Stack Light- Light Only. Stack Light with Sound

Similar documents
Product Application Guide- 30mm Stacklights. 30 mm Stacklight- Light Only

Construction of Magnetic Buzzer

ULTRAPROBE 201. Instruction Manual

General safety and installation information.

CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac Monarch RARE / VINTAGE / HARD TO GET

Specifications. General

Piezoelectronic Products Piezoelectronic Buzzers(without circuit) Pin Terminal/Lead

ANALOG SOUND LEVEL METER

Dealing with customer concerns related to electronic throttle bodies By: Bernie Thompson

DIY Synth Kit - Manual STUTTER SYNTH

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

Choose the future Choose

Type 4 Vertical Kink Short Lead. Double Outside Kink Lead (Gz Use) Type 6 Double Outside Kink Lead (Ks Use)

PRODUCT SPECIFICATION. Stack Lights. Series.

DIY Synth Kit - Manual

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:


ASI. Blinking or Steady Light Modules

In the first part of this series on

PKG-341-MBC08-PS-CBL System Diagram and Specifications

Iron Gate Air Pump System Manual

Switches Unlimited Contact: Phone: * Fax:

HAWK401-A Reverse Assistance System

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

WARNING. This product uses High Brightness LEDs. Direct viewing of the SMD LEDs at close range should be avoided. Keep product away from children.

Throttle Cable Pull - Patent Pending By: NetGain Controls, Inc.

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

E.S.P. Embedded Sensing Probes for Motor Brushes

Nero 6600H/6601H. Installation Guide. Commercial Vehicle Productivity and Security. Antenna Configuration

Build Instructions and User Guide

INSTALLATION MANUAL. Middle. Def tank. Standard. Middle. Standard. Def tank WARNING. Level of Difficulty CAUTION. Parts List.

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

Reference Only. *B: Bulk packing also available. Inductance. Tolerance M:±20% N:±30% 0.150±25% 1.0 * * N:±30% 0.23±25% 0.8 *2 0.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

I-BFV.KIT Butterfly Valve Gear Operator Replacement

PN CHEVY TRI-FIVE. Kit Contents: Four panel Sequential LED Taillight kit installation guide

Reference Only. Inductance Frequency (μh) Tolerance Typ Max (MHz min.) 85 *

Signal towers and beacons

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

Page 8-3. MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75. Modular signal towers Ø70mm/2.75

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

General_technical_data Series

DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

Acceleration sensors (ICP technology) VBS 50 overview Configurations

Variable Speed Pumping

White Light CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac RARE / VINTAGE / HARD TO GET

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

Reference Only. 1. Scope This reference specification applies to LQM2MPN_G0L series, Chip Coil (Chip Inductors).

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Uninterruptible Power System

VFD Best Practices: Getting the Most from Your VFD Investment

Noise Emissions At the Chicago Fuller Car Wash

Briefing on Automotive NVH Technique

SYSTEM OPERATION IMPORTANT CAUTIONS

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Understanding The HA2500's Horiz Driver Test

Tactile Switch (Hinged Type)

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Plus SABRE LIGHTBARS

SIGNAL BEACONS Signal beacons Ø62mm Blinking or steady light modules Sound-light pulsed or continuous modules Incandescent and LED bulbs.

Model APS-101N Installation Manual

INSTALLATION INSTRUCTIONS:

Mounting hardware and accessories

Wire Wound Chip Inductor

INSTRUCTION MANUAL A141 High Level Audible Warning System / Battery backup

UltraSystem Series II INSTALLATION MANUAL PARTNERED WITH

Spezifikation für Freigabe / specification for release

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

PI1500X Power Inverter User s Manual

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

CIRCLE SEAL CONTROLS

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

SAFETY WARNINGS AND GUIDELINES

NAVIGATOR with PHCU Installation Instructions

2015 Mustang Lightbar (All Models) CDC#

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Spezifikation für Freigabe / specification for release

CA 421 Installation Instructions

$3-5/speaker 60 min Magnet Wire - Sandpaper

THIS PAGE WAS INTENTIONALLY LEFT BLANK.

PeroxiDraw Dispenser

Disaster Transport CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac RARE / VINTAGE / HARD TO GET

Spray Clean 606T-2 Installation Instruction

Vandal Resistant Ringdown/Autodialer Telephone

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Norcal Power/SWR Meter Assembly & Operating Manual. Revision 1D 10/15/2008

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG CEG

INSTALLATION INSTRUCTIONS CATHEDRAL CHIMES. ATTENTION: Please leave this instruction booklet on the job site for future reference.

Wire Wound Chip Inductor-WB Series

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Transcription:

Stack Light- Light Only Part Number Structure JT 028 - RYGBC - C D Series: JT = Triangle Shaped Stack Light Maximum Voltage: 028 = 20 28 Vac/dc; 120 = 90 120 Vac Only Stack Colors: R = Red; Y = Yellow/Amber; G = Green; B = Blue; C = Clear/White Light Function: C = Continuous On Mounting Type: D = Direct; S = Stainless Pole Stack Light with Sound Part Number Structure JT 028 - RYGBC - C D L Series: JT = Triangle Shaped Stack Light Maximum Voltage: 028 = 20 28 Vac/dc; 120 = 90 120 Vac Only Stack Colors: R = Red; Y = Yellow/Amber; G = Green; B = Blue; C = Clear/White Light Function: C = Continuous On Mounting Type: D = Direct; S = Stainless Pole Sound Loudness (Typical @ 1 Meter): L = Loud (80 to 85 db); M = Medium (70 to 75 db)

Page 2 Stack Light Instructions Warnings: Turn power off before installation, repair, or maintenance to avoid shock (potentially fatal), burns, or damage to the stack light and the equipment in which it is installed. This unit is not designed to support any external weight. It is not to be used as a handhold or support for a person. Cautions: This unit is rated for indoor use only. It is not recommended to install this unit sideways or inverted. Make sure that the unit is rated for the voltage being applied. It is recommended to only use a slightly damp cloth to clean this unit. Other cleaning agents could affect the waterproof integrity or mar the surface finish potentially affecting its visual characteristics. Do not push or pull on wires. Pole Mounting: 1. The diagram on the left details the 4 holes needed for the pole-mount bracket. The center hole size of 0.57 (14.6 mm) is the minimum size and can be larger. 2. Use three standard #10 or 5mm screws (not included), or alternately, use self -taping screws. 3. Before drilling holes, use a nail punch to mark the center of the screw hole locations. 4. When inserting wires through the center hole, be careful not to pinch the wires under the bracket. 5. Be careful not to over-torque the screws which can cause the plastic bracket to crack. 6. The gasket on the bottom of the bracket is needed to ensure waterproof ratings. Do not remove. 7. If the installation surface is not flat, silicone adhesive may be needed to ensure waterproof ratings. Direct Mounting: 1. Per the diagram on the left, drill or punch a 0.88 (22.2 mm) hole into the installation surface. 2. Remove the nut from the stack light pipe. 3. Carefully insert the wires and stack light pipe through the hole being careful not to pinch the wires. 4. Put the nut over the wires and carefully thread the nut onto the stack light pipe. 5. Tighten the nut making sure not to over-torque the nut. 6. To ensure waterproof ratings, it is recommended to use Teflon tape on the pipe threads

Page 3 Wiring Diagram- Lights (LED s) & Sound 28 Volt 120 Volt White Wire (Clear/White LED) Blue Wire (Blue LED) Green Wire (Green LED) Yellow Wire (Yellow/Amber LED) Red Wire (Red LED) I<50 ma I<210 ma I<50 ma I<200 ma I<40 ma I<190 ma I<60 ma I<230 ma I<50 ma I<210 ma Green with Yellow Stripe Wire (Sound Common Wire for Other Tones) Notes: 1. Transistors or FET s can be used as switches as long as the device can handle the current draws listed. 2. Stack lights will only be supplied with the number of wires needed to operate that particular model of stack light. The above diagram is for 5 stacks and sound. If your stack light model has less than 5 stacks and/or does not come with sound, not all of the above wires will be present. 3. The stack light models are all non-polar. If connecting to a 24 Vdc power supply, it does not matter which way power supply s plus and negative terminals are connected in the above diagram. 4. The sound and LED lights operate independently of each other. 5. Do not connect the green with yellow stripe wire to power. This will likely cause the unit to fail and void the warranty. 6. In order for any sound tone to be generated, the gray and black wires must be connected to the power supply. When only the gray and black sound wires are connected, a continuous tone will be heard. To activate the other tones, the orange and purple wires must be connected to the green with yellow stripe wire in various configurations. See the Sound Control Diagrams on how to activate the four different sounds. LED Operation: The brown wire must be connected to one side of the power supply and the appropriate LED stack color wire connected to the other side of the power supply. One or more stacks can be activated at the same time.

Page 4 Sound Control Diagrams Continuous Sound Connect the black wire to one side of the power supply and connect the gray wire to the other side. Green/Yellow Wire (Sound Common Wire for Other Tones) Medium Pulse Sound Connect the black wire to one side of the power supply and connect the gray wire to the other side. Green/Yellow Wire (Sound Common Wire for Other Tones) At the same time, connect the green with yellow stripe wire to the orange wire. Double Pulse Sound Connect the black wire to one side of the power supply and connect the gray wire to the other side. Green/Yellow Wire (Sound Common Wire for Other Tones) At the same time, connect the green with yellow stripe wire to the purple wire. Continuous/Short Pulse Sound Connect the black wire to one side of the power supply and connect the gray wire to the other side. Green/Yellow Wire (Sound Common Wire for Other Tones) At the same time, connect the green with yellow stripe wire both to the orange wire and the purple wire.

Page 5 Piezoelectric Electronic Alarm Construction The above cross section picture shows the basic elements used in a piezoelectric audible alarm. The area in front of the transducer element including the front hole opening forms an acoustic cavity that lets the sound radiate out with the most efficiency (i.e. loudest sound level). If the alarm is an indicator that contains a circuit board, the circuit board is attached to the piezoelectric sounder element via soldered wires. The above picture can be interpreted to represent a board mount package with pc pin terminations, but the same concept is used when building audible alarms in other mounting configurations such as SMT, Flange Mount, and Panel Mount alarms. If the back of the alarm is sealed with epoxy or other material, the guts of the alarm (including the circuit board and components) are protected against fluid intrusion. However, fluid sitting inside the front cavity can obstruct the operation of the device causing the sound level to decrease significantly. If you need to wash the alarms after a soldering operation, it is strongly recommended to use an alarm that comes with a wash label that keeps the washing fluid from getting inside of the front cavity.

Page 6 Operation of Piezoelectric Audible Alarms Piezoelectric electronic audible alarms work by converting the user input voltage to an appropriate oscillating signal that is applied to a sounder element that is mounted in a housing. The piezoelectric sounder element consists of a metal disc that has a special ceramic material bonded to it that physically bends when voltage is applied to it. The above picture shows a bare piezoelectric sounder element. By applying a sinusoidal waveform at an appropriate frequency, the transducer will physically deflect in one direction and then in the opposite direction following the shape of the input wave-form. If this oscillation occurs in the audible frequency range (1 Hz to 20 khz), then air pressure waves are produced that the human ear interprets as an audible sound. The larger the voltage of the applied wave-form, the larger the amplitude of the air pressure waves resulting in a louder sound level. However, the ceramic portion of the transducer can only bend so far before there is a risk of a catastrophic failure. This maximum voltage is somewhere around 40 to 50 volts. However, it is rare to apply this much voltage to a transducer as you reach a point of diminishing returns for voltages much greater than 32 volts. By itself, the sound level produced by a transducer element is insignificant. To increase the size of the air pressure waves (and thus the sound level), the transducer element must be mounted inside an acoustic chamber that is optimized for the transducer size and resonant frequency. Every transducer has one frequency where it flexes more efficiently producing the louder sound levels. This frequency where the transducer performs the best is called the resonant frequency. Self-Drive type devices provide a 3 rd terminal that connects to an isolated portion of the piezoelectric transducer. This third terminal provides a feed-back signal that is 180 degrees out of phase with the drive signal. This signal can be fed back into the circuit to allow the sounder element to self-tune itself to the transducer s resonant frequency.

Page 7 Decibel Sound Level Scale The decibel sound level scale is an arbitrary scale that ranges from 0 db (threshold of hearing) to 130 db (threshold of pain). The chart below shows where some common sounds fall on this db scale. Audible alarms are available that have sound levels as soft as 55 db at 2 feet and as loud as 110 db at 2 feet.

Page 8 Fundamental Frequency & Harmonics Below is a frequency scan of a piezoelectric audible alarm that has a resonant frequency of 2,800 Hz. As you can see, there is a strong frequency peak at 2.8 khz and several smaller frequency peaks that follow called harmonic frequencies. The table below the chart shows that the size of the harmonic frequencies are significantly smaller than the fundamental frequency for this particular alarm unit. Because this alarm has a large fundamental frequency and much smaller harmonic frequencies, the sound quality of this part will be very good. When this alarm is activated, the listener will hear one clear frequency (also called sound pitch) from the alarm. Other electronic alarm technologies such as electro-magnetic or electro-mechanical type alarms often have much larger harmonic frequency components resulting in less clear tone.