TECHNICAL BRIEF Americas

Similar documents
SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

G3PE-Single-phase. Solid State Relays for Heaters

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

Appendix UA Ideal Power UL 1741 SA Advanced Inverter Features

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

London Hydro Connection Checklist

How To AC Couple Grid Tied Inverters with OutBack Frequency Shifting Inverters

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

SA Power Networks Commissioning Witnessing Checklist

24. SOLAR INCENTIVE PROGRAM II

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

To complete the process for a net metering interconnection, please follow the steps below:

Purpose. Background. Exclusions

Bulletin Interconnection of electric power production sources Rules 2-010, , , , , , and

CHOCTAWHATCHEE ELECTRIC COOPERATIVE, INC RESIDENTIAL SERVICE--NET METERING RIDER

Generator Start Control Module

Generator Start Control Module

Solar-Powered Battery Bank

Table of Contents. Page 2. midlandusa.com. Model PPG100

Instruction Manual. OEM Frameless Rear View Replacement Mirror Monitor with 7.2" Dual Display RVS Reverse With Confidence 1

Inverter Advancements in UL1741 and UL 62109

Please read all of the installation instructions carefully before installing the product. Improper installation will void manufacturer s warranty.

On and Off Grid Interactive Features AC Coupling

To complete the process for a net metering interconnection, please follow the steps below:

Using Inverter Input Modes for Smart Grid Management

Generator Start Control Module

TERMS AND CONDITIONS

NET METER REQUEST FORM

Municipality Generator Interconnection Application Single Meter Application Part I

BC Hydro Rate Schedule 1289 Revision 1 Effective: April 20, 2018 Page 6-1

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined

UL1741 SA, Rule 21, and what it means for you. Josh Brister Sr. Manager, Product Management and Tech Sales

Instruction Manual. Backup Camera System With Replacement Mirror Display RVS N

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

10 Year Limited Warranty

Using Inverter Input Modes for Smart Grid Management

PowerFLEX Module Limited Warranty Program

What, Why, and Where? Brian Lips Senior Project Manager for Policy NC Clean Energy Technology Center

White River Electric Association, Inc. Net Metering Information & Service Requirements

To complete the process for a net metering interconnection, please follow the steps below:

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Net Metering Program

WOLFEBORO MUNICIPAL ELECTRIC DEPARTMENT NET METERING PILOT PROGRAM. Customer-Owned Renewable Energy Generation Resources (25 Kilowatts or Less)

Issue 23 draft for Nuvve

Impact of Distributed Energy Resources on Transmission System Reliability

NEW HAMPSHIRE ELECTRIC COOPERATIVE S (NHEC) ABOVE THE CAP NET METERING INTERCONNECTION APPLICATION INFORMATION

Users Guide for Ac-sync

Noble County Rural Electric Membership Corporation

Distributed Generation Interconnection Policy

7 MODES OF OPERATION INVERTER STATUS Standby: The PV string can only provide just enough voltage to minimum requirements of the controller.

City Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.

Vertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Power. On Your Terms.

Toro Sprayer Calibration Tool

WEB ENABLE ONLINE DATA LOGGER AND REMOTE MONITORING FOR 66 KW ON GRID SOLAR PV SYSTEM

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

How To Set Up SimpliPhi Batteries Using OutBack Chargers

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Model Number Structure

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

Battery System User Manual for Panasonic LJ-SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ-SK56A

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620

Productive. Reliable. Smart. Safe. Brandon J. Pierquet. The Impact of Microinverters in Photovoltaic Systems Enphase Energy

Pika Energy Island Made in America

Net Metering Interconnection Requirements

Southern California Edison Rule 21 Storage Charging Interconnection Load Process Guide. Version 1.1

30100 Module Installation Guide L

ELECTRIC DIVISION CUSTOMER-OWNED RENEWABLE GENERATION INFORMATION PACKAGE

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Instruction Manual. Backup Sensor Reversing System RVS-RS103

20250 Module Installation Guide

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

Installation & Operators Manual

END USER TERMS OF USE

Regenerative Utility Simulator for Grid-Tied Inverters

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Storage 101 for Installers + ESSENTIAL. QUESTIONS Integrating batteries in grid-tied solar PV system

Contactor Combiner Box Installation Manual

GENERATOR START CONTROL MODULE

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

GUIDELINES FOR OPERATING, METERING AND PROTECTIVE RELAYING FOR. NET METERED SYSTEMS UP TO 50 kw AND BELOW 750 VOLTS

15100 Module Installation Guide Mercedes EPA07 w/dpf

JEA Distributed Generation Policy Effective April 1, 2018

Transcription:

TECHNICAL BRIEF Americas Design Considerations When AC Coupling IQ Micros to Battery-Based Systems Overview AC coupling allows use of Enphase Microinverters with battery-based inverter systems. These applications require a grid-forming, battery-based inverter to create an intentional AC island to which the microinverters can export power. You can configure a system as an AC-coupled multimode system where the primary mode of operation is utility-interactive with alternate backup or stand-alone functionality. You can also create a stand-alone system and operate off-grid with no utility service present at any time. This configuration is often called a microgrid with AC coupling because the PV system, in this case the Enphase Microinverters and the battery-based inverters, are coupled on their AC outputs. In this application, Enphase Microinverters provide energy for the loads and charge the batteries of the battery-based inverter while the grid is unavailable. It is important that the battery-based inverter AC coupling function is enabled to prevent damage to the batteries. This document describes configuration considerations when AC coupling IQ Microinverters to third-party storage systems that use battery-based inverters operating in both utility interactive and backup applications. Microgrids are not covered in detail in this document. At the time of publication of this Technical Brief. the Enphase AC Battery and Enphase IQ Battery are not grid-forming. AC coupling of these storage solutions is not covered in this document. A battery-based application is generally more complex than a purely utility-interactive PV system and requires expert knowledge to be implemented successfully. Installers and designers must be qualified experts before working with battery-based systems and AC coupled systems. This document does not list all of the requirements and qualifications required. Benefits of AC Coupling Enphase Microinverters Grid-forming, battery-based inverters require a more sophisticated system design compared to traditional purely utility-interactive PV systems, however they can provide power for grid outages in emergency situations and for remote locations where no grid is present. Given the benefits of AC coupled systems, there are now a number of third-party storage solutions that use a bi-directional inverter to manage the battery storage independent of the PV system. Some of these third-party solutions are fully integrated inverters with storage chemistry, while others require the installer to select the inverter and to select and integrate batteries. Enphase Microinverters offer advantages over other inverter technologies when AC coupled to a batterybased inverter system. This is because a microinverter system is divided into AC branch circuits of a quantity of microinverters and PV modules that can provide a tapered charge to the batteries. IQ Microinverters provide additional functionality over previous microinverter generations including current- or frequency-based power curtailment when storage and load needs are satisfied, and broader voltage and frequency operating ranges that may be present in a fluctuating microgrid. These features allow for more flexibility for AC coupling than do PV string inverter systems. Enphase Microinverter systems can be AC coupled to a battery-based inverter system after installation, and the production capacity and backup or stand-alone loads can be increased or reconfigured to fit storage needs. Enphase Microinverters also offer the design flexibility, increased safety, and increased performance that come with module level maximum power point tracking (MPPT) and monitoring. 1 2018 Enphase Energy Inc. All rights reserved. March14, 2018

AC Coupling Configurations There are three common types of PV system interconnection modes and AC coupling configurations in which IQ Microinverters can be used. The following chart identifies how microinverter interconnection compliance, PV system curtailment (for battery safety), and load considerations are satisfied in the three different types of interconnection modes. Net energy metering: In this type of application the utility-interactive IQ Microinverters are able to export excess PV production to the grid, which generally results in some form of compensation from the utility. Export limiting: In this type of application, the utility allows a PV system to be operated so long as it does not export any PV production to the grid or keeps the PV production below a specific power level. Microgrid: In this type of application, there is no utility grid service and the IQ Microinverters interconnect to a microgrid formed by one or more generation sources. The primary difference between a utility interactive interconnection and off-grid / microgrid interconnection is that the microinverters are not subject to regulatory interconnection requirements. PV System Interconnection Modes Microinverter Interconnection Compliance Utility Interactive Local Interconnection Settings Utility Interactive AC Coupling Configurations Backup Local Interconnection Settings Off-Grid Off-Grid Net Energy Metering PV System Curtailment (for Battery Safety) Not Required Not Required For Battery Safety: 1) External Relay Control (full/partial) 2) Frequency/Trip 3) Frequency/Watt Load Considerations Annual energy use defines PV system size for maximum offset Annual energy use defines PV system size for maximum offset Backup Load Analysis: instantaneous power and desired backup period energy consumption define energy storage system size Microinverter Interconnection Compliance Local Interconnection Settings Local Interconnection Settings Export Limiting (zero export/ set limit) PV System Curtailment (for Battery Safety) Load Considerations Power Export Limiting (PEL) Annual energy use and daily load profile defines PV system (and optional energy storage system) size for best economic offset Power Export Limiting (PEL) Annual energy use and daily load profile defines PV and energy storage system size for best economic offset 1) External Relay Control (full/partial) 2) Frequency/Trip 3) Frequency/Watt Backup Load Analysis: instantaneous power and desired backup period energy consumption define energy storage system size Microgrid Microinverter Interconnection Compliance PV System Curtailment (for Battery and Generator Safety) Load Considerations Table 1: AC coupling configurations and integration considerations Microgrid-specific Interconnection Settings 1) External Relay Control (full/partial) 2) Frequency/Trip 3) Frequency/Watt Load Analysis: instantaneous power and desired operating period energy consumption define PV and energy storage system size 2

Net Energy Metering, Utility Interactive Example System Diagram Export Limiting, Utility Interactive Example System Diagram 3

Net Energy Metering, Utility Interactive with Backup Example System Diagram Export Limiting, Utility Interactive with Backup Example System Diagram Microinverter Interconnection Compliance The specific settings of the interconnection functions of the microinverters in an Enphase system are managed via grid profiles. Microinverters in North America ship by default with IEEE 1547 settings defined in the grid profile called IEEE 1547 default 2015. In geographies where this is the correct profile, you will not need to set this grid profile, but it is good practice to confirm that the correct settings are applied. Grid profiles contain all the settings for microinverter interconnection functionality and are defined in Enphase s Enlighten Manager web-based platform and set on the Enphase Envoy. You can also access these settings in the Enphase Installer Toolkit App for smartphones. This provides flexibility when unique settings are desired either onsite during the installation or remotely via Enlighten Manager. When the utility asks for proof that specific settings were applied, confirmation for each microinverter on the system is provided via the grid 4

profile report from either Installer Toolkit or Enlighten Manager. Note that the IQ Envoy propagates the grid profiles to the microinverters, so it is important to properly setup and connect an IQ Envoy to an Enphase Microinverter system. If the required grid profile is not available on the Enlighten Manager or Installer Toolkit pull down menu, please contact your Enphase Energy Field Applications Engineer to generate a customer grid profile. Net Energy Metering and Export Limiting Interconnection Compliance When utility-interactive microinverters are energized on an electric service, the local interconnection requirements define the voltage, frequency, and anti-islanding functions that inverter systems must comply with. These requirements are set by the authority having jurisdiction (AHJ). In most US states, a Public Utility Commission (PUC) governs the operating rules that the utility service providers must follow when approving interconnection of distributed energy resources, such as PV systems onto their distribution network. In the US and Canada these operating functions are defined by IEEE 1547, with certain additional local requirements such as California Rule 21 and Hawaii Rule 14H defined in a Source Requirement Document (SRD) and approved by the PUC. For a given microinverter model these functions are certified according to UL standards, such as UL1741 or UL1741-SA. In PV systems with Net Energy Metering (NEM) or defined export limits (zero export or specified export power limit), the interconnection operating functions of the microinverters are the same for utility interactive and backup / off-grid system configurations. For backup systems, the utility still specifies the interconnection functions, which are set on the microinverters via the grid profile settings. Microinverters continue to operate with these grid profile settings when isolated from the utility service during a grid outage and when AC coupled to the grid-forming, batterybased inverter. Therefore, the battery-based inverter in the off-grid operating mode must create a microgrid with voltage and frequency ranges within the microinverter interconnection settings if the microinverters are to operate. In this operating mode, the microinverters will generate the full available PV power into the microgrid, and either loads or the battery-based inverter must consume this generated PV power. If the available PV power is greater than the combined required power of the loads and battery-based inverter, then the microinverters need to be curtailed to protect the batteries from over charge and damage. As specified by the standard IEEE 1547, the inverter closest to the point of common coupling must comply with the local interconnection requirements. When microinverters are AC coupled on the backup loads panel of the system, it is the battery-based inverter that provides the local interconnection compliance. If this is the case, then you can set the microinverters with a grid profile that is optimized for backup / off-grid operation and battery charging. Microgrid Interconnection Compliance When AC coupling microinverters to a battery-based inverter in a purely off-grid or microgrid scenario, you have more flexibility to adjust the microinverter interconnection settings. The grid-forming, battery-based inverter must operate within the capability of a particular microinverter model, and you can set the grid profile on the microinverters to the desired microgrid-specific interconnection requirements. PV System Curtailment There are a number of options available for system integrators to ensure that the microinverters curtail output power when needed. External Relay Control You can use external relays to measure a source voltage or signal and trigger a contactor to disconnect microinverter AC branch circuits. You can design this to provide full or partial PV system disconnect and reconnect functionality. Keep in mind that local interconnection settings may have a reconnect timer when 5

the microinverters are returned to the AC grid. For example, IEEE1547 requires a five-minute reconnect period after a good AC grid source is detected before the microinverters can start producing power again. You can design relays to trigger on battery voltages, detect whether utility provided grid source is available, or trigger from a control signal provided by a battery-based inverter. AC Frequency / Trip All local interconnection settings have an over-frequency trip threshold that requires the microinverters to completely stop producing power. Many grid-forming, battery-based inverters have the ability to shift the operating frequency in off-grid mode when their batteries are fully charged. Setting the battery-based inverter over-frequency shift setting to a value above the microinverter system local interconnection frequency trip point, will cause the microinverters to completely stop producing power. When the battery-based inverter detects that battery charging is required again, it will lower the frequency. The microinverters then resume generation after the local interconnection compliance reconnect time setting, e.g., five minutes reconnect timer for IEEE 1547. This type of over-frequency trip function will work with IQ Microinverters and M- and S- Series microinverters. Example: Over frequency trip behavior 60.5 Hz per IEEE 1547 AC Frequency / Watt IQ Microinverters can gradually curtail power output based on the grid or microgrid AC frequency. This is often referred to as frequency / watt (frequency-based power control), or over frequency power limit. IQ Microinverters back off maximum power point voltage to reduce AC power output, based on the AC frequency. This causes no damage to the microinverters. Modern battery-based inverters have the ability to gradually change their frequency when operating in offgrid mode when the batteries are reaching a full charge. When this option is enabled on the grid-forming, battery-based inverter, you can set the IQ Microinverters to gradually decrease and increase power output accordingly. Example: Over frequency power limit (61.5 Hz start, ramp down rate 60 %/Hz) 6

The following settings define the IQ Microinverter over frequency power limit Start frequency in Hz (min 60, max 65) Start delay in milliseconds (min 0, max 10) Ramp down rate in %/Hz (min 40, max 83.33) Note that the local interconnection compliance requirements must allow this type of over-frequency operating behavior when the microinverters are interconnected to a utility-provided grid source. If these types of settings are not part of the local interconnection settings, you must use a different PV system curtailment method. Also note that frequency / watt curtailment settings may be used on the IQ Microinverters if all microinverters are interconnected on the load side connection of the battery-based inverter system. In this scenario, the battery-based inverter system must be set to comply with the local interconnection frequency settings and isolate the microinverters from the grid according to these. Power Export Limiting For systems interconnected to a utility service that requires an export limit, the PV system must limit the amount of power exported to the utility grid. This means that any PV generation, not consumed locally by loads and exported onto the grid, must be limited as defined by the utility interconnection agreement. This export limit could be zero, meaning no power is allowed to be exported, or a set power value, e.g., 5 kw or 10 kw. For example, let s take an 8 kw AC rated PV system that is operating at full output. If an export limit of 5 kw AC is required, and the loads in the building are only consuming 1.5 kw AC at a given time, the PV system must reduce its power output to 6.5 kw AC (8-1.5). The solution is for the PV system to measure the loads in the home via consumption metering and to limit the PV system exported power when needed. This functionality increases system sizes and provides a much better value to the customer. This export limit function is part of the Enphase Energy IQ system. To enable export power limiting, an IQ Envoy is equipped and installed with production metering and consumption metering. The IQ Envoy, based on the consumption meter and production meter data, calculates whether any PV generation above the set export limit is exporting to the grid. Then it automatically sends power curtailment commands to the microinverters via the powerline. No external communications equipment needs to be installed. Pulling data from the consumption meter every 500ms and making adjustments to microinverter output at 1.5s intervals, an IQ Envoy constantly reacts to power export limits in two to four seconds. Microinverter power output increases also occur in the same amount of time. This functionality is set through the grid profile and called Export Limit Soft Limit. 7

Example: Power export limiting - two second response time Some systems may require a secondary protection circuit in case the control function of the export limit fails. In that case, the normally opened contact within the IQ Envoy can drive a contactor to provide this secondary level of protection. If the IQ Envoy loses power, the external contactor opens and disconnects the AC source to the IQ Microinverters. 8

The following settings define the IQ Microinverter system Power Export Limiting Export limit Soft limit threshold in watts (min 0, max 30,000) primary IQ Envoy control function Export limit Hard limit (enabled / disabled) optional secondary protection via external contactor o Communication loss time limit in milliseconds (min 30,000, max 120,000) o Hard limit threshold in watts (min 0, max 30,000) o Hard limit response time in milliseconds (min 10,000, max 60,000) Exception: Microinverter systems set to zero power export limit may not produce power when AC coupled to third-party storage solutions to charge batteries. Until further notice we recommend to only AC couple microinverters when they have a total system power export limit greater than 100 W. Load Considerations Net Energy Metering Load Considerations Designing utility interactive NEM systems requires understanding annual energy consumption to determine the PV system size for maximum energy bill offset. Adding backup to a utility interactive NEM system requires a backup or stand-alone loads analysis. This includes identifying the desired stand-alone loads instantaneous power and desired backup period energy consumption to define the energy storage system capacity in watt-hours and battery-based inverter peak power output rating. Refer to design guidance provided by the manufacturer of the particular third-party storage system being used. Export Limiting Load Considerations Utility interactive systems with export limits require an analysis of the annual energy consumption and daily load profile to determine PV system size for self-consumption. You can size an optional energy storage system based on the daily load profile to increase self-consumption of the PV system energy production. Adding backup to a utility interactive system with export limits also requires a backup or stand-alone loads analysis. Refer to design guidance provided by the manufacturer of the particular third-party storage system being used. Microgrid Load Considerations Microgrids often contain power generation resources that are not battery- or PV-based. Designing microgrids requires a much more comprehensive load study to determine the capacities and system sizes of different power generation and energy storage resources. This document does not detail microgrid design. AC Coupling Safety and Design Considerations In all battery-based systems, there are requirements for safe and reliable operation. Additional safeguards when AC coupling Enphase Microinverter systems include: Do not allow the batteries to overcharge. Overcharging batteries can damage the batteries and can potentially cause fires and catastrophic meltdowns. It is smart to provide redundant methods to regulate the charge to the battery. Do not connect the Enphase Microinverters to the output of an engine generator without properly designed protection and transfer equipment. This can cause damage to the microinverters and the generator. Design the Enphase Microinverter system so that it does not exceed the pass-through capabilities of the battery-based inverter s charging system. 9

Whenever working with batteries, take precautions to ensure safety. This is particularly true for AC coupled systems because traditional inverter chargers and charge controllers are not designed to regulate the charge from an AC coupled system. Therefore, take precautions to ensure that the batteries are not overcharged. Use one of the PV system curtailment options described above. For additional battery protection, use a dump load to drain excess power out of the batteries in the case of overcharging. Do this by using some of the stored power to heat water or air with a listed and approved heating element. If an engine generator is present, do not connect the Enphase Microinverters to the same load panel as the generator without properly designed protection and transfer equipment. When using a generator to charge batteries in a battery-based inverter system, the battery-based inverter also internally bypasses the generator s output to the back-up / emergency load panel that the Enphase Microinverters are feeding. Allowing this connection can damage the generator and microinverters. Therefore, if using a generator to charge batteries, ensure that the Enphase Microinverters are shut off when the generator is running. The best method is to use a voltage-controlled relay activated by the generator panel. Use a transfer switch to ensure that the generator is always isolated from the Enphase Microinverters. Disclaimers No Guaranty as to Content of Information - The information in this application note is provided for general information purposes only and may not apply to a specific or particular situation or circumstance. While Enphase has made reasonable efforts to ensure that the information is accurate at the time of publication, information is constantly evolving, and the information provided does not purport to be correct, comprehensive or exhaustive. Enphase expressly disclaims any liability for any errors or omissions in any information published. Information Provided As-Is - The information contained in this application note is provided AS-IS and any representations do not constitute an express or implied warranty of any kind. Enphase makes no representations as to the completeness or validity of any information contained herein or the consequences arising from the use of or reliance on this information, and Enphase expressly and specifically disclaims all warranties, whether express or implied, written or oral, including, without limitation, the warranty of merchantability and the warranty of fitness for a particular purpose, provided, however, that nothing contained herein is intended to alter or revise limited warranties, if any, provided to purchasers of Enphase products or services at the time of purchase. Disclaimer of Liability - By accessing this application note, you acknowledge that you are accessing the information contained therein at YOUR OWN RISK and in your own discretion. Enphase disclaims all liability and shall not be liable to you for any damages to your person or property which may result from your use of this application note. Under no circumstances shall Enphase be liable for any claim arising from the use or misuse of this application note or any reliance on any information contained herein, including without limitation any claims for direct, indirect, incidental, consequential, special, exemplary or punitive damages, as well as attorney s fees or costs, regardless of whether such claims arise out of negligence, gross negligence, carelessness, recklessness, wantonness, fraud, misrepresentation or contract. 10