XX 1.2 GI 12 VX DENSE WIDE ANGLE ARRAYS DWA 1.2 GI 12 V1 DWA 1.2 GI 12 V2 LONG RANGE ARRAYS LR 1.2 GI 12 V1 LR 1.2 GI 12 V2 LR 1.

Similar documents
SPSR-115/230. Self-Powered Sensor

SECTION LIFT ARM PARKING GATES

INSTALLATION INSTRUCTIONS FIBER OPTICS for INSIGHT II FLAME SCANNERS

SPSR-115/230. Self-Powered Sensor

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

E8P. OEM Optical Kit Encoder Page 1 of 9. Description. Mechanical Drawing. Features

PROFESSIONAL 270 o PIR MOTION DETECTOR

VOLTA suspension SPECIAL REQUIREMENTS T-3535

Photoelectric Sensors 55 Series

Heavy-Duty Probe Testers

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

Installation Manual GT500 GT500R RAB

Performance Summary. Product Description. Adjustable High and Low Modes High: 0 to 10V; Low: off to 9.8V

GUIDE 212.V3 VSD VERTICALLY INSTALLATION GUIDE. The Protector TM. Light Curtain Series 4694

Thru-Beam Photo Eye Monitored / Non-Monitored Battery Powered Emitter

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

REMOTE SENSOR SERIES. Description

AUTOMATIC PNEUMATIC BUMPER AND BREAK ACTUATION BEFORE COLLISION.

THE BEST PERFORMANCE IN ANY APPLICATION

The Pulsor. Phone: (800) (631) Fax: (631) Springville Road, Unit 3, Hampton Bays, New York 11946

BREAK-SAFE Load Break & Pick-up Tool

ULTRASONIC EXAMINATION

Compact Security FloodLight

Installation Instructions

Ultra Fast Earthing Switch UFES retrofit Overview

GRAVITY LED 7 HEADLIGHT & GRAVITY LED 7 PRO HEADLIGHTS

DE Down Light. Quick Facts. LED Down Lights. Straight Shroud

Data Sheet. HEDR-54xx Series Mid-Sized Housed Encoder. Description. Features. applications. Available Styles

BEARING MAINTENANCE. Mounting. Lubrication. Dismounting

Operator s Manual. Light & Laser Sight. GripSense

Vigilante Series. Wallpack. We light your world

PRODUCED WATER CANTY INFLOW WATER CUT METER MULTI-PHASE PARTICLE DISTRIBUTION (% OIL IN WATER, % SAND, % GAS) OiW

Description. Light transporters (straight) for S.M.D. LEDs. Bar Graph Arrays. Light transporters (right angle) for S.M.D. LEDs

V SERIES BRACKETS AND ACCESSORIES GUIDE. V SERIES Brackets and Accessories Guide Page 1

GT 710. Surface-Mounted, Low Energy, ADA*, Fire-Rated Swing Door Operator PRODUCT FEATURES

Fiat - Argentina - Wheel Aligner / Headlamp Aimer #16435

Cranes. OSHA Office of Training & Education 1

Vernier Motion Encoder System (Order Code: VDS-EC)

Ball Screws Inch Series

U060 LIGHTWAY INDEX GRAZERS WASHERS AMBIENT

26 BLK 71 WH. 71 WH LED 6,1W (3000K / Ang 120º / >80 CRI / 350mA) CUSTOM Universal Voltage (included) Accessories. Description.

IR Receivers: These parts detect IR light reflected from objects such as walls and people. This is useful for navigation.

WALL MOUNT - DIRECT/INDIRECT 0.25" Glo Lens 0.25"

8296 Portable Monitor Operating & Maintenance Instructions

TriLyte Multi-Application High-Performance T5/T8 Luminaire

Owner's Manual. Remote Security and Convenience System INS0866 8/98

High performance & light weight LED lighting

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

STANDARD PROCEDURE - FRONT LAMP AIMING

Optical Tables and Vibration Control. ND01 Series. Dimensions [in. (mm)] Model (Metric) A B ND01-A (M-ND01-A) 2.00 (50.0) 1.00 (25.

Auto-IR36/48 Door Mounted Presence Sensor INSTALLATION GUIDE

EL IPI with Serial Mux

Quartz One. Operators Guide. Pedestal. Vinten Camera Control Solutions

VEX Classroom Lab Kit to PLTW VEX POE Conversion Kit

photodiodes Description PerkinElmer Optoelectronics offers a broad array of Silicon and InGaAs PIN and APDs.

FRONT LAMP AIMING VEHICLE PREPARATION FOR LAMP ALIGNMENT

BREAK-SAFE Load Break & Pick-up Tool

Fabric Pulse Jet Collector Early Designs (Circa 1963)

In-Head Automatic Swing Door Operator DORMA. ED 200i

Elcometer 415. Coating Thickness Gauge. Operating Instructions

J TO 4000 LUMEN 8 LED CYLINDER HYPERBOLIC/PARABOLIC/WALLWASH OPEN APERTURE LC8 SERIES DIMENSIONS 1-1/4

Instruction Manual. Made in Israel Distributed by:

SLIM PROFILE STRIP LED SPS L

ISO INTERNATIONAL STANDARD

Solaris Light Pte Ltd

Ultrasonic Inspection Equipment for Al-Fin Insert Diesel Pistons

Flue Gas Analyzer IMR 1100F

Data Sheet. TitanTurbo TM Lamina Lighting Incorporated

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Accessories 286 SDC SECURITY DOOR CONTROLS

Detection of Red Dye in Diesel Oil

Photoelectric Sensors Comet Series

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics

HARDWARE ACCESSORY GUIDE

USERS GUIDE BODYGUARD III SMR PRESENCE SENSOR

Qty: Pole Order Code: Series Height Finish Options. R4 Type IV. R5R Type V Round. Distribution. Distribution. 4C Quadruple Cluster.

CAVA CURVE LED PENDANT DIRECT/INDIRECT W W W. L U M E N W E R X. C O M

Contents. Part no.: MLC500T Safety light curtain transmitter

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

REMOTE SENSOR SERIES. Description

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Operating instructions Bedienungsanleitung Mode d emploi

Eddy Current SURFACE ARRAY SOLUTION INTEGRATED SOLUT ION ENHANCED CAPABILITY.

STICTION/FRICTION IV STICTION/FRICTION TEST 1.1 SCOPE

126 Ridge Road Tel: (607) PO Box 187 Fax: (607)

ED-400 PORTABLE EDDY CURRENT UNIT

VISA Bottom Detail (cutouts backed by white acrylic) Confetti (CNF) Solid (SLD) Slots (SLT) Windows (WIN)

Talos Revolving Doors Talos Circular Sliding Doors

Elcometer 415. Coating Thickness Gauge. Operating Instructions

Application of Magnetic Particle Inspection in the Field of the Automotive Industry

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Installation design data for the 500SFK series fuse

Please consult factory for other lumen packages

High speed doors. Fast logistic solutions

USER MANUAL. Portable All-Condition Rugged PTZ Camera. (Thermal Imaging Version)

- Fact Table. Sheets SOLA COMPACT ULTRA 1.5 SOLA COMPACT. Version 01/ /14

NGAO OSM. Design Study. Alex Delacroix 08/05/2009 Version 9

Catalog Number. Notes

Transcription:

XX 1.2 GI 12 VX The lens arrays of Fresnel Technologies XX 1.2 GI 12 VX series are intended to be used in passive infrared motion detector devices. They are optimized for dual-element pyroelectric detectors. They are normally used with the grooved side facing the pyroelectric detector, and curved at a 1.2 inch (3.5 mm) radius about the sensitive area of the detector (see Figure 1). In this case, the detector and the lens array should be inclined downward at an angle of 12 degrees, for most of the types. The detector position should be.81 (2.6 mm) below the upper edge, and centered left-right (see Figure 2). The overall dimensions of the arrays are 1.677 ±.1 (42.6 mm ±.3 mm) high by 2.42 ±.1 (61 mm ±.3 mm) wide by.15 ±.4 (.38 mm ±.1 mm) thick. Border width is approximately 1/8 (3 mm). Centering is held to.15 (.38 mm) in both directions. Fresnel Technologies, Inc. is the premier manufacturer of Fresnel lens arrays. We have led the industry in the development of new lenses and materials to advance the state of the art of passive infrared motion detection. Our lenses and lens arrays have been incorporated into most passive infrared devices using refractive optics since 1976. Our quality standards are the highest in the industry. Surface finish and inclusions are such that no defect is visible at a distance of 3 feet (1 meter) under ordinary light. There are no functional flaws in our products whatsoever. Our POLY IR infrared-transmitting materials are the best available in stiffness and in transmittance in the 8 to 14 µm region. Active lens segments are made from our acclaimed and proprietary LODIFF lens patterns. Patents have been issued or are pending on each of the designs in the XX 1.2 GI 12 VX series. The members of the series are as follows: WIDE ANGLE ARRAYS WA 1.2 GI 12 V1 WA 1.2 GI 12 V2 WA 1.2 GI 12 V3 WA 1.2 GI 12 V4 WA 1.2 GI 12 V5 EXTRA WIDE ANGLE ARRAYS EWA 1.2 GI 12 V1 EWA 1.2 GI 12 V2 EWA 1.2 GI 12 V3 DENSE WIDE ANGLE ARRAYS DWA 1.2 GI 12 V1 DWA 1.2 GI 12 V2 LONG RANGE ARRAYS LR 1.2 GI 12 V1 LR 1.2 GI 12 V2 LR 1.2 GI 12 V3 PET IMMUNE ARRAYS WP 1.2 GI 12 V1 EWP 1.2 GI V1 ANIMAL ALLEY ARRAYS AA 1.2 GI 12 V1 AA 1.2 GI V1 AA 1.2 GI V2 AA 1.2 GI V3 VERTICAL BARRIER ARRAYS VB 1.2 GI V1 VB 1.2 GI V2 VB 1.2 GI 12 V1 Figures 3-3 illustrate the zone patterns for the arrays. The figures postulate a dual-element detector with 11 coverage both up-down and left-right, amplifier gain of about 5,, and a mounting height of 3.3 feet (1 meter) for the animal alley lens arrays and 6.8 feet (2.1 meters) for the others, and the 12 tilt for all arrays except the animal alley lens arrays. The AA 1.2 GI 12 V1 is designed to be used at a height of 3.3 feet (1 meter) from the floor, in a unit which retains the 12 downward tilt. The AA 1.2 GI V1 and the AA 1.2 GI V2 are designed to be used at a height of 3.3 feet (1 meter) from the floor, in a unit which is not inclined when mounted at this height but which is inclined downward 12 when mounted at the normal height of 6.8 feet (2.1 meters). The AA 1.2 GI V3 is designed to be used at a height of 3.3 feet (1 meter) from the floor in a unit which is not inclined downward at any mounting height. The VB 1.2 GI V2 is shown in a configuration useful for personnel detection near a door, with the detector mounted so it looks down at the floor. If you wish to use arrays from the XX 1.2 GI 12 VX series at a tilt angle other than 12, you should move the detector up.21 (.53 mm) for each degree less than 12, or down by the same amount for each degree greater than 12. The animal alley lens arrays discussed above are designed to be used at the angles specified, so that this movement is unnecessary. Other configurations (smooth side toward the detector, curved at other radii, tilted at other angles, etc.) can be used as well, but the zone patterns illustrated in Figures 3-21 will not apply. As examples, we offer Figures 24-29, some of which illustrate various XX 1.2 GI 12 VX series arrays curved at a 1.2 radius but not tilted downward 12, and others of which show them held flat. Other examples are available on request. f Copyright Fresnel Technologies, Inc. 29 www.fresneltech.com 9122

Detector Envelope Lensed Area (seen through lens array in normal use) 1.2in (3.m) Sensitive Area Grooved Surface (in normal use) Border Area FIGURE 1 12 Detector Envelope Sensitive Area WALL:.81in (2.6mm) 1.2in (3.m) Lens Array FIGURE 2

WIDE ANGLE ARRAY WA 1.2 GI 12 V1 2.6mm (.81in) 1 (49ft) 1m 88.6 1m 1 (49ft) 2. (8ft) 6m (2ft) 23m (75ft) Figure 3

WIDE ANGLE ARRAY WA 1.2 GI 12 V2 2.6mm (.81in) 1 (49ft) 1m 94 1m 1 (49ft) 3m (1ft) 6m (2ft) 23m (75ft) Figure 4

WIDE ANGLE ARRAY WA 1.2 GI 12 V3 2.6mm (.81in) 1 (49ft) 1m 94 1m 1 (49ft) 1m (3ft) 3m (1ft) 6m (2ft) 23m (75ft) Figure 5

WIDE ANGLE ARRAY WA 1.2 GI 12 V4 2.6mm (.81in) 1m 88.2 1m 1.7m 3.7m 7m 15.6m 18m (6ft) (12ft) (23ft) (51ft) (6ft) Figure 6

WIDE ANGLE ARRAY WA 1.2 GI 12 V5 2.6mm (.81in) 1 (49ft) 1m 9 1m 1 (49ft) 2m (7ft) 6m (2ft) 23m (75ft) Figure 7

DENSE WIDE ANGLE ARRAY DWA 1.2 GI 12 V2 2.6mm (.81in) 7m (23ft) 11 7m (23ft) 1m (3ft) 2.9m (1ft) 5.8m (19ft) 9m (3ft) Figure 8

DENSE WIDE ANGLE ARRAY DWA 1.2 GI 12 V1 2.6mm (.81in) 7.7m (25ft) 11 7.7m (25ft) 2.9m (1ft) 5.8m (19ft) 1m Figure 9

LONG RANGE ARRAY LR 1.2 GI 12 V1 2.6mm (.81in) 2.4m (8ft) 84 28 11.3 3m (1ft) 2.4m (8ft) 1m (3ft) 2.3m (8ft) 2.7m (9ft) 3m (98ft) Figure 1.

LONG RANGE ARRAY LR 1.2 GI 12 V2 2.6mm (.81in) 77 6m (2ft) 31 2 3m (1ft) 26 8.3 CL 3m (1ft) 6m (2ft) 1m (3ft) 2.2m (7ft) 3m (1ft) 13.2m (43ft) 23m (75ft) 28m (92ft) Figure 11

LONG RANGE ARRAY LR 1.2 GI 12 V3 2.6mm (.81in) 77 2. (8ft) 29 21.5 14 6.5 C L 2. (8ft) 5.m 1m (3ft) 2.2m (7ft) 3m (1ft) 1.7m (35ft) 18.3m (6ft) 3. (1ft) Figure 12

EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V1 2.6mm (.81in) 3m (1ft) 135 3m (1ft) 5.6m (18ft) Figure 13.

EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V2 42.6 mm 2.6mm (.81in) 1m 19.4 61 mm (2.4 in) 1m 1.7m (6ft) 4.6m (15ft) 7.7 m (25ft) 15.3m (5ft) Figure 14

EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V3 23.5 2.6mm (.81in) 1.2m 4.1m (14ft) 8.6m (28ft) 18.7m (62ft) (4ft) Figure 15

WIDE ANGLE ARRAY WP 1.2 GI 12 V1 2.6mm (.81in) 1 (49ft) 1m 88.5 1m 1 (49ft) 2m (6.5ft) 4. (15ft) 8.7m (29ft) 17m (55ft) 23m (75ft) Figure 16 22

Extra Wide Pet Immune EWP 1.2 GI V1 22.9m (75ft) 23mm (.9 in) 19.2mm (.8 in) 42mm (1.65 in) (2.4 in) 9.4m (31ft) 3.m (1.2 in) 121 3.5 mm R (1.2 in) 9.4m (31ft) 22.9m (75ft) 2.9m (9.5ft) 22 9.4m (31ft) 13.4m (44ft) 22.9m (75ft) Figure 17

ANIMAL ALLEY ARRAY AA 1.2 GI 12 V1 2.6mm (.81in) 9m (3ft) 1 9m (3ft) 1m (3.3ft) 12m (39ft) Figure 18

ANIMAL ALLEY ARRAY AA 1.2 GI V1 2.6mm (.81in) 1m 12 1m 12 1.m (3.3ft) 1 (49ft) Figure 19

ANIMAL ALLEY ARRAY AA 1.2 GI V2 2.6mm (.81in) 1. m (32.8 ft) (1.677in) 5. m (16.4 ft) 9 5. m (16.4 ft) 1. m (32.8 ft) 1. m (3.3 ft) 15. m (49 ft) Figure 2 1995

ANIMAL ALLEY ARRAY AA 1.2 GI V3 14.4mm (.567 in) 1. m (32.8 ft) (1.677in) 5. m (16.4 ft) 9 5. m (16.4 ft) 1. m (32.8 ft) 1. m (3.3 ft) 15. m (49 ft) Figure 21 1995

VERTICAL BARRIER ARRAY VB 1.2 GI V1 inactive areas 2.6mm (.81in) 5.6 7m (23ft) 44 18 1 (49ft) Figure 22

VERTICAL BARRIER ARRAY VB 1.2 GI V2 6 Typ. C L 6 Typ. C L 5' C L 2.4m (8ft) 2. 1m m 1m 2. (8ft) (3ft) (3ft) (8ft) Figure 23 1999

VERTICAL BARRIER ARRAY VB 1.2 GI 12 V1 inactive areas 2.6mm (.81in) 2.2m (7.2ft) 1.m (3ft) 2.m (6ft) 6.m (19ft) 9.m (29ft) 1. (34ft) 16m (52ft) 22. (73ft) AREA COVERED BY CYLINDRICAL LENS Figure 24.

WIDE ANGLE ARRAY WA 1.2 GI 12 V4 NOT INCLINED DOWNWARD 14.4mm (.56in) 1m 88.6 1m (6.9ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (3.m) but not inclined downward, and the detector centerline is at a distance of.56 inches (14.4mm) below the top edge of the top border. 2m 4m 7.1m 18m (7ft) (13ft) (23ft) (59ft) Figure 25

EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V3 NOT INCLINED DOWNWARD 14.4mm (.56in) 23.5 (16.4ft) (16.4ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (3.m) but not inclined downward, and the detector centerline is at a distance of.56 inches (14.4mm) below the top edge of the top border. 1.2m 4.1m (13.5ft) 8.6m (28.2ft) 18.7m (61ft) (3.9ft) Figure 26

LONG RANGE ARRAY LR 1.2 GI 12 V3 NOT INCLINED DOWNWARD 14.4mm (.56in) 77 2. (8ft) 29 21.5 14 6.56 C L 2. (8ft) NOTE:this drawing shows the pattern produced by this array when the array is curved at a radius of 1.2 inches (3.m) but not inclined downward, and the detector centerline is at a distance of.56 inches (14.4mm) below the top edge of the top border. 1m (3ft) 2.2m (7ft) 3m (1ft) 1.7m (35ft) 18.3m (6ft) 3. (1ft) Figure 27

LONG RANGE ARRAY LR 1.2 GI 12 V3 MOUNTED FLAT inactive areas 14.4mm (.56in) 2. (8ft) 27 21 14 6.6 C L 2. (8ft) NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (3.m) from the detector, but not inclined downward, and the detector centerline is at a distance of.56 inches (14.4mm) below the top edge of the top border. 1m (3ft) 2.2m (7ft) 3m (1ft) 6m (2ft) 18.3m (6ft) 3. (1ft) Figure 28

EXTRA WIDE ANGLE ARRAY EWA 1.2 GI 12 V2 MOUNTED FLAT 42.6 mm (1.675 in) 14.4mm (.56in) 59 53 46 61 mm (2.4 in) 8m (26ft) 39.6 4m (13ft) 4m (13ft) 8m (26ft) NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (3.m) from the detector, but not inclined downward, and the detector centerline is at a distance of.56 inches (14.4mm) below the top edge of the top border. 1.7m (6ft) 4.6m (15ft) 6m (2ft) 1 (5ft) Figure 29

ANIMAL ALLEY ARRAY AA 1.2 GI V1 MOUNTED FLAT 2.6mm (.81in) 8m (26ft) 41 4m (13ft) 36 4m (13ft) 8m (26ft) NOTE:this drawing shows the pattern produced by this array when the array is held flat at a distance of 1.2 inches (3.m) from the detector, but not inclined downward, and the detector centerline is at a distance of.81 inches (2.6mm) below the top edge of the top border. 1.m (3.3ft) 1 (49ft) Figure 3