQE

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

NB /263 AS-F2-A-BAQE

NKE80-160/175A2F2AE-SBQQE

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

NB /438 A-F1-A-GQQE

TPED /4-A-F-A-BQQE 3X400 50HZ

TPE /4-A-F-A-BAQE 3X400 50HZ

TP /4-A-F-A-BUBE 400Y 50HZ

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

TPE /2-S-A-F-A-BAQE 3X400 50HZ

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

TP /2-A-F-A-BQQE 400D 50HZ

NBE40-125/139 AS-F2-A-BAQE

TPE N-A-F-A-GQQE

Transcription:

GRUNDFOS DATA BOOKLET CRE32-3 AN-F-A-E-HQQE 3x4 5 HZ Grundfos Pump 96122652 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre32/96122652/cre-32-3-an-f-a-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRE 32-3 AN-F-A-E-HQQE Product No.: 96122652 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. Further product details The pump is equipped with a pressure sensor registering pump discharge pressure and enabling controlled pump operation based on constant pressure. The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/9

The motor stool connects the pump head and motor. The pump head has a combined 1/2" priming plug and air vent screw. The pressure sensor is fitted to the pump head. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is retained in the pump head by a cover and screws. It can be replaced without removing the motor. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. Both the suction and the discharge side of the base have two pressure gauge tappings. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. 2/9

Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with free-hole flange (FF). Motor mounting designation in accordance with IEC 634-7: IM B 5 (Code I) / IM 31 (Code II). Electrical tolerances comply with IEC 634. The motor requires no external motor protection. The motor control unit incorporates protection against slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Materials: Pump housing: Impeller: Water 243.. 393 K 293 K 998.2 kg/m³ 2919 rpm 3 m³/h 44.4 m HQQE Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -3 C Flange standard: DIN Pipe connection: DN 65 Pressure stage: PN 16 / PN 25 / PN 4 Flange size for motor: FF265 Electrical data: Motor type: 132SC Number of poles: 2 Rated power - P2: 5.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 11,-8,8 A Cos phi - power factor:,94-,93 3/9

Position Qty. Description Rated speed: 36-353 rpm Efficiency: IE3 89,2% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 13 kg Gross weight: 126 kg Shipping volume:.321 m3 4/9

96122652 CRE 32-3 5 Hz H [m] 65 CRE 32-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 6 1 % 55 5 1 45 9 4 8 35 7 3 6 25 5 2 4 15 3 1 2 5 25 % 1 5 1 15 2 25 3 35 4 P [kw] 7 Q [m³/h] NPSH [m] 14 6 P1 12 5 P2 1 4 8 3 6 2 4 1 2 5/9

- 1K Description Value Product name: CRE 32-3 AN-F-A-E-HQQE Product No: 96122652 EAN number: 57396686967 Technical: Speed for pump data: 2919 rpm Rated flow: 3 m³/h Rated head: 44.4 m Impellers: 3 Shaft seal: HQQE Stages: 3 Pump version: AN Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 A E H [m] 1 % 6 55 5 45 4 35 3 25 2 15 1 5 25 % CRE 32-3, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 5 1 15 2 25 3 35 P [kw] 4 2 8 x ø18 ø185 ø145 ø17 4 x ø14 Q [m³/h] P1 P2 eta [%] 1 9 8 7 6 5 4 3 2 1 NPSH [m] 1 5 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -3 C Flange standard: DIN Connect code: F Pipe connection: DN 65 Pressure stage: PN 16 / PN 25 / PN 4 Flange size for motor: FF265 188 22 3 ø74 3 17 24 223 298 32 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 243.. 393 K 293 K 998.2 kg/m³ 645 391 15 Electrical data: Motor type: 132SC Number of poles: 2 Rated power - P2: 5.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 11,-8,8 A Cos phi - power factor:,94-,93 Rated speed: 36-353 rpm Efficiency: IE3 89,2% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: NONE Motor No: 85757417 9686116 +OUT -1V /4-2mA +OUT A:RS485 A Y:SHIELD B:RS485 B 7: SENSOR INPUT 4-2mA 8: +24V 9: GND 1: DIGITAL INPUT /1 CONNECTION FOR GRUNDFOS SENSOR OPTIONAL SUPPLY: SEE NAMEPLATE FOR FUTHER DATA SIGNAL RELAY: Max:25V/2A AC1 Min: DC 5V/1mA STOP RUN /4-2m A -1V + - NC C NO L1 L2 L3 2: RUN/STOP 3: GND 4: SETPOINT 5: +1V 6: GND CONNECTION FOR PC-TOOL Controls: Pressure sensor: Y Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 13 kg Gross weight: 126 kg Shipping volume:.321 m3 6/9

Description Value Config. file no: 96115832 7/9

96122652 CRE 32-3 5 Hz 22 188 645 391 3 8 x ø18 15 ø17 ø145 ø185 17 3 ø74 4 x ø14 223 24 32 298 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

96122652 CRE 32-3 5 Hz 9686116 A B 7: SENSOR INPUT 4-2m 8: +24V 9: GND A -1V + - 1K 2: RUN/STOP 3: GND 4: SETPOINT 5: +1V 6: GND CONNECTION FOR PC-TOOL - +OUT +OUT AA NC C NO L1 L2 L3 A:RS485 Y:SHIELD B:RS485-1V /4-2m /1 1: DIGITAL INPUT CONNECTION FOR GRUNDFOS SENSOR OPTIONAL /4-2m SUPPLY: SEE NAMEPLATE FOR FUTHER DATA SIGNAL RELAY: Max:25V/2A AC1 Min: DC 5V/1mA STOP RUN Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89