COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

Similar documents
Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Effective June 2016 New Issue

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Type NR oil switch installation and operation instructions

Effective November 2016 Supersedes February 2012 (S )

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

Factory Authorized Mechanism Enhancement (FAME)

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

Figure 1. Kearney Type HX cutout.

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

Two-way cable interlock kit for Magnum fixed circuit breakers

Two-way cable interlock kit for Magnum drawout circuit breakers

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

3-way multi-family drawout cable interlock kit - type 32 - RF

Instruction Booklet IB E. Contents

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

CCP2-FLR1-21_ flange-rod operating mechanism

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

ELB ELB

5/15/27 kv, 25/31.5/50/63 ka Manual Ground & Test Devices Installation, Operations and Maintenance Manual

Vacuum Circuit Breaker (Vehicle)

O & M Manual for the EATON Generator Ready Loadcenter

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

CM52 Network Protector with Arc Flash Reduction Module

Effective October 2016 Supersedes January 2014 (S )

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Vacuum Circuit Breakers (Vehicle)

COOPER POWER SERIES. Type VSA12, VSA12B, VSA16, VSA20, and VSA20A operation and installation instructions. Reclosers MN280063EN

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

Magnum Breaker Remote Racking Device (MRR1000)

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

IB PowlVac ITE-HK Remote Racking Device

Advanced Test Equipment Rentals ATEC (2832)

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Installation Instructions For Motor Control Center (MCC) Units

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Vacuum Circuit Breakers (Vehicle) Type HKR 7.5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9928C

S Contents. Applicable to Serial Numbers A101 and above or beginning with CP57.

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

EV-2051-M Electric Motor. Operation and Maintenance Manual

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

38 kv Type VCPW-HD Simple Electrical Ground & Test Device (SEG&TD) lower terminal instruction booklet

Transcription:

Reclosers MN280070EN Effective May 2017 Supersedes July 2014 (S280-80-23) COOPER POWER Dielectric grease application to recloser cable instructions SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. CABLE INSTRUCTIONS MN280070EN May 2017 i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY...I SAFETY FOR LIFE...III SAFETY INFORMATION...III Safety instructions...iii PRODUCT INFORMATION.... 1 Introduction...1 Acceptance and initial inspection...1 Handling and storage...1 Quality standards................................................................................1 Materials and tools required...1 INSPECTION AND CLEANING PROCEDURE.... 2 DIELECTRIC GREASE APPLICATION PROCEDURE.... 3 ii CABLE INSTRUCTIONS MN280070EN May 2017

! SAFETY FOR LIFE Safety for life Eaton s Cooper Power series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission.! SAFETY FOR LIFE The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Safety information Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.3 CABLE INSTRUCTIONS MN280070EN May 2017 iii

Dielectric grease application to recloser cable instructions Product information Introduction Service Information MN280070EN provides factory recommended inspection and cleaning of recloser/control cables and the application instructions for dielectric grease. Refer to the appropriate Service Information for complete installation and maintenance instructions for your specific product. Service Information MN280060EN, Installation of Types VWE, VWVE27, VWVE38X, WE, WVE27 and WVVE38X Service Information S280-40-7, Types RXE and WE Maintenance Instructions Service Information MN280061EN, Maintenance of Types VWE and VWVE Reclosers Service Information S280-40-4, Maintenance of Early WE Reclosers Service Information MN280063EN, Installation of Types VSA12, VSA16, VSA20 and VSA20A Reclosers Service Information MN280064EN, Maintenance of Types VSA12, VSA16, and VSA20/800 Reclosers Service Information S280-45-3, VSML Recloser Maintenance Manual Service Information S280-45-2, Maintenance of Early VSA Reclosers Service Information S280-42-1, NOVA 15, 27 and 38 kv Reclosers Installation and Operation Instructions Service Information MN280046EN, Types NOVA STS-15, NOVA STS-27, and NOVA STS-38 Single-Tank, Triple- Single, Electronically Controlled Recloser Installation and Operation Instructions Service Information MN280045EN, NOVA-TS 15, 27, and 38 Recloser Installation and Operation Instructions Service Information MN280048EN, SPEAR Single- Phase Recloser System Installation and Operation Instructions Service Information MN280049EN, Form 4D Control Installation and Operation Instructions Service Information MN280065EN, Type VSO12 and VSO16 Motor-Operated, Electronically Controlled Recloser Operation and Installation Instructions Service Information MN280066EN, Maintenance of Type VSO Reclosers Service Information S280-70-2, Form 6 Yard Mount Recloser Control Instructions Service Information S280-70-3, Form 6 Pole Mount Recloser Control Instructions Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional information These instructions cannot cover all details or vari ations in the equipment, procedures, or process described, nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not cov ered sufficiently for the user's purpose, please contact your Eaton representative. Acceptance and initial inspection Cables are thoroughly inspected at the factory. They are in good condition when accepted by the carrier for shipment. Upon receipt of the cables, a thorough inspection should be made for damage, evidence of rough handling, or shortages. Should this initial inspection reveal evidence of rough handling, damage, or shortages, it should be noted on the bill of lading and a freight claim should immediately be made with the carrier. Also, notify your Eaton representative. Handling and storage Be careful during handling and storage of the cable to minimize the possibility of damage. If the cable is to be stored for any length of time prior to installation, provide a clean, dry storage area. Quality standards ISO 9001 Certified Quality Management System. NNote: Any cable (any manufacturer) is subject to the environment; Eaton's Cooper Power series cables are no different. If the cable is not installed properly, a potential for moisture ingress exists and therefore, a potential for corrosion exists. It is recommended practice to train and support cables (e.g., with cable ties, etc.) in such a manner as to relieve the connector of excessive dead weight strain and minimize the effect of wind force on the cable. Materials and tools required Small wire brush Pipe cleaners Disposable cleaning towels Electrical insulating compound - AGS High Energy Dielectric Protector, Dow Corning 4 electrical insulating compound, or approved equivalent. 1 CABLE INSTRUCTIONS MN280070EN May 2017

Dielectric grease application to recloser cable instructions Figure 1. Use only approved electrical insulating compounds (AGS high energy dielectric protector shown) CAUTION Use only approved electrical insulating compound. Equipment damage may occur if an incompatible electrical insulating compound is used. T381.0 Inspection and cleaning procedure Figure 2. Disconnect the cable(s) at the recloser and junction box 3. Inspect recloser receptacle and control cable connector for signs of corrosion. 4. If corrosion is present, use a small brush to clean the accessible surfaces and pipe cleaners to clean hard to reach places to remove as much of the corrosion as possible. 1. Ensure the equipment (recloser, control and junction box (if present)) is de-energized. Hazardous voltage. De-energize switchgear before attempting to disconnect control cable from control. Failure to do so may result in contact with high voltage pulse (300 V peak) from the CT protection circuit. Failure to de-energize switchgear can result in contact with high voltage, which will cause death or severe personal injury. G124.0 2. If connected, remove the cable(s) from the recloser, control and junction box. See Figure 2. Figure 3. Corrosion residue left on 26-pin J-Box receptacle 5. If extensive corrosion is seen or in the event of visible damage to pins, replace the affected parts. Contact your Eaton representative for further assistance. NNote: If connection was previously greased, and both connectors have evidence of dielectric grease on them, there is no need to apply a second coat of dielectric grease. If either connector is new or has no evidence of dielectric grease, apply to the female connector per the instructions steps 6 through 13. CABLE INSTRUCTIONS MN280070EN May 2017 2

Dielectric grease application to recloser cable instructions Dielectric grease application procedure 6. If no corrosion is present or after a majority of the corrosion has been removed, clean and dry the female recloser receptacle and female cable connector. Next, apply 1/16th of an inch of AGS High Energy Dielectric Protector, Dow Corning 4 electrical insulating compound, or approved equivalent (approximately the thickness of a quarter) uniformly across the clean and dried face of the female connector. There is no need to apply dielectric grease to the male recloser receptacle and male cable connector. Dielectric grease will displace any moisture from bridging the gap between the pins and prevent corrosion. Figure 4. Female receptacle with dielectric grease applied NNote: A properly installed cable is fully seated when connected such that the O-ring is compressed. 7. Insert the cable connector into the receptacle on the recloser. Ensure the keyway lines up properly. 8. Ensure the cable connector is fully mated with the receptacle. 9. Rotate the cinch ring on the cable connector until the cable connector is fully seated this means that the cinch ring is turned a full 7 revolutions (approx. 20 turns of the wrist). 10. The cinch ring should be hand tightened. When it can be turned no further by hand, give the plug body a push into the mating receptacle and continue turning the cinch ring. Continue this process until the cinch ring will turn no further by hand and the plug body cannot be pushed any further into the mating receptacle. CAUTION If the cinch ring cannot be turned any further but the plug body can be pushed in and out of the receptacle, the connector is likely cross-threaded. In this condition, the connection seal is compromised. This condition must be corrected or equipment damage may result. T380.0 11. Repeat the same procedure for the control and junction box (if present). 12. Verify the recloser and control operation by opening and closing the recloser several times via the front panel buttons on the control. Verify the open and close status lights on the control correspond to the state of the recloser. 13. The recloser is ready to put into service. Figure 5. Visual aid for application of dielectric grease. 3 CABLE INSTRUCTIONS MN280070EN May 2017

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN280070EN May 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.