Burners. High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev /11/2016)

Similar documents
Free flame burners EMB (E3004 rev /02/2015)

Burners. Metallic free flame burners. EMB (E3004 rev /02/2010)

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Burners. Self-recuperative burners high speed with flat flame REKO-SIK-SW (E3903 rev /06/2015)

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010)

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Burners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)

Radiant tube burners RT (E3900 rev /01/2018)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901FF rev /05/2009)

Orifice Flow Meters POP-S (E5720 rev /03/2013)

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

OIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:

Valves. Double stage and modulant motorized butterfly valves MRBV & MRBV-CMAP (E1302 rev /04/2011)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-S (E7021 rev /05/2015)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-PRS (E7022 rev /05/2015)

North American 4485 Tempest SE

2.0 Burner Operating Parameters and Requirements

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

KINEMAX. Medium velocity gas or oil burners

Electronics. Permanent Operation Microprocessor Burner Control ESA ESTRO-PO (E7014PO rev /05/2013)

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

Specifications of STICKTITE and PILOTPAK Nozzles

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

LVDT/HC PILOT BURNER. External raw gas pilot burner

Oil, gas and dual fuel burners. Burner series

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

North American 4575 HiRAM

1470 SERIES HOT AIR GAS BURNER

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

MULTIFIRE. High temperature dual fuel burner

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/M SERIES. Modulating Gas Burners FIRING RATES

US - UP2/OIL 12V US - UP2/OIL 24V

Oil, Gas and Dual Fuel Burners

ONE STAGE GAS BURNERS RDBS SERIES

Specifications of STICKTITE and PILOTPAK Nozzles

PREMIX TUNNEL BURNERS

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

1200 SERIES FTR HOT AIR BAFFLE BURNER

Eclipse RatioAir Burners

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

Doing more for clean environment and energy saving

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

NOx-Beta Ultra Low NOx Burners

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

VLF45... Hot Air Valves. Building Technologies Division

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

G72x Series Direct Spark Ignition Controls

Installation- and maintenance instruction ST120 S75/21

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

OPERATING INSTRUCTIONS MODE D EMPLOI GEBRAUCHSANLEITUNG INSTRUCCIONES PARA EL USO CENTER 200

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

E Series CE Approved Intermittent Pilot Ignition Control

RS Series Two Stage Progressive Gas Burners

Installation- and maintenance instruction BENTOFLEX ST 108 PL

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

PNEUMATIC PUMP Series

1466 SERIES COLD AIR GAS/OIL BURNER

Eclipse RatioAir Burners

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

NON-CONTACT TOOL BREAKAGE DETECTION SYSTEM

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

Installation- and maintenance instruction BENTOFLEX ST120KAV

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Mod: KLD6-12/35XLAS-N

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

TECHNICAL MANUAL MT029

INDUSTRIAL GENERATORS. steam or overheated water 97/23/CE - P.E.D. certified

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Modulating Furnace Information. Warning on Meter Setting - Read First!

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Light oil - kerosene burner

INSTALLATION AND MAINTENANCE

G76x Direct Spark Ignition Controls

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

North American Combustion Burners

available in battery up to 4 units for a total of 560 kw

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Transcription:

Burners High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev. 05-28/11/2016)

GENERAL WARNINGS: GENERAL NOTES: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocution, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. ¾ The perfomances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. DISPOSAL: To dispose of the product, abide by the local legislations regarding it. ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. ¾ The EMB-SIK-NxT products have been designed, manufactured and tested according to the most correct construction practices and following the applicable requirements described in UNI EN 746-2-2010 Industrial heating process equipment - Part 2: Safety requirements for combustion and for the handling and processing of fuels. We emphasize that the burners described in this data sheet are provided as independent units and are excluded from the scope of the Machine Directive 2006/42/EC not having any mobile items that are not exclusively manual. ¾ Certified in conformity with the UNI EN ISO 9001 Norm by DNV GL. ¾ For ESA-PYRONICS, the NxT symbol has the following two meanings which are connected to each other: NEXT GENERATION, or new generation burners that maintain functionality, reliability and performance. NOx TECHNOLOGY energy saving and low polluting emissions. Headquarters: Esa S.p.A. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it CERTIFICATIONS: The products conform to the requests for the Euroasia market (Russia, Belarus and Kazakhstan). CONTACTS / SERVICE: www.esapyronics.com International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com 2

The EMB-SIK-NxT burners are nozzle mix type burners; the combustion agent and fuel are mixed at the combustion head avoiding dangerous flame backfire. The air flow together with the shape of the silicon carbide head produce a tight flame that allows high heat penetration inside the combustion chamber. ¾Fibre coated furnaces ¾Ceramic furnaces ¾Treatment furnaces ¾Tunnel furnaces ¾Chariot furnaces APPLICATIONS F3010I03 CHARACTERISTICS GENERAL: ¾Functioning with preheated air: from 200 C to 500 C ¾Capacity:: from 100 to 700 kw ¾Air and gas pressure to the burner: 50 mbar ¾Operation with various types of gas: CH 4 /GPL Propane/etc... ¾Technology: NxT ¾Flow rate ratio: 1:5 ¾Easily replaceable electrodes. ¾Burners with micrometric gas regulator, ignition and detection electrodes, peepsights, calibrated inserts and prerssure outlets for measuring the combustion air and fuel gas ratios. Material Composition: ¾Mixer body: ¾Collector: ¾Flame holder tube: ¾Combustion head: ¾Fixing flange: cast iron G25 cast iron G25 silicon carbide AISI310S iron F3010I04 www.esapyronics.com 3

CAPACITY PARAMETERS AND FLAME LENGTH EMB-SIK-Nxt burner flame ignition and detection take place using two separate electrodes; both are included in the supply. The adoption of flame control systems is highly recommended in all plants operating at temperatures below 750 C (UNI EN746/2 Norm). Model Potential kw DESCRIPTION Flame length mm Ignition / Detection EMB-3-SIK-NxT 100 900 ESA WAND EMB-4-SIK-NxT 180 1250 3EN EMB-5-SIK-NxT 250 1600 3EN EMB-6-SIK-NxT 450 1800 3EN EMB-7-SIK-NxT 700 2300 3EN The EMB-SIK-NxT burners are LOW NOx and apply the most recent technical expertise to ensure low NOx and CO emissions, yet remaining functional even at low chamber temperatures during ignition when the plant is cold. The burners are solid and robust with small weight and dimensions (main insulation is in ceramic fibre), with separate air and gas inlets and mixing at the nozzle (no flame flashbacks). EXHAUST STRONG RECIRCULATION D3507I01 Multistage combustion technology, together with strong recirculation of flu gases, guarantees low NOx and Co emission even with preheating air temperatures as low as 600 C. www.esapyronics.com 4

BLOCK HOLDER BURNER VERSION (EMB-SIK-NxT-BH) The EMB-SIK-NxT-BH are gas burners used for direct heating. These burners allow excess air, stoichiomentric and excess gas regulation. Depending on the size and use, this type of burner can be used for natural gas and LPG combustion (in the standard version) and other types of gaseous combustive agents with heating different properties (special versions on request). The burner is provided with concrete block holder for special high temperature application such as: ¾Annealing lines. ¾NOx galvanizing lines. ¾Ceramic furnaces or fibre cover treatment furnaces. ¾Tunnel or car bottom furnaces. ¾Dryers. ¾Stretching furnaces. ¾Treatment furnaces. F3507I05 GENERAL: CHARACTERISTICS ¾Temperature limit: 1.400 C ¾Air and gas pressure to burner: 50mbar ¾Flow ratio: 5 : 1 ¾Flame speed: up to 120m/s ¾Excess air: up to 400% ¾Excess gas: up to 20% ¾Preheated air up to: 600 C MATERIAL COMPOSITION: ¾Mixer body: Cast iron G25 ¾Gas collector: Cast iron G25 ¾Flameproof tube: SiC ¾Combustion head: AISI310 ¾Fixing flange: Fe ¾Refractory block: T.max 1750 C F3004I06 www.esapyronics.com 5

BURNER PERFORMANCE The capacity, lengths and flame speed refer to burner fueled by natural gas (8600 Kcal / Nm3), located in the combustion chamber at zero pressure above sea level, working with 10% excess air. ¾MIN/MAX (ON/OFF) functioning ¾Chamber temperature1200 C ¾Preheated air temperature 500 C MAXIMUM CAPACITY Max Capacity Parameter Burner model EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 Burner capacity (2% O 2 ) [kw] 100 180 250 450 700 Combustion air flow [Nm 3 /h] 110 198 275 495 770 Gas flow [Nm 3 /h] 10 18 25 45 70 Burner air inlet pressure [mbar] 50 Burner gas inlet pressure [mbar] 70 MINIMUM CAPACITY Parameter Burner model EMB-3 EMB-4 EMB-5 EMB-6 EMB-7 Min. Capacity Burner capacity (2% O 2 ) [kw] 20 36 50 90 140 Combustion air flow [Nm 3 /h] 22 40 55 99 154 Gas flow [Nm 3 /h] 2 36 5 9 14 Burner air inlet pressure [mbar] 2 www.esapyronics.com 6

EMISSIONS Furnace temperature [ C] Preheated air 500 C O 2 = 3% 100% Potential G3507I01 NOx emissions [ppm] NOx emissions [ppm] Preheated air temperature [ C] Chamber T: 1200 C O 2 = 3% 100% Potential G3507I02 www.esapyronics.com 7

BURNER CAPACITY ACCORDING TO PREHEATED AIR TEMPERATURE Capacity (kw) 900 850 800 750 700 650 EMB-7-SIK-NxT 600 550 500 450 EMB-6-SIK-NxT 400 350 300 250 EMB-5-SIK-NxT 200 150 EMB-4-SIK-NxT 100 EMB-3-SIK-NxT 50 200 250 300 350 400 450 500 550 T air ( C) G3507I04 www.esapyronics.com 8

FLOW SCHEME - SINGLE ZONE REGULATION 3 GAS INLET 6 1 2 13 7 5 9 A R 8 11 12 OTHER BURNERS 4 14 10 AIR INLET 15 D3507I02 Pos. Description Included Not included 1 Main gas shut off ball valve X 2 Balanced modulator X 3 Impulse line X 4 Air regulation servo assited butterfly valve X 5 Electric servo motor X 6 Gas shut-off ball valve to the single burners X 7 Main burner safety gas solenoid valve X 8 DP gas measuring calibrated flange X 9 Gas flow limiting device X 10 Manual air regulation butterfly valve X 11 DP air inlet pressure measurement calibrated orifice X 12 Free flame burner X 13 Ignition transformer X 14 Flame control X 15 Premix air regulation group (only LPG model) X www.esapyronics.com 9

FLOW SCHEME - SINGLE BURNER REGULATION 3 GAS INLET 1 2 4 9 5 6 11 IGN 7 8 DET 12 AIR INLET 10 13 D3507I03 Pos. Description Included Not included 1 Main gas shut off ball valve X 2 P gas measurement calibrated flange X 3 Impulse line X 4 Zerogovernor X 5 Safety gas solenoid valve X 6 Gas flow limiting device X 7 Servomotor X 8 Air regulation motorized valve X 9 Ignition transformer X 10 Flame control X 11 High velocity burner X 12 Air inlet orifice X 13 Premix air regulation group (only LPG version) X www.esapyronics.com 10

WARNINGS ¾ EMB-SIK-NxT burner ignition must always be carried out at minimum power, then modulating towards maximum, facilitating start-ups and reducing the excess outlet pressure. Therefore slow opening solenoid valves should be used on the fuel line. ¾ The transition from minimum to maximum power, and vice versa, should be gradual and not instantaneous. ¾ Vertical mounting of burners with flame looking upwards is highly unadvisable. The burners mounted in this position could lack flame or suffer from bad flame detection due to the presence of external objetcs that could deposit on the combustion head and on the electrodes. ¾ For all applications at low temperature (up to750 c) burner ignition and the fuel gas solenoid valve control must be carried out via a certified burner control device. ¾ To avoid possible damage to the burners, make sure that the blower does not send stale air from combustion products, oils, solvents or other. To prevent these phenomena from taking place, preferibly install the blower or suction duct outside of the establishment and far from exhaust pipes. ¾ Check the correct connection of the feeding lines after installation. Before switching the burner on, check that the combustion air and fuel gas pressure values are correct (pag 06). ¾ The burner can only function within the indicated power range. Functioning at lower or higher powers could compromise the burner performance as well as its life span. In which case, the general warrantee conditions will automatically expire and ESA will not be held responsible for any damage to persons or things. ¾ If there is trouble with other devices during the burner start up phase, use the connector with anti disturbance filter for the high-tension (HT) cable connection of the ignition electrode. ¾ Avoid burner ignition close to each other so as not to heat the ignition command system devices (solenoid valves and transformers). Prewash time lapse + first safety time lapse + min. of 5 sec. = time lapse between one ignition and another. (however, do not attempt more than 2 ignitions during a 30sec. time lapse). ¾ Make sure the power supply is TURNED OFF when intervening on the burner and its devices. In case of burner malfunctioning, follow the indications in the 'Maintenance' chapter of the present manual or contact ESA-PYRONICS assistance. ¾ Any modification or repair done by third parties can compromise the application safety and automatically cause the general warrantee conditions to expire. www.esapyronics.com 11

INSTALLATION The EMB-SIK-NxT burners are equipped with a special furnace wall fixing flange. The light obtained for the burner housing must leave open space around the burner. This space has then to be filled with ceramic-fibre. For the installation carefully follow the instructions below: 1 - Place the EMB-SIK-NxT burners far from heat sources and products such as: liquids, solvents or corrosive gases. 2 - Make sure that the housing dimensions and the distance between the centers of the feeding pipes correspond to what is specified in the "Overall dimensions" chapter. 3 - Assemble the burner on the furnace wall (pos. 01), interposing a ceramic fibre gasket between the attachment flange and the furnace wall (pos. 02). Once the burner has been fixed to the furnace, from inside the combustion chamber, use ceramic fibre mat to seal any cracks left etween the wall and silicon carbide flame holder tube according to the indications in the Overall dimensions chapter. 4 - Connect the combustion air and fuel gas inlet piping, interposing, if possible, dilation joints of correct sizes. 5 - Connect electricity to the ignition electrode and to the uv-scan detector making sure not to pass the conductors near heat sources. 6 - Check that the burner body and all its metallic elements are earthed with appropriate conductors. 7 - The connecting cable from the ignition transformer to the electrode must be specific for high tension and not screened. It must not be more than 1 metre long; otherwise the ignition transformer must be positioned near the burner. The high tension cable must be placed far from the power cables and not in metallic ducts. Ideally it should be left in open air. 8 - For further information please consult the technical data sheet concerning the ignition transformers. 01 02 D3506I04 www.esapyronics.com 12

FURNACE WALL MOUNTING CHART WALL THICKNESS X > 290mm 45 WALL THICKNESS X = 290mm 290 X ø N ø N 45 X WALL THICKNESS X < 290mm Furnace wall fixing spacer ø N 45 X 290 W D3507I05 www.esapyronics.com 13

START UP - SETTING The procedures indicated in the following chapter must be carried out by expert technicians. The non-observance of the instructions given can provoke dangerous conditions. 1 - Check that the combustion air pressure exiting the blower and the combustive fuel feeding pressure are both within the allowed range. 2 - Adjust the working pressure and the safety device pressure of the combustion plant, whether there is one per burner or one for the whole plant i.e. gas pressure reduction gear, block valve, relief valve, pressure switches etc. Simulate the intervention of all the safety devices including the intervention of the safety over temperature, checking that the fuel safety block devices act properly. 3 - Referring to the maximum capacity values indicated in the Burner performance chapter, place the motorized position the air regulation motorized valve. 4 - Referring to the maximum capacity values indicated in the Burner performance chapter, place the motorized position the air regulation motorized valve. 5 - Activate the burner control device and attempt the ignition until the burner switches on. While attempting to ignite the burner, act on the gas adjustment valve and, starting from the totally closed position, open it gradually until the burner ignites. 6 - With the burner running, place the air regulation valve as described in point 3, via the gas regulation valve the maximum gas flow rate check the differential pressure that is created on the calibrated gas flange. 7 - Double check that, at minimum and maximum power, the burner inlet pressure corresponds to the values in the in the 'PARAMETER CAPACITY" chapter. These values may be different depending on whether the burner is on or off.. 8 - If necessary, with all burners turned onto the same power, analyse the combustion products in the chamber (where possible).. 9 - Repeatedly attempt ignition at minimum burner power, with maximum amplitude, to check the ignition reliability and flame stability during the adjustment. PREMIX AIR FLOW SETTING WHERE SCHEDULED (LPG BURNERS).The premix line is supplied with the LPG burners. The setting must be carried out with burner off and in minimum flow conditions. The premix line must be fed by an inlet necessarily placed upstream the air flow regulation valve, whether it is in zone or interlocked by the main burner. 1 - Place the burner in the minimum combustion air flow conditions. 2 - Open the premix air tap upstream the general regulation valve (the flow must be steady) 4 - Check however that at minimum capacity, the burner does not create black smoke on the combustion head and on the electrodes. Should this occur, increase the premix air setting. EMB-3-SIK-NxT: Gas pressure body = 2 mbar EMB-4-SIK-NxT: Gas prerssure body = 2 mbar EMB-5-SIK-NxT: p=6.2 mbar EMB-6-SIK-NxT: p=6.5 mbar EMB-7-SIK-NxT: p=2.5 mbar 3 - Regulate the air flow using the pin valve and consulting the appropriate setting chart (page 10). The aim is to obtain quite a tense bluish flame www.esapyronics.com 14

GENERAL MAINTENANCE PLAN Operation Type Advised time Notes High tension electrode connection O annual Electrode ignition / detection O annual Combustion head O annual SIC flame tube O annual check integrity of outer plastic and oxidi -zation of internal electrode terminal. replace if the kantal terminal is worn or if the ceramic is damaged. during furnace stop, check that the two elements do not show signs of oxidization caused by high temperature or deposits on the surface. during furnace stop check that there are no cracks in the ceramic material. If necessary, replace. Gasket replacement of the gas side E annual See note (*) and note (**) Burner settings O annual Premix air setting (where scheduled) O annual Repeat all the steps in the START UP AND SETTINGS chapter. Repeat all the steps in the PREMIX AIR SETTING chapter. NOTES: Key: O = ordinary / E = extraordinary (*) it is suggested that the gaskets on the gas side are replaced after every disassembly of the gas feeding line. (**) use high temperature gaskets. www.esapyronics.com 15

EXTRAORDINARY MAINTENANCE For correct dismantling and better maintenance of the EMB-SIK-NxT burner, meticulously follow the instructions below with the plant turned off. FLAME DETECTION AND IGNITION ELECTRODE REPLACEMENT 1 - Check that the burner control device is disconnected 2 - Disconnect electrical supply to the electrodes (pos. 01). 3 - Unscrew the connector (pos. 02) at the base of the gas collector, removing the electrode (pos. 03). 4 - Replace the faulty electrode (pos. 03) paying attention to the correct repositioning of the new electrode. 5 - Reconnect the electrical supply (pos. 01). 6 - Check the electrode's correct flame ignition/detection. 01 02 03 D3507I06 BURNER LOCKOUT In lockout conditions of the burner refer to the burner control device and to the relative handbook to identify the cause. Below we have indicated the main cases: ¾Illegal flame detection: the shutdown is due to an illegal flame detection during the phases prior to ignition or after the turning off. The causes are within the detection system (broken or faulty sensor or presence of humidity), or in the gas draw from the solenoid safety valve, which allows the burner to remain turned on. ¾Failed ignition: shutdown is caused due to the fact that no flame has been created during the starting process. The causes can be found in the start-up system (spark absence, faulty electrodes or incorrect position), in the bad setting of the fuel and combustion flow or in the detection system (faulty sensor or interrupted cables). More precisely, in the first two cases the flame is not ignited, while in the last case the flame is created but the burner control device is unable to detect it. ¾Flame signal loss: shutdown due to the loss of flame signal during the normal functioning of the burner. The causes can be found in the combustion air flow adjustment (rapid flow variations, adjustment out of allowed range). They can also be found in the detection system (faulty, dirty or badly positioned sensors). www.esapyronics.com 16

OVERALL DIMENSIONS - EMB-SIK-NxT E MIN. 100 (b) by customer P MIN. 100 (b) by customer GAS INLET ø B ø N ø M W G X C F AIR INLET ø A Ceramic fiber insulation 45 No. 4 holes ø K eq.sp. on ø L D.B.C. D D3507I07 Model ø A ø B C D E F EMB-3-SIK-NxT Rp. 2.1/2 Rp. 3/4 343 118 107 222 110 14 200 240 138 290 46 60 17.6 EMB-4-SIK-NxT DN80 Rp. 1 356 126 107 273 149 14 250 280 172 290 46 75 25.9 EMB-5-SIK-NxT DN100 Rp. 1 387 126 132 279 149 14 295 320 172 290 46 75 27.7 EMB-6-SIK-NxT DN150 Rp. 1.1/2 468 156 137 355 183 14 295 320 208 290 67 75 40.4 EMB-7-SIK-NxT DN200 Rp. 2 562 221 185 443 218 14 360 400 250 290 67 80 72.5 G ø K ø L ø M ø N X P W Mass [Kg] www.esapyronics.com 17

OVERALL DIMENSIONS - EMB-SIK-NxT-BH "E" GAS INLET Ø"B" "X" "C" "F" "G" AIR INLET Ø"A" FIBER INSULATION BY ESA DO NOT REMOVE! MIN. 100 (b) Min. 100 (b) by customer"p" by customer o "Q" FURNACE CUT OUT o"n" o "M" Nr. 4 holes Ø"K" eq.sp. on Ø"L" D.B.C. "D" D3507I08 Model ø A ø B C D E F EMB-3-SIK-NxT Rp. 2.1/2 Rp. 3/4 343 118 107 222 110 14 278 330 241 290 46 229 55 EMB-4-SIK-NxT DN80 Rp. 1 356 126 107 273 149 14 278 330 241 290 46 229 64 EMB-5-SIK-NxT DN100 Rp. 1 387 126 132 279 149 14 278 330 241 290 46 229 52 EMB-6-SIK-NxT DN150 Rp. 1.1/2 468 156 137 355 183 14 349 410 311 290 67 298 92 EMB-7-SIK-NxT DN200 Rp. 2 562 221 185 443 218 14 464 508 432 290 67 419 140 G ø K ø L M N X P Q Mass [Kg] www.esapyronics.com 18

ORDERING CODE - COMPLETE BURNER - SIK - - - - EMB NxT - 01 02 03 04 05 Model 01 03 Fuel EMB-3-SIK EMB-4-SIK EMB-5-SIK EMB-6-SIK EMB-7-SIK 3 4 5 6 7 Methane LPG Poor gas( 1 ) CH4 GPL GP 04 Ignition and detection Double electrode E* Gas Adjuster With Gas Adjuster Without Gas Adjuster GA* F 02 05 Flange type According to ESA dwg According to client s dwg E* C (*) The codes marked with an asterisk (*) indentify the standards. Notes: 1 Particular performance according to gas characteristics www.esapyronics.com 19