Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

Similar documents
Flush-mounted pressure and level transmitters - KERAMESS KS S 200/201 - Superior Precision

Flush-mounted pressure and level transmitters - TPF series 100/101 -

SITRANS P measuring instruments for pressure

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure transmitter for elevated media temperatures

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

JUMO dtrans p20 DELTA

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO MIDAS Pressure transmitter

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

- Quicktemp TP62/TW39...T500 -

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure Transmitter JUMO dtrans p30 Type

Pressure transducer DMU 01K Compact version

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Compact Pressure Transmitter DAN-HH

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Pressure Transmitters for Sanitary Applications Model SA-11

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Pressure Transmitter JUMO dtrans p30 Type

Pressure transmitter PASCAL CV4

Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

JUMO MIDAS S05 Pressure transmitter Type

Pressure transmitter UNIVERSAL CA

Pressure transmitter COMPACT ECOnomic

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Pressure transmitter for industrial applications Type MBS 4510

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

OPTISWITCH 6500 C Technical Datasheet

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Portable pressure calibrator, Wally Box III Model CPH7600

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

OPTISWITCH 6500 C Technical Datasheet

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Pressure transmitters for industrial applications Type MBS 4510

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Differential pressure transmitter PASCAL Ci4 Delta P

GEMÜ 539 esydrive Motorized globe valve

SPT- I / U PRESSURE TRANSMITTER for general applications

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Continuous Level Sensor NSL-F

Electronic Pressure Switch EDS 3000

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Pressure/Level Transmitters with Flush - Mounted Diaphragm

CTE7000 / CTU7000 Series Miniature pressure transmitters

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P

LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

The right choice for your application. Pressure sensors from ifm.

p Additional dimensions see section dimensions.

CTE8000 / CTU8000 Series

GEMÜ 549 esydrive Motorized globe valve

Magnetic-inductive flow measurement device Type VOLUMTEC - best performance

Industrial Pressure Transmitters

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Mini Pressure Transmitter HA7

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Electronic pressure switch with integrated analogue output

Paddle-wheel flow controller for On/Off control

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information

Insertion magnetic inductive flowmeter

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

SATRON VDt Differential Pressure Transmitter

Pressure transmitter for industrial applications Type MBS 4500

Industrial Pressure Transmitter

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Differential Pressure Sensors

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Differential Pressure and Flow meters Accessories for the Media Series

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Differential Pressure Sensors

Temperature Sensor without thread

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Beck. The differential pressure transmitter for air with IP65

Magnetic Inductive Flow

SATRON VTe pressure transmitter

Pressure transmitter for marine applications MBS 3100 and MBS 3150

SATRON VVFe Pressure Transmitter

Modular Pharma Pressure Transmitter MPP

ECT Applications. Features

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Differential Pressure Sensors

Transcription:

FEATURES PRECISE MEASUREMENTS WITH AN ACCURACY OF ± 0.15% FS WITH DRY CERAMIC MEASURING CELL TURN-DOWN 10 EASY TO CLEAN AND HIGH PROTECTION CLASSES IP67 AND IP69K INTEGRATED ON-SITE DISPLAY OR EXTERNAL OPUSM DISPLAY AND OPERATING MODULE FOR PARAMETRISATION AND DISPLAY OF MEASURING VALUES APPLICATION STRENGTHS: MEASUREMENT OF THE CONTENT AND PROCESS PRESSURE WITH SMALL MEASURING RANGES WITH AN OVERLOAD-SAFE CERAMIC MEASURING CELL, ALSO SUITABLE FOR ABRASIVE MEDIA DIRECT ENTRY OF PARAMETERS WITH PLAIN TEXT DISPLAY DESCRIPTION The KERAMESS pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The wide range of process connections enables use in all applications in the food and pharmaceutical industries. Customer-specific process connections are also possible on request. The vacuum-proof and extremely overload safe measuring cell with a ceramic membrane made of highly pure aluminium oxide works on the basis of the capacitive measuring principle. The KERAMESS pressure transmitters are designed to measure from -1/0 1 to -1/0 70bar. The measuring ranges 0...0.05bar and -0.1...+0.1bar are available alongside other special measuring ranges. Thanks to the ceramic membrane, the KERAMESS pressure transmitters are particularly suited for aggressive and abrasive media. The design for long-term medium temperatures of up to 125 C enables CIP and SIP cleaning methods to be used on the transmitters. The high protection classes of IP67 and IP69K guarantee that the devices can be safely cleaned on the outside with foam and a high-pressure cleaner and that moisture is reliably prevented from entering into the device. For additional protection against moisture, the electronics are fully encapsulated in the housing. All the pressure transmitters in series 100/101 are designed for universal applications and, in particular, for applications with constantly high temperatures of up to 125 C. Furthermore, using the on-site display with series 100 and the display and operating module OPUSM in series 101, the pressure transmitters can be simply read out, configured and diagnosed. PN-KS-100-101-EN-1610/1

TECHNICAL DATA General details Device type / measuring principle KS 100/101: capacitive Input Measuring ranges KS 100/101 Standard nominal measuring ranges [bar] relative OP relative OP absolute OP 0.05 4 40 60 0.1 4 OP = overload protection [bar] 0.1 4 70 105 0.2 6 ±0.1 4-1...1 10 0.4 6 0.2 6-1...2 18 1 10 0.4 6-1...4 25 2 18 Special measuring ranges are available on request. All measuring cells are vacuum-proof Setting the measuring ranges 1 10-1...10 40 4 25 2 18-1...20 40 10 40 4 25-1...40 60 20 40 10 40-1...70 105 40 60 20 40 70 105 Via the keypad of the OPUSM display and operating module / via the integrated on-site display Setting ranges Start the measuring zero: 0...90% of the sensor's nominal measuring span Measuring span span: 10...100% of the sensor's nominal measuring span Burst pressure DIN16086 4-fold measuring range Output Output signal 2-wire: 4...20mA with a test circuit connection in the device Fault signal Optional: 3.8mA, 22mA, hold (i.e. holding the last value) Current limitation 3.85mA and 21.5mA (normal operation) Integration time Continuously selectable between 0 and 300s (setting time after a pressure leap) Measuring accuracy Reference conditions acc. to DIN IEC 770 Linearity, hysteresis and repeatability ± 0.15% of the sensor's nominal measuring range as per the limit point method DIN IEC 770 Activation time < 5s (the device will carry out a self-test.) Setting time (without damping) < 200ms Long-time drift 0.2% of the span per year Thermal hysteresis ± 0.75% beginning of the measuring range / ± 0.8% end of the measuring range Conditions of use Installation position / calibration Any position / standing vertically (position-dependent zero point displacement) position Medium temperature T1: -40...+125 C (140 C over one hour at the most) Ambient storage temperature Type 101: -40...+85 C Type 100: -30...+75 C (Below -20 C cable breakage might occur and the display's function may be impaired.) Protection class acc. to EN60529 IP 67 and IP 69K Electromagnetic compatibility Sensitivity against interference: acc. to DIN IEC 61000-6-2 Interference radiation: acc. to DIN IEC 61000-6-4 Construction Electrical connection Process connection - Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request - Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request - Optional: angle plug acc. to EN 175301-803 - Optional: reference cable - All standard front-mounted process connections and those that are commonly used by the manufacturer Materials - Field housing / lid: CrNiSt 1.4301 (304) - Housing seal: FPM (Viton ) - Pressure compensation element: polyamide - Inspection gauge (type 100): polycarbonate - Process connection: CrNiSt 1.4404 (316L) - Process membrane: Al 2 O 3 (99%) - Locking screw (type 101): CrNiSt 1.4301 (304) - Reference cable: 5-wire with reference tube: PUR (recommended: 80m maximum) TD=10 PN-KS-100-101-EN-1610/2

TECHNICAL DATA Display and operation Display LCD, 4-digit numerical display and 5-digit alphanumerical display Type 100: integrated on-site display (cannot be separated from device) Type 101: external OPUSM display and operating module Displayable units Pressure: mbar, bar, psi, Pa, mh2o, mmhg, Torr, atm, at, kg/cm² Volume: l, hl, dm³, m³, ft³, US gal, UK gal, US bl, UK bl Mass: kg, t, lbs, tn. sh., tn. l. Additional displays Output current in ma or % (in relation to the span) Operation Type 100: via the configuration menu with the integrated on-site display Type 101:via the configuration menu with the external OPUSM display and operating module Auxiliary energy resources Power supply / burden 12-36V DC, max. burden: (V supply 12V) / 24mA Accessories 100 series OPUSM display and operating module Certificates External display and operating module, CrNiSt, IP 67, 41x70mm, 1m connection cable and round plug-in connector M12x1 Calibration certificate Declaration of conformity Material inspection certificates as per EN 10204 DIMENSIONED DRAWINGS (dimensions in mm) KERAMESS 100... _K(M) KERAMESS 101... _K(M) Druckausgleich pressure equalization M16x1,5 (M12-Stecker) M16x1,5 (M12 circular connector) Anschluss für OPUS connection for OPUS OPUS Hengesbach Prozessmesstechnik 132.5 MBAR SPAN ZERO P Feldgehäuse mit integrierter Anzeige (Edelstahl, IP67 + IP69K EN 60529) field-housing with integrated display (stainless steel, IP67 + IP69K EN 60529) Feldgehäuse für OPUS (Edelstahl, IP67 EN 60529) field-housing for OPUS (stainless steel, IP67 EN 60529) Anzeige display Prozessanschlüsse (weitere Ausführungen auf Anfrage) process-connections (other constructions on request) aseptischer Anschluss (N3) aseptical process-connection (N3) VARIVENT-Flansch Ø68 (V8) VARIVENT-flange Ø68 (V8) DRD-Flansch Ø65 (D6) DRD-flange Ø65 (D6) PN-KS-100-101-EN-1610/3

DIMENSIONED DRAWINGS (dimensions in mm) Clamp DIN 32676 - DN50 (C5) Kegelstutzen DIN 11851 conical nozzle DIN 11851 DN40 (M4), DN50 (M5) Einschraubgewinde DIN ISO 228 G11/2B (G5) external thread DIN ISO 228 G11/2B (G5) A B C D E F DN50 Ø102 Ø125 Ø165 20 3 4xØ18 DN80 Ø138 Ø160 Ø200 24 3,5 8xØ18 Einschraubgewinde EN 837 G1/2B (G2) external thread EN 837 G1/2B (G2) Flansch EN 1092-1 flange EN 1092-1 DN50 (F5), DN80 (F6) Einschweißmuffe (PEM1FKSN) für Anschluss (N3) welded socket (PEM1FKSN) for process-connection (N3) PN-KS-100-101-EN-1610/4

ELECTRICAL CONNECTION The standard electrical connection is via a cable screw connection M16x1.5. On removing the device lid, the connection is created using screw terminals. The connection diagram in the transmitter head can be seen in the figure below: The supply voltage is connected via the two terminals 1 (+) and 2 (-). The current flowing in this loop represents the existing measuring value. The terminals TE and ST provide a test circuit connection with which the actual loop current can be measured without interruption using an ammeter. The ground terminal is for potential equalisation between the measuring device and the measuring point. Alternative connection options are a round plug-in connector M12x1, an angle plug acc. to EN 175301-803 as well as a factory-fitted reference cable with integrated vent capillary. The reference cable comes in lengths of between 1...80m. The electrical configurations are listed in the following: Round plug-in connector M12x1 Angle plug acc. to EN 175301-803 Connected reference cable Brown Supply + Black Supply - White Earth Shield Earth CALIBRATION / SETTING Factory configuration Measuring range calibrated: Current output: Damping: Mains frequency: Measuring value / measuring unit Current output in the event of a fault: Nominal measuring range or as per the order data 4...20mA with extended span between 3.9 and 21mA 0s 50Hz Pressure / mbar hold (last value is held) PN-KS-100-101-EN-1610/5

Configuration menu / parameter list (basic settings of the first parameter level) No. Parameter Explanation P-0 OFSET P-1 SPAN Offset Span This parameter is used for setting the beginning of the measuring range. The value, which is set here, is assigned the output current of 4mA. The adjustable range is between 0...90% of the sensor's nominal measuring range. The span sets the end value for the measuring range. The value, which is set here, represents an output current of 20mA. The adjustable range is within 10...100% of the sensor's nominal measuring range. P-2 I OUT P-3 DAMP P-4 MAINS P-5 UNIT P-6 DISPL P-7 BIAS P-8 LIMIT P-9 LOCK Output current Damping Mains frequency Measuring unit Measuring value Inlet pressure Trailing pointer Device lock The current range of 4...20mA can by inverted if required. The beginning of the measuring range, in its inverted state, corresponds to 20mA, and the end of the measuring range to 4mA accordingly. If the pressure conditions vary heavily, the measuring value can be settled by activating the damping function. The setting of the mains frequency, which is used at the respective operating location, serves to suppress any interference inside the device. This way, the mains noise of the power supply unit can be cut out to a large extent. This setting is used for selecting between different measuring units depending on the measuring value (pressure, volume, mass), which is currently displayed. This parameter allows the selection of the displayed measuring value. Depending on the device configuration, you can choose between the pressure, current or percentage. A possible offset pressure, which should not be included in the measuring result, can be hidden by entering an inlet pressure / bias. This is particularly useful for volume measurements in pressurised tanks. The device continuously writes the minimum and maximum values of the process pressure. Using this data, it can be established whether the transmitter was operated outside of its permissible range. For parameters in which device settings can be made, a device lock can be activated. This prevent changes being made to the device inadvertently. P-10 I ERR P-11 VERSN Current in the event of an error Version If the transmitter is faulty, the output current can either assume the lower limit (3.8mA), upper limit (22mA) or the last valid value (hold). Both the version of the installed hardware (electronics) and the software (firmware) in the device can be viewed under this parameter. In the event of a fault it is possible to draw conclusions regarding the revision of the device. Configuration menu / parameter list (basic settings of the first parameter level) Rundsteckverbinder circular connector Kabelverschraubung cable gland Parametrisation of the transmitter as well as of the measuring value display on site is handled by the on-site display integrated in the device (type 100) or via the OPUSM (type 101) display and operating module located in external housing. externes Bedienmodul OPUS external operation module OPUS PN-KS-100-101-EN-1610/6

ORDER INFORMATION for KERAMESS KS Electronics 100 4...20mA, integrated LCD display, TD 10 101 4...20mA, can be operated with OPUSM, TD 10 Process connection C5 D6 F5 F6 G2 G5 M4 M5 N3 V8 S9 Clamp acc. to DIN32676 DN50, front-mounted DRD flange Ø 65mm Flange acc. to EN 1092-1 (DIN2527 D) DN50 / PN10-40, front-mounted Flange acc. to EN 1092-1 (DIN2527 D) DN80 / PN10-40, front-mounted Screw-in thread G½"B, acc. to EN837, interior sensor (manometer connection) Screw-in thread G1½"B, acc. to ISO228, front-mounted Conical coupling with a groove union nut acc. to DIN 11851, DN40 / PN40, front-mounted Conical coupling with a groove union nut acc. to DIN 11851, DN50 / PN25, front-mounted Aseptic process connection with a groove union nut VARIVENT flange Ø 68mm / PN40, for pipe DN 40-125, front-mounted Other process connections available on request. Pressure type / sensor's measuring range A 0.05bar max. overload 4bar B 0.1bar max. overload 4bar T 0.2bar max. overload 6bar D 0.4bar max. overload 6bar E 1bar max. overload 10bar F 2bar max. overload 18bar H 4bar max. overload 25bar K 10bar max. overload 40bar L 20bar max. overload 40bar N 40bar max. overload 60bar P 70bar max. overload 105bar R Relative pressure, overpressure (0...xxx bar) N Relative pressure, vacuum (-1...xxx bar) A Absolute pressure Electrical connection K Cable screw connection M16x1.5 M Round plug-in connector M12x1 W Right-angle connector EN 175301-803 (not with 200/200H) R05 Reference cable, 5m, securely fixed R10 Reference cable, 10m, securely fixed R15 Reference cable, 15m, securely fixed R20 Reference cable, 20m, securely fixed RXX Reference cable, length in excess of 20m is to be stated in plain text (max. 80m) Run options 2 EPDM (FDA-compliant) 3 FKM (O-ring) 4 FKM (FDA-compliant) 5 FFKM (O-ring) KS Nominal measuring range if different from sensor's measuring range PN-KS-100-101-EN-1610/7

ORDER INFORMATION for KERAMESS KS accessories Accessories/assembly parts (please order separately) Article number OPUSM external operating module, for electronics 101, 1.4301 (304) OPUSM Compression fitting for process connection N3, 1.4404 (316L) PEM1FKSN DRD weld-in block flange DRD, 1.4435 (316L) ZEB1FDRD Flat seal made of EPDM for DRD flange ZFA1FDRD Flat seal made of FPM (Viton ) for DRD flange ZFC1FDRD Flat seal made of PTFE (Gore ) for DRD flange (FDA) ZFD1FDRD 4 x fastening screws for DRD flange, 1.4301 (304) ZDS4FDRD Pressure compensation element, "Gore prevent", IP69K ZDAE69K Locking screw for OPUSM connection with series 101, 1.4301 (304) ZVS1F101 Reference cable made of PUR with pressure compensation capillary ZKP1FDMU Approval certificate 3.1 acc. to EN 10204 for compression fittings WZ31 Certificate of compliance 2.1 acc. to EN 10204 WZ2.1 Test report 2.2 acc. to EN 10204 WZ2.2 Please observe the permissible nominal pressure of the process connection selected. All specifications and certifications specified are only guaranteed when Hengesbach original components are used. Our devices are subject to constant development; subject to technical modification. PN-KS-100-101-EN-1610/8