Power pack type UHMZ 63

Similar documents
Power pack type UHJV 63

Power pack type UHPT

Power pack type UHJV 250

Power pack type UHMZ 25

Power pack type UHKZ

Pressure relief valve, pilot operated, sandwich plate type UZPR10

2/2 - way cartridge valve type URZS/S

3-way flow control valve type UDUE10 is intended for

Double throttle/check valve type Z2FS16

WK Proportional pressure reducing valve, cartridge design type WZRS6. NS 6 up to 5 MPa up to 40. dm /min APPLICATION DESCRIPTION OF OPERATION

DESCRIPTION OF OPERATION

Directional spool valve type WH16 hydraulically operated

2/2- way directional valve type URZS40 Cover of directional valve type ULZS40

Directional spool valve type WMM 16 hand lever operated

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

6-way section directional valves type 6URRE6

2-WAY FLOW CONTROL VALVE TYPE UDRD6

6-way section directional valves type 6URRE6 consist

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

Directional cartridge valve type. tight on both sides type 2URED6

Directional cartridge valve tight on both sides type 2URED6 3

Pilot operated pressure relief valve type DB 3

Directional control valves hydraulically operated type WHG6/WHP6

6/2 way directional valve type 6/2UREM6 and 6/2URMM6

Direct operated pressure relief valve type DBD

PRODUCT CATALOGUE oil hydraulic components and systems

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION

Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

Pilot Operated Pressure Relief Valve Series R5V (Denison)

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

Double throttle check valve Type Z2FS 10

Clamping and drive module

S.A. 193 Stefan Cel Mare str., 2400 Sibiu -Romania

Pressure reducing valve, pilot operated Type DR

«Standard» Hydraulic power unit BM

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

Double throttle/check valve type Z2FS10

Check-Q-meter type FD

Hydraulic Motor (Radial piston multi-stroke)

THE PRODUCTION LINE OF PONAR WADOWICE

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Pressure Control Valves. General Description. Specifications. Ordering Information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

M7X / M7V Series. Swash Plate Type Axial Piston Motor. Precision Machinery Company

RC /

Size 6 10 up to 31.5 MPa up to 120L/min

AXIAL PISTON MOTORS SHMF

Solenoid Pilot Operated Proportional Directional Control Valve

Hydraulic primary unit Type ABPAG

Proportional pressure reducing valve, pilot operated

Double throttle/check valve type Z2FS6

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Proportional pressure relief valve Types DBE(M) and DBE(M)E


C9: BMM, BMP, BMR, BMH, BMJ Series & Valves CONTENT. Usage Guide 2. BMM Series Hydraulic Motors 3. BMP Series Hydraulic Motors 11

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Pressure relief valves,type DB3U Huade América 1

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Eaton Char-Lynn Low Speed High Torque Orbit Motor for Swing Drive

Pressure sequence valve pilot operated

Greasing machines MPD 60-1, MPD 60-2

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

Proportional pressure reducing valve

Pilot-Operated Pressure Relief Valve Series RM

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

ELD Series - DC Motor Drive

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

NDJ Series New DAIPACK

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

B Manifold K or O Assembly Parts List. Parts

Technical Data 2506A-E15TAG3 2506A-E15TAG Series. Diesel Engine - ElectropaK

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Pilot operated check valves, Types SV and SL...40B/ (new series) Huade América 1

Proportional flow control valve 2-way versiontype 2FRE 6...RC

ELH Series - Hydraulic Fan Drive

Internet For latest information, PDF catalogs and operation manuals

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Flow sharing control block in mono block / sandwich plate design M6-15

Technical Data 2506C-E15TAG3 2506C-E15TAG Series. Diesel Engine - ElectropaK

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Fixed Displacement Plug-In Motor A2FE

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Axial piston variable pump A4VG Series 40

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Chapter 5: Flow Valves

Flow sharing control block in mono block / sandwich plate design M6-22

Solenoid Pilot Operated Directional Control Valve

Transcription:

Power pack type UHMZ 63 p max = 20 MPa Q = 10 3 cm /rev max WK 560 505 04.2008 PPLICTION Power pack is intended to supply hydraulic system with hydraulic fluid (oil) according to the required parameters (pressure and displacement). DESCRIPTION Power pack in standard consists of the oil tank and the key accessories such as: filler breather filter; oil level indicator (optical) with possibility of electric indication on minimum level; thermometer; revision seals; oil drain plug; magnetic filter (or plug) and of pumping unit (electric motor - gear pump), oil filter (low pressure filter), and also measuring block with pressure gauge switch, pressure gauge and output connections. Standard version of the power pack can be extended (upon customer request) with: hydraulic control system according to individual scheme; temperature regulation system (air cooler or water cooler, heater, heat sensor, temperature regulator); other equipment and hydraulic machines, which are not included in the data card, after prior consultation with the manufacturer electric control system The extension of hydraulic system can be made: on the blocks for column mounting (WK560 520) standard version, on multi-station manifold blocks type ULR 6 6 (WK 450 499), in board.system (using individual subplates type G ). TECHNICL DT (table1) Nominal oil tank capacity 63 dm 3 Oil capacity difference corresponding to oil level difference up to 13,9 dm 3 max - min Hydraulic fluid mineral oil Operating temperature range - 10 up to + 70 C Standard filtration 16µm Viscosity 10 380 mm 2 /s Motor supply voltage 230/400V 50Hz (other, if agreed) Type of pump 10C4,2X053G 10C6,1X053G 20C10X016G Operating pressure up to 20 MPa up to 20 MPa up to 20 MPa Displacement 4,2 cm 3 /revolution 6,1 cm 3 /revolution 10 cm 3 /revolution Type UHMZ 63-1 -

HYDRULIC SCHEME Connect nections (table 2) Port P T Connections for NS6 G1/2" G1/2" G1/2" G1/2" outputs of receivers R1 R2 R3 R4 R5 R6 hydraulic equipment P P T T water cooler P T Y water air cooler M for filter M Operat ating pressure range r depend nding ng on the motor m or power p and type of f pump (table 3) Motor type Power [kw] 10C4,2X053G 10C6,1X053G 20C10X016G pressure [MPa] pressure [MPa] pressure [MPa] SKg 80-4 0,75 6,3 - - SKg 90 S4 1,1 10 6,3 - SKg 90 L4 1,5 13 8,4 5 SKg 100 L4 2,2 20 12,3 7,6 SKg 100 L4 3-16,7 10 SKg 112 M4 4-20 13,8 SKg 132 S4 5,5 - - 19-2 - Type UHMZ 63

OVERLL ND CONNECTION DIMENSIONS 250 Max 1230 - for 6 sections NS6 Level sensor 40 312 215 52 max 1110 Water cooler 660 135 O14 308 508 Oil heater 45 285 376 Outputs, max 460 Electric box 150 Over verall l dime d imensions s depending ng on the motor m or power p and type of f pump (table 4) Motor type Dimension 10C4,2XO53G 10C6,1X053G 20C10X016G SKg 80-4 0,75 [kw] 955 - - SKg 90S4 1,1 [kw] 988 988 - SKg 90L4 1,5 [kw] 1015 1015 1015 SKg 100 L4 2,2 [kw] 1055 1055 1055 SKg 100 L4 3 [kw] - 1055 1055 SKg 112 M4 4 [kw] - 1065 1065 SKg 112 M4-PC 5,5 [kw] - - 1150 Type UHMZ 63-3 -

DDITIONL When selecting power pack to the machine it is necessary to consider its total heat balance by specifying oil temperature in the tank it should not exceed 55 C (328 K). If necessary, oil cooler must be used for the hydraulic system. Thermal power output of the power pack tank to the environment can be estimated using below formula or diagram. N output = k x x T N output [ W ] - thermal power output of the tank [m 2 ] - active surface area of the tank for the power pack tank UHMZ 63 = 1,02 m 2 k [W/m 2 x K] - heat exchange factor k = 5 W/m 2 x K - when poor air circulation, unfavourable location, k = 10 W/m 2 x K - normal air circulation from all directions, k = 20 W/m 2 x K - when intensive air circulation (unnaturally forced), T [ K ] - temperature difference between the tank (oil) and the environment T [K] 50 40 30 20-3 2 k = 5 x 10 [kw/m K] -3 2 k = 10 x 10 [kw/m K] -3-3 -3-3 2 k = 20 x 10 [kw/m K] 10 0 0,5 1 1,5 N output [ kw ] Thermal power output of the power pack tank UHMZ 63-4 - Type UHMZ 63

HOW TO ORDER ny order should be addressed to the manufacturer according to the below coding. UHMZ 63 Tank capacity 63 dm 3 = 63 * Type of pump 10C4,2X053G = 4,2 10C6,1X053G = 6,1 20C10X016G = 10 Motor power (according to the table 3) 0,75 kw = 0,75 1,1 kw = 1,1 1,5 kw = 1,5 2,2 kw = 2,2 3,0 kw = 3 4,0 kw = 4 5,5 kw = 5,5 Nominal size of hydraulic elements mounted (referred to connections of directional valves) NS6 = 6 Designed version standard version (without connection for directional valve) with the connection for one directional valve with the connection for two directional valves with the connection for three directional valves with the connection for four directional valves with the connection for five directional valves with the connection for six directional valves Oil level indicator without oil level indicator with oil level indicator of minimum level (electric) = no designation = R1 = R2 = R3 = R4 = R5 = R6 = no designation = N1 Cooler without cooler = no designation air cooler (according to the table 5) = P1 water cooler (according to the table 6) = W1 Successive number of power pack version (given by the manufacturer of the power pack when order confirmed) = XXXX Further requirements in clear text (to be agreed with the manufacturer) Coding example: UHMZ 63-10-3-6 -R3-XXXX NOTE: Type, quantity and placing hydraulic equipment (directional valves, valves and other), must be specified in the hydraulic scheme or in another clear way. Type UHMZ 63-5 -

SIC TECHNICL PRMETERS OF THE CCESSORIES ir cooler (table 5) Type Designation Motor power MG IR 2015K P1 0,045 kw MG IR 2024K P2 0,12 kw Voltage 230/400V 50Hz 230/400V 50Hz Rate of revolution r ~ 2850 revolutions/min ~ 2670 revolutions/min Power output for t = 20 C up to 2,5 kw up to 4,5 kw Water cooler (table 6) Type Designation Connection thread for water Thermostat type Power output for t = 35 C MGE 60-140-1 W1 G1/2 VT 15 1,5 3,5 kw Oil level indicator with electric indicator (table 7) Type Supply voltage Current Contact load capacity Contact state SNK 127V/O/O/12R 50V C/DC 0,2 2,5 W Open at minimum elow hydraulic equipment manufactured by PONR-WDOWICE S.. that can be used for control systems (table 8) Directional spool valve, electrically operated WE 6 according to WK 499 502 Directional spool valve, hydraulically operated WH 6 according to WK 420 170 Directional spool valve, hand lever operated WMM 6 according to WK 420 170 Directional spool valve, rotary knob operated WMD 6 according to WK 420 170 Pressure reducing valves, sandwich plate UZRC 6 according to WK 493 061 Pressure sequence valves, sandwich plate UZKC 6 according to WK 393 060 Check valves, sandwich plate WZZC 6 according to WK 450 355 Double check valves, pilot operated Z2S 6 according to WK 450 360 Double check valves, sandwich plate Z2FS 6 according to WK 450 232 Pressure switches (with subplate UŁC 6) USPH 4 according to WK 450 398 Pressure relief valves UZPR 6 according to WK 494 060 PONR Silesia S.. ul. Wojska Polskiego 29 34-100 Wadowice tel. +48 33 823 44 41-45 fax.+48 33 823 39 36 www.ponar-silesia.pl - 6 - Type UHMZ 63