P20, P21 Series Air Conditioning Limit Controls

Similar documents
A70, A72 Series Temperature Controls for Refrigeration and Heating

P10 Series Low Range Pressure Controls

Series P20 Pressure Controls for Refrigeration, Air-conditioning and Heat-pump Applications. Feature and Benefits. P20 Pressure Control

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

P70, P72, and P170 Series Controls for High Pressure Applications

T PI Receiver-Controller

P70, P72, and P170 Controls for Low Pressure Applications

P445 Series Electronic Lube Oil Control

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

P70, P72 and P170 Series Controls for High Pressure Applications

P66 Series Electronic Fan Speed Controls

C-5230 Pneumatic Signal Limiter

I ntroduction. N ote. Series P74 Differential Pressure Controls, without time delay. Feature and Benefits

V46 Series Pressure-Actuated Water-Regulating Valves

A25 Series Warm Air Control with Manual Reset

V-9502 Series Pneumatic Valve Actuator Positioners

AV-8020 Series Floating Control Actuated Valve

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

400 VMC Series. Compressor Manual Models: 440, 450, 450XL, and 460. Manufacturers of Industrial Refrigeration and Gas Compression Equipment

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

Powers TM Controls SW 141 Differential Static Airflow Switches

D-3240 Series Pneumatic Piston Actuators

Series P74 Differential Pressure Controls, without time delay

PP1 Series Piping Packages for VG1000 Series Ball Valves

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Section Va: Valve Actuators

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

Series Y63, Y64, Y65, Y66, and Y69 Transformers

F261 Series Fluid Flow Switches

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

System 350 P352AB Electronic Pressure Control Series

D-4070 Two Stage Pneumatic Actuator

t EVAPORATOR PRESSURE REGULATING VALVES

N-1001 Economizer Logic Network

RD-2000 Round Control Dampers

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

Features and benefits. Normally open, normally closed contact logic

611H Flo-Con Pressure Regulators & Valves

VA-8020 Floating Valve Actuator

BD-1600 Balancing/Zone Control Damper

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

V43xx and V243xx Series Repair Parts Kits

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

A11 Series Low Temperature Cutout Control

P545 Series Electronic Lube Oil Control

Product Catalogue. Electromechanical controllers REL

Flare Valves 1/2 inch 2-Way and 3-Way

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

VT Series Terminal Unit Valves 1/2 inch, 2-Way and 3-Way ANSI Class 250 Body Rating

Pressure Control Type KPU

Damper Actuator Installation

Powers Controls RL 147 Positioning Relay

Air Pressure Sensing Switch with Adjustable Set Point Range. Dimensions in Inches (Millimeters)

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

VSD Series II Variable Speed Micro Drives

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

FIELD DEVICES CONTROLLERS

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

Emerson Climate Technologies

PIPING PACKAGES TABLE OF CONTENTS

Crankcase pressure regulator Type KVL

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

TK-6024, TK-6124, TK-8024, TK-8124

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

ID-141x 12-Gauge Hat Channel Industrial Damper

OIL PRESSURE SAFETY CONTROLS

SDL Single-Duct, Low-Height, VAV Terminals

PRODUCT DATA DTG SERIES Unidirectional Filter Driers

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

M Ball Valve Linkage Kit

Flowrite AP 599 Series

Steel Suction Line Accumulators

Honeywell MP516A UNIT VENTILATOR DAMPER OPERATOR GENERAL DESCRIPTION APPLICATION SPECIFICATIONS OPERATION

Pneumatic Controls. Pneumatic Controls Sections

Zone Valves and Parts (Honeywell)

Manual Flushing. I nspection and Service

S-2300 Pneumatic Selector Switch

Fisher D4 Control Valve Assembly

Pressure Controls Product Overview

Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

PC-125x Counter-Balanced Backdraft Damper

Industrial Control Transformers

Bourdon Tube Pressure Switches

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

EP-8000 Series Electro-Pneumatic Transducers

Installation Instructions

Mueller 300 Ball Valves Industry-leading 300psi low lead ball valves

KEY PORT VALVE SERIES 400 ECCENTRIC VALVES Compact Size. Light Weight. UL Listed. AGA and CGA Approved. Bulletin

R-317 Air Flow Controller

THE BULLETIN 509 ASSEMBLY GUIDE - Features and Benefits

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

TSS Single-Duct VAV Terminals

Transcription:

Master Catalog 125 Pressure Controls Section P Product Bulletin P20, P21 Issue Date 0318 P20, P21 Series Air Conditioning Limit Controls Application These air conditioning limit controls are specially designed for package residential or commercial air conditioning units. They are for use with all non-corrosive refrigerants within pressure range of controls -- water or air cooled. They may also be used for refrigeration applications where a fixed range setting is acceptable. Models are provided for low side pressure, high pressure or dual pressure and may be supplied with automatic recycle or manual reset. Specifications Features Accurate repeat performance and long life. Test strength far above the most severe operating and standby conditions. Compact -- less than the size of a cigarette pack. Transmission of diaphragm movement is by a stainless steel power lever operating on a stainless steel pivot -- load aligned to reduce friction. Trip-free manual reset -- contacts cannot be blocked closed. Reset tab must be released before restart. Fig. 1 -- Single function control. Optional insulated terminal cover is shown. Controls for use on non-corrosive refrigerants. Enclosed dusttight Pennswitches. A dust gasket prevents sand, dirt and dust from lodging in the diaphragm and diaphragm push-pin area. Fig. 2 -- Low pressure and high pressure controls mounted on a common bracket (Series P21). 2018 Johnson Controls 1 Code No. LIT-125415

General Description Series P20 controls feature many desirable advantages not found in any other controls. Exclusive, service proved pressure element (about the size of a quarter) provides accurate repeat performance -- with substantial safety factor for long life under extreme operating and equalized standby pressures. Controls are compact and ideal for panel mounting and all applications where space is at a premium. (See Dimensions, Figs. 13 and 14.) The contact unit is the enclosed Pennswitch provided in SPST or SPDT actions (see Optional Constructions ). Both high and low pressure controls are factory adjusted to equipment manufacturers specifications for use on noncorrosive refrigerants and are not adjustable in the field. This provides a high pressure limit stop that meets UL requirements at no extra cost. Optional Constructions Capillary Standard 36 in. (914 mm) with.250 in. (6.35 mm) O.D.,.190 in. (4.83 mm) I.D., sweat section (Style 34). Available with reduced diameter and shoulder at extra cost, see Fig. 5. Also available with nut and flare (Style 13). Other lengths of capillary, maximum 60 in. (1524 mm), or variations supplied at extra cost. Minimum length is 36 in. (914 mm) when setting is over 100 lbs. Terminals 8-32 1/4 in. binder head screw terminals or single quick disconnect terminals, as specified, at same price. Double quick disconnect terminals may be supplied at no extra cost. Terminal Cover Molded black phenolic -- general purpose. Spring clip snap-on attachment. Insulating terminal cover (Part No. 210-604) available at extra cost when specified. Manual Reset (trip-free) Provided at extra cost when specified (see Type Number Selection ). Mounting Direct by two 6-32 tapped holes on 11/16 in. centers, see Figs. 13 and 14. Mounting bracket available at extra cost for single mounting (Part No. 210-25); choice of eight positions on single controls (Fig. 6). Bracket 211-1 for duals offers choice of four mounting positions (Fig. 7). Bracket 211-5 (upper left, Fig. 14) available at same price as 211-1. Electrical Jumper Supplied for dual controls when specified at extra cost. Contact Action SPST standard; SPDT also available at extra cost. Fig. 4 -- Type P20DA with quick disconnect terminals. Note the contrast in size between control and a six-inch ruler. 2 P20, P21 Product Bulletin

Repairs and Replacement Field repairs must not be made. For a replacement control contact the nearest Johnson wholesaler. Ordering Information 1. Specify Product Number and pressure setting. 2. If Product Number is not available, specify the following: a. Type Number, (see Specifications ). b. Range. c. Style of element. d. Cutout setting. e. Differential or differential option. f. Screw or quick disconnect terminals. g. Mounting bracket and bracket position if other than standard. h. Terminal cover, if required. i. Jumper on Series P21, if required. j. Packaging required. P20, P21 Product Bulletin 3

Standard Differential Options To convert psi to kpa multiply psi by 6.895 HOW TO USE DIFFERENTIAL OPTION TABLES Critical Setting: Ordinarily the critical setting on air conditioning limit controls (Series P20) is the cutout setting, but factory calibration will be made to either cut-in or cutout on original equipment manufacturers specifications. Tolerances on such settings are shown in the following tables. Opposite or non-critical operating point will then depend on choice of standard available differential options chosen from applicable table. Example: Suppose a high pressure cutout setting of 400 psig is required. Also suppose 325 psig cut-in is desired. Differential Option CM, Fig. 10, shows nominal differential of 75 psi at 400 psig cutout setting or a nominal cut-in of 325 psig. Note, also, that at 400 psig cutout, Differential Option BM gives a nominal cut-in of 350 psig; Option DM, a nominal cut-in of 292 psig. Also suppose a low pressure cutout setting of 40 psig is required. If a cut-in of 65 psig is desired, Differential Option CL, Fig. 9, should be selected to provide a nominal cut-in of 70 psig. Option DL at this setting would provide a nominal cut-in of 80 psig; Option BL a nominal cut-in of 62 psig, not high enough to assure coil defrosting on R-22 systems. 4 P20, P21 Product Bulletin

P20, P21 Product Bulletin 5

6 P20, P21 Product Bulletin

Performance specifications appearing herein are nominal and are subject to accepted manufacturing tolerances and application variables. UL Guide No. SDFY2 File SA516 P20, P21 Product Bulletin 7

Notes 8 P20, P21 Product Bulletin Building Technologies and Solutions 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls and PENN are registered trademarks of Johnson Controls in the United States of America and/or other countries. All other trademarks used herein are the property of their respective owners. Copyright 2018 by Johnson Controls. All rights reserved.