JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

Similar documents
JUNG PUMPEN compli 100 MC Sewage lifting stations

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

JUNG PUMPEN MULTICUT SEWAGE PUMPS

10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

jung pumpen CATALOGUE RESIDENTIAL TECHNOLOGY RELEASE 20

Instruction Manual. Sewage lifting station compli 300

JUNG PUMPEN BAUFIX 200. Instruction Manual

Aqualift F XL Lifting Stations

DRD - DRS - DRF. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron

Series description: Wilo-DrainLift KH 32

Poly-sump PKS-B 800 for submersible sewage pumps With plastic valves and guide rail. Application. Description

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Series description: Wilo-Drain STS 40

Series description: Wilo-Drain MTC

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150

Sewage transport Submersible pumps

Design details Design. Installation types. Shaft seal. Impeller type. Drive. Bearings

SUBMERSIBLE SEWAGE PUMPS WITH SEMI-VORTEX IMPELLER in cast iron

Grey Water and Condensate Pump. Rotex. Type Series Booklet

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

SE M.C.N.51D

Dewatering Submersible sewage pumps

ABS submersible sewage pump AFP

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (VORTEX) in cast iron

Side channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

LIFTSON M-LIX L. LIFT-PUMP MODULES Domestic waste water 50 Hz Complies with standard EN RANGE OF APPLICATION APPLICATIONS ADVANTAGES

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

Position Qty. Description Single Price

Separators. industrieblick Fotolia.com. For indoor or below ground installation ACO Light Oil Separators Coalisator-P

Ebara Submersible Sewage Pumps (Single Channel Impeller)

SUBMERSIBLE SEMI-VORTEX SEWAGE PUMPS

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

MODEL Kg H x W x L mm LM/HM kw CODE PRICE

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

MYERS MODELS 4RC AND 4RCX

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

MYERS MODELS 4VC & 4VCX

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Rangess AK, KXAKX Discharge Size DN 200 DN

Data sheet. KRTF /24XEG-S IE3 Version no.: 3. Operating data. Design. Driver, accessories

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz

GY/UY GRINDER / VORTEX SERIES

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

SUBMERSIBLE ELECTRIC PUMPS FOR FOUL WASTE WATER (SINGLE CHANNEL) in cast iron

DML - DMLV. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron 3,7 5,5 7, LM 80 OUTPUT DIAMETER 80

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

MYERS 4VCDP. 4" Solids Handling

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

Dewatering pumps for raw water pumping. / / grundfos DW RANGE

MYERS MODELS 6VC & 6VCX

in cast iron Your Life, our Quality. Worldwide. 65 Wastewater Submersible sewage pumps ( single-channel) in cast iron

SUBMERSIBLE PUMP RANGE

Drainage pumps Series KEP

SUBMERSIBLE SEWAGE PUMPS (GRINDER) in cast iron

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m

Multilift M, MD, MDV, and MD1 ranges

Submersible Stainless Steel Semi-Vortex Pumps Pumps

Thermoplastic Centrifugal pump, Type NM

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SUBMERSIBLE SEWAGE PUMPS (VORTEX) in cast iron

DMLV - DMLVF. SUBMERSIBLE SEWAGE PUMPS (VORTEX) in cast iron. Your Life, our Quality. Worldwide. 80 Wastewater

COLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS

MYERS MODELS 4R AND 4RX

Ama-Drainer-Box Type Series Booklet

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

MYERS MODELS 4V AND 4VX

Side channel pumps PN 16 SOH - SOHB - SOHM. Self-priming centrifugal pumps. Technical description

Priox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Submersible Grinder Pumps Type ABS Piranha

GRUNDFOS WASTEWATER. S range kw. 50 and 60 Hz versions

Backflushing Filter AutoFilt RF3

Electric submersible pumps SEMISOM for sewage water

GRUNDFOS DATA BOOKLET. Multilift. Lifting stations 50 Hz

Series description: Wilo-Drain TM/TMW/TMR 32

2 HYDROO NISO/NIS SERIES 3

Liquid ring compressors

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Ama Porter. 50 Hz. Submersible motor pumps

JUNG PUMPEN CONTROL UNITS

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Submersible Motor Pump. Amarex N. 60 Hz. Type Series Booklet

Data sheet. Omega B GB G F Version no.: 1. Operating data. Design. Driver, accessories. Clean water. Actual developed head 57.

ABS lifting station Synconta

Drainage pumps Series KEP

Purpose & Advantages

- continuos running: max ±5%. - intermittent running: max ±10%. Voltage imbalance between phases: max 2%. Maximum number of starts per hour: 30.

DW - DW VOX SUBMERSIBLE SEWAGE PUMPS

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Transcription:

APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In order to ensure a practical arrangement, special importance was attached to easy installation. The submersible unit is permitted for general use in areas subject to flooding without requiring additional outlay. The control unit has to be fitted in a well ventilated flood-proof room. The construction with PE tanks has freely accessible drains and a clamp-type inlet flange for easy installation. The topmounted cleaning opening and the easy replaceability of the pre-mounted pumps also ensure time-saving servicing. For application areas with special obligations for fire protection like airports or underground railways we recommend our sewage liftings stations in stainless steel on request. Submersible Large storage capacity Selectable inlet position PE-tank compli 1500 compli 2500 PERFORMANCE PERFORMANCE Operative limit Discharge pipe DN100 Single channel impeller 50Hz 2800RPM Discharge DN80/DN100 23695-02 45220-02 We reserve the right to change specifications without notice Pump performance is subject to ISO 9906 tolerances The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056. This data is represented in the performance curve as a limit of application. D 204-4.4-EN-1607 1

Type Tank capacity l Inlet height mm Free passage mm Clamp-type inlet flange Connecting flange PN 10 For connecting pipe Ventilation Weight approx. Code No. Duplex system with one tank compli 1525/4 C1 500 700 100 DN 150 DN 100 DN 100 DN 70 253.5 kg JP09181 compli 1535/4 C1 500 700 100 DN 150 DN 100 DN 100 DN 70 261.5 kg JP09182 compli 1555/4 C5 500 700 100 DN 150 DN 100 DN 100 DN 70 363.5 kg JP09183 compli 1575/4 C5 500 700 100 DN 150 DN 100 DN 100 DN 70 373.5 kg JP09184 compli 1575/4 B6 500 700 70 DN 150 DN 100 DN 100 DN 70 357.5 kg JP09185 compli 1535/2 B2 500 700 70 DN 150 DN 80 DN 100 DN 70 235.5 kg JP45933 compli 1555/2 B2 500 700 70 DN 150 DN 80 DN 100 DN 70 301.5 kg JP45934 compli 1575/2 B5 500 700 70 DN 150 DN 80 DN 100 DN 70 321.5 kg JP45141 compli 15100/2 B5 500 700 70 DN 150 DN 80 DN 100 DN 70 367.5 kg JP45142 compli 15200/2 B6 500 700 70 DN 150 DN 100 DN 100 DN 70 549.5 kg JP45935 Duplex system with two tanks compli 2525/4 C1 1000 700 100 DN 150 DN 100 DN 100 DN 70 300.5 kg JP09186 compli 2535/4 C1 1000 700 100 DN 150 DN 100 DN 100 DN 70 308.5 kg JP09187 compli 2555/4 C5 1000 700 100 DN 150 DN 100 DN 100 DN 70 410.5 kg JP09188 compli 2575/4 C5 1000 700 100 DN 150 DN 100 DN 100 DN 70 420.5 kg JP09189 compli 2575/4 B6 1000 700 70 DN 150 DN 100 DN 100 DN 70 404.5 kg JP09190 compli 2535/2 B2 1000 700 70 DN 150 DN 80 DN 100 DN 70 282.5 kg JP45936 compli 2555/2 B2 1000 700 70 DN 150 DN 80 DN 100 DN 70 348.5 kg JP45937 compli 2575/2 B5 1000 700 70 DN 150 DN 80 DN 100 DN 70 368.5 kg JP45938 compli 25100/2 B5 1000 700 70 DN 150 DN 80 DN 100 DN 70 414.5 kg JP45939 compli 25200/2 B6 1000 700 70 DN 150 DN 100 DN 100 DN 70 596.5 kg JP45940 PERFORMANCE Type Delivery head H [m] 4 5 6 7 8 9 10 11 12 13 14 16 18 20 compli...25/4 C1 Flow rate Q [m 3 /h] 104 87 71 51 32 16 compli...35/4 C1 103 89 72 54 36 21 compli...55/4 C5 100 87 74 59 45 22 compli...75/4 C5 100 87 75 44 22 compli...75/4 B6 91 82 62 41 24 Type Delivery head H [m] 5 6 7 8 9 10 13 16 19 22 25 28 31 34 37 40 42 47 compli...35/2 B2 Flow rate Q [m 3 /h] 103 97 89 81 73 65 40 16 compli...55/2 B2 103 97 91 85 78 58 37 18 compli...75/2 B5 104 88 71 54 37 23 11 compli 100/2 B5 91 76 55 41 32 15 4 compli 200/2 B6 100 86 73 58 43 33 15 ELECTRICAL DATA Type Type of Voltage Motor rating kw Current RPM Cable quality Cable current Volt P1 P2 Ampere min-1 H07RN-Fcompli length...25/4 C1 3-phase 3/N/PE~400 2.4 1.90 4.2 1395 6 G 1.5 10 m compli...35/4 C1 3-phase 3/N/PE~400 3.5 2.65 6.9 1424 6 G 1.5 10 m compli...55/4 C5 3-phase 3/N/PE~400 5.8 4.65 10.2 / 5.9 1430 10 G 2.5 10 m compli...75/4 C5 3-phase 3/N/PE~400 7.2 5.90 12.8 / 7.4 1432 10 G 2.5 10 m compli...75/4 B6 3-phase 3/N/PE~400 7.2 5.90 12.8 / 7.4 1432 10 G 2.5 10 m compli...35/2 B2 3-phase 3/N/PE~400 3.7 3.04 11.5 / 6.6 2895 6 G 1.5 10 m compli...55/2 B2 3-phase 3/N/PE~400 5.2 4.45 8.7 / 5.0 2910 10 G 2.5 10 m compli...75/2 B5 3-phase 3/N/PE~400 7.7 6.60 13.2 / 7.7 2925 10 G 2.5 10 m compli 100/2 B5 3-phase 3/N/PE~400 10.5 9.20 17.6 / 10.2 2920 10 G 2.5 10 m compli 200/2 B6 3-phase 3/N/PE~400 17.3 15.4 28.8 / 16.7 2940 10 G 2.5 10 m 2

ACCESSORIES Code No. 1 2 3 Seal leak detector DKG In case of duplex systems two units have to be taken into consideration. Rechargeable battery for control for mains-independent alarm Sluice valve with two pipe sockets for 6 inlet and tank connection (DN 150) H B E F D 660 450 110 105 160 JP44900 JP44850 JP28591 4 Maintenance valve with pipe socket (DN 100) H B E F D 300 295 60 81 174 JP45173 5 Sluice valve* for 4 pressure side (DN 100), PN 10, DIN EN 1171 H B E D 345 190 DN 100 for 4 pressure side JP00329 6 Swing-type check valve R 101* PN 4, flange PN 10, DIN 3202, DIN EN 12050-4 without counterweight Swing-type check valve R 100 G* PN 4, flange PN 10, DIN 3202, DIN EN 12050-4 with adjustable counterweight H D/DN 300 100 JP00325 JP00324 7 Hand diaphragm pump for emergency purposes (up to H geod 15 m) H E D ca. 640 430 1½ JP00255 8 Stop valve, 1½ (DN 40), PN 16 9 Elastic connection 1½ (DN 40), PN 4 H B D 125 max. 60 1½ H D 120 50 JP44786 JP44777 10 Clamp 1½ JP44763 11 Flanged connection* (similar to Q unit 90 ), C 100 (similar to Q-Stück 90 ), B 80 für B5, B2 H B C/DN D/DN 175 120 100 PN 10 100 PN 6 150 100 80 PN 10 80 PN 6 JP00579 JP00578 12 Y-ducting* DN 100/100/100, PN 10 (only for compli 1500) H B C/DN D/DN 355 480 100 100 JP00203 13 Flanged spigot F-KS* for pressure side, DN 100, plastic pipe Welded connection* (F unit), for pressure side, C 100, steel pipe Elastic connection 4" (DN 100), PN 4 for pressure side, DN 100, plastic pipe H D C/DN Flansch 153 110 100 PN 10 JP08673 100 114 100 PN 10 JP00688 H D JP44778 200 110 14 H D for pressure side, DN 100, steel pipe JP44774 200 114 15 Clamp 4 JP44767 16 Reducing adapter* for B5, B2 (similar to FFR-piece to PN 10) H C/DN D/DN 100 80 100 JP00498 17 Tank, 500 l JP45945 * with screws and seal 3

Dimensions compli 1500 (mm) Dimensions compli 2500 (mm) 43009-04 43010-02 In case of a chamber, plan 60 cm working space around all parts which have to be serviced. In case of a chamber, plan 60 cm working space around all parts which have to be serviced. Mounting dimensions compli 1500 (mm) Mounting dimensions compli 2500 (mm) casing casing 20778-05 20779-04 4

Mounting arrangement of compli 1500 Mounting arrangement of compli 2500 to be provided at site 22529-04 22530-04 Mounting arrangement of compli 1500 Mounting arrangement of compli 2500 45106-00 45107-00 5

TECHNICAL DATA Pump Vertical, single-stage, submersible, single-vane impeller with spiral housing and horizontal outlet flanged on to a stable duckfoot bend as well as low-noise and low-vibration absorber. Bearing Common shaft for pump and motor, grease-packed ball bearing. Motor Submersible, IP 68 type of protection, insulation class F, winding thermostats for the protection of the drives against overheating, automatic start-up by three-contact circuit and control, operating mode S3 in keeping with VDE. Seal Silicon-carbide mechanical seal independent of the sense of rotation, oil chamber and artificial carbon mechanical seal (or duplex rotary shaft seal) to motor compartment, safe to run dry, connection options for seal leak detector. Materials Tank made of corrosion-resistant and environmentally friendly polyethylene, pump and motor housing, impeller and duckfoot bend made of wear-resistant grey cast iron, shaft completely covered against the material to be transported, rubber insulated hose. Scope of supply Tank system in keeping with German / international standard DIN EN 12050 in assembly groups, prepared for final assembly on site: Tank with clamp-type flange DN 150, two mounted submersible pumps and automatic level control, duckfoot bend, mounting material, elastic connections for the DN 70 ventilation and duckfoot bend connections with clamps, control with motor protection for automatic two-way connection with mains-dependent alarm system, potential-free contact for collective failure messages, hand-0-automatic switch and optical display of sense of rotation, alarm and operation. To be fitted with a micro-processor control as well upon request. Cable between pump and control 10 m. Accessories to be ordered according to mounting drawing. Mounting arrangement with additional tank Mounting arrangement 20894-03 45999-00 In keeping with the construction and testing principles of German / European standard DIN EN 12050, sewage disposal units are to be used for the transport of faecal matter and domestic waste-water in building drainage systems as described in German standard DIN 1986 T3. In keeping with the stipulations of German / European standard DIN EN 12056-4 they have to be mounted with collecting tanks inside building permitting a free space of 60 cm for operation and repair. The pressure pipe has to be passed above the locally defined backpressure level and a non-return valve tested in keeping with German / European standard 12050-4 has to be mounted. In keeping with German / European standard 12056 the ventilation pipe has to be passed up to the roof. 6 PUMP TECHNICAL SERVICES LTD. Pump House Unit 12 Bilton Road Industrial Estate Erith Kent DA8 2AN Phone 01322 357080 Fax 01322 341341 sales@pts-jung.co.uk www.pts-jung.co.uk Jung Pumpen GmbH 33803 Steinhagen Germany Phone +49 5204 17-0 Fax +49 5204 80368 info@jung-pumpen.de www.jung-pumpen.de