EV RANGE MULTI-SPEED GLANDLESS CIRCULATORS

Similar documents
SimFlex A. w w w. s m e d e g a a r d. c o m. Pumping Technology

VERTICAL MULTISTAGE PUMPS HIL AND HILFLEX SEE OUR FLEXDRIVE LEAFLET FOR DRIVE DETAILS. reliable efficient quality. Pumping Technology

3 Specification Magneta Smedegaard

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

ETHERMA 4-SPEED CIRCULATOR PUMPS

LK Manifold Shunt VS2

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

4 Specification Magneta Smedegaard twin pumps

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Pump Stations for Heating Circuits

Japanese Technology since Ego Circulators. Databook

Grundfos Home Booster

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

TP /2-A-F-A-BAQE 400D 50HZ

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

AQUAVAR AQUAVAR VARIABLE SPEED SYSTEM CONTROLLER. Applications. Specifications. Benefits of using Aquavar

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

TPE 25-80/2-A-O-A-BUBE 1X230 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

TPED /4-A-F-A-BQQE 3X400 50HZ

Data sheet: Wilo-Stratos PICO 25/1-6

CRE20-08 A-F-A-E-HQQE 3x HZ

TP /2-A-F-A-BQQE 400D 50HZ

CM5-5 A-R-A-E-AVBE C-A-A-N

Data sheet: Wilo-Stratos PICO 25/

Contents. Identification

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

Elite. KSB Australia Pty Ltd. Centrifugal Pump

TPED /4-S-A-F-A-BAQE 3X400 50HZ

Lowara Ecocirc Vario (EV)

CRE15-01 A-F-A-E-HQQE 1x HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CIRCULATION PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS VORTEX HEATING PUMPS

NBE50-250/205 A-F2-A-BAQE

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CRE A-F-A-E-HQQE 3x HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

TPE N-A-F-I-BUBE

NB /263 AS-F2-A-BAQE

TP /2-A-F-A-BUBE 1X230 50HZ

LK Manifold Shunt VS 2-2,5

CR15-14 A-F-A-E-HQQE 3x400/ HZ

Ajax ISO. Centrifugal Pump ISO Application Application. Designation Designation. Operating Data - 50 Hz. Design. Type Series Booklet

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

TP /2-A-F-A-BQQE 400D 50HZ

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

VERTICAL IN-LINE PUMP

SCX-DCX SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air conditioning Light commercial range 2 Pole - 50 Hz 230 V OPERATING LIMITS

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

IN-LINE NORMALIZED ELECTROPUMPS in cast iron

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

Position Qty. Description Single Price 1 SEV B

CR45-3 A-F-A-E-HQQE 3x400/ HZ

NB80-160/161 A-F2-A-BQQE

CR120-2 A-F-A-E-HQQE 3x400/ HZ

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

NB /438 A-F1-A-GQQE

TP /4-A-F-A-BQQE 400Y 50HZ

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

SIE BV/ED EVS. SINGLE HEAD PUMPS IN-LINE ELECTRONIC CONTROL Heating - Air conditioning S.H.W. 50 et 60 Hz. operating limits SIE BV/ED

CM5-6 A-R-A-E-AQQE C-A-A-N

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

CM10-3 A-R-A-E-AVBE F-A-A-N

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

CRE10-02 A-A-A-E-HQQE 1x HZ

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

CM5-5 A-R-A-E-AVBE F-A-A-N

CR A-F-A-E-HQQE 3x400/ HZ

GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D. In-line circulator pumps. 50 Hz. Lenntech

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

TPE /4-A-F-A-BAQE 3X400 50HZ

TPE /2-S-A-F-A-BAQE 3X400 50HZ

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

CRNE AN-F-G-E-HQQE 3x HZ

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Transcription:

EV RAGE MULTI-SPEED GLADLESS CIRCULATORS Unique 1-2- Modular Pump Construction or 4 Speed Electrical Regulator Most Models have Built-In Thermal Overload Protection Single and Three Phase Motors H.W.S Bronze Pumps 1400 and 2800 R.P.M Pumps Flanges, up to 5mm, Double Drilled Pn/ Single-Case Twin Pumps A KSB Company

EV Range Multi-Speed Glandless Circulators area can be minimised. ormal raw water contains a certain amount of lime which will precipitate out as the temperature increases (max. recommended HWS water temp. 5 C). Smedegaard s patented answer to this problem is to fit a TUT pressure equalising seal, manufactured in brass and stainless steel, to all HWS V and VZ secondary glandless pumps. This seal reduces the number of water changes in the rotor chamber and hence the amount of lime deposited. Construction EV circulators are designed with the unique 1-2- modular pump construction.the pump consists of three assemblies, the pump casing, the rotating element and the stator. This together with the high efficiency of the motor and the use of recycleable materials, means that great attention has been paid to enviromental issues. An advanced lubrication system, which gives efficient cooling of the motor, together with a hardened stainless steel shaft, substantial carbon bearings and a one-piece can arrangement, all accurately machined ensures very quiet operation and longer life. Energy saving can be achieved by adjusting the speed of the motor to suit the system. The motor and pump casing are designed for maximum efficiency and, in addition, the EV circulator can be adjusted, using the speed selection switch, to or 4 pump curves. This ensures total flexibility and is the only adjustment needed to secure maximum energy saving and minimum noise level. Commercial EV circulators are 4-speed and domestic EV circulators are 1 and speed. Application Dark blue pumps for heating water. Yellow pumps for secondary hot water applications. Temperature range up to +1 C. In secondary hot water applications it is recommended that water temperature does not exeed 5 C, to minimise lime deposit. Maximum content of Glycol 50%. Maximum working pressure Bar maximum impurities 5mg/dm. TUT anti-lime system in HWS pumps The life of a secondary hot water circulating pump can be extended if the limescale build-up in its rotor bearing Pump medium Clean, non-viscous, non-aggressive, non-explosive fluids without any solids or fibres. Antifreeze without any mineral oil. If any liquid other than water is being pumped, we recommend that you contact Smedegaard or their representatives as the pump characteristics may change. Special models available upon request. Materials of construction Pump: Cast iron or bronze Impeller: Cast iron/polysulphone/bronze Shaft: Stainless steel Can: Stainless steel Bearings: Carbon O Rings: EPDM rubber Model identification EV Glandless Range 5 Connection size 50mm (2") 125 ominal impeller dia. in mm 4 Motor 4-pole (1400 rpm) 2 Motor 2-pole (2800 rpm) C Dark blue-heating CD Dark blue single-case twin pump Z Yellow bronze pump for H.W.S. See availability of models on the individual curves and in the tables. Impeller The Impellers are balanced to ensure a long bearing life and quiet operation. Motor Motors of glandless construction, with class F insulation, designed and produced by Smedegaard, are used with these pumps to ensure quiet operation and long life. Standard voltages are 1x20V, x20v, x400v, +%, -%, 50HZ (IEC 8). IP 42 for -speed motors and IP 44 for 4-speed motors.for some duties it may be possible to select a pump with either a 1400 rpm or 2800 rpm motor. The 2800 rpm pump is smaller, lighter and less expensive than a 4-pole pump. However 2

in high flow, low head shunt applications, ultra sensitive noise areas or where static head is limited, a 1400 rpm. pump is often advantageous. Static head Minimum static head required to avoid cavitational problems. 1400 rpm pumps, 2 m at 82 C, 4 m at 95 C. 2800 rpm pumps up to 5-88-2, 2.5 m at 82 C, 5 m at 95 C. From 5-95-2, m at 82 C, m at 95 C Airborne sound pressure levels Model EV 2-40-2 to EV 5-88-2, max 4 db(a) Model EV 5-95-2 to EV 12-15-4, max 55 db(a) Accesories and Alternatives Self regulating SimFlex circulators and automatic controls for EV. For the EV circulators, starters, changeover panels, night setback controls and remote controls are available. As an alternative to EV, the SimFlex range is available. These pumps feature manually adjustable fixed or variable speed settings to enable them to be adjusted to suit the system. This ensures a great energy saving and helps to eliminate system noise. See back page and separate brochures. Twin Pumps Most of the EV range can be supplied as single-case twins, these are designated CD. Two motors and an additional non-return valve are built-in the same casing and in the majority of cases the overall face to face dimensions and connections remain the same as a single pump. Y Piece Manifolds In addition to the single-case twin pumps, the SMEDEGAARD TAS TWI Y PIECES with built-in isolating and non-return valves can be supplied for use with single pumps up to 125 mm (5"). These manifolds are suitable for temperatures up to 1 C with a maximum system pressure of bar and a pump working pressure of bar. Installation The pump should always be installed with the pump shaft horizontal and the motor terminal box must not be mounted in a downward position. The motor of the pump must not be insulated and it is very important that the drain holes in the motor flange are unobstructed. Direction of flow through the pump casing is indicated by an arrow. It is recommended that the pump is mounted in vertical pipework, pumping upwards. For heating circulation pumps pumping vertically downwards the system must be free of air and the pump should be run at full speed. HWS secondary pumps should never be fitted pumping downwards. If a single case twin pump is fitted in horizontal pipework an automatic air vent should be fitted in the plug provided on the side of pump casing. For further details see Smedegaard s installation guide for EV glandless range. Electrical connection and motor protection, the pumps should be wired in accordance with existing regulations. Motor protection may not be required on EV2/-40/ 70-2 pumps. The larger pumps need overload protection. When wired through a Smedegaard 12 starter, overload protection is automatically achieved immaterial of speed selected, using terminals a and b in the terminal box. For availability, see individual curves. If a standard motor starter is used, amp ratings/speed settings are shown on the individual pump curves and on the pump nameplates. Twin pump auto changeover panels are available upon request. Approvals and standards The EV pumps range is CE marked and approved according to E 0-5-2-51. The hydraulic performance curves are published according to E 11/E 2990 grade 2.

EV -1-2 (D) m 40 80 1 0 00 lgpm ft kpa EV PUMPS 2 pole 2800 R.P.M. 50 0 9 EV 5-95-2 (D) EV 5-1-2C EV 8-1-2 (D) 0 90 EV 2/-72-2 (D ) EV -0-2 (D) EV 4-95-2 (D ) EV 5-88-2 (D ) EV 8-0-2 (D) 0 EV 2-70-2/EV -70-2 (D ) EV 4-75-2 (D ) EV -95-2 (D ) EV 8-95-2 (D) EV 2-5-2/EV -5-2 (D) EV 4-0-2 (D) 0 1,5 MIIWATT 2-50-2 5 1 0, 1 1,5 9 0 0 90 0,5 1 2 4 8 1 2 0 m/h l/sec. m 40 80 1 0 00 lgpm ft kpa EV PUMPS 4 pole 1400 R.P.M.. EV -2-4 (D) 50 0 9 EV 8-0-4 (D) 0 90 EV 5-10-4 (D) EV -10-4 (D) EV 8-10-4 (D) 0 EV -125-4 (D) EV 8-125-4 (D) EV 4-125-4 EV -10-4 0 EV 5-125-4 (D) EV -10-4 EV 8-92-4 EV 12-15-4 1,5 EV -92-4 EV 5-0-4 EV 4-0-4 (D)/EV-0-4 5 1 EV -15-4 0, VARIO 25 / EV 2-75-4 / EV -75-4 1 1,5 9 0 0 90 0,5 1 2 4 8 1 2 0 m/h l/sec. 4

Dimensions in mm P P Weight (kg) Type A A1 B B1 C C1 D d E F G H J K L K L MiniWatt 2/-50-2 10/180* - 90-40 - - 1"-1 1 4 " - 50-1 85 80 M - -,0 - EV 2/-5-2 (D) 10/180* 180 90 75 40 40-1"-1 1 4 " 10 50 245 1 85 80 M - -,0,4 EV 2/-70-2 (D) 10/180* 180 90 75 40 40-1"-1 1 4 " 10 50 245 1 85 80 M - -,2,8 EV 2/-72-2 (D) 180 180 90 75 40 40-1"-1 1 4 " 10 50 245 145 85 - - - - 4,5 8,5 EV 2/-75-4 180-90 - 55 - - 1"-1 1 4 " - 0-0 85 - - - - 5,7 - EV -0-2 (D) 180 180 90 75 2 50-1 1 4 " 10 5 05 180 95 - - - -, 1, EV -0-4 2-5 - 4 - - 1 1 2 " - 81-170 95 1 14 125 19, - EV 4-0-4 (D) 250 250 125 90 75 75 0 40 0 5 50 10 95 0 14 1 19 11,7,2 EV 4-125-4 250-125 - 75-0 40-95 - 5 0 0 14 1 19 11,7 - EV 4-0-2 (D) 250 250 125 90 75 75 0 40 0 75 50 10 90 0 14 1 19,0 18,2 EV 4-75-2 (D) 250 250 125 90 75 75 0 40 0 75 50 15 95 0 14 1 19 11, 19,0 EV 4-95-2 (D) 250 250 125 90 75 75 0 40 0 75 50 0 5 0 14 1 19 14,2 25 EV 5-0-4 00-0 - 8-15 50-75 - 5 90 1 14 125 19 14,4 - EV 5-1-2 280-140 - 8-15 50-5 - 280 125 1 14 125 19 14,4 - EV 5-125-4 (D) 280 280 140 1 8 8 15 50 0 85 90 0 5 1 14 125 19 17, EV 5-10-4 (D) 40 40 170 145 85 85 15 50 250 5 480 250 125 1 14 125 19 8 7,5 EV 5-88-2 (D) 280 280 140 1 8 8 15 50 0 85 90 0 5 1 14 125 19 17,5 29,5 EV 5-95-2 (D) 280 280 140 1 8 8 15 50 0 95 90 20 125 1 14 125 19 28, 52 EV -92-4 280-140 - 9-185 5-80 - 170 90 10 14 145 19,5 - EV -125-4 (D) 40 40 170 140 9 9 185 5 240 5 455 25 125 10 14 145 19 4,5 58,5 EV -15-4 00-145 - 9-185 5-5 - 225 5 10 14 145 19 5,0 - EV -95-2 (D) 40 40 170 140 9 9 185 5 240 5 455 25 125 10 14 145 19 5 0,5 EV -1-2 (D) 40 40 170 140 9 9 185 5 240 5 455 280 125 10 14 145 19 41,5 72 EV -10-4 70-190 - 9-185 5-5 - 25 125 10 14 145 19 40 - EV 8-92-4 0-170 - 0-0 80-0 - 20 0 - - 10 19 2 - EV 8-125-4 (D) 0 0 185 10 0 2 0 80 270 5 5 240 10 - - 10 19 42 72,5 EV 8-10-4 (D) 90 0 0 10 0 0 0 80 270 1 5 290 15 - - 10 19 4,5 79,8 EV 8-0-4 (D) 440 440 2 180 5 0 0 80 270 5 5 290 10 - - 10 19 72,5 12 EV 8-95-2 (D) 0 0 185 10 0 2 0 80 270 5 505 240 125 - - 10 19 42 72,5 EV 8-0-2 (D) 0 0 185 10 0 0 0 80 270 5 5 290 125 - - 10 19 49,5 85,5 EV 8-1-2 (D) 0 0 185 10 0 0 0 80 270 5 5 290 125 - - 10 19 50 84,5 EV -10-4 80-0 - 1-2 0-125 - 270 125 - - 180 19 41 - EV -10-4 (D) 470 485 20 2 10 0 2 0 78 15 740 292 0 - - 180 19 79 2 EV -2-4 (D) 485 485 250 2 0 0 2 0 78 15 740 55 0 - - 180 19 90,5 170,5 EV 12-15-4 450-225 - 0-250 125-10 - 00 10 - - 2 19 0 - simple double When both P and P are shown, the pump is supplied with flanges double drilled to facilitate interchangeability when used for replacement. ote: 80, 0 and 125 mm pump casings can be supplied drilled P to special order. (D) = Available as twin pump. (ot EV 2) 5

Speed adjustments for EV Range. Wiring details for EV range 1 Single phase DIAG. A DIAG. B Phase Phase Domestic -speed single-phase. L Thermal overload protection DIAG. C DIAG. K DIAG. D 2 Phase, L Thermal overload protection Phase, L Light commercel 4-speed single-phase Three phase DIAG. E DIAG. F Thermal overload protection DIAG. G DIAG. H Commerciel 4-speed -phase. ote: Above wiring diagrams are cross referenced on the individual pump curves. It is Smedegaard s policy to continually improve and develop its product range. We reserve the right to change specifications without prior notice. Whilst every care has been taken to ensure the data is correct, no responsibility can be taken for inaccuracies or misprints. Smedegaard Pumps Ltd T. Smedegaard A/S United Kingdom Denmark A KSB Company Tel. +44 (0)1278 458 8 Tel. +45 4 9 28 Fax +44 (0)1278 452 454 Fax +45 4 17 info@smedegaard.co.uk info@smedegaard.dk www.smedegaard.co.uk www.smedegaard.dk EV/11/