climaciat airtech Air handling units Air handling for all applications Climaciat Airtech The technological choice Performing to new standards

Similar documents
VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

This generation of shell and tubes evaporator has been designed for integration into high and medium power cooling systems.

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

This generation of shell and tubes evaporator has been designed for integration into high and medium power cooling systems.

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

NA F FLOWAY. Instruction manual

All solutions. Water chillers Heat pumps NA I

XeteX, Inc. All Rights Reserved.

39CZ. Air-handling unit PRODUCT SELECTION DATA

Heat recovery units type GTDHR

MODULAR AIR HANDLING UNITS GAH SERIES

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements

Complete HVAC Capability

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]


SECTION AXIAL HVAC FANS

high-power ally design Your from 230 to 1100 kw Forward-thinking PowerCIAT heralds a break in the way packaged water

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Air Handling Units. Geniox. Accessories

MAH. Modular Air Handling Unit

VALVES WITH SA ELECTRIC ACTUATOR

TSS Single-Duct VAV Terminals

Vacuum Cleaners Vacuum Manuals ASSEMBLY SCHEMATIC MODEL NO. C1810 FOR VACUUM CLEANER PARTS PLEASE CALL

CS3 Series 50/60Hz. Modular Central Station Air Handling Units Air Volume: 1000 to cfm (1700 to m 3/hr)

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

A strong point for your energy savings

A. This Section includes general duty valves common to several HVAC piping systems.

VALVE WITH UV ELECTRIC ACTUATOR

VAHU Vertical Air Handling Unit

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Swimming Pool CSR2 Heat Recovery Equipment

Bx OVEN ECOTOUCH CONTROL

XS VALVES WITH SA ELECTRIC ACTUATOR. Model/Ref:

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

Fan Coil Dimensional Data. ultimate fan coil system

ACCESSORIES FOR SZE2 CABINETS

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

XS VALVE WITH SA05 / SA-X05 ELECTRIC ACTUATOR. Model/Ref:

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

AIR-AIR ENERGY CONSERVATION MODULE

VALVES WITH UM ELECTRIC ACTUATOR

SDL Single-Duct, Low-Height, VAV Terminals

FAN POWERED TERMINAL UNITS

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

CCS Zone/Bypass Damper Assembly

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

VALVE WITH SA ELECTRIC ACTUATOR

SECTION CENTRIFUGAL HVAC FANS

Models: W30A2, W36A2. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

Ducted medium static pressure monosplit DC Inverter

DUNHAM-BUSH ecs3 Series

REPLACEMENT PARTS MANUAL

VALVES WITH UV ELECTRIC ACTUATOR

Low Profile. Introducing Payment Terminal Mounting Solutions

A I R C O M P R E S S O R S R O L L A I R E

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

NUCLEAR VALVES. Design, Manufacturing, Assembly and Testing

CURTAIN TYPE FIRE DAMPER

SPECIFICATION SHEET. C5000 ( cfm)

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Replacement Parts Catalog

AHN 064 to 304 EHN/CHN 064 to 304

XIII. Repair Parts 106

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

WCTA SERIES Air Handling Units. ( ,000 m 3 /h )

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Fan coil unit NBS 100/150

FORM NO. HSC-543 AIR HANDLERS

RAYPAK REPLACEMENT PARTS

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

PARALLEL STAY. Parallel Opening Hinge for Commercial Applications

YCCS Zone/Bypass Damper Assembly

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

YCCS Zone/Bypass Damper Assembly

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AKG 2009 (changes and errors expected) HC- series. Classic

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL. General Notes. Contents. Important MODEL: WH381 WH431 WH491

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GLOBAL STANDARD COOLER

Operating Instructions

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

1mm GALVANIZED PIPE SYSTEM

300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS

series FSD-FLD Fire and smoke dampers UL Approval

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Transcription:

Climaciat Airtech The technological choice Characteristics Casing strength Casing air leakage Filter bypass leakage Thermal transmittance Thermal bridge factor Class D2 L1-L2 F9 T2 TB2 Air flow: 1 000 to 66 000 m 3 /h Air handling for all applications An extended range of air flow equipment and an exhaustive selection of air-processing options make Airtech an efficient solution for applications in both the office and industrial sectors. The wide range of solutions available and the product s extensive modular design, as well as the various horizontal, vertical, stacked and side-by-side assembly formats for both indoor and outdoor use, provide solutions to meet every requirement. Performing to new standards Airtech air handling units have been designed in line with the EN 13053 manufacturing standard and with the aim of fulfilling the strictest EN 1886 standard grades: transmittance and thermal bridge, mechanical endurance and airtight jacket, filter bypass leakage, compliance with mechanical safety requirements for fans. CIAT has developed all the components and accessories (handles, safety latches, through-wall unions, inspection windows, seals) that give high performance, thanks to a special design that has become a reference in its field. 1

The next generation design Body l1 Dual-wall casing, pre-coated outer panelling, 50 mm thick insulation l2 At least one removable panel per function, as per EN 13053 l3 Smooth panel facing with no protruding internal screws, as per EN 13053 l4 Access panel as standard for maintenance-dependent functions l5 Off-centre hinge units and latch handles, all made from composite material for withstanding corrosion and l6 l7 temperatures from -40 C to +80 C Multi-purpose, ergonomic mounting blocks for easy handling, fitting, unit linkage, and air circulation around the panels; can also accommodate a control system Door seal system manufactured to a special profile and from special material. High-quality seal on irremovable panels is a factor in the structure achieving EN 13053 airtight classification l8 Large-diameter square inspection window is manufactured to EN 13053, with a dual-wall system and inner linkage bellows to reinforce the seal. Air inlet l9 Face-to-face damper louvres, cog-wheel drive system, Grade 3 tightness as per EN 1751 l3 l5 l9 l1 l2 l6 l5 Composite l5 Handle l13 Condensates hinge unit drain pan l14 Sealing flange l18 Adjustable drive-unit bracket 2

Filters Air handling units l10 Parallel gripped filter. Runners with clamping system (comply with EN 1886 class F9) l11 Pressure tappings at each level filtration Exchangers l12 Threaded connectors as standard up to 3 l13 Tilted condensates drain pan, as per EN 13053 l14 Sealing flange, fully airtight and thermal bridge free between piping and casing l15 l16 l17 l18 l19 Fans 3 available fan types: low pressure, medium pressure and freewheel, all in various sizes Fans are mounted on anti-vibration frame with spring-loaded pads as standard Flexible, inner fan-to-casing connection Motor mounted on self-aligned adjustable frame Fitted packing gland for electrical power supply l11 l12 l4 l8 l16 Anti-vibration pad l7 l14 l19 l10 Contracting filter runner l7 Seal gasket Airtech performance is built around the definitive filtration system Pre-filtration The filter mediums have been exclusively designed by CIAT to meet the most stringent quality requirements whilst also providing the tightest seal under the EN 1886 standard. The filter sliding rails with clamping system are mounted on a back frame and include an outer seal, guaranteeing excellent air tightness on the filter system. Terminal filtration Demands on terminal filtration performance were especially intense: - Double airtightness sealing for higher performance. - Separate panels prevent strain when work is being carried out inside the unit and also help to protect the outer seals. 3

A range of performance levels The Airtech range covers, in 11 sizes, airflows ranging from 1,000 to 66,000 m³/h. The following chart shows the required size based on: - The air flow rate through the front area exchanger coil assembly - The rate of air flow to be treated The diagrams show the types of layout with the operating limits of the components. Air heater (A), air conditioner without droplet separator (B), with standard droplet eliminator (C), with high speed droplet separator (D). Coil assembly air speed 4

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel. : 08 11 65 98 98 (0,15 / mn) Fax : 08 26 10 13 63 (0,15 / mn) Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114