ABB AG, Transformers Active arcing fault protection system for dry-type transformers. ABB Group April 17, 2013 Slide 1

Similar documents
Ultra Fast Earthing Switch UFES retrofit Overview

Arc Flash Detection and Mitigation

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

PowerCube type PB series A complete solution for OEMs

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

ZX-Family Gas-insulated medium voltage switchgear

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Modular medium-voltage switchgear. NorMax

UniGear. Technical Guide

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Unified requirements for systems with voltages above 1 kv up to 15 kv

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

TGK Prefabricated Substation Technical Data

HD4. Gas insulated MV circuit-breakers kv A ka

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

Extensible Unit - VCE2a

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

HMI, APRIL, Test Laboratories in Ratingen

Power IT Air Insulated Cubicle Uniswitch

(Under Two Part Bid System) Tender No: NFV/ PUR/ BEC K for VCB

Unitole UP kv Primary substations Motor control centres

Xiria the smart solution

One-Fit,UFES, Reyrolle LM

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1


DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

33KV INDOOR SWITCHGEAR

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

ABB n.v PQF LV Active Filters: Bringing energy savings to you

Low Voltage Main Distribution Board

ZX2.2 Gas-insulated medium voltage switchgear

Xiria the smart solution

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

CHAPTER 4 PROTECTION REQUIREMENTS

Metal enclosed capacitor banks: ABBACUS family

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Review paper on Fault analysis and its Limiting Techniques.

Outdoor load disconnectors Fla 15/97 GB. three-pole design rated voltage 25 kv rated current 630 A

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

NXPLUS C Single busbar. Maintenance-free for lifetime

ZX2 Gas-insulated medium voltage switchgear

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

Chapter 6 Generator-Voltage System

Logstrup Modular System

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

I B D Q I B D Q O I B D Q O

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Unitole UP kv Primary substations Motor control centres

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

CPG.0 Single busbar gas-insulated cubicles

MOULDED CASE CIRCUIT BREAKERS BC160N

PIX-H Metal-clad switchgear up to 17.5kV

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

the safe, reliable, and efficient choice for MV switchgear

3AP1 DTC for 145 and 245 kv

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Air-insulated switchgear UniGear type ZS1

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Limitor -G General Purpose Fuses

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Transformer Protection

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Current accuracy class. Sensor principles

cor Long Run Experience

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

ABB Switzerland Ltd High Voltage Products PTHG-V / Marta Lacorte Business Development LAM High Current Systems. Generator Circuit- Breaker Systems

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Transcription:

ABB AG, Transformers Active arcing fault protection system for dry-type transformers April 17, 2013 Slide 1

Active arcing fault protection system prevents arc faults When an arcing fault occurs in an electrical installation, it usually goes hand in hand with very high thermal and mechanical loads for the affected area Arcing faults can be caused by incorrect dimensioning and reductions in insulation due to contamination etc., but they can also be the result of handling errors An arcing fault can have fatal consequences for the operator and strongly damage the system and even the building Reliable protection of people and property with the Ultra- Fast Earthing Switch (UFES TM ) is now also available for dry-type transformers April 17, 2013 Slide 2

Ultra-Fast Earthing Switch type UFES The new active internal arc protection by ABB Active internal arc protection in addition to available passive protection with UFES Highest possible protection for electrical components in regard to the hazardous impacts caused by an internal arc April 17, 2013 Slide 3

Comprehensive tests document the high protection Tests with UFES Arc ignited on HVside Before After Arc ignited on LVside Before After April 17, 2013 Slide 4

Comprehensive tests document the high protection Tests with arc fault protection enclosure, without UFES Arc ignited on HVside Before After April 17, 2013 Slide 5

Delivery options New transformer with integrated UFES ABB Service Box (up to 24 kv) The universal ABB UFES Service Box for subsequent upgrading of ABB transformers with a protective enclosure. ABB Service Withdrawable Unit Solutions UFES primary switching elements installed in ABB withdrawable units/truck-type switchgears offer a simple means of upgrading existing switchboards with active arcing fault protection, e.g. for transformers April 17, 2013 Slide 6

Technical data *on request Rated voltage up to 17,5 kv up to 27 kv up to 36 kv up to 40,5 kv * Rated Short-time Withstand Current (3s) 25 ka 40 ka 50 ka 25 ka 40 ka 25 ka 40 ka 25 ka 40 ka April 17, 2013 Slide 7

Advantages of a protected transformer with UFES Greatly enhanced protection of people Far higher availability of systems and processes for the greatest possible competitiveness Drastically reduced repair costs through minimum impact of faults on the system: transformer and enclosure can be reused in the event of a fault; only the UFES unit needs to be replaced Use of energy-efficient cooling solutions in combination with enclosures independent of the IP-class Certified by IAC BFLR test (PEHLA) April 17, 2013 Slide 8

Further accessories I s -limiter April 17, 2013 Slide 9

I s -limiter I s -limiter as component or integrated in an air-insulated switchgear Rapid short-circuit current limitation in the first rise Reduction of the continuous current heat losses in distribution networks In use in power plants, by utilities or in industrial networks Chance: Direct positive economic and positive environmental impact for the customer No risk for the customer April 17, 2013 Slide 10

I s -limiter Technical data of I s -limiter Technical data of I s -limiter Rated voltage Rated current Switching capability 0,75 kv 12,00 kv 17,50 kv 24,00 kv 36,00 kv 40,50 kv 5000 A 4000 A 4000 A 3000 A 2500 A 2500 A 140 ka RMS 210 ka RMS 210 ka RMS 140 ka RMS 140 ka RMS 140 ka RMS For higher rated currents I s -limiter can be connected in parallel April 17, 2013 Slide 11

I s -limiter Customer advantages Product / System / Service I s -limiter in the coupling of distribution arrangements to balance the transformer load Customer advantage Reduction of the continuous heat losses in the transformers due to optimized current distribution Improvement of the Power Quality Better energy reliability Reduction of network impedance No need for new switchgear with higher short-circuit ratings April 17, 2013 Slide 12

I s -limiter Separate energy distribution (without I s -limiter) Separate energy distribution (without I s -limiter) 110 kv T1 S r P CU,r = 50 MVA = 300 kw T2 S r P CU,r = 50 MVA = 300 kw I T1 = 0,5 x I r I T2 = 0,5 x I r 10 kv 10 kv Copper losses (current heat losses) in the transformer, P CU ~ I 2! T1: I T1 = 0,9 x I r => P CU,T1 = 0,81 x P CU,r = 0,81 x 300 kw = 243 kw T2: I T1 = 0,1 x I r => P CU,T2 = 0,01 x P CU,r = 0,01 x 300 kw = 3 kw Total sum of copper losses (current heat losses) = 246 kw April 17, 2013 Slide 13

I s -limiter I s -limiter in the coupling I s -limiter in the coupling 110 kv T1 S r P CU,r = 50 MVA T2 = 300 kw S r P CU,r I T1 = 0,5 x I r I T2 = 0,5 x I r 10 kv 10 kv = 50 MVA = 300 kw Potential of savings in 30 years: 96 kw x 24 h x 365 days x 30 years = 25,228,800 kwh This is equal to ca. 7,500 tons black coal Resp. ca. 26,000 tons CO 2 T1: I T1 = 0,5 x Ir => P CU,T1 = 0,25 x P CU,r = 0,25 x 300 kw = 75 kw T2: I T1 = 0,5 x Ir => P CU,T2 = 0,25 x P CU,r = 0,25 x 300 kw = 75 kw Reduction of copper losses (current heat losses) from 246 kw to 150 kw (separate energy distribution creates 64 % higher losses)! April 17, 2013 Slide 14