Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Similar documents
Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

CONDUIT BODIES CONDUIT BODIES. Phone:

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Conduit Bushings for Rigid Metal Conduit and IMC

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Applications. Standard Materials

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

EPOXY POWDER COATED COPPER FREE ALUMINUM

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

General Cable Support Information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Spring-loaded cover seats against neoprene gasket.

Junction Boxes Hazardous and Non-Hazardous

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Condulet Conduit Bodies and Outlet Boxes Hazardous

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Cable Connectors & Conduit Sealing Bushings

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Condulet Cast Device Boxes and Covers Application and Selection

Enclosures. Section E

Lighting: Explosionproof Area HID. Applications. Standard Materials

Applications. Illustrated Features

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Cable Connectors & Conduit Sealing Bushings

Plugs and Receptacles: Hazardous Location

W-Series Junction Boxes

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

ALUMINUM OUTLET BODIES

Taxonomies, Classifications, and Categories MYER'S HUB, 3-PIECE COUPLINGS, THREADLESS COUPLINGS AND THREADLESS CONNECTORS

Division 2 Contender Series Factory Sealed Control Stations

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Commercial Products. New Products in the Commercial Products Product Line

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Corrosion Protection for Electrical Conduit and Fittings

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Applications. Standard Materials. Certifications and Compliances

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

EDS / EFS Series Control Stations

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Areamaster LED Flood/High Bay Luminaires

Weatherproof Products

EDS / EFS Series Control Stations

Device Utility Finished FS Gang Conduit Bodies and Covers KO Seals Reducing Washers

Rigid Metal Conduit, IMC or EMT K-Clamps

CP Myers Hubs. Class I, Div. 2 Class II, Div. 1 and 2 Class III. when installed in accordance with the NEC. Features. Material.

Applications. Standard Materials. Certifications and Compliances

Thin Wall Conduit Fittings (For EMT Conduit)

Transcription:

For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit. NEC/CEC Suitable for use in the following Applications Serve as pulling fittings. Make bends in conduit system. Provide openings for splicing. Connect and change direction of conduit runs. Allow connections for branch runs. Permit access to conductors for maintenance. Features Roomy interiors: more wiring space. Smooth, rounded integral bushings in hubs protect conductor insulation. Accurately tapped, tapered threads for tight, rigid joints and excellent ground continuity. Form 85 copperfree aluminum Unilets are lightweight, selfoxidizing, self-renewing and offer a high corrosion resistance. Lightweight aluminum facilitates shipping, handling and installing. Sizes with flat-back design ideal where fitting is mounted flat against surface. 1/2" to 3" blank covers are domed for extra wiring space. Raintight when a cover and gasket are installed. Standard Materials Bodies: copperfree (max. 4/10 of 1%) aluminum 1/2 thru 2 : pressure cast 2-1/2 thru 4 : sand cast Blank covers: malleable iron, steel or copperfree (max. 4/10 of 1%) aluminum Cover screws: stainless steel Gaskets: neoprene or composition fiber Standard Finishes Aluminum bodies: epoxy powder coat Stamped aluminum covers: natural finish Cast aluminum covers: epoxy powder coat Options PVC coating available on all threaded bodies and select covers. Add suffix -PVC to catalog number. NEC/CEC Certifications and Compliances UL Standards: 514A, 514B UL Listed: E2527 CSA Standard: C22.2 No. 18.3 CSA Certified: 065183 NEMA Standard: FB-1 Related Products For explosionproof conduit outlet bodies and boxes, see Enclosures and Junction Boxes in Protection and Control of Electrical Apparatus and Circuits Catalog. Conduit Body with Stamped Aluminum Cover. 2 C shown. Typical Form 85 Conduit Bodies with s. For use with Electrical Metallic Tubing (EMT). 43

for use with Rigid Metal Conduit and IMC; for use with Electrical Metallic Tubing (EMT). NEC/CEC Suitable for use in the following Appleton Form 85 Conduit Bodies: /SetScrew C E 1/2 C-50A C-50TA E-50A E-50TA 3/4 (3) # 6 C-75A C-75TA (3) # 6 E-75A 1 (3) # 4 C-100A C-100TA (3) #6 E-100A 1-1/4 (3) # 2 C-125A C-125TA 1-1/2 (3) # 1/0 C-150A C-150TA 2 (3) # 3/0 C-200A 2-1/2 (3) 300 C-250A 3 (3) 300 C-300A 3-1/2 (3) 350 C-350A 4 (3) 350 C-400A LR T 1/2 LR-50A LR-50TA T-50A T-50TA 3/4 (3) # 6 LR-75A LR-75TA (3) # 6 T-75A T-75TA 1 (3) # 4 LR-100A LR-100TA (3) # 4 T-100A T-100TA 1-1/4 (3) # 2 LR-125A LR-125TA (3) # 2 T-125A 1-1/2 (3) # 1 LR-150A LR-150TA (3) # 1 T-150A 2 (3) # 2/0 LR-200A LR-200TA (3) # 2/0 T-200A 2-1/2 (3) 300 LR-250A (3) 300 T-250A 3 (3) 350 LR-300A (3) 300 T-300A 3-1/2 (3) 350 LR-350A (3) 350 T-350A 4 (3) 350 LR-400A (3) 350 T-400A Refer to following page for Wiring Capacity Table. All 1/2 Max Wire Fill Calculations per the NEC - Annex C - Table C8. 44

for use with Rigid Metal Conduit and IMC; for use with Electrical Metallic Tubing (EMT). NEC/CEC Suitable for use in the following Appleton Form 85 Conduit Bodies: /SetScrew LB LL 1/2 LB-50A LB-50TA LL-50A LL-50TA 3/4 (3) # 6 LB-75A LB-75TA (3) # 6 LL-75A LL-75TA 1 (3) # 4 LB-100A LB-100TA (3) # 4 LL-100A LL-100TA 1-1/4 (3) # 2 LB-125A LB-125TA (3) # 2 LL-125A LL-125TA 1-1/2 (3) # 1/0 LB-150A LB-150TA (3) # 1 LL-150A LL-150TA 2 (3) # 4/0 LB-200A LB-200TA (3) # 2/0 LL-200A LL-200TA 2-1/2 (3) 300 LB-250A (3) 300 LL-250A 3 (3) 400 LB-300A (3) 350 LL-300A 3-1/2 (3) 500 LB-350A (3) 350 LL-350A 4 (3) 500 LB-400A (3) 350 LL-400A TB X 1/2 TB-50A X-50A 3/4 (3) # 6 TB-75A (3) # 6 X-75A 1 (3) # 6 TB-100A (3) # 4 X-100A 1-1/4 (3) # 6 TB-125A 1-1/2 (3) # 4 TB-150A 2 (3) # 1/0 TB-200A 2-1/2 3 3-1/2 4 Back Style for Form 85 Unilet Conduit Body Sizes Unilet Body Flat Back Round Back C, LB, LL, LR, T 1/2 2 2-1/2 4 TB 1-1/4, 1-1/2 1/2, 3/4, 1, 2 E, X 1/2 1 Refer to following page for Wiring Capacity Table. All 1/2 Max Wire Fill Calculations per the NEC - Annex C - Table C8. 45

Covers Furnished with Stainless Steel Fastening Screws. NEC/CEC Suitable for use in the following Covers and Gaskets Body Size Blank Stamped Aluminum Blank Cast Aluminum Neoprene Composition Fiber Domed: 1/2-3 Flat: 1/2-2 Flat: 3-1/2-6 Domed: 2-1/2-4 Tear out inner section to convert to open type gasket. 1/2 K50-A K50-CA GK50-N GK50-V 3/4 K75-A K75-CA GK75-N GK75-V 1 K100-A K100-CA GK100-N GK100-V 1-1/4 K125-150-A K125-150-CA GK125-150-N GK125-150-V 1-1/2 K125-150-A K125-150-CA GK125-150-N GK125-150-V 2 K200-A K200-CA GK200-N GK200-V 2-1/2 K250-300-A K250-300-CA GK250-300-N GK-250-300-V 3 K250-300-A K250-300-CA GK250-300-N GK-250-300-V 3-1/2 K350-400-A K350-400-CA GK350-400-N GK-350-400-V 4 K350-400-A K350-400-CA GK350-400-N GK-350-400-V Wiring Capacity: Combine Body and Cover Capacities for Total Usable Capacity per NEC 314.16(A) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Capacity dm 3 (in 3 ) C E LB LL LR LRL T TA TB X Stamped Cover Cast Cover 2.34 (143.00) 2.95 (180.00) 4.97 (303.00) 5.57 (340.00) 2.28 (139.00) 2.90 (177.00) 4.92 (300.00) 5.41 (330.00) 3568.7 (140.50) 2.87 (175.00) 4.92 (300.00) 5.41 (330.00) 2.39 (146.00) 3.03 (185.00) 5.15 (314.00) 5.65 (345.00) 0.10 0.21 (13.00) (34.50) 1.16 (71.00) (0.50) (0.80 1.00 (25.4) 0.04 0.04 (6.50) 0.29 (18.00) 0.29 (18.00) 0.00 (0.00) 0.00 (0.30) (0.50) (0.80) (0.80) 0.02 (1.00) 0.49 (30.00) 0.49 (30.00) 0.82 (50.00) 0.82 (50.00) Add suffix -PVC to catalog number. 46

For Rigid Conduit & IMC. NEC/CEC Suitable for use in the following Applications To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90 bends. Features Tapered threaded hubs (NPT). Packaged complete with cover and gasket under one Catalog Number. Ready to use. Standard Materials Conduit Body: copperfree (max. 4/10 of 1%) aluminum Cover: BS copperfree (max. 4/10 of 1%) aluminum Gasket: SGN Neoprene Standard Finishes Conduit Body - epoxy powder coat enamel NEC/CEC Certifications and Compliances UL Standards: 514A UL Listed: E-18095 CSA Standard: C22.2 No. 18 CSA Certified: LR-9795 NEMA Standard: FB-1, FB-2.10 LB-ACGA T-ACGA LL-ACGA LR-ACGA C-ACGA 47

For Rigid Conduit & IMC. NEC/CEC Suitable for use in the following Appleton Form 85 : Complete with Cover LB-ACGA T-ACGA LL-ACGA 1/2 LB-50ACGA T-50ACGA LL-50ACGA 3/4 (3) # 6 LB-75ACGA (3) # 6 T-75ACGA (3) # 6 LL-75ACGA 1 (3) # 4 LB-100ACGA (3) # 4 T-100ACGA (3) # 4 LL-100ACGA 1-1/4 (3) # 2 LB-125ACGA (3) # 2 T-125ACGA (3) # 2 LL-125ACGA 1-1/2 (3) # 1/0 LB-150ACGA (3) # 1 T-150ACGA (3) # 1 LL-150ACGA 2 (3) # 4/0 LB-200ACGA (3) # 2/0 T-200ACGA (3) # 2/0 LL-200ACGA LR-ACGA C-ACGA 1/2 LR-50ACGA C-50ACGA 3/4 (3) # 6 LR-75ACGA (3) # 6 C-75ACGA 1 (3) # 4 LR-100ACGA (3) # 4 C-100ACGA 1-1/4 (3) # 2 LR-125ACGA (3) # 2 C-125ACGA 1-1/2 (3) # 1 LR-150ACGA (3) # 1/0 C-150ACGA 2 (3) # 2/0 LR-200ACGA (3) # 3/0 C-200ACGA All 1/2 Max Wire Fill Calculations per the NEC - Annex C - Table C8. 48

for use with Rigid Metal Conduit and IMC; for use with Electrical Metallic Tubing (EMT). NEC/CEC Suitable for use in the following Dimensions in Millimeters Pressure Cast 100.1 1/2 (3.94) 117.6 3/4 (4.63) 136.7 1 (5.38) 182.6 1-1/4 (7.19) 182.6 1-1/2 (7.19) 241.3 2 (9.50) Sand Cast 311.2 2-1/2 (12.25) 311.2 3 (12.25) 378.0 3-1/2 (14.88) 378.0 4 (14.88) s C, T, X s E, LB, LL, LR Dimensions In Millimeters A B C D E F G H J L M N P 33.3 (1.31) 39.6 (1.56) 46.0 (1.81) 63.5 63.5 79.5 (3.13) 109.5 (4.31) 109.5 (4.31) 139.7 (5.50) 139.7 (5.50) 35.1 (1.38) 41.4 (1.63) 47.8 (1.88) 87.4 (3.44) 98.6 (3.88) 117.6 (4.63) 131.8 (5.19) 141.2 (5.56) 120.7 (4.75) 143.0 (5.63) 1 (6.69) 217.4 (8.56) 217.4 (8.56) 274.6 (10.81) 384.3 (15.13) 384.3 (15.13) 460.5 (18.13) 460.5 (18.13) 65.0 (2.56) 76.2 (3.00) 50.8 (2.00) 57.2 (2.25) 66.8 (2.63) 106.4 (4.19) 146.1 (5.75) 146.1 (5.75) 181.1 (7.13) 181.1 (7.13) 52.3 (2.06) 62.0 (2.44) 71.4 (2.81) 98.6 (3.88) 96.8 (3.81) 115.8 (4.56) 133.4 (5.25) 173.0 (6.81) 182.6 (7.19) 104.9 (4.13) 124.0 (4.88) 166.6 (6.56) 163.6 (6.44) 211.1 (8.31) 301.8 (11.88) 293.6 (11.56) 355.6 (14.00) 349.3 (13.75) 109.5 (4.31) 130.3 (5.13) 200.2 (7.88) 200.2 (7.88) 258.8 (1) 347.7 (13.69) 347.7 (13.69) 419.1 (16.50) 419.1 (16.50) 16.0 (0.63) 19.1 (0.75) 23.9 (0.94) 26.9 (1.06) 30.2 (1.19) 38.1 (1.50) 46.0 (1.81) 55.6 (2.19) 63.5 28.7 (1.13) 35.1 (1.38) 42.9 (1.69) 54.1 (2.13) 60.5 (2.38) 74.7 (2.94) 85.9 (3.38) 104.9 (4.13) 120.7 (4.75) 130.3 (5.13) 79.8 (3.14) 96.0 (3.78) 114.3 (4.50) 204.7 (8.06) 270.0 (10.63) 270.0 (10.63) 333.5 (13.13) 333.5 (13.13) 26.7 (1.05) 32.3 (1.27) 38.6 (1.52) 57.2 (2.25) 57.2 (2.25) 93.7 (3.69) 93.7 (3.69) 124.0 (4.88) 124.0 (4.88) 49