Materials. Contact Ratings. Conduit Entrances

Similar documents
Potter Electric Signal Company, LLC St. Louis, MO Tech Support: / Customer Service:

PCVS Series Control Valve Supervisory Switch

OSYSU Series Outside Screw and Yoke Valve Supervisory Switch

I-BFV.KIT Butterfly Valve Gear Operator Replacement

the Interactive Catalog

Model RM-1 Riser Manifold Commercial and Residential General Description

Series 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.

Quarter Master Chief Series 92 Actuator

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

2000 Series Geared Rotary Limit Switches

the Interactive Catalog

Quarter Master Series 94 Actuator

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Installation and Service Instructions for EX Series Explosion-proof Switches

Electric Actuators Maximum in-lbs

Series 10 Actuator. Installation, Operation and Maintenance Manual

Electric Actuators Maximum in-lbs

Worldwide Contacts. Technical Data

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Shock/Vibration Control Switches

MICRO SWITCH Weather-Sealed, Explosion-Proof Switches. CX Series. Datasheet

ECON Limit Switch Box Fig

Model 5000 Level Controller

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

General Description. Product Specification. Document Digital Temperature Interlock

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Integrated Control modules

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

MODEL 40 TYPE W TANK OVERFILL ALARM

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe

PISTON STYLE GAUGE. Mid-West Instrument

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

M9216 Series Electric Spring Return Actuators

ANDCO Eagle Actuator Instruction Manual

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Integrated Control modules

IEC Limit Switches Selection Guide

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

VA-7450 Series. Electric Valve Actuators

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

2006 Series Geared Rotary Limit Switches

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

Valve Position Monitors

Installation and Operating Manual

Cam-Lok Single Pole Connectors

MAXIGARD A2000 SPEED SWITCH. Introduction

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

the Interactive Catalog

RF Point Level Control with Sensor Monitor

INERGEN. 150-BAR SYSTEMS Design, Installation, Recharge, and Maintenance Manual

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

Type 2000 Transducer Product Instructions

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide

DC CCTV Power Supplies Installation Guide

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

SP/SF Series Flow Switches

Features. North & South America: Europe / Africa / Middle East: Asia Pacific:

AL600ULX Series. Power Supply/Charger Installation Guide

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

IEC Limit Switches Selection Guide

VA-4233-AGx Series Electric Valve Actuators

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Seismic Sensor Accessories SA, SV & ST 6000 Series

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Hinged Safety Door Switch

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Scraper Passage Indicator Bulletin No: Version: Supersedes: ( ) ECN: E Features

INSTRUCTION MANUAL VIBRASWITCH MALFUNCTION DETECTOR MODEL 366

Mid-West. Instrument ELECTRICAL DIVISION 1 LOCATIONS:

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

Bourdon Tube Pressure Switches

Quarter Master Series 94 Actuator

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

SMP3CTX Series Power Supply/Charger

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Series Electric Actuators

37T Series Moisture Resistant Temperature Controls

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

Transcription:

Features NEMA 1, 3, 4, 4X, 6, 6P, 9 & 13 IP66 and 67 Water tight, dust tight and corrosion resistant for outdoor use For use in hazardous locations: Class I, Div. 1 & 2, Groups C, D Class II, Div. 1 & 2, Groups E, F, G Explosion proof switch enclosure: UL Listed, file #E14274 CSA Certified, File #LR57324 ATEX/IEC EX Approved, File #KEMA 04ATEX2312X Adjustable length trip rod Ample wiring space RoHS Compliant Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. Important: This document contains important information on the installation and operation of valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description The PIVSU-EX-O is designed to supervise the position of a Post Indicator or Butterfly valve in hazardous outdoor locations. The device mounts in a 1/2 NPT threaded nipple to the valve body. When properly mounted, the indicator of the Post Indicator valve or the operating mechanism of the Butterfly Valve will be pushing against the return spring of the PIVSU-EX-O so that as the valve is operated, the spring in the PIVSU-EX-O pulls the trip rod over and activates the switch. To aid with installation the trip rod length is adjustable. This device features a UL listed explosion proof switch enclosure. Testing The operation of the PIVSU-EX-O and its associated protective monitoring system shall be tested upon completion of the installation and inspected, tested and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Jurisdiction, (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve operating mechanism towards the closed position. The PIVSU-EX-O shall operate within the first two revolutions of the operating mechanism. Fully close the valve and ensure the PIVSU-EX-O does not restore. Fully open the valve and ensure that the PIVSU-EX-O restores to normal. Technical Specifications Dimensions See Fig. 6 Weight Materials Contact Ratings Environmental Limitations Conduit Entrances Mounting 3.3 lbs. Switch Enclosure - Aluminum Plate/Nipple/Hardware - Stainless Steel One set of SPDT 15 Amps at 125VAC.5 Amps at 125VDC Terminals accept up to 14AWG wire -13 F to 185 F (-25 C to 85 C) Class I, Div. 1 & 2, Groups C, D Class II, Div. 1 & 2, Groups E, F, G NEMA 1, 3, 4, 4X, 6, 6P, 9, 13, IP66 and 67 Two 3/4-14 NPT threaded entrance 1/2 NPT Service Use NFPA 13, 13D, 13R, 72 Specifications subject to change without notice MFG. #5401547 - REV B 1/16 PAGE 1 OF 7

Theory Of Operation The PIVSU-EX-O is a spring loaded switch. It is in normal position when the trip rod is pulling against the spring force. Normal is when the switch is installed on the valve and the valve is fully open. As the valve closes, the valve actuator moves away from the trip rod of the PIVSU-EX-O and the spring on the PIVSU-EX-O pulls the trip rod over and trips the switch. Alternate Window Installation and Moving Hood Installation Target Moves Up as Valve is Shut Fig 1 Fig 2 Hood Moves Down as Valve is Shut Subject to the approval of the authority having jurisdiction the alternate method of installation shown in Fig. 1 may be used. In this method, one of the glass windows of the housing is replaced with a 1/4 thick metal plate that is cut to fit in place of the glass and drilled and tapped to recieve 1/2 NPT pipe nipple. In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PIVSU-EX-O trip rod. If the target is stationary and a hood arrangement is used, such as is shown in Fig. 2, the hood must be drilled with a 23/32 drill and tapped with a 1/2 NPT. The center line of this hole should be 1/8 below the portion of target assembly that strikes the PIVSU-EX-O trip rod. The 11 3/8 dimension shown is for a Clow Valve. Flexible conduit must be used for this type of installation. (More on pg. 3). Steel Tripping Block Replaces Open Marker Metal Plate Replaces Glass Locknut Locknut 11 3/8 (28,9 cm) Shut Marker Target Assembly MFG. # 5401547 - REV B 1/16 PAGE 2 OF 7

Typical Installation On Post Indicator valve Housing Typical Valve Installation Typical Valve Installation Fig 3 Fig 4 Target moves up as valve is shut. Target moves down as valve is shut. 1. Position the valve to fully open ( OPEN should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. If the valve housing is predrilled with a 1/2 NPT for installation of a monitoring switch, remove the 1/2 plug and fully open the valve. Make sure that OPEN appears in the window of the housing. GO TO STEP NO. 6. 2. If the valve is not pre-drilled for 1/2 NPT, remove the head and target assembly (consultation with valve manufacturer is recommended). 3. If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PIVSU-EX-O (see Fig. 3). This is usually a plate or bar on the target assembly, on a side adjacent to the OPEN/ SHUT plates. Subtract 1/8 from the measurement. If the target moved down as the valve was closed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PIVSU-EX-O (see Fig. 4). Add 1/8 (3,2mm) to this measurement. 4. Mark the housing at the proper location. Using a 23/32 (18,2mm) drill bit, drill and then tap a 1/2 NPT in the housing on the side that coincides with the portion of the target assembly that will engage the trip rod of the PIVSU- EX-O. 5. Replace the head and target assembly. 6. Insert a scale or probe into the valve housing to measure the distance from the opening on the valve to the target assembly. Subtract ½ from this measurement. 7. Adjust the trip lever of the PIVSU-EX-O so the trip lever protrudes past the end of the nipple by the distance measured in step 6. Include the ½ subtraction. In some instances it may be necessary to remove the trip lever and using a pliers break off the 1 long notched section. See fig 11. 8. Partially close the valve, 4 6 revolutions 9. Screw the PIVSU-EX-O into the valve body until it is oriented correctly, tighten the jam nut. The spring loaded trip lever of the PIVSU-EX-O follows the valve target as it moves when the valve is operated. Proper orientation is with the rectangular switch body parallel with the valve housing and the target of the valve pushing against the spring force of the PIVSU-EX-O trip lever when the valve is fully open. Adjust the trip lever length if necessary. 10. Carefully open the valve to the fully open position. As the target moves to the open position it should engage the trip rod and actuate the switch. There should be a minimum overtravel of 1/2 revolution of the handle/hand wheel after the switch actuates (a continuity meter connected to the switch contacts is one method that could be used to determine this). 11. Slowly close the valve. The switch must operate during the first two revolutions of the handle/hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. NOTE: Small adjustments of the target position may be necessary (consultation with valve manufacturer is recommended). 12. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PIVSU-EX-O installation and the signaling system. Check that all electrical and mechanical connections are secure. 13. When the installation and testing are complete, return valve to its proper position. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com MFG. #5401547 - REV B 1/16 PAGE 3 OF 7

Typical Installation on a Butterfly Valve Fig 5 Typical Indicating Butterfly Valve Fig 6 Dresser Indicating Butterfly Valve 1/32 (0,8 mm) Valve Partially Closed Valve Open 1/2 (13mm) 1. Insert a scale or probe into the valve housing to measure the distance from the opening on the valve to the target assembly. Subtract ½ from this measurement. 2. Adjust the trip lever of the PIVSU-EX-O so the trip lever protrudes past the end of the nipple by the distance measured in step 1. Include the ½ subtraction. In some instances it may be necessary to remove the trip lever and using a pliers break off the 1 long notched section. See fig 11. 3. Partially close the valve, 4 6 revolutions. 4. Screw the PIVSU-EX-O into the valve body until it is oriented correctly, tighten the jam nut. The spring loaded trip lever of the PIVSU-EX-O follows the cam in the gearbox as it moves when the valve is operated. Proper orientation is with the rectangular switch body parallel with the valve gearbox and the cam of the valve pushing against the spring force of the PIVSU-EX-O trip lever when the valve is fully open. Adjust the trip lever length if necessary. 5. Carefully open the valve to the fully open position. As the cam moves to the open position it should engage the trip rod and actuate the switch. There should be a minimum over travel of 1/2 revolution of the handle/hand wheel after the switch actuates (a continuity meter connected to the switch contacts is one method that could be used to determine this). 6. Slowly close the valve. The switch must operate during the first two revolutions of the handle/hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. 7. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PIVSU- EX-O installation and the signaling system. Check that all electrical and mechanical connections are secure. 8. When the installation and testing are complete, return valve to its proper position. If the PIVSU-EX-O is to be mounted on a valve that already contains an internal supervisory switch or on a valve that is to be supervised in the closed position, an external bracket similar to that shown in fig 4 will be necessary. Due to the possibility of changes in valve design by the valve manufacturers, brackets may not fit exactly and may need field modification. Contact Potter tech support for bracket drawings. MFG. # 5401547 - REV B 1/16 PAGE 4 OF 7

Typical Installation on a Butterfly Valve with factory installed supervisory switch If the PIVSU-EX-O is to be mounted on a valve that already contains an internal supervisory switch or on a valve that is to be supervised in a closed position, an external bracket similar to that shown in figures 7 and 8 will be necessary. Due to the possibility of changes in valve design by the valve manufacturers, brackets may not fit exactly and may need field modification. Contact Potter Tech Support for bracket drawings. Fig 7 Fig 8 LOCKNUTS BOTH SIDES BRACKETS AND LOCKNUTS SUPPLIED WITH PBK MOUNTING KIT DWG. #694-4 Model PBK-L Stock No. 0090132 (MDT-4S Actuator) 18"-24" valves Model PBK-M Stock No. 0090146 (MDT-3S Actuator) 14"-16" valves Model PBK-S Stock No. 0090133 (MDT-2S Actuator) 3"-12" valves Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model IBV Valve. Victaulic/Kennedy Kit: Stock No. 0090143 Kits contain: Bracket, nuts, and instructions NOTE: This application is subject to the approval of the authority having jurisdiction. TBK Stock No. 0090150 Tyco BFN-N Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com MFG. #5401547 - REV B 1/16 PAGE 5 OF 7

Fig 9 5.00in 127mm 4.00in 101.60mm Dimensions 5.44in 138.28mm 5.26in 133.71mm 2.95in 74.80mm 4.09in 103.89mm 2.92in 74.24mm 2.00in 50.80mm 5.33in 135.38mm ROD RETRACTED AND 4.09in 103.89mm MFG. # 5401547 - REV B 1/16 PAGE 6 OF 7

Breaking Excessive Rod Length Fig 10 Switch Terminal Connections Fig 11 Ordering Information Model Description Stock No. PIVSU-EX-O Outdoor Explosion Proof Supervisory Switch 1010123 PBK-S Pratt Butterfly Valve Kit (3 to 12 ) 0090133 PBK-M Pratt Butterfly Valve Kit (14 to 16 ) 0090146 PBK-L Pratt Butterfly Valve Kit (18 to 24 ) 0090132 PVK Pratt Valve Kit 1000060 KBK Victaulic/Kennedy Butterfly Valve Kit 0090143 TBK Tyco Butterfly Valve Kit 0090150 Outgoing Incoming (Optional brackets for mounting to valves with factory installed supervisory switches, or to valves that are to be supervised in the closed position.) NOTE: Due to the possibility of changes in valve design by the manufacturers, brackets may not fit exactly and may require field modification. Contact Potter Tech Support for bracket drawings. An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Typical Electrical Connections Fig 12 From Control Panel COM NC End-of-Line Resistor NO COM NC NO Engineering Specifications: Explosion Proof supervisory switch for Post Indicator and Butterfly Valves Explosion proof valve supervisory switches shall be furnished and installed on all PIV and butterfly type valves that can be used to shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The switch enclosure shall be UL Listed and CSA Certified and NEMA 1, 3, 4, 4X, 6, 6P, and 13 rated for hazardous locations classified as Class I, Division 1 and 2, groups C and D and Class II, Division 1 and 2, groups E, F and G and capable of being mounted in any position indoors or outdoors. The enclosure shall contain two ¾ - 14 NPT threaded opening for conduit connection. The device shall incorporate a stainless steel ½ male NPT nipple for attachment to the valve body. The device shall contain an adjustable length trip rod, the trip rod shall be held captive by a set screw accessible without removal of the cover. The switch contacts shall be rated at 15.0A, 125/250VAC and 0.5A, 125VDC. Explosion proof PIV and Butterfly Valve supervisory switch shall be model PIVSU-EX-O manufactured by Potter Electric Signal Company LLC. Supervisory Switches have a normal pressure service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. From Power Source Indicating Device Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 www.pottersignal.com MFG. #5401547 - REV B 1/16 PAGE 7 OF 7