Energy-efficient, high-intensity white LED wash light
Energy-efficient, high-intensity white LED wash light ew Blast Powercore is an LED lighting fixture providing a high-intensity wash of white light while consuming less energy than comparable non-led light fixtures. Rated for outdoor use, offers the efficiency and cost-effectiveness of Powercore technology in a rugged die-cast aluminum housing. ew Blast Powercore is ideal for applications as diverse as highlighting architectural features, general site illumination, and lighting signage and retail spaces. Integrates patented Powercore technology Powercore technology rapidly, efficiently, and accurately controls power output to ew Blast Powercore fixtures directly from line voltage, supporting long fixture runs and eliminating the need for external power supplies. Contractorfriendly installation using standard mounting and wiring dramatically simplifies installation and helps lower total system cost. Supports new applications for white light Long useful source life (up to 70,000 hours at 70% lumen maintenance) can significantly reduce or eliminate maintenance problems, allowing the use of white lighting in spaces where lamp maintenance may be impossible. For example, ew Blast Powercore can effectively illuminate building features from positions accessible only by crane. High-intensity, energy-efficient white light With an output of up to 2390 lumens, ew Blast Powercore offers high-intensity illumination at a significantly lower power draw than comparable non-led fixtures. Versatile lighting options is available in two color temperatures, a warm 2700 K and a cool 4000 K, and four solid colors (Red, Green, Blue, and Amber). A 21 frosted glass lens for a soft-edge beam and a 10 clear lens for extended light projection support a wide range of white lighting applications. Rugged die-cast aluminum housing is available in white or black. Flexible light positioning Fixtures can be mounted to a junction box on a wall, ceiling, or floor for maximum flexibility. Locking base swivel offers friction-free rotation of up to 350, and 110 fixture tilting provides quick fixture positioning without special tools. Support for multiple voltages ew Blast Powercore accepts power input of 100, 120, 240, and 277 VAC, allowing installation and operation from line voltage in a variety of locations. Dimming capability Patented DIMand technology offers smooth dimming capability with many ELV-type dimmers. Outdoor Rated Fully sealed for maximum fixture life, fixtures meet or exceed specifications for use in wet locations. 2 Product Guide
The Arrival of White LED Lighting for General Illumination Retrofitting Boston s Marriott Custom House Tower In 2008, Boston s first official skyscraper, the Marriott Custom House Tower, shown here and on the cover, underwent a long-awaited lighting redesign that restores its prominence on the Boston skyline in a smart and sustainable way. Formerly lit by incandescent-based fixtures that had fallen into disrepair, the tower was restored using energy-efficient, low-maintenance white LED fixtures from Philips. A combination of 125 and ew Graze Powercore fixtures now fully illuminate the tower from the 17th floor to the peak. Photography: John Brandon Miller Photography Cost-Effective, Energy-Efficient, and Easy to Maintain Not only do the LED fixtures in the installation consume just one third the energy of the previous incandescent sources, the LED sources that they use have a projected useful life of more than 20 years at six hours of use per day, requiring far less maintenance. By incorporating proprietary Powercore technology to directly accept line voltage, the fixtures eliminate the special cabling and external low-voltage power supplies that LED light fixtures have historically required. Because they use standard wiring and power sources, the lighting designers were able to easily replace the former incandescent light fixtures one-for-one in their existing locations and mountings. Lighting Design: Lam Partners Photography: Brad Koerner New Possibilities for White LED Lighting The efficiency and long source life of ew Blast Powercore and other Philips white LED fixtures open up new possibilities for sustainable architectural lighting. As the Custom House Tower installation shows, in dramatic and elegant fashion, white LED lighting has arrived as a viable, energy-efficient alternative for general illumination. Product Guide 3
Photometrics Photometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.colorkinetics.com/support/ies. 2700 K, 21º Frosted Lens Lumens 1786 Efficacy 38.2 lm / W Polar Candela Distribution Cd: 0 1,300 90º 80º 2,600 70º 3,900 60º 5,200 6,500 50º 7,800 VA: 0º 10º 20º 30º 40º - 0º H - 90º H Illuminance at Distance 4.0 ft 8.0 ft 12.0 ft 16.0 ft 20.0 ft 24.0 ft Center Beam fc 487 fc 122 fc 54 fc 30 fc 19 fc 14 fc 88.3 ft (26.9 m) 1 fc maximum distance Beam Width 1.4 ft 1.4 ft 2.9 ft 2.9 ft 4.3 ft 4.3 ft 5.7 ft 5.8 ft 7.2 ft 7.2 ft 8.6 ft 8.7 ft Vert. Spread: 20.3º Horiz. Spread: 20.5º Zonal Zonal Lumen Summary Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio 2700 K, 10 Clear Lens Lumens 1990 Efficacy 42.3 lm / W Polar Candela Distribution Cd: 0 11,333 90º 80º 22,667 70º 34,000 60º 45,333 56,667 50º 68,000 VA: 0º 10º 20º 30º 40º - 0º H - 90º H Candela Table Illuminance at Distance 4 ft 8 ft 12 ft 16 ft 20 ft 24 ft Center Beam fc 4200 fc 1050 fc 467 fc 262 fc 168 fc 117 fc 259 ft (78.9 m) 1 fc maximum distance Beam Width 0.6 ft 0.6 ft 1.1 ft 1.1 ft 1.7 ft 1.7 ft 2.2 ft 2.3 ft 2.8 ft 2.8 ft 3.4 ft 3.4 ft Vert. Spread: 8.0º Horiz. Spread: 8.1º Zonal Zonal Lumen Summary Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 4 Product Guide
4000 K, 21º Frosted Lens Lumens 2141 Efficacy 45.9 lm / W Polar Candela Distribution Cd: 0 1,583 90º 80º 3,167 70º 4,750 60º 6,333 7,917 50º 9,500 VA: 0º 10º 20º 30º 40º - 0º H - 90º H Candela Table Illuminance at Distance 4.0 ft 8.0 ft 12.0 ft 16.0 ft 20.0 ft 24.0 ft Center Beam fc 587 fc 147 fc 65 fc 37 fc 24 fc 16 fc 97 ft (30 m) 1 fc maximum distance Beam Width 1.4 ft 1.4 ft 2.9 ft 2.9 ft 4.3 ft 4.3 ft 5.7 ft 5.8 ft 7.2 ft 7.2 ft 8.6 ft 8.6 ft Vert. Spread: 20.3º Horiz. Spread: 20.4º Zonal Zonal Lumen Summary Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio 4000 K, 10 Clear Lens Lumens 2390 Efficacy 50.9 lm / W Polar Candela Distribution Cd: 0 13,333 90º 80º 26,667 70º 40,000 60º 53,333 66,667 50º 80,000 VA: 0º 10º 20º 30º 40º - 0º H - 90º H Illuminance at Distance 4.0 ft 8.0 ft 12.0 ft 16.0 ft 20.0 ft 24.0 ft Center Beam fc 4952 fc 1238 fc 550 fc 309 fc 198 fc 138 fc 281 ft (85.6 m) 1 fc maximum distance Beam Width 0.6 ft 0.6 ft 1.1 ft 1.1 ft 1.7 ft 1.7 ft 2.3 ft 2.3 ft 2.8 ft 2.9 ft 3.4 ft 3.4 ft Vert. Spread: 8.1º Horiz. Spread: 8.2º Zonal Zonal Lumen Summary Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: Ceiling reflectance percentage, RW %: Wall reflectance percentage, RCR: Room cavity ratio For lux multiply fc by 10.7 Product Guide 5
Specifications Due to continuous improvements and innovations, specifications may change without notice. Item Specification 2700 K* 4000 K* Output Electrical Control Physical Certification and Safety Beam Angle 10 / 21 Lumens Efficacy (lm / W) 1786 (21 beam angle) 1990 (10 beam angle) 38.2 (21 beam angle) 42.3 (10 beam angle) CRI 82 80 Mixing Distance Lumen Maintenance Input Voltage Power Consumption Dimming Dimensions (Height x Width x Depth) Weight Housing Lens Fixture Connections Temperature Ranges Humidity Certification Environment 6 in (152 mm) to uniform light 2141 (21 beam angle) 2390 (10 beam angle) 45.9 (21 beam angle) 50.9 (10 beam angle) 70,000 hours L 70 @ 25 C 37,000 hours L 70 @ 50 C 90,000 hours L 50 @ 25 C 68,000 hours L 50 @ 50 C 100 / 120 / 240 / 277 VAC, auto-switching, 50 / 60 Hz 50 W maximum at full output, steady state Compatible with many commercially available ELV, trailing edge, or reverse-phase control dimmers. 7.1 x 12.5 x 4.9 in (180 x 318 x 124 mm) 6.4 lb (2.9 kg) Die-cast aluminium, white or black powder-coated finish. Clear tempered glass (10º beam angle) Frosted tempered glass (21º beam angle) 6 ft (1.8 m) unified power / data cable -40 122 F (-40 50 C) Operating -4 122 F (-20 50 C) Startup -40 176 F (-40 80 C) Storage 0 95%, non-condensing UL / cul, FCC Class A, CE Dry / Damp / Wet Location, IP66 110º 21º Beam Angle 12.5 in 318 mm 4.75 in 121 mm 110º Rotation 1.35 in 34 mm 0.65 in 17 mm 110º 10º Beam Angle 6.5 in 165 mm * Correlated color temperature (CCT) complies with ANSI C78.377-2008 for the chromaticicty of solid state lighting products. Lumen measurement complies with IES LM-79-08 testing procedures. L70 = 70% maintenance of lumen output (when light output drops below 70% of initial output). L50 = 50% maintenance of lumen output (when light output drops below 50% of initial output). Ambient temperatures specified. Based on measurements that comply with IES LM-80-08 testing procedures. Refer to www.colorkinetics.com/support/appnotes/lm-80-08.pdf for more information. Refer to www.colorkinetics.com/support/appnotes/ for specific details. 7.1 in 180 mm 4.9 in 124 mm 6.5 in 165 mm 3.9 in 99 mm 7.25 in 184 mm 6 Product Guide
Fixtures Included in the box fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions Item Housing Color Lens Item Number Philips 12NC Frosted 21 523-000049-00 910503700773 White Clear 10 523-000049-02 910503700775 2700 K UL / cul Frosted 21 523-000049-01 910503700774 Clear 10 523-000049-03 910503700776 Frosted 21 523-000049-04 910503700777 White Clear 10 523-000049-06 910503700779 4000 K UL / cul Frosted 21 523-000049-05 910503700778 Clear 10 523-000049-07 910503700780 Frosted 21 223-000049-12 910503701180 White Clear 10 223-000049-14 910503701182 Red UL / cul Frosted 21 223-000049-13 910503701181 Clear 10 223-000049-15 910503701183 Frosted 21 223-000049-04 910503701172 White Clear 10 223-000049-06 910503701174 Green UL / cul Frosted 21 223-000049-05 910503701173 Clear 10 223-000049-07 910503701175 Frosted 21 223-000049-00 910503701168 White Clear 10 223-000049-02 910503701170 Blue UL / cul Frosted 21 223-000049-01 910503701169 Clear 10 223-000049-03 910503701171 Frosted 21 223-000049-08 910503701176 White Clear 10 223-000049-10 910503701178 Amber UL / cul Frosted 21 223-000049-09 910503701177 Clear 10 223-000049-11 910503701179 2700 K CE 4000 K CE Red CE Green CE Blue CE Amber CE White White White White White White Frosted 21 523-000049-08 910503700781 Clear 10 523-000049-10 910503700783 Frosted 21 523-000049-09 910503700782 Clear 10 523-000049-11 910503700784 Frosted 21 523-000049-12 910503700785 Clear 10 523-000049-14 910503700787 Frosted 21 523-000049-13 910503700786 Clear 10 523-000049-15 910503700788 Frosted 21 223-000049-28 910503701196 Clear 10 223-000049-30 910503701198 Frosted 21 223-000049-29 910503701197 Clear 10 223-000049-31 910503701199 Frosted 21 223-000049-20 910503701188 Clear 10 223-000049-22 910503701190 Frosted 21 223-000049-21 910503701189 Clear 10 223-000049-23 910503701191 Frosted 21 223-000049-16 910503701184 Clear 10 223-000049-18 910503701186 Frosted 21 223-000049-17 910503701185 Clear 10 223-000049-19 910503701187 Frosted 21 223-000049-24 910503701192 Clear 10 223-000049-26 910503701194 Frosted 21 223-000049-25 910503701193 Clear 10 223-000049-27 910503701195 Use Item Number when ordering in North America. Product Guide 7
Accessories Designed specifically for the family of Blast fixtures, accessories provide additional options for controlling and dispersing light. Accessory holders snap to the front of the fixture and are required for mounting accessories. Accessory holders prevent accessories from falling out if the fixture is tipped or hung upside down. Item Housing Color Item Number Philips 12NC Accessory Holders White 120-000070-00 120-000070-01 Half Top Hats White 120-000009-03 120-000009-04 Top Hats White 120-000005-03 120-000005-04 Egg Crate Louvers White 120-000015-03 120-000015-04 Barndoors White 120-000019-03 120-000019-04 Horizontal Spread Lens 36 / 50 120-000025-00 Vertical Spread Lens 40 120-000025-01 8 Product Guide
Installation is an LED floodlight providing a high-intensity wash of white light while consuming less energy than comparable non-led fixtures. Powercore, which delivers line voltage directly to the fixture, eases installation by eliminating the need for external power supplies or special wiring. E Refer to the Installation Instructions for specific warning and caution statements. Owner/User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance. Installing in Damp or Wet Locations When installing in damp or wet locations, it is good practice to seal all fixtures and junction boxes with electronics-grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in any wiring compartments, cables, or other electrical parts. You must use suitable outdoor-rated junction boxes when installing in damp or wet locations. Additionally, you must use gaskets, clamps, and other parts required for installation to comply with all applicable local and national codes Included in the box fixture (2) 8-32 screws for indoor installation (4) 10-24 stainless steel screws for outdoor installation 1/8 in hex key wrench for fixture positioning and locking Junction box gasket Installation Instructions Assemble Additional Parts and Tools Ensure that all additional parts and tools are available, including: The provided 8-32 screws for indoor installations, or the 10-24 stainless steel screws for outdoor installations The provided 1/8 in hex key wrench One 4 in (102 mm) round US electrical junction box per fixture, rated for your application, with 3.5 in (89 mm) center-to-center screw holes for attaching the fixture s base. (Refer to the manufacturer s literature for additional items required for mounting or sealing.) The provided junction box gasket A sufficient length of 3-conductor copper wire Conduit as required Electronics-grade room temperature vulcanizing (RTV) silicone sealant as required Install the Fixtures fixtures can be installed in series or in parallel (wired to a common junction box). Each fixture requires a dedicated junction box for mounting. Ensure that all junction boxes are suitable for the environment and that all wiring between junction boxes complies with local codes. fixtures can be controlled either with a standard wall switch (on / off) or a commercially available electronic low-voltage (ELV) dimmer. ew Blast Powercore fixtures work with many trailing-edge or reverse-phase control ELV dimmers. Refer to the installation instructions included with the wall of dimmer switch for installing and wiring information. Product Guide 9
Make sure the power is OFF before mounting and connecting fixtures. 1. Install junction boxes. (Refer to the manufacturer s literature for additional items required for mounting or sealing.) 2. If installing fixtures in a series, pull 3-conductor copper wire between the junction boxes. If installing fixtures in parallel, pull 3-conductor copper wire from a common junction box, and from the common junction box to each fixture s junction box. 3. Trim the cable from the fixture to fit in the junction box, leaving enough cable to make wiring connections. 4. Insert the fixture cable through the provided junction box gasket before making wire connections. When attaching the fixture to the junction box, ensure that the gasket is compressed evenly. 5. For UL / cul installations, use wire nuts to connect line (black), neutral (white), and ground (green). For CE installations, use wire nuts to connect line (brown), neutral (blue), and ground (green / yellow). ~ ~ ~ ~ E In locations where US junction boxes are not available, you can mount fixtures directly to a wall or other mounting surface. For help with your specific installation, consult your local support organization, or contact Application Engineering Services at support@colorkinetics.com. E When installing fixtures, the input earth ground, canopy earth ground, and fixture cable earth ground must all be connected together. Fixture cable dimensions.38 in (9.6 mm) 18 AWG.04 in (1 mm) UL UL / cul / cul CE CE 6. Tuck wire connections into the junction box, and use the provided screws to attach the fixture to the junction box. 7. If installing in a wet or damp location, seal all junction boxes with electronicsgrade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes. 8. If installing in parallel, connect the wires from each fixture to the lead wire from the line power source in the common junction box. 9. Connect the wire from the first fixture in the series to the line power source if installing in series, or from the common junction box to the line power source if installing Line in parallel. voltage E Wiring between junction boxes must comply with local codes. RTV Silicone RTV Silicone RTV Silicone Line voltage RTV Silicone Line voltage 10 Product Guide
Safety cable minimum requirements Material Size Construction 316 Stainless Steel 5/64 to 3/16 in (2.0 to 4.8 mm) nominal diameter. Minimum break load must be greater than 400 lb (181 kg) 7 x 7 (49 wires) preformed stranded (Optional) Attach Safety Cable Each fixture is designed for use with a safety cable to tether the fixture to a secure anchor point. When dictated by local or state code or advised by a structural engineer, attach a safety cable to the bracket located on the back of the fixture. Remove the two screws that attach the cable bracket, loop the safety cable over the cable bracket, and reattach to the fixture. Attach the safety cable to the mounting surface using a method that follows the code or engineer s requirements. Aim and Lock the Fixtures Make sure the power is ON before aiming and locking the fixtures. Do not look directly into fixture when aiming and locking. Using the provided 1/8 hex key wrench, loosen the rotation and tilting set screws. Aim the fixtures by rotating the base and tilting the beam as desired. Tighten the two pairs of set screws to lock the fixture in place. 110 1/8 in 350 Product Guide 11
Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts 01803 USA Tel 888.385.5742 Tel 617.423.9999 Fax 617.423.9998 www.philipscolorkinetics.com Copyright 2008 2010 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ew Fuse, ColorGraze, ColorPlay, ColorReach, iw Reach, ew Reach, DIMand, EssentialWhite, ew, icolor, icolor Cove, IntelliWhite, iw, iplayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. Cover Photo: John Brandon Miller Photography DAS-000024-00 R05 12-10