Operating Instructions - Revision 4.1 January 2016 RJ11 PORT

Similar documents
CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The first section of the guide deals with the UP SECTION, while the second deals with the DOWN SECTION.

CAUTION: The possible problems and causes are listed in likelihood and ease of checking.

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

AXD 530 MicroManometer

- Rated Flow Table (Metric)

91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE

i n s t r u c t i o n m a n u a l

IMPORTANT SAFETY INSTRUCTIONS

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

182-LED Solar-Powered Motion Security Light. Owner s Manual

LG Alert TM Helping Drivers Operate Safely. LG Alert Oshkosh Truck Corporation User / Installation Manual

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Price Computing Scale D Series Operation Manual

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

LG Alert TM Helping Drivers Operate Safely. LG Alert Lateral Acceleration Indicator User / Installation Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Thermometer models / 00831A

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Owner s Manual & Safety Instructions

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Owner s Guide CARS & CA4B5

120-LED Solar-Powered Motion Security Light

Effective June 1, 2013 This guide supersedes all previous versions

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

Thermometer models 02023, 02028, 02029

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual

Owner s Guide. ca6154

Thermometer model 00826

Two Channel Remote Shutdown Device

Price Computing Scale DS Series Operation Manual

MODEL PS-4 DIGITAL PORTION SCALE

Model DS7060 Handrail Scale. User Manual

Thermometer models 02023/02028/02053/02054

SLA Battery Capacity Analyzer

Weather Thermometer models 00754/00771W/00772W/00773W/00774W

Patron Call System. Scope s DataPage II Lite & NexCall Coaster. Operators/Installation Manual

For questions or technical support, 1. Wiring Reference:

Single COB LED Solar-Powered Motion Security Light

AT&T. SPlRIT Communications System SPIRIT Attendant ConnecT/R Owner s Manual

Wireless Thermometer model 00782W

Operator s Manual TC-253A. Temperature Converter

Wireless Thermometer model 00380

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

Electric Chainsaw Sharpener With Bar Mount

All products subject to this warranty must be returned for examination, repair or replacement to:

OPERATION AND MAINTENANCE

Intelligent Electronic Safe

MaxLite LED Medium Area Light

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

ECLIPSE Laundry Dispenser Controller

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

Filtered PWM Speed Control for Permanent Magnet DC Motors

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

IN NORTH AMERICA ONLY

LS100L Battery-powered Punch Driver

82V LITHIUM-ION BATTERY CHARGER GC 400

OPERATING INSTRUCTIONS

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

INSP-3 Wiring Inspection Tester

60 Watt Industrial LED Low Bay Light

PROPHET PLUS LCD INSTRUCTION MANUAL Horizon Hobby, Inc Fieldstone Road Champaign, IL USA

Tension your belts at the speed of light!

Andatech SOBERPOINT 3. Wall Mounted Breathalyser USER S MANUAL

Sherman + Reilly Battery-powered Pistol Grip Cable Cutters

Large Hydraulic Bead Breaker

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

ODY-19-1 AIR PRESSURE GAUGE

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

HLY-1111 HEAD TEMPERATURE GAUGE

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

Heavy-Duty Sawhorse. Owner s Manual

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Ohaus ES Series Bench Scale

a new.wave.of city transport vesper.world

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Weather Forecaster model 00837W

Chair-Check II User Manual

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Easy-On Wireless Tail Lights User s Guide

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Hydraulic Bead Breaker Kit

3000-Lb. Vehicle Positioning Jacks. Owner s Manual

INSTRUCTION and OPERATIONS MANUAL. for

ca1153 Owner s Guide

Transcription:

Operating Instructions - Revision 4.1 January 2016 Before operating this unit please read this manual. Retain this manual for future reference. Introduction: SafeTach keeps personnel out of the hoistway. SafeTach is used to facilitate elevator installation setup, maintenance and evaluation. SafeTach is a simple tool for measuring speed and forces of hydraulic and traction elevators felt during elevator movement, providing real-time performance information, including g-forces for answering code requirements. SafeTach eliminates the need for two people when measuring the speed of an elevator. It is no longer necessary to take measurements riding the top of the elevator cab and is not necessary to place the elevator out of service to obtain readings. Simply placing SafeTach on the elevator floor and running the elevator will acquire speed and rate information. SafeTach may be placed unattended inside the elevator to automatically record measurements for speed in load tests, plus as an aid in checking and setting governors and overspeed valves. OWNER S RECORD Model Type and serial number are located on a label on the underside of the unit. The Software Version is seen on the warm up screen. Refer to the serial number if you call Maxton regarding this product. Record the Software Version and serial number: Software Version Serial Number V RJ11 PORT The RJ11 port is provided for a wired remote device (optional). WARNING: Instrument damage will result if this port is connected to a phone jack. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com

TABLE OF CONTENTS Basic Operation Principle of Operation... 1 Battery Power... 1 Installing and changing the batteries Battery life Using the SafeTach... 2-3 Keep the unit in its case Turn on the unit Taking another reading Taking a reading Turn off the unit Display Information...... 4-7 High Speed Decel Leveling Speed Stop Time Jerk Force Low Speed test Start Save / RCL function Accel To save a run Using the SafeTach to make Adjustments... 8-13 Precaution Alerts Generic hydraulic controller Maxton hydraulic controller Troubleshooting... 14-15 Cautions and Warnings, Specifications, Calibration, Cleaning, Warranty and Notes... 16-19 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com

BASIC OPERATION PRINCIPLE OF OPERATION: SafeTach uses a sensitive electronic circuit to measure acceleration and deceleration forces along a vertical axis. A digital computer integrates the acceleration over time to obtain and display force and velocity. A short warm-up period on a stable surface is required to allow the unit to sense and stabilize for effects of local gravity. BATTERY POWER: NOTE: SafeTach will automatically turn-off after 10 minutes of inactivity. Installing and changing the batteries: The 4, AA alkaline batteries are accessed via a door on bottom of the unit. NOTE: The positive side of the batteries all face the same direction. (See Picture on right) Battery life: The battery life display shows remaining battery charge. Replace batteries when low battery is indicated. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 1

USING THE SafeTach Keep the unit in its case: The soft case is designed to provide protection for the unit and a stable environment for SafeTach measurements. Minor imperfections on the measuring surface are tolerated by using the unit in its case. The case also acts to keep the SafeTach from rocking or slipping which would affect the readings obtained. Turn on the unit: Press the power button until the SafeTach turns on. Select a unit of measurement for speed by pressing the left arrow button. (Standard or Metric) Select a unit of measurement for force by pressing the right arrow button. (g s or milli-g s) Place the SafeTach flat on the elevator floor before warm-up is completed. The moving bar shows the status. Position the unit so that it is readable and within reach of the car operating panel. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 2

Take a reading: When the warm-up is complete PLACE CALL will appear on the screen. Do not disturb or move the SafeTach unit. Press an elevator floor button to put the elevator in motion. When the elevator starts to move the SafeTach is automatically triggered. The SafeTach will display the information collected on the data screen. Take another reading: Keep the SafeTach in place on the elevator floor. With the elevator stopped & steady, press the Reset button. PLACE CALL will appear. The SafeTach is ready for another reading. Turn off the unit: Press the power button until the SafeTach turns off. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 3

DISPLAY INFORMATION High Speed (Hi) fpm High speed readings are provided during the run. Leveling Speed (Lv) fpm A flashing o.k. hand indicates that leveling is occurring and speed is being captured. Leveling speed readings are indicated at completion of run. Optimal hydraulic leveling speed is 7-13 fpm. At 14 fpm and higher, a HIGH level speed alert is generated. Below 6 fpm a SLOW leveling speed alert is generated. For elevators operating above 225 fpm a stop hand indicates that the elevator has come to a stop. Time sec: Duration of motion is provided for high speed, leveling, and run time for reference and help in adjusting. Leveling time of 1-4 seconds is the expected range for the hydraulic elevator. For floor-to-floor time measurement by the SafeTach, Flr selection will trigger a separate clock and operate like a stopwatch. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 4

Force g s SafeTach provides indication of several elevator rates of motion. Start, Accel, Decel and Stop are displayed as they occur. These rate readings provide useful information that can be used to improve elevator performance. Understanding what a reading represents is essential to making good use of the information. Optimal Start, Accel, and Decel rate is 0.03g to 0.09g for a hydraulic elevator. (0.01g of acceleration or deceleration, applied for one second, results in a speed change of 19.3 feet per minute). Start The elevator acceleration is measured at the beginning of car motion. It is an indication of the force necessary to overcome packing, guide shoe, or other mechanical friction. An alert is generated if the Start exceeds a certain percentage of the Accel. An alert in this function indicates that either the acceleration is too abrupt or that excessive mechanical friction exists. Accel A measure of the acceleration immediately after the Start measurement. For the hydraulic elevator the Accel is controlled by the setting of the up acceleration or down acceleration on the control valve. Decel Measure of the rate of transition from high speed to leveling speed or stop, adjusted by setting the up transition and down transition adjusters on the control valve for the hydraulic elevator. Stop Measure of the stopping rate to the floor level. The stop is controlled by the braking action of the motor on a traction elevator; on hydraulic elevators it is affected by the settings of the up stop and down stop adjusters on the control valve. It is affected to some extent by hoistway friction issues. In the up direction, stop is also affected by the rate at which the hydraulic pump is brought to a stop and by the delay (or lack of it) between the de-energizing of the up leveling coil and the pump stop/time. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 5

Jerk A term used to describe a change in acceleration. When we ride in an automobile and feel a jerk, we are experiencing a change in acceleration of the vehicle in one or more directions. In mathematical terms one jerk is equal to a change in acceleration of one foot per second per second, in one second of time. One jerk equals a rate change of 0.03108 g s in one second. The jerk force displayed is the highest that occurs over the entire run. Optimal jerk is a value of 15.0 or less. Low Speed Test The SafeTach automatically shifts to low speed test mode if elevator speed remains below 20 fpm. This feature is used for verifying or setting the leveling speed, and for analyzing and setting up slow speed of elevator systems. To utilize the Low Speed Test function: Place SafeTach flat on the elevator floor. Run the elevator on inspection or slow speed until low speed test complete is displayed. The SafeTach will automatically recognize this test and will display the low speed. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 6

Save / RCL function The SafeTach has the ability to save and recall two different runs from active memory. Warning: Active memory is volatile so any saved runs are lost when SafeTach device is turned off. To save a run: Press the SAVE/ RCL button. SAVE AS and RUN A will appear. Press RUN A again to select RUN B. Press RUN B to select CURRENT. Press SAVE AS button to save the current run to the selected Run A or Run B. All previously saved information in the selected run will be overwritten with current run information. SAVE AS is not available in CURRENT. By saving then cycling through the run data in this manner you can compare the information for up to three runs (Run A, Run B, and Current). 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 7

USING THE SafeTach TO MAKE ADJUSTMENTS The following information is primarily applicable to hydraulic elevators. Use manufacturer recommendations in making controller adjustments. Precau on Rates should be measured and adjustments performed at low oil temperatures and with the car in an unloaded (or one rider) condition. As oil temperature increases the control valve responds more quickly. Control valve adjustment must be performed with the oil temperature above 80 degrees F, but not above the low end of the operating temperature range. ALERTS: WARM UP SCREEN PLACE FLAT ON FLOOR... Ready for placement (Flashing)... Warm-up bar... Ba ery level indicator (All Screens) As load is added to a car the acceleration rates will tend to increase. Control valve rate adjustments should not be changed with the elevator in a loaded condition, even if an alert is generated on the SafeTach. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 8

ALERTS: READY SCREEN PLACE CALL ( Flashing ).......... Ready to run elevator Flr (Flashing)............ Floor timer is activated ALERTS: DATA SCREEN FAST SLOW ( Flashing )... Rate, Jerk VERY fast ( Flashing )... Rate, VERY slow... Stop confirmation ( Flashing )... Leveling confirmation Limit ( Flashing )... Leveling time limit (15 sec) 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 9

The SafeTach is a performance metering device and will generate an alert for any measurement that falls outside the optimal range for that reading. Rate alerts are displayed as a flashing FAST or SLOW imposed on the label of the item generating the alert condition. It is possible to get multiple alerts generated in a single run. Each successive SafeTach measurement is dependent on previous measurements during that run. The following is the sequence of the measurements displayed by the SafeTach during a run: Accel g's Start g's/ Breakaway Run Time Jerk High Speed High Time START g s ACCEL g s HIGH SPEED DECEL g s LEVELING TIME STOP g s / LEVELING SPEED (display simultaneously) JERK (generated by the event of maximum jerk for the entire ride) Decel g's Leveling Speed Leveling Time Stop g's Example Elevator Speed / Rate / Time / Jerk Profile 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 10

When a poor ride generates multiple alerts, the alert conditions should be corrected in the order in which they occurred: Example: An elevator stop condition with a decel rate exceeding 0.10 g s / second will generate a FAST alert message for decel rate, and a FAST alert message for jerk (jerk alert). In this case correcting the condition which causes the abrupt decel will also correct the jerk alert. Example: If the leveling time exceeds 15.0 seconds, or if the SafeTach does not sense an elevator stop, a " Limit (time limit) alert message is generated. There are several electrical control and physical conditions, which could result in long leveling time. These need to be evaluated before control valve level adjustment changes are made. The experienced hydraulic elevator technician will find that all alert generating conditions are within his ability to control and modify. The following pages give examples of alert conditions, and the items to check to resolve these conditions, for hydraulic elevators in general (generic), and for elevators with Maxton hydraulic control valves installed. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 11

Generic Hydraulic Controller Fast Alert - items to check: Start Accel Level Decel Jerk - bypass sizing - packing tight - guide shoes tight - acceleration adjustment - leveling speed adjustment - transition adjustment - slowdown distance - any motion change that exceeds 15.0 in Jerk force Slow Alert - items to check: Accel Level Decel - acceleration adjustment - pilot fluid restriction - relief not set (up only) - leveling speed low - transition adjustment - slowdown distance 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 12

Maxton Hydraulic Controller Fast Alert - items to check: Start Accel Level Decel Jerk - reset BPS per procedure - packing tight - guide shoes tight - turn IN on UA (up), or DA (down) - turn IN on UL (up) or DL (down) to slow car to less than 12'/minute - turn IN on UT (up) or DT (down) to slow transition - check slowdown distance (2" for each 10'/min car speed) - any motion change that exceeds 15.0 in Jerk force Slow Alert - items to check: Accel Level Decel - turn OUT on UA (up), or DA (down) - check up-strainer for clog - relief (R) not set (up only) - turn OUT on UL (up) or DL (down) - turn OUT on UT (up) or DT (down) - check slowdown distance (2" for every 10'/min. car speed) 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 13

TROUBLESHOOTING CONDITION / DISPLAY Elevator stopped, Hi Time not displayed Elevator stopped, Leveling Speed not displayed, Leveling Time increasing. (Hydro Elevator) Elevator stopped, Leveling Speed displayed, Leveling Time stopped, Run time increasing. (Hydro Elevator) CAUSE Stable Hi Speed was not achieved. Stable Leveling Speed was not achieved. Up stop or down stop is set too soft. Elevator stopped, Leveling Time increasing. (Traction Elevator) Hi Speed was less than the traction elevator threshold, and stable Leveling Speed was not achieved. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 14

TROUBLESHOOTING CONDITION / DISPLAY Elevator stopped, no Leveling Time, no Leveling Speed, with Stop Hand indication. (Traction Elevator) CAUSE Leveling Speed and Time are not reported when the SafeTach senses a traction elevator. (normal condition) Elevator moving, Limit displayed, No Stop g reported. Information Runs Away before a call is placed. Start g >.01 and Accel g =.00, or Fast alert on Start g. Any Fast or Slow alert. Excessive Leveling time (over 15 sec). Leveling speed too slow or slowdown distance is too long. SafeTach not Placed Flat within 60 seconds of power on - false trigger. (Car movement, or the car was moving when the SafeTach was reset, or the SafeTach was moved during the reset). Breakaway problem, or Hi Speed was achieved in 3/4 second or less. Reading is not in the optimal range. See Using the SafeTach to make Adjustments for more details... pages 7-12 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 15

CAUTIONS & WARNINGS Be careful not to get the unit wet: Do not expose to rain or moisture. Do not immerse the unit in liquid. Do not drop, shake nor strike the unit: Malfunctions and inability to obtain readings may result from damage to the electronic circuits and components. Keep unit away from magnetic fields: A strong magnet may erase or disturb the memory of the unit, causing malfunction, or failure of the unit to function. Keep the unit out of a hot environment: Never expose the batteries or instrument case to temperatures above 150ºF (66ºC). Do not expose to direct sunlight, or store inside a closed vehicle parked in the sun. If a surface is too hot to touch, it is too hot for the SafeTach. The RJ11 port on the face of the SafeTach is for a wired remote device. Connecting a phone jack to this port may damage the equipment. Equipment modifications are not approved, and may damage the equipment. SPECIFICATIONS Operating temperature: 40ºF to 120ºF Operating voltage: +3vdc (4 x AA alkaline batteries) Dimensions: 7" x 7" x 2.75", with soft case Weight: 1.0 lbs. Measurement Accuracy Speed + / - 1 fpm + / -.005 M/S Force + / - 0.01g s + / - 1 milli-g s This equipment has been tested and found to be compliant with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. CALIBRATION The SafeTach is factory calibrated for the life of the unit. Each time the SafeTach is energized or reset it checks and adjusts to local gravity. This ensures that acceleration rates are sensed to a very high degree of accuracy. Barring physical damage to the unit, state-of-the-art electronic circuitry ensures the SafeTach never needs re-calibration. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 16

CLEANING INSTRUCTIONS To clean the SafeTach and its case use only a soft cloth dampened with a mild household dish washing liquid, or similar cleaner known to be safe for use on ABS and Mylar plastics. Do not use paper towels, solvents, acetone, paint thinners, or other petroleum products to clean the SafeTach; damage may result. LIMITED WARRANTY Maxton warrants that the SafeTach is free from defects in materials and workmanship for a period of one (1) year from the date of purchase. Any SafeTach unit that is determined by Maxton to be defective in material or workmanship, and returned to Maxton, shipping costs prepaid, as exclusive remedy within the warranty period, will be repaired or replaced, at Maxton s option. Physical damage or damage resulting from using incorrect cleaning products is not covered by warranty. The warranty is void when service or repair is performed by a non-authorized individual or service company. Maxton makes no warranty of any kind, express or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose. In no event shall Maxton be liable for indirect, special or consequential damages. For service contact Maxton for material return authorization. 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 17

NOTES 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 18

NOTES 1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com 19

1728 ORBIT WAY - MINDEN - NEVADA - 89423-4114 - PHONE 775-782-1700 - FAX 775-782-1701 - WEB: maxtonvalve.com - email: info@maxtonvalve.com