T100 Vector Impedance Analyzer. timestechnology.com.hk. User Manual Ver. 1.1

Similar documents
PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

BRAKE TESTER DECELEROMETER

Issue 2.0 December EPAS Midi User Manual EPAS35

Cannondale Diagnostic Tool Manual

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Motor Tuning Instructions

Instruction of connection and programming of the VECTOR controller

MoistureMatch A next generation grain tester

EPAS Desktop Pro Software User Manual

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

RESISTIVE LOAD XP300C

QUICK START GUIDE 199R10546

CENTOR TORQUE GAUGE - EASY VERSION INSTRUCTION MANUAL. Version 1.3

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

DA-ST512 (Suspension Calibration Application) User s Manual

When you finish the running, power off the receiver BEFORE turning off the transmitter.

Model 212A Smart SerialPRO Interface User s Guide

Touch plate serial number. Please save this info here for use later:

Allows 2 relays to be activated. based on RPM and throttle. This guide will give you a general overview to the use of the HUB

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

Grain Moisture Meter. Operators manual

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

MATRIX LLC LEVEL CONTROL PANEL

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

EV Display V4 User Guide

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

Package Contents: Transferring Data to a PC

medusa research Inc. Engineered Products for the RC Enthusiast

Rotel RSX-1067 RS232 HEX Protocol

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

GuardMagic DLLS-DLLE programming tool manual v

V 2.0. Version 9 PC. Setup Guide. Revised:

or, with the time and date option enabled using the CommFlags command:

Generator Sets Controller 210. Operation Manual. Ver1.0

ROW PRO DOWN PRESSURE

Educational Robot. Revision 2.0

Rotel RSX-1065 RS232 HEX Protocol

PROGRAMMING MANUAL ZeelProg PDCI-20V

OVERVIEW OF CONTROLS

Scout II Operation Instructions

Sensormedics Vmax with ECG Tango M2 Interface Notes

Table of Contents. General Information...1. Components...2. Connection...4

TEST REPORT. Test Report for Mating Cycle Validation of Mini Circuits QBL Series Quick-Lock Test Cables.

Serial adapter 1.0 V10 Fadec to serial comunications

EZECU - EzFi Starter ECU Standalone 3D Programmable Fuel Injection Computer for BOSCH Compliant EFI Systems

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

ZT-USB Series User Manual

DIGITAL TORQUE GAUGE MODEL BTGE-G

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

Interactive Whiteboard. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual

Pistonphone Type 42AP

Pendulum control & isolation valve with RS485 interface with valve cluster functionality

INDEX. 1.Safety Precautions and Warnings...3

An ISO 9001:2008 Registered Company

CENTOR TORQUE GAUGE - STAR VERSION INSTRUCTION MANUAL. Version 1.3

Rotel RSX-1055 RS232 HEX Protocol

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

SC-30KAM / SC-60KAM / SC-150KAM / SC-60KAL / SC-150KAL SE-30KAM / SE-60KAM / SE-150KAM / SE-60KAL / SE-150KAL 1WMPD

Harris IRT Enterprises Digital Resistance Tester Model XP

SUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL

Features: Enhanced throttle response, excellent acceleration, linearity and driveability

Getting Started HONDA

GloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II

Technician Reference Manual. Digital Diagnostic Terminal Software Version 1.3. SmartCraft Systems. Printed in U.S.A.

StepSERVO Tuning Guide

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

INTECH Micro 2300-RTD6

Injection System. Description of the injection system calibration software COMPLETE VERSION

Model ½ Digit Multimeter

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor.

APPLICATION NOTE. ATAK51003-V1 Quick Start Guide. Atmel ATAN0033. Kit Contents

CAN-Translator. User s guide

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

USER MANUAL LVC-200TC DIGITAL THERMOCOUPLE VACUUM GAUGE

C10325 v1.1. Thanks for your purchasing the intelligent and powerful charger.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

SmartPak Welding Controller WK-MPS-16 Constant Current

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com NEAR FIELD PROBE SET BROADBAND RESPONSE

Norcal Power/SWR Meter Assembly & Operating Manual. Revision 1D 10/15/2008

CITIZEN. series. Precision Balances

EDG6000 Electronic Digital Governor

***Before starting : view the Virtual tour located at c:/programs/msoffice/powerpointviewer And carry out the tutorials in the manuals supplied***

MICROPROCESSOR BASED CONTROLLER

Subaru L Turbo

SP5 INSTALLATION AND SETUP MANUAL

High-Dynamic-Range Power Sensors Models 2101 & 2103

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

Review: The West Mountain Radio CBA-IV Battery Analyzer Phil Salas AD5X. Figure 1: West Mountain Radio CBA-IV Battery Analyzer

2 Dynamics Track User s Guide: 06/10/2014

Precision Balances WEIGHING WITH EXPERIENCE

6.7 FLS Info - Eco FLS Wet calibration and tethering check FLS connection to the FM device FLS interface cable socket

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

Transcription:

T100 Vector Impedance Analyzer timestechnology.com.hk User Manual Ver. 1.1

T100 is a state of the art portable Vector Impedance Analyzer. This powerful yet handy instrument is specifically designed for the advanced amateur radio experimenters working at the VHF/UHF band. TABLE OF CONTENTS General Description T100 Menu Structure Key Definitions Single Frequency Sweep Frequency Plot Calibration Settings PC Mode Firmware Update Specifications Accessories GENERAL DESCRIPTION The T100 Vector Impedance Analyzer is essentially a device to inject an RF signal into whatever is connected to its test port, and measures the amplitude and phase of the reflected RF signal. The reflected amplitude and phase are calibrated with industrial standard 3-term Open/Short/Load (OSL) calibration method. T100 Vector Impedance Analyzer can operate from 100MHz to 170MHz (VHF), and from 400MHz to 470MHz (UHF), with a 25KHz minimum step size.

T100 MENU STRUCTURE MAIN MENU SINGLE FREQ SWR IMPEDANCE (SERIAL) IMPEDANCE (PARALLEL) S11 (RECTANGULAR & POLAR) SWEEP FREQ PLOT SWR IMPEDANCE (Z) RESISTANCE (R) REACTANCE (X) RETURN LOSS (S11) PHASE ANGLE CALIBRATE CONNECT OPEN CONNECT SHORT CONNECT LOAD SETTINGS BACKLIGHT AUTO ON OFF AUTO POWER OFF ENABLE DISABLE BATTERY ALKALINE NIMH CAL DATA PROTECT LOCK CAL DATA UNLOCK CAL DATA INFO PC MODE

KEY DEFINITIONS POWER : Press and hold this key for two seconds to turn on or off T100 Vector Impedance Analyzer. CONFIRM : Use this key to confirm the desired selections and frequencies entered. MODE : In SINGLE FREQ, this key is used to switch between the following modes cyclically: SWR IMPEDANCE (SERIAL) IMPEDANCE (PARALLEL) S11 In SWEEP FREQ PLOTS, this key is used to switch between the following functions cyclically: FREQUENCY Y SCALE ALIGNMENT STEP SIZE

ARROWS : These keys are used to select the desired menu items or options. They are also used to increase/decrease the frequency. Hold to increase/decrease frequency automatically. In SINGLE FREQ, the step size is fixed at 25KHz. In SWEEP FREQ PLOT, the current step size can be selected with the MODE key. 0 ~ 9 NUMERIC : Use these keys to enter the desired frequency directly. Frequencies within the valid operating range will automatically be aligned to the 25KHz steps. Frequencies outside the valid operating range will be ignored. BACK : Cancel the current operation and/or go back to the previous menu.

SINGLE FREQ In this mode, T100 can display the measured data in any of the following four representations. You may switch cyclically through these representations with the MODE key. SWR IMPEDANCE (SERIAL) IMPEDANCE (PARALLEL) S11 (RECTANGULAR & POLAR) SWR displays the Standing Wave Ratio in large font for easy reading. It also displays the impedance (Z) for reference. SWR FREQ:435025 Z=138.08 IMPEDANCE (SERIAL) displays the impedance seen from the test port. The impedance is resolved into the real (resistive) part and imaginary (reactive) part connected in series. The corresponding inductance or capacitance is also displayed according to the sign of the reactance. IMPEDANCE FREQ:435025 101.80 - j112.58 SERIAL 3.25pF

IMPEDANCE (PARALLEL) displays the impedance seen from the test port. The impedance is resolved into the real (resistive) part and imaginary (reactive) part connected in parallel. The corresponding inductance or capacitance is also displayed according to the sign of the reactance. IMPEDANCE FREQ:435025 240.10 - j194.53 PARALLEL 1.88pF S11 displays the rectangular and polar representations of the S11 measured. S11 FREQ:435025 RECTANGULAR: 0.58 + j0.34 POLAR: 0.67 <-30.10

SWEEP FREQ PLOT Under this menu, T100 can plot any of the following measured data over the desired frequency range: SWR IMPEDANCE (Z) RESISTANCE (R) REACTANCE (X) RETURN LOSS (S11) PHASE ANGLE Use the MODE key to switch cyclically between any of the following parameters to change their value. FREQUENCY - use the ARROW keys to increment or decrement the frequency by the value of STEP SIZE. The cursor on the plot will move accordingly. The frequency can also be entered directly using the numeric keys. Y SCALE - use the ARROW keys to select the maximum value on the Y axis. Possible values are 3, 10, 30, 100, 300, and 1000. ALIGNMENT - use the ARROW keys to select if the directly entered frequency should be aligned to the CURRENT position of the cursor, BEGIN (leftmost on the plot), CENTER (of the plot), or END (rightmost of the plot). Ranges outside the valid frequencies will be shaded. STEP SIZE - use the ARROW keys to select the desired frequency step size. Possible values are 25KHz, 100KHz, 500KHz,and 1MHz.

CALIBRATION T100 Vector Impedance Analyzer employs industrial standard Open/Short/Load (OSL) calibration method to eliminate various system errors. To perform accurate measurements, T100 needs to be calibrated against the OPEN, SHORT, and LOAD standards. Three high quality OPEN, SHORT, and LOAD SMA terminators are included for this purpose. Resulting calibration data to be used in computations will be stored in non-volatile memory in T100. Calibration data is locked upon power up of T100 to avoid accidental erasure. It has to be unlocked in the SETTINGS menu, before CALIBRATION can be performed. CALIBRATE DATA LOCKED GOTO SETTINGS MENU TO UNLOCK DATA FIRST Connect securely the OPEN standard, and then press the OK key to start calibration. Likewise for the SHORT and LOAD standards in sequence to complete the calibration. Calibration data will be locked again automatically after calibration. The instrument is now ready to use. If desired, T100 can be re-calibrated at any time. CALIBRATE CONNECT OPEN CALIBRATE CALIBRATION DONE

SETTINGS A number of general options and information are available in this menu. SETTING MENU BACKLIGHT AUTO POWER OFF BATTERY CAL DATA PROTECT INFO BACKLIGHT AU TO - Turn off backlight automatically if no key is pressed for 30 seconds. ON - Leave backlight always on OF F - Leave backlight always off BACKLIGHT MENU AUTO ON OFF AUTO POWER OFF EN ABLE - Automatic power off if no key is pressed for 5 minutes. DI SABLE - No automatic power off. AUTO POWER OFF MENU ENABLE DISABLE

BATTERY Choose between ALKALINE and NIMH to reflect the type of batteries being used. It only affects the threshold voltage dictating when a low battery sign on the upper right hand corner of the display will appear. CAL DATA PROTECT Select UNLOCK CAL DATA before calibration. Calibration data will be locked automatically after calibration. Alternatively, choose LOCK CAL DATA to lock calibration data manually if necessary. INFO Display general information of the device, as well as the battery voltage. ( 5 blocks on the battery bar as battery full and 1 block as battery empty.) BATTERY MENU ALKALINE DISABLE PROTECT MENU LOCK CAL DATA UNLOCK CAL DATA SYSTEM INFORMATION MODEL : T100 H/W VER: 1.00 F/W/VER: 1.00 BATTERY:

PC MODE T100 is capable of communicating with a PC via an emulated serial link over the USB connection. Virtual serial port driver for Windows XP is included in the T100 CD-ROM and should be installed before connecting your T100 to a PC. A sample host program for Windows XP is also included to demonstrate controlling T100 from a PC, and displaying T100 measured data. The (virtual) serial communication between T100 and the PC should be configured as follows: Baud Rate = 38400 baud Parity Bit = None Data Bits = 8 Stop Bit = 1 On entering the PC MODE, T100 will display the WAITING FOR HOST CMD message and listen to the serial port. PC MODE WAITING FOR HOST CMD

To command T100 to tune to a specific frequency, the host program shall transmit a six-digit frequency in ASCII characters via the serial port. To command T100 to take a measurement, send an ASCII character S. Then receive from the serial port a null terminated ASCII string. This is the measured magnitude and argument in degrees, separated by a comma. The same result will be displayed on T100 at the same time. Send another S to repeat measurement at the same frequency, or issue another six digit frequency to tune to a new frequency. Sending an ASCII character D will bring T100 back to the initial state, displaying the WAITING FOR HOST CMD message and listen to the serial port. PC MODE FREQ : 144000 S11 <S11 0.9577-14.72

FIRMWARE UPDATE T100 firmware can be updated as new releases are available. Updated firmware file can be downloaded from the Internet to a PC and programmed to the T100 via the USB interface. Caution 1. Please use fresh batteries when updating firmware. 2. Do not turn power off or remove batteries during firmware updating. Firmware Update Hold down the Mode key while switching on T100 to enter the Firmware Update Mode. T100 will show the screen on the left. On a PC running Windows XP operating system, open a DOS console in a directory with the two files update.exe and firmware.enc. Plug in the USB cable to connect the PC and T100. Find out which USB emulated COM port T100 is connected to from the Control Panel/ System/Hardware/Device Manager on the PC. With T100 at Firmware Update mode, issue the following command in the DOS console to update the firmware with the file firmware.enc : update firmware.enc -COMx -38400

T100 SPECIFICATIONS Frequency Range: 100MHz ~ 170MHz (VHF) 400MHz ~ 470MHz (UHF) PLL Synthesized Frequency Resolution : 25KHz Test Port Connector : SMA Output Power : > 0dBm (typical) Harmonics : < -30dB (minimum) Display : 128 x 64 dots graphical LCD with backlight Physical Dimensions : 140mm(length) x 68mm(width) x 25mm(thick) Net Weight : 130 gram (without batteries) Power : AA Size Battery x 2 ACCESSORIES SMA connector for OPEN Calibration: P/N 202112 SMA connector for SHORT Calibration:P/N 132331 SMA connector for LOAD Calibration: P/N 132360 SMA male to BNC female adaptor SMA male to SO-239 adaptor USB A to mini-b cable CD-ROM