AS/NZS AS/NZS

Similar documents
Certificate of Conformity self-generation unit

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

Jemena Electricity Networks (Vic) Ltd

SA Power Networks Commissioning Witnessing Checklist

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Installation Couplers intended for permanent connection in fixed installation

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Technical Data Sheets

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

Net Metering Interconnection Requirements

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Net +Plus Connection Code

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Technical Requirements for Renewable Energy Power System

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

< > Page 2 of 84

.3 Section Waste Management and Disposal.

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

RULES & REGULATIONS FOR RENEWABLE GENERATION SYSTEMS 2. SUMMARY OF APPLICATION AND INTERCONNECTION PROCESS

Technical Data Sheets

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

TANZANIA BUREAU OF STANDARDS

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Smart connections. Certificates. PIKO-Inverter

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Connectors Safety requirements and tests

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

TEST REPORT IEC Connectors Safety requirements and tests

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

E-15 Uninterruptible Power Systems (UPS)

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Page 2 of 23 UNT150420C11

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

E-15 Uninterruptible Power Systems (UPS)

Page 2 of 39 Report No. CTI PA Testing location:

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Technical Data Sheets

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Page 3 of 34 Report No Part I

Illuminator Series CR NEMA 3R

COVER PAGE FOR TEST REPORT

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Harmonic current emissions as EN Harmonic Test Value in Amps % of fund Limit value in Amps

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

Draft Guideline for the connection of smallscale inverter based distributed generation. EEA Asset Management Forum 22 June 2016 Dr Richard Strahan

Technical Standard - TS 129. Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW. SA Power Networks. Published: November 2017

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Industrial PFC UPS System

Technical Data Sheets

Guidelines for connection of generators:

EU RO Mutual Recognition Technical Requirements

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

MGE TM Galaxy TM 6000 : Specification guide. Single UPS, three-phase, 250 to 600 kva

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Electric Networks/Ina Lehto Updated Original 12/2011

University of Houston Master Construction Specifications Insert Project Name

Technical specifications

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Sola/Hevi-Duty S3K Series Mini-Tower UPS

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Sunny Tripower. Can do everything that we can

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

DART Charger Product Description, Information and Specification

INTERNATIONAL STANDARD

IEC Information technology equipment Safety Part 1: General requirements

Standard specification Galaxy PWi, three-phase, 10 to 200 kva

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Transcription:

TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total number of pages......: 15 Testing laboratory name... : Address... : Bureau Veritas Consumer roducts Services Germany GmbH Businesspark A96 86842 Türkheim Germany Applicant's name... : Address... : SMA Solar Technology AG Sonnenallee 1, 34266 Niestetal Test specification Standard... : AS/NZS 4777.2:2005 AS/NZS 4777.3:2005 Certificate... : Certificate of suitability Test report form number.... : AS/NZS 4777 Master TRF... : Bureau Veritas Consumer roducts Services Germany GmbH Test item description... : Battery inverter Trademark... : Model / Type... : SI8.0H-11, SI6.0H-11 Ratings... : SI8.0H-11 SI6.0H-11 Input DC voltage range [V]... : Input DC current [A]... : range: 41V 63V nom. 48V In nom.: 136A Out nom.: 115A range: 41V 63V nom. 48V In nom.: 103A Out nom.: 90A Output AC voltage [V]... : 230V / 50Hz 230V / 50Hz Output AC current [A]... : In nom.: 26,1A Out nom.: 50A In nom.: 20A Out nom.: 50A Output power [VA]... : 6000W 4600W Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 2 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Testing Location... : Address... : Tested by (name and signature)... : Approved by (name and signature)... : Bureau Veritas Consumer roducts Services Germany GmbH Businesspark A96, 86842 Türkheim, Germany Alastair Schmid Georg Loritz Manufacturer s name... : SMA Solar Technology AG Factory address... : Sonnenallee 1 34266 Niestetal Germany Document History Date Internal reference Modification / Change / Status Revision 2014-01-22 Alastair Schmid Initial report was written 0 Supplementary information: Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 3 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Test items particulars Equipment mobility...: ermanent connection Operating condition...: Continuous Class of equipment...: Class I rotection against ingress of water...: I54 according to EN 60529 Mass of equipment [kg]...: 63 Test case verdicts Test case does not apply to the test object... : Test item does meet the requirement... : Test item does not meet the requirement... : N/A (ass) F(ail) Testing Date of receipt of test item... : 2013-11-19 Date(s) of performance of test... : 2014-01-21 until 2014-01-22 General remarks: The test result presented in this report relate only to the object(s) tested. This report must not be reproduced in part or in full without the written approval of the issuing testing laboratory. (see Annex #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. The unit was reviewed to AS/NZS 4777.2:2005 Grid connection of energy systems via inverters, art 2: Inverter requirements AS/NZS 4777.3:2005 Grid connection of energy systems via inverters, art 3: Grid protection requirements and the unit fulfils the requirements of the European EMC directive requirements. The EMC requirements of AS/NZS 4777.2 (flicker) refer to the same standards as the EMC directive; therefore the EMC report documents show the compliance. The grid trip tests were conducted as per clause B4, Appendix B of AS/NZS 4777.3. This Test Report consists of the following documents: 1. Test Results 2. Annex No. 1 EMC Test Report 3. Annex No. 2 ictures of the unit 4. Annex No. 3 Test equipment list Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 4 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Copy of marking plate: Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 5 of 15 Report No.: 13TH0287-AS/NZS 4777_0 General product information The battery inverter converts DC voltage from a battery into AC voltage. 1. The ambient temperature range is specified as -25 to +60 C 2. Dimension of EUT: 467 by 612 by 242 mm. 3. The model SI6.0H-11 which are part of this report provides the same construction and differ only in the power rating which is limited by software of the model SI8.0H-11 The inverter supplies AC loads in the grid from a battery or charges the battery with the energy provided by sources on the AC side. AC sources in the grid supply loads and are used by the battery inverter to recharge the battery. In order to increase the availability of the grid and reduce the battery capacity, the Sunny Island can use and control external energy sources (e.g. a generator) as an energy reserve. The Sunny Island supplies the loads with active power and reactive power. The battery system must be a TN or TT system. The Sunny Island does not support IT systems. Block diagram: The product with serial number (1261008258) was tested on: Software version: 2.55 All tests were performed on EUT SI 8.0H-11. Tests of the EUT SI 8.0H-11 not applicable for the model SI 6.0H- 11 were performed on the concerned model(s) and a statement is given at the relevant test. Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 6 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Connection logic of the SI8.0H/SI6.0H Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 7 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 8 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 9 of 15 Report No.: 13TH0287-AS/NZS 4777_0 Default interface protection settings according AS/NZS 4777.3-2005: arameter Max. clearance time Trip setting Over voltage 2s 230V +17% (270V) Under voltage 2s 230V -87% (200V) Over frequency 2s 50Hz +10% (55,0Hz) Under frequency 2s 50Hz -10% (45,0Hz) Reconnection time ermanent DC-injection Loss of main >=60s 0,5% of rated inverter output current Inverter shall detect and disconnect within 2s The stated currents and voltages are true r.m.s. -values. The voltages in this table are - phase-to-neutral in 230 V single phase systems and 230/400 V systems, - phase-to-phase in a multiphase 230 V system. Tolerances on trip values: - Voltage: +/- 5V of the set voltage value; - Frequency: +/- 0,1Hz of the set frequency value - Clearance time: less or equal clearance limit Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 10 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.2 2005 Clause Requirement Test Result - Remark Verdict 4 INVERTER REQUIREMENTS 4.1 General The inverter shall comply with the appropriate electrical safety requirements of AS/NZS 3100. NOTE: AS/NZS 3100 allows that if an individual Standard dealing with specific features of the design, construction and testing of any particular class or type of equipment is issued, it supersedes the general requirements of AS/NZS 3100 that are specifically dealt with in that individual Standard. 4.2 Compatibility with electrical installation The inverter shall have a.c voltage and frequency ratings compatible with AS 60038. NOTE: The nominal voltage at the point of supply is 230 V a.c. single phase line-to-neutral and 400 V a.c. three phase line-to-line with a tolerance of +10% -6% and a frequency of 50 Hz. 4.3 ower flow direction ower flow between the energy source and the grid may be in either direction. 4.4 (A1) ower factor The power factor of the inverter, considered as a load from the perspective of the grid, shall be in the range from 0.8 leading to 0.95 lagging for all output from 20% to 100% of rated output. These limits shall not apply if the inverter is approved by the relevant electricity distributor to control power factor outside this range for the purpose of providing voltage support. Compliance shall be determined by type testing in accordance with the power factor test described in Appendix A. NOTE: Lagging power factor is defined to be when reactive power flows from the grid to the inverter; that is, when the inverter acts as an inductive load from the perspective of the grid. 4.5 (B1) Harmonic currents The harmonic currents of the inverter shall not exceed the limits specified in Tables 1 and 2 and the total harmonic distortion (THD) (to the 50th harmonic) shall be less than 5%. Compliance shall be determined by type testing in accordance with the harmonic current limit test specified in Appendix B. NOTE: The inverter should not significantly radiate or sink frequencies used for ripple control by the local electrical distributor. The distributor should be consulted to determine which frequencies are used. 4.6 Voltage fluctuations and flicker The inverter shall conform to the voltage fluctuation and flicker limits as per AS/NZS 61000.3.3 for equipment rated less than or equal to 16 A per phase and AS/NZS 61000.3.5 for equipment rated greater than 16 A per phase. An applicable test report according to AS/NZS 3100 must be provided by the manufacturer. The inverter has voltage and frequency ratings compatible with AS 60038 (230V AC, 50Hz) In either direction See test report 4.4 See test report 4.5 See test report 4.6. Covered by EMC Report. Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 11 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.2 2005 Clause Requirement Test Result - Remark Verdict Compliance shall be determined by type testing in accordance with the appropriate Standard. 4.7 Impulse protection The inverter shall withstand a standard lightning impulse of 0.5 J, 5 kv with a 1.2/50 waveform. Compliance shall be determined by type testing in accordance with the impulse voltage withstand test of IEC 60255-5. 4.8 Transient voltage limits When type tested in accordance with the transient voltage limit test described in Appendix C, the voltage-duration curve derived from measurements taken at the a.c. terminals of the inverter shall not exceed the limits. 4.9 Direct current injection In the case of a single-phase inverter, the d.c. output current of the inverter at the a.c. terminals shall not exceed 0.5% of its rated output current or 5 ma, whichever is the greater. In the case of a three-phase inverter, the d.c. output current of the inverter at the a.c. terminals, measured between any two phases or between any phase and neutral, shall not exceed 0.5% of its rated per-phase output current or 5 ma, whichever is the greater. If the inverter does not incorporate a mains frequency isolating transformer, it shall be type tested to ensure the d.c. output current at the a.c. terminals of the inverter is below the above limits at all power levels. 4.10 Data logging and communication devices Any electronic data logging or communications equipment incorporated in the inverter should comply with the appropriate requirements of AS/NZS 60950.1. articular attention is drawn to requirements for electrical insulation and creepage and clearance distances. See Test report 4.7 See Test report 4.8 See Test report 4.9 An applicable test report according to IEC60950 or an equivalent report must be provided. The provided internal devices in the inverter were tested according the AS3100 requirements 4.1.3 Creepage distances and clearance distances for applicances and 8.4 High voltage (electrical strength). Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 12 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.3 2005 Clause Requirement Test Result - Remark Verdict 4 GENERAL AND SAFETY REQUIREMENTS 4.1 General Grid protection of the inverter energy system shall be provided by a grid protection device. This does not preclude the grid protection device being integral to the inverter, nor a single grid protection device being used to protect an inverter energy system comprising multiple inverters. Compliance with this Standard shall be determined by type testing the grid protection device on its own and, if necessary, in combination with an inverter. Compliance of this combination shall be conditional on their being used together in the same manner in which they have been type tested. Compliance of one combination of inverter and grid protection device does not preclude compliance of either device as part of a different combination. 4.2 Electrical Safety The grid protection device shall comply with appropriate electrical safety requirements of AS/NZS 3100. NOTE: AS/NZS 3100 allows that if an individual Standard dealing with specific features of the design, construction and testing of any particular class or type of equipment is issued, it shall supersede the general requirements of AS/NZS 3100 that are specifically dealt with in that individual Standard. 4.3 Connection to Low-Voltage distribution network The grid protection device shall be compatible with the low-voltage distribution network. NOTE: The nominal voltage is 230 V a.c. single phase lineto-neutral and 400 V a.c. three phase line-to-line with a tolerance of +10% -6% at a frequency of 50 Hz. 4.4 Voltage flicker The grid protection device shall conform to the voltage flicker limits specified in AS/NZS 61000.3.3 for equipment rated less than or equal to 16 A (a.c. current) or AS/NZS 61000.3.5 for equipment rated at greater than 16A (a.c. current). Compliance shall be determined by type testing in accordance with the appropriate Standard. 4.5 Impulse protection The grid protection device shall withstand a standard lightning impulse of 0.5 J, 5 kv with a 1.2/50 waveform. Compliance shall be determined by type testing in accordance with the impulse voltage withstand test of IEC 60255-5. 4.6 Data logging and communication devices Any electronic data logging or communications equipment incorporated in the inverter should comply with the appropriate requirements of AS/NZS 60950.1. articular attention is drawn to The automatic disconnection device is integral part of the inverter. An applicable test report according to AS/NZS 3100 must be provided by the manufacturer. The inverter has voltage and frequency in accordance with AS 60038 (230V AC, 50Hz) See appended table 4.6 See enclosed EMC Report See Test report 4.7 An applicable test report according to IEC60950 or an equivalent report must be provided. Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 13 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.3 2005 Clause Requirement Test Result - Remark Verdict requirements for electrical insulation and creepage and clearance distances. The provided internal devices were tested according the AS3100 requirements 4.1.3 Creepage distances and clearance distances for applicances and 8.4 High voltage (electrical strength). 5. GRID ROTECTION REQUIREMENTS 5.1 General The grid protection device shall operate (a) if supply from the grid is disrupted; or (b) when the grid goes outside preset parameters (e.g. under/over voltage, under/over frequency); or (c) to prevent islanding. Specific requirements are contained in Clauses 5.2 to 5.5. 5.2 Disconnect device The grid protection device shall incorporate a disconnection device which shall prevent power (both a.c. and d.c.) from the inverter energy system entering the grid when the disconnection device operates. NOTE: The disconnection device need not disconnect sensing circuits. The disconnection device shall incorporate an electromechanical switch if (a) there is no galvanic isolation between the energy source(s) and the grid; or (b) the inverter system continues to provide electrical power to any portion of the electrical installation (i.e. it operates as an uninterruptible power supply (US) system) in the event of the disruption of the grid supply. NOTES: 1 Galvanic isolation can be achieved by using either a two winding high-frequency transformer or a two winding mains frequency transformer. 2 Galvanic isolation is not required on sensing circuits. Any disconnection device intended for use with a US system shall only break the active conductor(s). The disconnection device may incorporate semiconductor devices if galvanic isolation exists between the energy source(s) and the grid and the system does not operate as an uninterruptible power supply system. 5.3 Voltage and frequency limits (passive anti islanding protection) The grid protection device shall incorporate passive anti-island protection in the form of under- and over-voltage and under- and over- The device includes an automatic disconnecting facility for renewable power generator installations (under/ over voltage/ under/ over frequency and anti islanding), see test Report The unit provides galvanic separation. The unit is switched off redundant by the high power bridge of the inverter and the relays in line and neutral. See enclosed report 5.3 Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 14 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.3 2005 Clause Requirement Test Result - Remark Verdict frequency protection. If the voltage goes outside the range V min to V max or its frequency goes outside the range f min to f max, the disconnection device (see Clause 5.2) shall operate within 2 s, where (a) V min shall lie in the range 200-230 V for a single-phase system or 350-400 V for a threephase system; (b) V max shall lie in the range 230-270 V for a single-phase system or 400-470 V for a threephase system; (c) f min shall lie in the range 45-50 Hz; and (d) f max shall lie in the range 50-55 Hz. The limits V max, V min, f max and f min may be either preset or programmable. The values V max, V min, f max and f min may be negotiated with the relevant electricity distributor. The settings of the grid protection device shall not exceed the capability of the inverter. 5.4 Limits for sustained operation The introduction of limits for sustained operation is under consideration. NOTE: See Appendix A for further information about the proposal. 5.5 Active anti islanding protection The grid protection device shall incorporate at least one method of active anti-islanding protection. Examples of such methods include shifting the frequency of the inverter away from nominal conditions in the absence of a reference frequency (frequency shift), allowing the frequency of the inverter to be inherently unstable in the absence of a reference frequency (frequency instability), periodically varying the output power of the inverter (power variation) and monitoring for sudden changes in the impedance of the grid by periodically injecting a current pulse (current injection). NOTE: Active anti-islanding protection is required in addition to the passive anti-islanding protection described in Clause 5.3 above to prevent the situation where islanding may occur because multiple inverters provide a frequency and voltage reference for one another. The active anti-islanding protection system shall operate the disconnection device (see Clause 5.2) within 2 s of disruption to the power supply from the grid. 5.6 Reconnection procedure Only after all the following conditions have been met shall the disconnection device operate to reconnect the inverter to the electricity distribution network (a) the voltage of the electricity distribution network has been maintained within the range Informative See enclosed report 5.5 The unit provides monitoring of the voltage, frequency and synchronisation. If one of these conditions is not met, then the unit is not switching on. Copyright Bureau Veritas Consumer roducts Services Germany GmbH

age 15 of 15 Report No.: 13TH0287-AS/NZS 4777_0 AS/NZS 4777.3 2005 Clause Requirement Test Result - Remark Verdict V min V max for at least 1 m, where V min and V max are as defined in Clause 5.3; and (b) the frequency of the electricity distribution network has been maintained within the range f min f max for at least 1 m, where f min and f max are as defined in Clause 5.3; and (c) the inverter energy system and the electricity distribution network are synchronized and inphase with each other. 5.7 Security of protection settings The internal settings of the grid protection device shall be secured against inadvertent or unauthorized tampering. Changes to the internal settings shall require use of a tool and special instructions not provided to unauthorized personnel. NOTE: Special interface devices and passwords are regarded as tools. 5.8 Compliance with grid protection requirements Compliance with the anti-islanding protection requirements shall be determined by type testing in accordance with the anti-islanding protection tests described in Appendix B. Settings only available with password for the service personal. Appendix B4 noticed Copyright Bureau Veritas Consumer roducts Services Germany GmbH